Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Rev Lett ; 126(4): 041301, 2021 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-33576660

RESUMO

We constrain the coupling between axionlike particles (ALPs) and photons, measured with the superconducting resonant detection circuit of a cryogenic Penning trap. By searching the noise spectrum of our fixed-frequency resonant circuit for peaks caused by dark matter ALPs converting into photons in the strong magnetic field of the Penning-trap magnet, we are able to constrain the coupling of ALPs with masses around 2.7906-2.7914 neV/c^{2} to g_{aγ}<1×10^{-11} GeV^{-1}. This is more than one order of magnitude lower than the best laboratory haloscope and approximately 5 times lower than the CERN axion solar telescope (CAST), setting limits in a mass and coupling range which is not constrained by astrophysical observations. Our approach can be extended to many other Penning-trap experiments and has the potential to provide broad limits in the low ALP mass range.

2.
J Biomed Opt ; 23(1): 1-7, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29341541

RESUMO

Manifestation of Cerenkov radiation as a contaminating signal is a significant issue in radiation therapy dose measurement by fiber-coupled scintillator dosimeters. To enhance the scintillation signal transmission while minimizing Cerenkov radiation contamination, we designed a fiber probe using a silver-only coated hollow waveguide (HWG). The HWG with scintillator inserted in its tip, embedded in tissue-mimicking phantoms, was irradiated with clinical electron and photon beams generated by a medical linear accelerator. Optical spectra of the irradiated tip were taken using a fiber spectrometer, and the signal was deconvolved with a linear fitting algorithm. The resultant decomposed spectra of the scintillator with and without Cerenkov correction were in agreement with measurements performed by a standard electron diode and ion chamber for electron and photon beam dosimetry, respectively, indicating the minimal effect of Cerenkov contamination in the HWG-based dosimeter. Furthermore, compared with a silver/dielectric-coated HWG fiber dosimeter design, we observed higher signal transmission in the design based on the use of silver-only HWG.


Assuntos
Fibras Ópticas , Dosímetros de Radiação , Radiometria/instrumentação , Prata/química , Desenho de Equipamento , Imagens de Fantasmas , Análise Espectral
3.
Appl Opt ; 56(35): 9649-9655, 2017 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-29240110

RESUMO

The effect of misalignments of different optical components in the laser heated pedestal growth apparatus have been modeled using Zemax optical design software. By isolating the misalignments causing the non-uniformity in the melt zone, the alignment of the components was fine-tuned. Using this optimized alignment, low-loss YAG single crystal fibers of 120 µm diameter were grown, with total attenuation loss as low as 0.5 dB/m at 1064 nm.

4.
Opt Express ; 24(14): 15522-7, 2016 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-27410826

RESUMO

Single-crystal YAG (Y3Al5O12) fibers have been grown by the laser heated pedestal growth technique with losses as low as 0.3 dB/m at 1.06 µm. These YAG fibers are as long as about 60 cm with diameters around 330 µm. The early fibers were grown from unoriented YAG seed fibers and these fibers exhibited facet steps or ridges on the surface of the fiber. However, recently we have grown fibers using an oriented seed to grow step-free fibers. Scattering losses made on the fibers indicate that the scattering losses are equal to about 30% of the total loss.

5.
Opt Express ; 24(9): 9751-6, 2016 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-27137589

RESUMO

Lasing was demonstrated for the first time at 2.09 µm in 0.5% Holmium (Ho) doped YAG single crystal fiber (SCF) fabricated using the Laser Heated Pedestal Growth (LHPG) method. Output power of 23.5 W with 67.5% optical-to-optical slope efficiency is, to the best of our knowledge, the highest output power achieved at 2 µm from a SCF fabricated using LHPG. With continued improvement in the quality of the SCF and better thermal management, output power of few 100s W and higher, especially in the 2 µm spectral region, is realizable in the very near future.

6.
Appl Opt ; 54(32): 9548-53, 2015 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-26560785

RESUMO

Metal/dielectric-coated hollow glass waveguides (HGWs) have been studied extensively for the efficient transmission of radiation over a broad spectral range. In this study, a low-absorption optical polymer, cyclic olefin copolymer (COC), is investigated as a dielectric material for HGWs designed for the delivery of various IR lasers. Using established silver (Ag) plating techniques and a newly optimized polymer-coating procedure, Ag/COC HGWs with low attenuation coefficients are fabricated for operation at the following three wavelengths: 808 nm, 1.064 µm, and 2.94 µm. The spectral responses of the HGW designs are used to develop a film thickness dependency of the COC layer formation based on the concentration of the solution used in the polymer deposition procedure. Further, the attenuation coefficients of the HGWs are measured using the cutback method at the three wavelengths as a function of the curvature of the waveguide. In order of increasing operation, the attenuation coefficients are measured to be 0.549, 0.095, and 0.298 dB/m for the HGWs in the straight configuration. These experimental values for the straight attenuation coefficients are compared to theoretical values calculated using a ray transfer matrix approach and are found to be in good agreement.

7.
Opt Express ; 22(12): 14896-903, 2014 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-24977584

RESUMO

0.5% Holmium (Ho) doped YAG single crystal fiber (SCF) was fabricated using Laser Heated Pedestal Growth (LHPG) method and characterized for its optical absorption and emission properties involving transitions between the 5I8 and 5I7 energy levels. The results verified the absorption peaks suitable for in-band direct pumping at 1908 nm and 1932 nm with the emission occurring between 2050 and 2150 nm. Small signal gain measurements were also performed for demonstrating the fiber like characteristics of the SCF.

8.
Appl Opt ; 53(4): A70-82, 2014 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-24514252

RESUMO

This analysis explores the theory and design of dielectric multilayer reflection-enhancing thin film stacks based on high and low refractive index alternating layers of cadmium sulfide (CdS) and lead sulfide (PbS) on silver (Ag)-coated hollow glass waveguides (HGWs) for low loss transmission at midinfrared wavelengths. The fundamentals for determining propagation losses in such multilayer thin-film-coated Ag hollow waveguides is thoroughly discussed, and forms the basis for further theoretical analysis presented in this study. The effects on propagation loss resulting from several key parameters of these multilayer thin film stacks is further explored in order to bridge the gap between results predicted through calculation under ideal conditions and deviations from such ideal models that often arise in practice. In particular, the effects on loss due to the number of dielectric thin film layers deposited, deviation from ideal individual layer thicknesses, and surface roughness related scattering losses are presented and thoroughly investigated. Through such extensive theoretical analysis the level of understanding of the underlying loss mechanisms of multilayer thin-film Ag-coated HGWs is greatly advanced, considerably increasing the potential practical development of next-generation ultralow-loss mid-IR Ag/multilayer dielectric-coated HGWs.


Assuntos
Membranas Artificiais , Modelos Químicos , Prata/química , Ressonância de Plasmônio de Superfície/instrumentação , Simulação por Computador , Desenho Assistido por Computador , Impedância Elétrica , Desenho de Equipamento , Análise de Falha de Equipamento , Luz , Espalhamento de Radiação
9.
Opt Express ; 21(20): 23748-55, 2013 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-24104287

RESUMO

A low-loss and low-dispersive optical-fiber-like hybrid HE11 mode is developed within a wide band in metallic hollow waveguides if their inner walls are coated with a thin dielectric layer. We investigate terahertz (THz) transmission losses from 0.5 to 5.5 THz and bending losses at 2.85 THz in a polystyrene-lined silver waveguides with core diameters small enough (1 mm) to minimize the number of undesired modes and to make the waveguide flexible, while keeping the transmission loss of the HE11 mode low. The experimentally measured loss is below 10 dB/m for 2 < ν < 2.85 THz (~4-4.5 dB/m at 2.85 THz) and it is estimated to be below 3 dB/m for 3 < ν < 5 THz according to the numerical calculations. At ~1.25 THz, the waveguide shows an absorption peak of ~75 dB/m related to the transition between the TM11-like mode and the HE11 mode. Numerical modeling reproduces the measured absorption spectrum but underestimates the losses at the absorption peak, suggesting imperfections in the waveguide walls and that the losses can be reduced further.

10.
Appl Opt ; 52(27): 6703-9, 2013 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-24085169

RESUMO

This study involves the fabrication and characterization of improved quality silver (Ag)/polystyrene (PS) thin-film-coated hollow-glass waveguides for the low-loss transmission of terahertz radiation via modified dynamic liquid phase deposition techniques. High-quality PS thin films were deposited from aqueous PS solutions, and the spectral response of fabricated samples was measured from λ=1-100 µm. Fabricated samples exhibited highly defined spectral responses throughout this entire range indicative of PS films of excellent quality. The spectra of experimental samples were compared to the theoretical and bulk PS spectra in the near-IR and far-IR regions. The thickness of deposited PS thin films was found to depend on total sample length and to vary from approximately 10-16 µm for sample lengths ranging from 115 to 140 cm. Such PS film thicknesses are adequate for low-loss delivery from approximately 2-4 THz. Furthermore, film thickness was found to vary minimally along the waveguide length regardless of total sample length.

11.
Appl Opt ; 52(16): 3703-12, 2013 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-23736323

RESUMO

Silver/silver halide-coated hollow-glass waveguides (HGWs) are capable of low-loss, broadband transmission at infrared wavelengths with the advantage of optical response tunability through alteration of a number of key design parameters. Generally, the design of circular HGWs has primarily involved optimization of the waveguide bore size and deposited film structure in order to obtain the desired optical response, with the waveguide bore size being held constant as a function of length. In this study, the effects of HGW structures consisting of linearly tapered inner diameters on the optical response at infrared wavelengths are theoretically and experimentally investigated. Theoretical analysis involving numerical ray optics methods accounting for the dynamic nature of bore size, and consequently light propagation, along the waveguide length is presented and compared to experimental results in order to gain a deeper understanding of these atypical HGW structures.

12.
Sensors (Basel) ; 13(1): 1329-40, 2013 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-23337336

RESUMO

We report on single mode optical transmission of hollow core glass waveguides (HWG) coupled with an external cavity mid-IR quantum cascade lasers (QCLs). The QCL mode results perfectly matched to the hybrid HE(11) waveguide mode and the higher losses TE-like modes have efficiently suppressed by the deposited inner dielectric coating. Optical losses down to 0.44 dB/m and output beam divergence of ~5 mrad were measured. Using a HGW fiber with internal core size of 300 µm we obtained single mode laser transmission at 10.54 µm and successful employed it in a quartz enhanced photoacoustic gas sensor setup.

13.
Appl Opt ; 51(16): 3114-9, 2012 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-22695541

RESUMO

Hollow glass waveguides, composed of Ag/AgI coatings, have been studied at 10.6 µm. The losses for different bore sizes equal the theoretical loss, which for the 700 µm bore guide was about 0.15 dB/m. The losses for the guides increase upon bending, varying linearly with increasing curvature. These hollow guides propagate a single mode when the bore size of the guide is approximately 30λ. In addition, the best single-mode transmission is obtained when the thickness of the glass wall is large. These smaller bores, thick wall hollow guides, can also be used to filter higher order modes from poor quality input laser beams.

14.
J Biophotonics ; 4(4): 219-23, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20635429

RESUMO

This study's objective is to validate a method for the measurement of two compound phantoms as a proof of concept for oxygen saturation level measurement via a thermal imaging bundle. The method consists of a thermal imaging system and an algorithm which estimates the compound concentration according to temperature rise. A temperature rise is obtained by illuminating the tissue with a laser with different wavelengths in the NIR range and measured using a thermal camera. A coherent thermal imaging bundle was used for image transmittance for minimal invasive transendoscopic use. The algorithm's estimation ability was evaluated using agar phantoms of varying Methylene Blue and ICG ratios as well as blood samples The Methylene Blue ratio in each phantom was estimated and the calculated average RMS of the error was 9.38%, a satisfying value for this stage, verifying the algorithm's and bundle's suitability for the use in a minimal invasive system.


Assuntos
Oxigênio/análise , Imagens de Fantasmas , Termografia/métodos , Algoritmos , Tecnologia de Fibra Óptica/instrumentação , Humanos , Verde de Indocianina , Azul de Metileno , Oxigênio/sangue , Oxigênio/metabolismo , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Temperatura , Termografia/instrumentação
15.
Opt Express ; 18(3): 1898-903, 2010 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-20174017

RESUMO

Thin dielectric layers deposited on the inner surface of hollow cylindrical metallic waveguides for Terahertz (THz) waves reduce transmission losses below 1 dB/m. Impact of the dielectric layer on the waveguide dispersion is experimentally investigated by near-field mapping of guided short THz pulses at the input and the output of the waveguide. We obtain dispersion characteristics for the low-loss waveguide modes, the linearly-polarized HE(11) mode and the TE(01) mode, and compare the experimental results to the metallic waveguide dispersion. The additional dispersion due to the dielectric layer is found to be small for the HE(11) mode and the phase velocity is primarily determined by the waveguide radius.

16.
Appl Opt ; 48(16): 3050-4, 2009 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-19488117

RESUMO

Low- and high-refractive-index chalcogenide glasses are studied for their potential use in the fabrication of one-dimensional hollow Bragg fibers. The low-index glasses are based on the GeSe-glass systems with indices varying from 2.0 to 2.5, while the high-index glasses are formed from the AgAsSe glasses with indices ranging from 2.8 to 3.8. High-purity elemental starting materials are distilled and the surface oxides removed prior to mixing in a rocking furnace. The refractive indices of the AgAsSe glasses, measured using a CO2 laser reflectometer, were near 3.10 for the compositions most compatible with the low-index Ge20Se80 glass (n = 2.46). Spectral measurements show impurity absorption bands between 12 and 16 microm. The loss at 10.6 microm for the Ag25As40Se35 glass measured using CO2 laser calorimetry was 1.16 x 10(-3) cm(-1).

17.
Opt Lett ; 32(20): 2945-7, 2007 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-17938661

RESUMO

We have applied techniques developed for IR waveguides to fabricate Ag/polystyrene (PS) -coated hollow glass waveguides (HGWs) for transmission of terahertz radiation. A loss of 0.95 dB/m at 119 microm (2.5 THz) was obtained for a 2 mm bore, 90 cm long Ag/PS HGW. We found that TE modes are supported in HGWs with thin PS films, while hybrid (HE) modes dominate when PS film thickness increases. The lowest losses are obtained for the thicker PS films and the propagation of the HE modes.

18.
Appl Opt ; 44(30): 6449-55, 2005 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-16252656

RESUMO

Hollow polycarbonate waveguides with thin-film coatings of Ag-AgI were fabricated by liquid-phase chemistry methods. These hollow waveguides, which have bore sizes ranging from 500 to 2000 microm and lengths as long as 2 m, are transmissive from 2 to more than 20 microm. The lowest loss of 0.02 dB/m was obtained for a straight 2000 microm bore guide at 10.6 microm. This is to our knowledge the lowest loss measured for any IR fiber at CO2 laser wavelengths. The bending losses were found to increase as 1/R, where R is the radius of the bend. These waveguides were able to withstand 18 W of CO2 laser input power for bore sizes greater than 1000 microm.

19.
Appl Opt ; 43(10): 2039-45, 2004 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-15074410

RESUMO

An all-fiber-optic infrared multispectral radiometer for measurements of temperature and emissivity of graybodies at near-room temperature was constructed. Different spectral regions in the radiometer were obtained by use of hollow glass waveguides (HGWs) as filters. Using HGWs instead of bulk filters was advantageous because each HGW can be used as two different spectral filters when a dual-band IR detector is used. In addition, HGWs are much cheaper than the bulk IR filters that are usually used in such applications. For one graybody with a mean emissivity of 0.71, the estimated mean errors obtained for sample temperature, ambient temperature, and sample emissivity for all measured temperatures were 0.50% (approximately 1.65 K), 0.48% (approximately 1.4 K), and 7.3% (approximately 0.052) respectively. For a second graybody with a mean emissivity of 0.8 the estimated mean errors were 0.35% (approximately 1.2 K), 0.48% (approximately 1.4 K), and 5.0% (approximately 0.04), respectively.

20.
Appl Opt ; 43(11): 2231-5, 2004 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-15098823

RESUMO

Hollow glass waveguides with bores tapered from 1000 to 500 microm and from 700 to 500 microm over a length of 2 m were coated with silver and silver iodide inner films. These waveguides were designed for low attenuation at the 10.6-microm CO2 laser wavelength. The straight losses, which were measured to be 0.8 and 1.6 dB/m, respectively, decreased when the guides were bent. A simple ray-trajectory model is presented to explain this unexpected behavior.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...