Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Emerg Med J ; 19(5): 480-1, 2002 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-12205021

RESUMO

Bowel infarction commonly presents as an acute abdomen that rapidly progresses to severe shock. The diagnosis is often not clinically suspected. Three cases are described where the diagnosis was made during dynamic contrast enhanced computed tomography (CT), when gas was demonstrated in the portal venous system and liver. Two patients died during surgery, the third survived because of the prompt diagnosis made on CT, and subsequent surgical treatment. The radiological findings are reviewed.


Assuntos
Infarto/diagnóstico por imagem , Intestino Delgado/irrigação sanguínea , Intensificação de Imagem Radiográfica , Tomografia Computadorizada por Raios X/métodos , Abdome Agudo/etiologia , Idoso , Evolução Fatal , Feminino , Humanos , Infarto/complicações , Masculino , Artéria Mesentérica Superior , Pessoa de Meia-Idade , Veia Porta
2.
Eur J Emerg Med ; 8(2): 151-2, 2001 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-11436913

RESUMO

Visualization of pre-cervical soft tissue swelling on a lateral radiograph is an important indicator of possible bony injury in the context of cervical spine trauma. We report a case where apparent swelling was in fact an artefact due to an inappropriately placed endotracheal tube. We recommend review of the position of endotracheal tubes when interpreting pre-cervical soft tissue swelling.


Assuntos
Artefatos , Vértebras Cervicais/diagnóstico por imagem , Vértebras Cervicais/lesões , Traumatismo Múltiplo/diagnóstico por imagem , Fraturas da Coluna Vertebral/diagnóstico por imagem , Erros de Diagnóstico , Edema/diagnóstico por imagem , Humanos , Intubação Intratraqueal/efeitos adversos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Lesões dos Tecidos Moles/diagnóstico por imagem , Tomografia Computadorizada por Raios X
3.
AJR Am J Roentgenol ; 175(6): 1627-30, 2000 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-11090391

RESUMO

OBJECTIVE: The purpose of this study was to evaluate the efficacy and complications of percutaneous 18-gauge core biopsies of lesions of the bowel wall using CT and sonographic guidance. A retrospective study was made of 15 biopsy procedures performed on 12 patients with suspected neoplasia of the gastrointestinal tract. The biopsies were performed when there were no sites of metastatic disease more readily accessible to biopsy and the lesion was inaccessible to endoscopic techniques or when the endoscopic biopsy findings were negative. CONCLUSION: Three biopsy procedures provided inadequate samples and the biopsies were repeated, giving a total of 15 biopsy procedures. A tissue diagnosis was made in all 12 patients. All procedures were well tolerated, and no immediate or delayed complications occurred. Percutaneous core biopsy of bowel wall masses is a safe technique that allows a histologic diagnosis to be obtained in difficult cases when other methods cannot provide an adequate tissue sample.


Assuntos
Biópsia por Agulha/métodos , Intestinos/patologia , Idoso , Feminino , Neoplasias Gastrointestinais/patologia , Humanos , Masculino , Radiografia Intervencionista , Estudos Retrospectivos , Segurança , Manejo de Espécimes , Tomografia Computadorizada por Raios X , Ultrassonografia de Intervenção
5.
J Clin Ultrasound ; 28(4): 187-9, 2000 May.
Artigo em Inglês | MEDLINE | ID: mdl-10751740

RESUMO

We present a case in which a strangulated incisional hernia following a renal transplant was sonographically diagnosed. The patient presented with acute pain and swelling over the transplant site 6 weeks after surgery. Sonograms showed a normal-sized kidney with normal echotexture, no evidence of hydronephrosis, and no perinephric collections. Color Doppler sonography and spectral analysis demonstrated normal blood flow throughout the kidney. Sonograms showed that the palpable mass was a dilated loop of fluid-filled small bowel. Sonography allowed the correct diagnosis to be established, and early surgical intervention allowed revascularization of viable bowel.


Assuntos
Hérnia Ventral/diagnóstico , Hérnia Ventral/etiologia , Intestino Delgado/cirurgia , Transplante de Rim/efeitos adversos , Dor Pós-Operatória/etiologia , Idoso , Cateterismo/efeitos adversos , Feminino , Hérnia Ventral/diagnóstico por imagem , Hérnia Ventral/cirurgia , Humanos , Intestino Delgado/diagnóstico por imagem , Intestino Delgado/patologia , Diálise Peritoneal Ambulatorial Contínua/efeitos adversos , Resultado do Tratamento , Ultrassonografia Doppler em Cores
6.
J Arthroplasty ; 14(7): 800-2, 1999 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-10537253

RESUMO

We studied the position of the popliteal artery in 32 patients with primary osteoarthritis of the knee. A total of 45 knees were studied using a noninvasive technique with color-flow duplex scanning. The distance between the popliteal artery and the posterior tibial cortex was measured in various positions of flexion. The distance separating them was found to be maximal between 60 degrees and 90 degrees. The study was repeated in a smaller series of 17 patients (20 knees) after knee replacement but with less conclusive results. We believe the safest position on which to operate in primary arthroplasty is with the knee in flexion, but the safety margins are not the same in revision surgery.


Assuntos
Articulação do Joelho/patologia , Osteoartrite do Joelho/cirurgia , Artéria Poplítea/patologia , Artroplastia do Joelho/métodos , Humanos , Artéria Poplítea/diagnóstico por imagem , Tíbia/patologia , Ultrassonografia
8.
Clin Radiol ; 53(9): 702-4, 1998 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-9766726

RESUMO

Three patients who were investigated with dynamic contrast medium enhanced computed tomography (CT) of the thorax were noted to have pericardial effusions with reflux of contrast medium back along the azygos vein. The diagnosis of cardiac tamponade was not made clinically, but in each case was suggested from the CT findings. Confirmation of the diagnosis was made in all three cases, two patients with echocardiography and one at post mortem. One patient made a rapid recovery following the insertion of a pericardial drain, another made a temporary recovery after pericardiocentesis but the third died. Thirty CT scans performed with similar protocol were reviewed and none of these demonstrated reflux along the azygos vein. The presence of contrast medium refluxing into the azygos vein implies significant haemodynamic disturbance, and in the presence of a pericardial effusion suggests the diagnosis of cardiac tamponade.


Assuntos
Veia Ázigos/diagnóstico por imagem , Tamponamento Cardíaco/diagnóstico por imagem , Meios de Contraste , Tomografia Computadorizada por Raios X , Adulto , Idoso , Tamponamento Cardíaco/complicações , Evolução Fatal , Humanos , Masculino , Derrame Pericárdico/diagnóstico por imagem
9.
Clin Radiol ; 53(5): 350-2, 1998 May.
Artigo em Inglês | MEDLINE | ID: mdl-9630273

RESUMO

The first long-term follow-up of the use of the Antheor inferior vena cava (IVC) filter is presented. Between December 1994 and December 1996, 20 Antheor IVC filters were inserted. Seven patients subsequently died and of the 13 patients remaining alive, 11 were available for long-term follow-up. One death was due to migration of the filter to the main pulmonary artery 6 weeks after insertion and because of this case, and other similar reports, the filter has now been withdrawn from clinical use. Of the 11 filters assessed at follow-up, three were fractured. One filter contained thrombus and one IVC was occluded. Our experience highlights the problem of central migration, but also shows a high incidence of filter fracture which has not previously been described with this design of filter.


Assuntos
Tromboflebite/cirurgia , Filtros de Veia Cava , Veia Cava Inferior , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Migração de Corpo Estranho/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Falha de Prótese , Artéria Pulmonar , Taxa de Sobrevida
10.
Clin Radiol ; 53(4): 296-301, 1998 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-9585048

RESUMO

Calcific tendinitis of the gluteus maximus tendon is unusual and only eight cases associated with erosions of cortical bone have been reported. We present three further cases which demonstrate variation in appearances of the amorphous calcification in the tendon and cortical erosions on plain radiographs. Isotope bone scans show focal increased activity and computed tomography (CT) clearly demonstrates erosion of cortical bone and calcification within the tendon insertion of gluteus maximus. Follow-up examinations in two cases demonstrated resolution of the changes. We believe this series demonstrates the radiological features and natural history of a common condition occurring at an unusual site. Its recognition is important in order to avoid unnecessary surgical intervention. Resolution of the calcification and cortical erosions has not been previously described.


Assuntos
Calcinose/diagnóstico por imagem , Fêmur/diagnóstico por imagem , Tendinopatia/diagnóstico por imagem , Adulto , Doenças Ósseas/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Doenças Musculares/diagnóstico por imagem , Cintilografia , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...