Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Opt Express ; 32(12): 21925-21935, 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38859534

RESUMO

We present a low-loss, compact, hollow core optical fibre (HCF) cell integrated with single mode fibre (SMF). The cell is designed to be filled with atomic vapour and used as a component in photonic quantum technologies, with applications in quantum memory and optical switching. We achieve a total insertion loss of 0.6(2) dB at 780 nm wavelength via graded index fibre to ensure efficient mode matching coupled with anti-reflection coatings to minimise loss at the SMF-HCF interfaces. We also present numerical modelling of these interfaces, which can be undertaken efficiently without the need for finite element simulation. We encapsulate the HCF core by coupling to the SMF inside a support capillary, enhancing durability and facilitating seamless integration into existing fibre platforms.

2.
Opt Lett ; 49(11): 3090-3093, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38824335

RESUMO

Tunable ultrashort pulses in the ultraviolet spectral region are in great demand for a wide range of applications, including spectroscopy and pump-probe experiments. While laser sources capable of producing such pulses exist, they are typically very complex. Notably, resonant dispersive-wave (RDW) emission has emerged as a simple technique for generating such pulses. However, the required pulse energy used to drive the RDW emission, so far, is mostly at the microjoule level, requiring complicated and expensive pump sources. Here, we present our work on lowering the pump energy threshold for generating tuneable deep ultraviolet pulses to the level of tens of nanojoules. We fabricated a record small-core antiresonant fiber with a hollow-core diameter of just 6 µm. When filled with argon, the small mode area enables higher-order soliton propagation and deep ultraviolet (220 to 270 nm) RDW emission from 36 fs pump pulses at 515 nm with the lowest pump energy reported to date (tens of nanojoules). This approach will allow the use of low-cost and compact laser oscillators to drive nonlinear optics in gas-filled fibers for the first time to our knowledge.

3.
Opt Express ; 32(6): 8520-8526, 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38571109

RESUMO

We report an anti-resonant hollow core fibre with ultraviolet transmission down to 190 nm, covering the entire UV-A, UV-B and much of the UV-C band. Guidance from 190 - 400 nm is achieved apart for a narrow high loss resonance band at 245 - 265 nm. The minimum attenuation is 0.13 dB/m at 235 nm and 0.16 dB/m at 325 nm. With an inscribed core diameter of ∼12 µm, the fibre's bend loss at 325 nm was 0.22 dB per turn for a bend radius of 3 cm at 325 nm.

4.
Opt Express ; 32(1): 922-931, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38175113

RESUMO

We present a method with potential for fabricating freeform air-silica optical fibre preforms which is free from the stacking constraints associated with conventional stack-and-draw. The method, termed Axi-Stack, is enabled by the precision machining of short cross-sectional preform discs by ultrafast laser assisted etching; a laser-based microfabrication technique which facilitates near arbitrary shaping of the preform structure. Several preform discs are stacked axially and fused together via ultrafast laser welding to construct the preform, which can be drawn to fibre using conventional methods. To illustrate the Axi-Stack process, we detail the fabrication of a 30 cm long solid-core photonic crystal fibre preform with a square lattice of cladding holes and characterise fibre drawn from it.

5.
R Soc Open Sci ; 10(2): 221236, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36756063

RESUMO

Making user interaction with laboratory equipment more convenient and intuitive should promote experimental work and help researchers to complete their tasks efficiently. The most common form of interaction in current instrumentation is either direct tactile, with buttons and knobs, or interfaced through a computer, using a mouse and keyboard. Scripting is another function typical of smart and automated laboratory equipment, yet users are currently required to learn bespoke programming languages and libraries for individual pieces of equipment. In this paper, we present two open-source, novel and intuitive ways of interacting with and scripting laboratory equipment. We choose the OpenFlexure family of microscopes as our exemplar, due to their open-source nature and smart control system. Firstly, we demonstrate 'OpenFlexure Voice Control' to enable users to control the microscope hands-free. Secondly, we present 'OpenFlexure Blockly' which uses the Blockly Visual Programming Language to enable users to easily create scripts for the microscope, using a drag and drop Web interface. We explain the design choices when developing these tools, and discuss more typical use cases and more general applications.

6.
Eur J Nucl Med Mol Imaging ; 48(3): 800-807, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32915268

RESUMO

PURPOSE: The relentless rise in antimicrobial resistance is a major societal challenge and requires, as part of its solution, a better understanding of bacterial colonization and infection. To facilitate this, we developed a highly efficient no-wash red optical molecular imaging agent that enables the rapid, selective, and specific visualization of Gram-positive bacteria through a bespoke optical fiber-based delivery/imaging endoscopic device. METHODS: We rationally designed a no-wash, red, Gram-positive-specific molecular imaging agent (Merocy-Van) based on vancomycin and an environmental merocyanine dye. We demonstrated the specificity and utility of the imaging agent in escalating in vitro and ex vivo whole human lung models (n = 3), utilizing a bespoke fiber-based delivery and imaging device, coupled to a wide-field, two-color endomicroscopy system. RESULTS: The imaging agent (Merocy-Van) was specific to Gram-positive bacteria and enabled no-wash imaging of S. aureus within the alveolar space of whole ex vivo human lungs within 60 s of delivery into the field-of-view, using the novel imaging/delivery endomicroscopy device. CONCLUSION: This platform enables the rapid and specific detection of Gram-positive bacteria in the human lung.


Assuntos
Fibras Ópticas , Staphylococcus aureus , Endoscópios , Bactérias Gram-Positivas , Humanos , Pulmão/diagnóstico por imagem
7.
Sensors (Basel) ; 20(21)2020 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-33121191

RESUMO

Numerous optodes, with fluorophores as the chemical sensing element and optical fibres for light delivery and collection, have been fabricated for minimally invasive endoscopic measurements of key physiological parameters such as pH. These flexible miniaturised optodes have typically attempted to maximize signal-to-noise through the application of high concentrations of fluorophores. We show that high-density attachment of carboxyfluorescein onto silica microspheres, the sensing elements, results in fluorescence energy transfer, manifesting as reduced fluorescence intensity and lifetime in addition to spectral changes. We demonstrate that the change in fluorescence intensity of carboxyfluorescein with pH in this "high-density" regime is opposite to that normally observed, with complex variations in fluorescent lifetime across the emission spectra of coupled fluorophores. Improved understanding of such highly loaded sensor beads is important because it leads to large increases in photostability and will aid the development of compact fibre probes, suitable for clinical applications. The time-resolved spectral measurement techniques presented here can be further applied to similar studies of other optodes.

8.
Opt Express ; 28(13): 19126-19132, 2020 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-32672196

RESUMO

Optical fibers with a logarithmic index profile can provide invariant mode field diameters along a tapered fiber, which enables adiabatic mode transitions for higher-order mode (HOM) microfibers. A microfiber with a waist diameter of ∼2 µm is fabricated with an insertion loss lower than 0.03 dB for the LP01 and 0.11 dB for the LP11 mode. The concept of the low loss HOM microfibers can be further extended to include more than one fiber and a 2×2 few mode microfiber coupler is fabricated/characterized in our experiments. These single or multiple spatial channel HOM microfibers are beneficial for various applications, including in particle propulsion, atom trapping, optical sensing and space division multiplexed data transmission systems.

9.
Phys Rev Lett ; 124(15): 153902, 2020 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-32357029

RESUMO

We observe clear evidence of adiabatic passage between photon populations via a four-wave mixing process, implemented through a dispersion sweep arranged by a core diameter taper of an optical fiber. Photonic rapid adiabatic passage through the cubic electric susceptibility thus opens precise control of frequency translation between broadband light fields to all common optical media. Areas of potential impact include optical fiber and on-chip waveguide platforms for quantum information, ultrafast spectroscopy and metrology, and extreme light-matter interaction science.

10.
Opt Lett ; 45(10): 2716-2719, 2020 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-32412449

RESUMO

A robust method to selectively attach specific fluorophores onto the individual cores of a multicore fiber is reported in this Letter. The method is based on the use of ultrafast laser pulses to nanostructure the facet of the fiber core, followed by amine functionalization and sensor conjugation. This surface-machining protocol not only enables precise spatial selectivity, but it also facilitates high deposition densities of the sensor moieties. As a proof of concept, the successful deposition of three different fluorophores onto selected cores of a multicore fiber is demonstrated. The protocol was developed to include attachment of a fluorescence-based pH sensor using the ratiometric carboxynapthofluorescein.

11.
Opt Express ; 28(4): 4763-4772, 2020 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-32121708

RESUMO

As 3D printers become more widely available, researchers are able to rapidly produce components that may have previously taken weeks to have machined. The resulting plastic components, having high surface roughness, are often not suitable for high-precision optomechanics. However, by playing to the strengths of 3D printing-namely the ability to print complex internal geometries-it is possible to design monolithic mechanisms that do not rely on tight integration of high-precision parts. Here we present a motorised monolithic 3D-printed plastic flexure stage with sub-100 nm resolution that can perform automated optical fibre alignment.

12.
Sci Rep ; 9(1): 7713, 2019 05 22.
Artigo em Inglês | MEDLINE | ID: mdl-31118459

RESUMO

Physiological sensing deep in tissue remains a clinical challenge. Here a flexible miniaturised sensing optrode providing a platform to perform minimally invasive in vivo in situ measurements is reported. Silica microspheres covalently coupled with a high density of ratiometrically configured fluorophores were deposited into etched pits on the distal end of a 150 µm diameter multicore optical fibre. With this platform, photonic measurements of pH and oxygen concentration with high precision in the distal alveolar space of the lung are reported. We demonstrated the phenomenon that high-density deposition of carboxyfluorescein covalently coupled to silica microspheres shows an inverse shift in fluorescence in response to varying pH. This platform delivered fast and accurate measurements (±0.02 pH units and ±0.6 mg/L of oxygen), near instantaneous response time and a flexible architecture for addition of multiple sensors.


Assuntos
Tecnologia de Fibra Óptica/métodos , Fibras Ópticas , Alvéolos Pulmonares/diagnóstico por imagem , Animais , Broncoscopia , Feminino , Fluoresceínas/análise , Corantes Fluorescentes/análise , Concentração de Íons de Hidrogênio , Microscopia Eletrônica de Varredura , Microesferas , Miniaturização , Oxigênio , Rodaminas/análise , Ovinos , Dióxido de Silício
13.
Analyst ; 142(19): 3569-3572, 2017 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-28853485

RESUMO

The fabrication of fluorescence-based pH sensors, embedded into etched pits of an optical fibre via highly controllable and spatially selective photo-polymerisation is described and the sensors validated.

14.
Opt Express ; 25(3): 1985-1992, 2017 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-29519047

RESUMO

We describe a technique for the quantitative characterization of endoscopic imaging fibers using an interference pattern as the standard object to be imaged. The visibility of the pattern at the other end of the fiber is then analyzed as wavelength and fringe period are varied. We demonstrate the use of the technique by comparing three fibers: two fabricated in-house from the same preform, designed to minimize inter-core coupling at visible wavelengths less than 650 nm, and a commercial imaging fiber. The techniques discussed are currently being used to optimize fibers for fluorescence bronchoscopy to be used in intensive care clinics.


Assuntos
Endoscopia/métodos , Tecnologia de Fibra Óptica/instrumentação , Fibras Ópticas , Desenho de Equipamento , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...