Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Cataract Refract Surg ; 31(6): 1213-8, 2005 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16039500

RESUMO

PURPOSE: To evaluate the protective properties of combined sodium hyaluronate 2% and mannitol 0.5% (Visiol) on the corneal endothelium in the presence of oxidative stress induced by hydrogen peroxide (H(2)O(2)). SETTING: Instituto Oftalmológico de Alicante, Universidad Miguel Hernández, Alicante, Spain. METHODS: This was an exploratory randomized controlled parallel-group, masked-assessor study of 3 sodium hyaluronate-based ophthalmic viscosurgical devices (OVDs): Visiol, Healon (sodium hyaluronate 1%), and Viscoat (sodium hyaluronate 3%-chondroitin sodium 4%). The OVDs were tested for protective effects on the endothelium following oxidative stress induced by H(2)O(2) at increased concentrations: control (lactated Ringer's solution), 1 mM, 10 mM, and 100 mM. Groups without OVD were used as controls at the same concentrations of peroxide. Each animal received the same treatment in both eyes (10 eyes per group). Endothelial cell lesion was assessed using the Janus green photometry absorbance technique. RESULTS: At 10 mM peroxide concentration, the value of endothelial cell lesion was significantly lower in the Visiol (16.8%, P=.0056), Healon (22.2%, P=.0302), and Viscoat (21.6%, P=.0336) groups than in the control group (29.4%, no OVD). There was a trend in favor of Visiol to more efficiently reduce cell lesions of the endothelium, than Healon (P=.055) and Viscoat (P=.1013). Values of endothelial cell lesion at peroxide concentrations of 1 mM and 100 mM showed the same trends than those observed at 10 mM. CONCLUSIONS: All of the OVDs tested efficiently reduced endothelial lesions against free radicals compared with the control group in which no OVD was used. The following sequence for the efficacy of endothelial cell protection was established: Visiol>Viscoat>Healon>no OVD.


Assuntos
Endotélio Corneano/efeitos dos fármacos , Ácido Hialurônico/farmacologia , Manitol/farmacologia , Animais , Citoproteção/efeitos dos fármacos , Quimioterapia Combinada , Endotélio Corneano/metabolismo , Feminino , Radicais Livres/toxicidade , Peróxido de Hidrogênio/toxicidade , Estresse Oxidativo/efeitos dos fármacos , Coelhos
2.
J Cataract Refract Surg ; 30(11): 2303-10, 2004 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-15519079

RESUMO

PURPOSE: To investigate the correction of post-penetrating keratoplasty (PKP) astigmatism using laser in situ keratomileusis (LASIK). Visual and refractive outcomes were evaluated after LASIK was performed in 1 step (lamellar cut and ablation in 1 procedure) or 2 steps (lamellar cut then ablation in 2 successive procedures). SETTING: Department of Cornea and Refractive Surgery, Vissum-Instituto Oftalmológico de Alicante, University of Miguel Hernández, Alicante, Spain. METHODS: In this prospective observational study, 22 consecutive eyes were divided into 2 groups depending on the LASIK procedure performed to correct post-PKP astigmatism. Group 1 (1-step LASIK) included 11 eyes and Group 2 (2-step LASIK), 11 eyes. The patients were followed for 6 months. RESULTS: A statistically significant improvement was obtained in Group 2 with a mean vector analysis result of the cylinder of -4.37 diopters (D) +/- 1.79 (SD) (P = .018). In Group 1, the mean astigmatism correction was 2.38 +/- 1.71 D. The number of reoperations and residual refractive defects were significantly better in Group 2. CONCLUSION: The 2-step technique improved the accuracy of excimer laser correction of post-PKP astigmatism.


Assuntos
Astigmatismo/cirurgia , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Ceratoplastia Penetrante/efeitos adversos , Complicações Pós-Operatórias , Adolescente , Adulto , Idoso , Astigmatismo/etiologia , Topografia da Córnea , Feminino , Sobrevivência de Enxerto , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Refração Ocular/fisiologia , Segurança , Resultado do Tratamento , Acuidade Visual/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...