Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
1.
Neth Heart J ; 32(6): 254-261, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38776038

RESUMO

BACKGROUND: Several ethnic minorities have an increased risk of cardiovascular events, but previous European trials that investigated clinical outcome after coronary stenting did not assess the patients' ethnic background. AIMS: To compare ethnic minority and Western European trial participants in terms of both cardiovascular risk profile and 1­year clinical outcome after percutaneous coronary intervention. METHODS: In the BIO-RESORT and BIONYX randomised trials, which assessed new-generation drug-eluting stents, information on patients' self-reported ethnic background was prospectively collected. Pooled patient-level data of 5803 patients, enrolled in the Netherlands and Belgium, were analysed in this prespecified analysis. The main endpoint was target vessel failure after 1 year. RESULTS: Patients were classified as belonging to an ethnic minority (n = 293, 5%) or of Western European origin (n = 5510, 95%). Follow-up data were available in 5772 of 5803 (99.5%) patients. Ethnic minority patients were younger, less often female, more often current smokers, more often medically treated for diabetes, and more often had a positive family history of coronary artery disease. The main endpoint target vessel failure did not differ between ethnic minority and Western European patients (3.5% vs 4.9%, hazard ratio 0.71, 95% confidence interval 0.38-1.33; p = 0.28). There was also no difference in mortality, myocardial infarction, and repeat revascularisation rates. CONCLUSIONS: Despite the unfavourable cardiovascular risk profile of ethnic minority patients, short-term clinical outcome after treatment with contemporary drug-eluting stents was highly similar to that in Western European patients. Further efforts should be made to ensure the enrolment of more ethnic minority patients in future coronary stent trials.

2.
Atherosclerosis ; 392: 117488, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38598970

RESUMO

BACKGROUND AND AIMS: Previous studies in percutaneous coronary intervention (PCI) patients showed a higher 3-year adverse event risk, including all-cause mortality, in those with concomitant peripheral arterial disease (PADs). Ten-year data of mortality and causes of death are scarce. This analysis assessed PCI patients, treated with contemporary drug-eluting stents, the impact of concomitant PADs on very long-term mortality, and causes of death. METHODS: We assessed PCI all-comers from our center who participated in the TWENTE and DUTCH PEERS trials (clinicaltrials.gov:NCT01066650, NCT01331707), comparing patients with versus without PADs. Life status was checked in the Dutch Personal Records Database; causes of death were obtained from medical records. RESULTS: Of 2705 study patients, 668 (24.7%) died during follow-up: 88/212 (41.5%) patients with PADs and 580/2493 (23.1%) without PADs. In PADs patients, the 10-year rate of all-cause mortality was about twice as high as in patients without PADs (41.5% vs.23.1%, HR: 2.05, 95%-CI: 1.64-2.57, p<0.001). For both groups, the rates of patients dying from various causes of death were: cardiac (14.1% vs.6.8%), vascular (2.8% vs. 1.1%), non-cardiovascular (17.4% vs. 9.8%), and unclear causes (7.1% vs. 5.3%), without a statistically significant between-group difference. When multivariate analysis was adjusted for between-group differences in cardiovascular risk profile, PADs remained predictor of all-cause mortality (adjusted HR: 1.38, 95%-CI: 1.08-1.75, p=0.01). CONCLUSIONS: The 10-year all-cause mortality rate in PCI patients with concomitant PADs was almost twice as high as in those without PADs. Age and other traditional cardiovascular risk factors were higher in patients with PADs, but after correction for these confounders PADs still accounted for almost 40% increase in mortality.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Doença Arterial Periférica , Humanos , Doença Arterial Periférica/mortalidade , Doença Arterial Periférica/terapia , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/complicações , Fatores de Tempo , Resultado do Tratamento , Fatores de Risco , Países Baixos/epidemiologia , Causas de Morte
3.
Front Cardiovasc Med ; 10: 1160201, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37745109

RESUMO

Objectives: We assessed differences in risk profile and 3-year outcome between patients undergoing percutaneous coronary intervention (PCI) for premature and non-premature coronary artery disease (CAD). Background: The prevalence of CAD increases with age, yet some individuals develop obstructive CAD at younger age. Methods: Among participants in four randomized all-comers PCI trials, without previous coronary revascularization or myocardial infarction (MI), we compared patients with premature (men <50 years; women <55 years) and non-premature CAD. Various clinical endpoints were assessed, including multivariate analyses. Results: Of 6,171 patients, 887 (14.4%) suffered from premature CAD. These patients had fewer risk factors than patients with non-premature CAD, but were more often smokers (60.7% vs. 26.4%) and overweight (76.2% vs. 69.8%). In addition, premature CAD patients presented more often with ST-segment elevation MI and underwent less often treatment of multiple vessels, and calcified or bifurcated lesions. Furthermore, premature CAD patients had a lower all-cause mortality risk (adj.HR: 0.23, 95%-CI: 0.10-0.52; p < 0.001), but target vessel revascularization (adj.HR: 1.63, 95%-CI: 1.18-2.26; p = 0.003) and definite stent thrombosis risks (adj.HR: 2.24, 95%-CI: 1.06-4.72; p = 0.034) were higher. MACE rates showed no statistically significant difference (6.6% vs. 9.4%; adj.HR: 0.86, 95%-CI: 0.65-1.16; p = 0.33). Conclusions: About one out of seven PCI patients was treated for premature CAD. These patients had less complex risk profiles than patients with non-premature CAD; yet, their risk of repeated revascularization and stent thrombosis was higher. As lifetime event risk of patients with premature CAD is known to be particularly high, further efforts should be made to improve modifiable risk factors such as smoking and overweight. TWENTE trials: (TWENTE I, clinicaltrials.gov: NCT01066650), DUTCH PEERS (TWENTE II, NCT01331707), BIO-RESORT (TWENTE III, NCT01674803), and BIONYX (TWENTE IV, NCT02508714).

4.
Eur Heart J Acute Cardiovasc Care ; 12(11): 774-781, 2023 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-37619976

RESUMO

AIMS: Patients with premature coronary artery disease (CAD) have a higher incidence of myocardial infarction (MI) than patients with non-premature CAD. The aim of the present study is to asess differences in clinical outcome after a first acute MI, percutaneously treated with new-generation drug-eluting stents between patients with premature and non-premature CAD. METHODS AND RESULTS: We pooled and analysed the characteristics and clinical outcome of all patients with a first MI (and no previous coronary revascularization) at time of enrolment, in four large-scale drug-eluting stent trials. Coronary artery disease was classified premature in men aged <50 and women <55 years. Myocardial infarction patients with premature and non-premature CAD were compared. The main endpoint was major adverse cardiac events (MACE): all-cause mortality, any MI, emergent coronary artery bypass surgery, or clinically indicated target lesion revascularization. Of 3323 patients with a first MI, 582 (17.5%) had premature CAD. These patients had lower risk profiles and underwent less complex interventional procedures than patients with non-premature CAD. At 30-day follow-up, the rates of MACE [hazard ratio (HR): 0.22, 95% confidence interval (CI): 0.07-0.71; P = 0.005), MI (HR: 0.22, 95% CI: 0.05-0.89; P = 0.020), and target vessel failure (HR: 0.30, 95% CI: 0.11-0.82; P = 0.012) were lower in patients with premature CAD. At 1 year, premature CAD was independently associated with lower rates of MACE (adjusted HR: 0.50, 95% CI: 0.26-0.96; P = 0.037) and all-cause mortality (adjusted HR: 0.24, 95% CI: 0.06-0.98; P = 0.046). At 2 years, premature CAD was independently associated with lower mortality (adjusted HR: 0.16, 95% CI: 0.05-0.50; P = 0.002). CONCLUSIONS: First MI patients with premature CAD, treated with contemporary stents, showed lower rates of MACE and all-cause mortality than patients with non-premature CAD, which is most likely related to differences in cardiovascular risk profile. TWENTE trials: TWENTE I, clinicaltrials.gov: NCT01066650), DUTCH PEERS (TWENTE II, NCT01331707), BIO-RESORT (TWENTE III, NCT01674803), and BIONYX (TWENTE IV, NCT02508714).


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Infarto do Miocárdio , Intervenção Coronária Percutânea , Feminino , Humanos , Masculino , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/cirurgia , Stents Farmacológicos/efeitos adversos , Infarto do Miocárdio/epidemiologia , Infarto do Miocárdio/cirurgia , Infarto do Miocárdio/tratamento farmacológico , Intervenção Coronária Percutânea/métodos , Fatores de Risco , Resultado do Tratamento , Pessoa de Meia-Idade
5.
J Am Heart Assoc ; 11(22): e026041, 2022 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-36346050

RESUMO

Background In a previous trial, higher 5-year mortality was observed following treatment with biodegradable polymer Orsiro sirolimus-eluting stents (SES). We assessed 5-year safety and efficacy of all-comers as well as patients with diabetes treated with SES or Synergy everolimus-eluting stents (EES) versus durable polymer Resolute Integrity zotarolimus-eluting stents (ZES). Methods and Results The randomized BIO-RESORT (Comparison of Biodegradable Polymer and Durable Polymer Drug-Eluting Stents in an All Comers Population) trial enrolled 3514 all-comer patients at 4 Dutch cardiac centers. Patients aged ≥18 years who required percutaneous coronary intervention were eligible. Participants were stratified for diabetes and randomized to treatment with SES, EES, or ZES (1:1:1). The main end point was target vessel failure (cardiac mortality, target vessel myocardial infarction, or target vessel revascularization). Five-year follow-up was available in 3183 of 3514 (90.6%) patients. The main end point target vessel failure occurred in 142 of 1169 (12.7%) patients treated with SES, 130 of 1172 (11.6%) treated with EES, versus 157 of 1173 (14.1%) treated with ZES (hazard ratio [HR], 0.89 [95% CI, 0.71-1.12], Plog-rank=0.31; and HR, 0.82 [95% CI, 0.65-1.04], Plog-rank=0.10, respectively). Individual components of target vessel failure showed no significant between-stent difference. Very late definite stent thrombosis rates were low and similar (SES, 1.1%; EES, 0.6%; ZES, 0.9%). In patients with diabetes, target vessel failure did not differ significantly between stent-groups (SES, 19.8%; EES, 19.2%; versus ZES, 21.1% [Plog-rank=0.69 and Plog-rank=0.63]). Conclusions Orsiro SES, Synergy EES, and Resolute Integrity ZES showed similar 5-year outcomes of safety and efficacy, including mortality. A prespecified stent comparison in patients with diabetes also revealed no significant differences in 5-year clinical outcomes. Registration URL: https://www.clinicaltrials.gov; Unique identifier: NCT01674803.


Assuntos
Doença da Artéria Coronariana , Diabetes Mellitus , Stents Farmacológicos , Intervenção Coronária Percutânea , Humanos , Adolescente , Adulto , Desenho de Prótese , Resultado do Tratamento , Everolimo , Intervenção Coronária Percutânea/efeitos adversos , Polímeros , Diabetes Mellitus/etiologia , Doença da Artéria Coronariana/cirurgia , Doença da Artéria Coronariana/etiologia
6.
Catheter Cardiovasc Interv ; 98(2): E188-E196, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-33694294

RESUMO

OBJECTIVES: To compare 2-year outcome following treatment with drug-eluting stents (DES) for acute myocardial infarction (MI) versus non-MI clinical syndromes. In acute MI patients, a stent-level comparison was performed, comparing Resolute Onyx versus Orsiro stents. BACKGROUND: In patients presenting with acute MI, higher adverse event rates have been reported. So far, no clinical results >1 year have been published of acute MI patients treated with Resolute Onyx. METHODS: This post-hoc analysis of the randomized BIONYX trial(NCT02508714) assessed the main outcome target vessel failure (TVF: cardiac death, target vessel MI, or target vessel revascularization) with Kaplan-Meier methods. RESULTS: Of all 2,488 trial participants, acute MI patients (n = 1,275[51.2%]) were significantly younger and had less comorbidities than non-MI patients (n = 1,213[48.8%]). TVF rates were lower in acute MI patients (77/1,275[6.1%] vs. 103/1,213[8.6%], HR:0.70, 95%-CI 0.52-0.94; plog-rank  = 0.02), mainly driven by target vessel revascularization (4.1 vs. 6.1%, plog-rank  = 0.03). Multivariate analysis showed no independent association of clinical syndrome with TVF (adjusted-HR: 0.81, 95%-CI 0.60-1.10; p = .17). In MI patients treated with Resolute Onyx (n = 626) versus Orsiro (n = 649), there was no difference in TVF (6.2 vs. 6.1%; plog-rank  = 0.97) and its components. There was only 1(0.2%) definite-or-probable stent thrombosis in RO-ZES and 8(1.2%) in O-SES (p = .053). CONCLUSIONS: Two years after treatment with thin-strut DES in this randomized trial, patients treated for acute MI had lower adverse event rates than non-MI patients. Yet, these findings were mainly attributable to between-group differences in patient and lesion characteristics. In patients who underwent PCI for acute MI, both Resolute Onyx and Orsiro showed favorable and similar 2-year outcomes.


Assuntos
Stents Farmacológicos , Infarto do Miocárdio , Intervenção Coronária Percutânea , Everolimo , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Sirolimo , Stents , Resultado do Tratamento
7.
Coron Artery Dis ; 32(1): 51-57, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33278175

RESUMO

BACKGROUND: Treatment of a coronary bifurcation lesion is often required in routine clinical practice, but data on the performance of very thin-strut biodegradable polymer drug-eluting stents are scarce. METHODS: Comparison of biodegradable polymer and durable polymer drug-eluting stents in an all comers population (BIO-RESORT) is a prospective, multicenter randomized clinical trial that included 3514 all-comer patients, who were randomized to very thin-strut biodegradable polymer-coated sirolimus- or everolimus-eluting stents, versus thin-strut durable polymer-coated zotarolimus-eluting stents. The approach of bifurcation stenting was left at the operator's discretion, and provisional stenting was generally preferred. This prespecified analysis assessed 3-year clinical outcome of all patients in whom treatment involved at least one bifurcation with a side-branch diameter ≥1.5 mm. RESULTS: Of all BIO-RESORT trial participants, 1236 patients were treated in bifurcation lesions and analyzed. Single- and two-stent techniques were used in 85.8% and 14.2%, respectively. 'True' bifurcation lesions (main vessel and side-branch obstructed) were treated in 31.1%. Three-year follow-up was available in 1200/1236 (97.1%) patients. The main endpoint target vessel failure (composite of cardiac death, target vessel-related myocardial infarction, or target vessel revascularization) occurred in sirolimus-eluting stents in 42/412 (10.3%) and in zotarolimus-eluting stents in 49/409 (12.1%) patients (P-logrank = 0.40). In everolimus-eluting stents, target vessel failure occurred in 40/415 (9.8%) patients (vs. zotarolimus-eluting stents: P-logrank = 0.26). There was no between-stent difference in individual components of target vessel failure. Findings were consistent in patients with single-vessel treatment and patients treated with a single-stent technique. CONCLUSIONS: Three years after stenting all-comers with bifurcation lesions, clinical outcome was similar with the sirolimus-eluting and everolimus-eluting stents versus the zotarolimus-eluting stent.


Assuntos
Doença da Artéria Coronariana , Vasos Coronários , Stents Farmacológicos , Everolimo/uso terapêutico , Efeitos Adversos de Longa Duração , Falha de Prótese , Sirolimo/análogos & derivados , Plásticos Biodegradáveis/uso terapêutico , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/cirurgia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Stents Farmacológicos/efeitos adversos , Stents Farmacológicos/classificação , Análise de Falha de Equipamento , Feminino , Humanos , Imunossupressores/uso terapêutico , Efeitos Adversos de Longa Duração/epidemiologia , Efeitos Adversos de Longa Duração/etiologia , Efeitos Adversos de Longa Duração/terapia , Masculino , Pessoa de Meia-Idade , Avaliação de Processos e Resultados em Cuidados de Saúde , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Intervenção Coronária Percutânea/métodos , Falha de Prótese/efeitos adversos , Falha de Prótese/etiologia , Sirolimo/uso terapêutico
8.
Int J Cardiol ; 325: 37-44, 2021 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-33148427

RESUMO

BACKGROUND: Patients with diabetes have more extensive coronary disease, resulting in higher risks of adverse clinical events following stenting. In all-comer patients, contemporary DES have shown excellent safety and efficacy, but data on diabetic patients are scarce. Separately for the BIO-RESORT and BIONYX trials, we assessed the 2-year clinical outcomes of diabetic patients, treated with various contemporary drug-eluting stents (DES). METHODS: We performed two prespecified secondary analyses of two randomized DES trials, which both stratified for diabetes. The main endpoint was target vessel failure (TVF), a composite of cardiac death, target vessel myocardial infarction, or target vessel revascularization. Follow-up was finished before the COVID-19 pandemic. RESULTS: In BIO-RESORT, 624/3514 (17.8%) had diabetes: 211 received Orsiro sirolimus-eluting stents (SES), 203 Synergy everolimus-eluting stents (EES), and 210 Resolute Integrity zotarolimus-eluting stents (RI-ZES). TVF did not differ between SES (10.2%) and EES (10.0%) versus RI-ZES (12.7%) (SES vs. RI-ZES HR:0.78, 95%-CI [0.44-1.40]; p = 0.40, EES vs. RI-ZES HR:0.79, 95%-CI [0.44-1.40]; p = 0.42). In BIONYX, 510/2488 (20.5%) patients had diabetes: 250 received SES and 260 Resolute Onyx zotarolimus-eluting stents (RO-ZES). There was no difference in TVF between SES (10.7%) versus RO-ZES (12.2%) (HR:0.88, 95%-CI [0.52-1.48]; p = 0.63). CONCLUSIONS: There was no difference in 2-year clinical outcome among patients with diabetes, who were treated with SES, or EES, versus RI-ZES. In addition there was no difference in clinical outcome in diabetic patients, who were treated with SES versus RO-ZES. These findings may be considered as a signal of safety and efficacy of the studied DES in patients with diabetes.


Assuntos
Diabetes Mellitus/tratamento farmacológico , Stents Farmacológicos , Everolimo/administração & dosagem , Sirolimo/análogos & derivados , Plásticos Biodegradáveis , Humanos , Estudos Multicêntricos como Assunto , Desenho de Prótese , Ensaios Clínicos Controlados Aleatórios como Assunto , Projetos de Pesquisa , Sirolimo/administração & dosagem
9.
Am Heart J ; 228: 109-115, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32882569

RESUMO

BACKGROUND: Patients aged ≥80 years are often treated with new-generation drug-eluting stents (DES), but data from randomized studies are scarce owing to underrepresentation in most trials. We assessed 1-year clinical outcome of octogenarians treated with new-generation DES versus younger patients. METHODS: We pooled patient-level data of 9,204 participants in the TWENTE, DUTCH PEERS, BIO-RESORT, and BIONYX (TWENTE I-IV) randomized trials. The main clinical end point was target vessel failure (TVF), a composite of cardiac death, target vessel-related myocardial infarction (MI), or clinically indicated target vessel revascularization. RESULTS: The 671 octogenarian trial participants had significantly more comorbidities. TVF was higher in octogenarians than in 8,533 patients <80 years (7.3% vs 5.3%, hazard ratio [HR]: 1.36, 95% CI: 1.0-1.83, P = .04). The cardiac death rate was higher in octogenarians (3.9% vs 0.8%, P < .001). There was no significant between-group difference in target vessel MI (2.3% vs 2.3%, P = .88) and repeat target vessel revascularization (1.9% vs 2.8%, P = .16). In multivariate analyses, age ≥ 80 years showed no independent association with TVF (adjusted HR: 1.04, 95% CI: 0.76-1.42), whereas the risk of cardiac death remained higher in octogenarians (adjusted HR: 3.38, 95% CI: 2.07-5.52, P < .001). In 6,002 trial participants, in whom data on major bleeding were recorded, octogenarians (n = 459) showed a higher major bleeding risk (5.9% vs 1.9%; HR: 3.08, 95% CI: 2.01-4.74, P < .001). CONCLUSIONS: Octogenarian participants in 4 large-scale randomized DES trials had more comorbidities and a higher incidence of the main end point TVF. Cardiac mortality was higher in octogenarians, whereas there was no increase in MI or target vessel revascularization rates. Treatment of octogenarian patients with new-generation DES appears to be safe and effective.


Assuntos
Stents Farmacológicos/classificação , Everolimo/farmacologia , Infarto do Miocárdio , Complicações Pós-Operatórias , Sirolimo/análogos & derivados , Sirolimo/farmacologia , Idoso de 80 Anos ou mais , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/cirurgia , Feminino , Humanos , Imunossupressores/farmacologia , Masculino , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/mortalidade , Intervenção Coronária Percutânea , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/mortalidade , Reoperação/métodos , Reoperação/estatística & dados numéricos , Risco Ajustado/métodos , Fatores de Risco , Resultado do Tratamento
10.
JACC Cardiovasc Interv ; 13(9): 1100-1109, 2020 05 11.
Artigo em Inglês | MEDLINE | ID: mdl-32381186

RESUMO

OBJECTIVES: The aim of this study was to assess 2-year safety and efficacy of the current-generation thin composite-wire-strut durable-polymer Resolute Onyx zotarolimus-eluting stent (ZES), compared with the ultrathin-strut biodegradable-polymer Orsiro sirolimus-eluting stent (SES) in all-comers and a pre-specified small-vessel subgroup analysis. BACKGROUND: The Resolute Onyx ZES is widely used in clinical practice, but no follow-up data beyond 1 year have been published. The randomized BIONYX (Bioresorbable Polymer-Coated Orsiro Versus Durable Polymer-Coated Resolute Onyx Stents) trial (NCT02508714) established the noninferiority of ZES versus SES regarding target vessel failure (TVF) rates. METHODS: A total of 2,488 all-comer patients were treated at 7 coronary intervention centers in Belgium, Israel, and the Netherlands. The main endpoint, TVF, was a composite of safety (cardiac death or target vessel-related myocardial infarction) and efficacy (clinically indicated target vessel revascularization). Two-year follow-up data were analyzed using Kaplan-Meier methods. RESULTS: Two-year follow-up data were available for 2,460 of 2,488 patients (98.9%). TVF occurred in 93 of 1,243 patients (7.6%) assigned to ZES versus 87 of 1,245 patients (7.1%) assigned to SES (log-rank p = 0.66). There was no significant between-stent difference in individual components of this endpoint. The incidence of definite-or-probable stent thrombosis was low for both treatment arms (0.4% vs. 1.1%; log-rank p = 0.057). In patients stented in small vessels, there was no between-stent difference (TVF 8.2% vs. 8.7% [log-rank p = 0.75], target lesion revascularization 4.0% vs. 4.4% [log-rank p = 0.77]). CONCLUSIONS: At 2-year follow-up, the novel thin composite-wire-strut durable-polymer Resolute Onyx ZES showed in all-comers similar safety and efficacy compared with the ultrathin cobalt-chromium-strut biodegradable-polymer Orsiro SES. The analysis of patients who were treated in small vessels also suggested no advantage for either stent.


Assuntos
Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Sirolimo/análogos & derivados , Idoso , Bélgica , Fármacos Cardiovasculares/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Trombose Coronária/etiologia , Feminino , Humanos , Israel , Masculino , Pessoa de Meia-Idade , Países Baixos , Intervenção Coronária Percutânea/efeitos adversos , Estudos Prospectivos , Desenho de Prótese , Sirolimo/administração & dosagem , Sirolimo/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
11.
Catheter Cardiovasc Interv ; 96(2): E110-E118, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-31625262

RESUMO

BACKGROUND: Patients with coronary disease may have unknown diabetes or prediabetes. We evaluated 3-year outcomes after percutaneous coronary intervention (PCI) with contemporary drug-eluting stents (DES) in patients with silent diabetes, prediabetes, and normoglycemia. METHODS: All BIO-RESORT trial (NCT01674803) participants without known diabetes, enrolled at our center, were invited for oral glucose tolerance testing (OGTT) and measurements of fasting plasma glucose and glycated hemoglobin (HbA1c). RESULTS: OGTT detected silent diabetes in 68 (6.9%), prediabetes in 132 (13.4%), and normoglycemia in 788 (79.8%) of all 988 study participants. Follow-up was available in 986 (99.8%) patients. The main endpoint target vessel failure (TVF: cardiac death, target vessel-related myocardial infarction [MI], or target vessel revascularization) differed between groups (14.8, 9.9, and 5.6%; p = .002), driven by MI during the first 48 hr and by cardiac death (p < .001; p = .026). Between 48 hr and 3-years, there was no significant between-group difference in TVF, target vessel MI, and target vessel revascularization. Multivariable analysis demonstrated that silent diabetes was independently associated with TVF (adjusted HR: 2.52, 95%-CI: 1.26-5.03). An alternative diagnostic approach-HbA1c and fasting plasma glucose-detected silent diabetes and prediabetes in 33 (3.3%) and 217 (22.0%) patients, and normoglycemia in 738 (74.7%); TVF rates were 12.1, 7.9, and 6.0% (p = .23). CONCLUSION: In patients without known diabetes, abnormal glucose metabolism by OGTT was independently associated with higher 3-year TVF rates after PCI with contemporary DES. This difference was driven by periprocedural MI and cardiac death. After the first 48 hr, the rates of TVF, target vessel MI, and target vessel revascularization were low and did not differ significantly between metabolic groups.


Assuntos
Glicemia/metabolismo , Doença da Artéria Coronariana/terapia , Diabetes Mellitus/diagnóstico , Stents Farmacológicos , Teste de Tolerância a Glucose , Intervenção Coronária Percutânea/instrumentação , Estado Pré-Diabético/diagnóstico , Idoso , Doenças Assintomáticas , Biomarcadores/sangue , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Diabetes Mellitus/sangue , Diabetes Mellitus/mortalidade , Feminino , Hemoglobinas Glicadas/metabolismo , Humanos , Masculino , Pessoa de Meia-Idade , Países Baixos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Estado Pré-Diabético/sangue , Estado Pré-Diabético/mortalidade , Valor Preditivo dos Testes , Estudos Prospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
12.
Nanotechnology ; 31(9): 095701, 2020 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-31703211

RESUMO

Zinc oxide (ZnO) hollow spheres with defined morphology and micro-/nanostructure are prepared by a hydrothermal synthesis approach. The materials possess fine-leaved structures at their particle surface (nanowall hollow micro spheres). Morphology control is achieved by citric acid used as an additive in variable relative quantities during the synthesis. The structure formation is studied by various time-dependent ex situ methods, such as scanning electron microscopy, x-ray diffraction, and Raman spectroscopy. The fine-leaved surface structure is characterized by high-resolution transmission electron microscopy techniques (HRTEM, STEM), using a high-angle annular dark field detector, as well as by differential phase contrast analysis. In-depth structural characterization of the nanowalls by drop-by-drop ex situ FE-SEM analysis provides insight into possible structure formation mechanisms. Further investigation addresses the thermal stability of the particle morphology and the enhancement of the surface-to-volume ratio by heat treatment (examined by N2 physisorption).

13.
JACC Cardiovasc Interv ; 12(17): 1650-1660, 2019 09 09.
Artigo em Inglês | MEDLINE | ID: mdl-31422087

RESUMO

OBJECTIVES: The aim of this study was to assess the 3-year safety and efficacy of treating all-comer patients with 3 contemporary drug-eluting stents (DES). BACKGROUND: The BIO-RESORT (Comparison of Biodegradable Polymer and Durable Polymer Drug-Eluting Stents in an All Comers Population) (TWENTE III) randomized trial (NCT01674803) found similar 1-year safety and efficacy for the 2 biodegradable-polymer DES (i.e., ultrathin-strut cobalt-chromium Orsiro sirolimus-eluting stent [SES] and very-thin-strut platinum-chromium Synergy everolimus-eluting stent) compared with the durable-polymer thin-strut cobalt-chromium Resolute Integrity zotarolimus-eluting stent (ZES). Two-year follow-up suggested that the SES might reduce repeat revascularizations beyond 1 year compared with the ZES. METHODS: A total of 3,514 all-comer patients were treated at 4 centers for coronary intervention. The main clinical endpoint, target vessel failure, was a composite of safety (cardiac death or target vessel-related myocardial infarction) and efficacy (target vessel revascularization). Secondary endpoints included the individual components of target vessel failure and stent thrombosis. RESULTS: Three-year follow-up data were available for 3,393 of 3,514 patients (96.6%). Target vessel failure occurred in 8.5% with SES and 10.0% with ZES (plog rank = 0.22) and in 8.8% with everolimus-eluting stents (vs. ZES, plog rank = 0.32). Rates of cardiac death, target vessel myocardial infarction, and target vessel revascularization were similar between stent groups. Landmark analyses found no statistically significant between-stent difference in repeat revascularization between 1 and 3 years. Definite or probable stent thrombosis rates were low (SES, 1.1%; everolimus-eluting stent, 1.1%; ZES, 0.9%) and similar with all 3 DES. CONCLUSIONS: Despite substantial differences in stent backbone and polymer coating, all 3 DES showed favorable 3-year safety and efficacy in all comers, without significant between-stent differences. Further follow-up is required to definitely answer the question of whether one stent might improve clinical outcomes at a later stage.


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Everolimo/administração & dosagem , Intervenção Coronária Percutânea/instrumentação , Polímeros/química , Sirolimo/análogos & derivados , Idoso , Fármacos Cardiovasculares/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Trombose Coronária/etiologia , Everolimo/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Países Baixos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Desenho de Prótese , Fatores de Risco , Sirolimo/administração & dosagem , Sirolimo/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
14.
Lancet ; 392(10154): 1235-1245, 2018 10 06.
Artigo em Inglês | MEDLINE | ID: mdl-30253879

RESUMO

BACKGROUND: During the past decade, many patients had zotarolimus-eluting stents implanted, which had circular shape cobalt-chromium struts with limited radiographic visibility. The Resolute Onyx stent was developed to improve visibility while reducing strut thickness, which was achieved by using a novel composite wire with a dense platinum-iridium core and an outer cobalt-chromium layer. We did the first randomised clinical trial to assess the safety and efficacy of this often-used stent compared with the Orsiro stent, which consists of ultrathin cobalt-chromium struts. METHODS: We did an investigator-initiated, assessor-blinded and patient-blinded, randomised non-inferiority trial in an allcomers population at seven independently monitored centres in Belgium, Israel, and the Netherlands. Eligible participants were aged 18 years or older and required percutaneous coronary intervention with drug-eluting stents. After guide wire passage with or without predilation, members of the catheterisation laboratory team used web-based computer-generated allocation sequences to randomly assign patients (1:1) to either the Resolute Onyx or the Orsiro stent. Randomisation was stratified by sex and diabetes status. Patients and assessors were masked to allocated stents, but treating clinicians were not. The primary endpoint was target vessel failure at 1 year, a composite of cardiac death, target-vessel-related myocardial infarction, and target vessel revascularisation, and was assessed by intention to treat (non-inferiority margin 2·5%) on the basis of outcomes adjudicated by an independent event committee. This trial is registered with ClinicalTrials.gov, number NCT02508714. FINDINGS: Between Oct 7, 2015, and Dec 23, 2016, 2516 patients were enrolled, 2488 of whom were included in the intention-to-treat analysis (28 withdrawals or screening failures). 1243 participants were assigned to the Resolute Onyx group, and 1245 to the Orsiro group. Overall, 1765 (70·9%) participants presented with acute coronary syndromes and 1275 (51·2%) had myocardial infarctions. 1-year follow-up was available for 2478 (99·6%) patients. The primary endpoint was met by 55 (4·5%) patients in the Resolute Onyx group and 58 (4·7%) in the Orsiro group. Non-inferiority of Resolute Onyx to Orsiro was thus established (absolute risk difference -0·2% [95% CI -1·9 to 1·4]; upper limit of the one-sided 95% CI 1·1%; pnon-inferiority=0·0005). Definite or probable stent thrombosis occurred in one (0·1%) participant in the Resolute Onyx group and nine (0·7%) in the Orsiro group (hazard ratio 0·11 [95% CI 0·01-0·87]; p=0·0112). INTERPRETATION: The Resolute Onyx stent was non-inferior to Orsiro for a combined safety and efficacy endpoint at 1-year follow-up in allcomers. The low event rate in both groups suggests that both stents are safe, and the very low rate of stent thrombosis in the Resolute Onyx group warrants further clinical investigation. FUNDING: Biotronik and Medtronic.


Assuntos
Doença da Artéria Coronariana/cirurgia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Desenho de Prótese , Implantes Absorvíveis , Adulto , Idoso , Idoso de 80 Anos ou mais , Ligas de Cromo , Stents Farmacológicos/efeitos adversos , Estudos de Equivalência como Asunto , Feminino , Seguimentos , Humanos , Análise de Intenção de Tratamento , Masculino , Pessoa de Meia-Idade , Polímeros , Estudos Prospectivos , Método Simples-Cego , Resultado do Tratamento
15.
Cardiovasc Drugs Ther ; 32(6): 567-576, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30143879

RESUMO

PURPOSE: Patients with high bleeding risk (HBR) who undergo percutaneous coronary intervention also have an increased risk of ischemic events and represent an overall high-risk population. The coating of durable polymer drug-eluting stents (DP-DES) may induce inflammation and delay arterial healing, which might be reduced by novel biodegradable polymer DES (BP-DES). We aimed to evaluate the safety and efficacy of treating HBR patients with very thin-strut BP-DES versus thin-strut DP-DES. METHODS: Participants in BIO-RESORT (NCT01674803), an investigator-initiated multicenter, randomized all-comers trial, were treated with very thin-strut BP-DES (Synergy or Orsiro) or thin-strut DP-DES (Resolute Integrity). For the present analysis, patients were classified following HBR criteria based on previous trials. The primary endpoint was target vessel failure: a composite of cardiac death, target vessel-related myocardial infarction, or target vessel revascularization at 1 year. RESULTS: Of all 3514 patients, 1009 (28.7%) had HBR. HBR patients were older (p < 0.001) and had more co-morbidities than non-HBR patients (p < 0.001). At 1-year follow-up, HBR patients had significantly higher rates of target vessel failure (6.7 vs. 4.2%, p = 0.003), cardiac death (1.9 vs. 0.4%, p < 0.001), and major bleeding (3.3 vs. 1.5%, p = 0.001). Of all 1009 HBR patients, 673 (66.7%) received BP-DES and 336 (33.3%) had DP-DES. The primary endpoint was met by 43/673 (6.5%) patients treated with BP-DES and 24/336 (7.3%) treated with DP-DES (HR 0.88 [95%CI 0.54-1.46], p = 0.63). There were no significant between-group differences in the most global patient-oriented clinical endpoint (9.7 vs. 10.5%, HR 0.92 [95%CI 0.61-1.39], p = 0.69) and other secondary endpoints. CONCLUSIONS: At 1-year follow-up, very thin-strut BP-DES showed similar safety and efficacy for treating HBR patients as thin-strut DP-DES.


Assuntos
Implantes Absorvíveis , Doença da Artéria Coronariana/cirurgia , Stents Farmacológicos , Hemorragia/induzido quimicamente , Intervenção Coronária Percutânea/instrumentação , Inibidores da Agregação Plaquetária/efeitos adversos , Polímeros/química , Idoso , Idoso de 80 Anos ou mais , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Feminino , Hemorragia/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Países Baixos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Desenho de Prótese , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
16.
EuroIntervention ; 14(8): 915-923, 2018 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-29790480

RESUMO

AIMS: The aim of the study was to evaluate the two-year clinical outcome of all-comer trial participants who were treated with two very different thin-strut biodegradable polymer versus thin-strut durable polymer drug-eluting stents (DES). Prolonged clinical outcome after discontinuation of dual antiplatelet therapy is of particular interest, given the highly dissimilar polymer types, amount, distribution, and degradation speed of both biodegradable polymer DES. METHODS AND RESULTS: The BIO-RESORT trial (NCT01674803) randomly assigned 3,514 patients to treatment with biodegradable polymer SYNERGY everolimus-eluting stents (EES) or Orsiro sirolimus-eluting stents (SES), or durable polymer Resolute Integrity zotarolimus-eluting stents (ZES). At two-year follow-up (available in 98.8%), the rate of the primary composite endpoint target vessel failure (TVF) was 8.3% in ZES versus 6.8% in EES (p=0.19) and 6.6% in SES (p=0.12). Landmark analyses at one year revealed differences between SES and ZES in the rates of target lesion revascularisation and target lesion failure (0.6% vs. 1.5%, p=0.04, and 1.1% vs. 2.4%, p=0.02, respectively) as well as other composite secondary endpoints that reached statistical significance. CONCLUSIONS: At two-year follow-up, there was no significant between-DES difference in the rates of the primary endpoint. Landmark analyses provided a signal that the use of SES versus ZES might reduce the risk of repeat revascularisation after one-year follow-up.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Doença da Artéria Coronariana/cirurgia , Everolimo , Humanos , Polímeros , Resultado do Tratamento
17.
Int J Cardiol ; 268: 11-17, 2018 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-29801763

RESUMO

BACKGROUND: The prospective observational CHANGE DAPT study compared clopidogrel versus ticagrelor-based dual antiplatelet (DAPT) regimens in consecutive patients with acute coronary syndrome (ACS), treated with percutaneous coronary intervention (PCI) with contemporary drug-eluting stents (DES). During the ticagrelor period (TP, May 2014-August 2015) there were more major bleedings than during the clopidogrel period (CP, December 2012-April 2014). METHODS AND RESULTS: To evaluate whether the excess of major bleedings during TP may be limited to high bleeding risk (HBR) patients, we performed an explorative analysis of all 2062 CHANGE DAPT participants, of whom 547(26.5%) were classified as HBR (CP, n = 245; TP, n = 302). In HBR and non-HBR patients, we assessed the impact of CP versus TP on propensity score-adjusted rates of major bleeding and a pre-defined ischemic endpoint (composite of cardiac death, myocardial infarction, or stroke) at 1-year follow-up. Among HBR patients, the rate of major bleeding was significantly higher during TP (1.7% vs. 5.0%; HRadjusted 3.70 [95% CI 1.18-11.67], p = 0.03), while there was no significant difference in the ischemic endpoint (6.6% vs. 8.0%, HRadjusted 1.23 [95% CI 0.63-2.42], p = 0.54). In non-HBR patients, the rates of major bleeding (1.1% vs. 1.7%; HRadjusted 2.13 [95% CI 0.84-5.43], p = 0.11) and the ischemic endpoint (2.8% vs. 3.4%, HRadjusted 1.38 [95% CI 0.74-2.57], p = 0.32) were similar between both periods. CONCLUSIONS: Among consecutive ACS patients, the increased risk of major bleeding during ticagrelor-based DAPT was limited to HBR patients. In both HBR and non-HBR patients, ticagrelor-based DAPT did not reduce ischemic outcomes following treatment with contemporary DES implantation.


Assuntos
Síndrome Coronariana Aguda/terapia , Clopidogrel/efeitos adversos , Stents Farmacológicos/efeitos adversos , Hemorragia/induzido quimicamente , Inibidores da Agregação Plaquetária/efeitos adversos , Ticagrelor/efeitos adversos , Síndrome Coronariana Aguda/diagnóstico , Síndrome Coronariana Aguda/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Stents Farmacológicos/tendências , Feminino , Seguimentos , Hemorragia/diagnóstico , Hemorragia/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/tendências , Estudos Prospectivos
18.
JACC Cardiovasc Interv ; 11(5): 462-469, 2018 03 12.
Artigo em Inglês | MEDLINE | ID: mdl-29519378

RESUMO

OBJECTIVES: The study sought to evaluate for the first time the 5-year outcomes after treating an all-comers population with newer-generation cobalt chromium-based Resolute Integrity zotarolimus-eluting stents (ZES) (Medtronic, Santa Rosa, California) versus platinum chromium-based PROMUS Element everolimus eluting stents (EES) (Boston Scientific, Natick, Massachusetts). BACKGROUND: The DUTCH PEERS (TWENTE II) (DUrable polymer-based sTent CHallenge of Promus ElemEnt versus ReSolute integrity: TWENTE II) trial is a randomized, multicenter, single-blinded, investigator-initiated all-comers trial that found at its main analysis similar 1-year safety and efficacy for both drug-eluting stents. It is the first randomized trial ever to investigate the Resolute Integrity ZES and the first trial to compare both devices. METHODS: In total, 1,811 patients were 1:1 randomized to ZES versus EES. We performed a pre-specified assessment of the 5-year clinical outcomes in terms of safety and efficacy. The main endpoint target vessel failure (TVF) is a composite of cardiac death, target vessel-related myocardial infarction, or target vessel revascularization. Secondary endpoints included the individual components of TVF, and stent thrombosis. The study was independently monitored, and adverse clinical events were independently adjudicated. RESULTS: Five-year clinical follow-up data was available in 1,798 (99.3%) patients. The ZES and EES groups showed favorable outcomes, with similar 5-year incidence of TVF (13.2% vs. 14.2%; plog-rank = 0.62) and its individual components: cardiac death (4.5% vs. 4.9%; plog-rank = 0.69), target vessel-related myocardial infarction (3.1% vs. 2.6%; plog-rank = 0.47), and target vessel revascularization (7.6% vs. 8.6%; plog-rank = 0.46). The 5-year incidence of definite or probable stent thrombosis was similar (1.5% vs. 1.3%; plog-rank = 0.83). CONCLUSIONS: At 5-year follow-up, the Resolute Integrity ZES and PROMUS Element EES showed similar and sustained results in terms of safety and efficacy for treating a broad population of all-comers.


Assuntos
Síndrome Coronariana Aguda/cirurgia , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/cirurgia , Stents Farmacológicos , Everolimo/administração & dosagem , Infarto do Miocárdio/cirurgia , Intervenção Coronária Percutânea/instrumentação , Sirolimo/análogos & derivados , Síndrome Coronariana Aguda/diagnóstico por imagem , Síndrome Coronariana Aguda/mortalidade , Idoso , Fármacos Cardiovasculares/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Reestenose Coronária/etiologia , Trombose Coronária/etiologia , Everolimo/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/mortalidade , Países Baixos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Desenho de Prótese , Fatores de Risco , Método Simples-Cego , Sirolimo/administração & dosagem , Sirolimo/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
19.
JACC Cardiovasc Interv ; 11(5): 448-459, 2018 03 12.
Artigo em Inglês | MEDLINE | ID: mdl-29454724

RESUMO

OBJECTIVES: This study sought to assess the prevalence and clinical impact of silent diabetes and pre-diabetes in "nondiabetic" percutaneous coronary intervention (PCI) all-comers. BACKGROUND: Patients with undetected and thus untreated (silent) diabetes may have higher event risks after PCI with contemporary drug-eluting stents (DES). METHODS: The BIO-RESORT Silent Diabetes study, performed at Thoraxcentrum Twente, is a substudy of the randomized multicenter BIO-RESORT (BIOdegradable Polymer and DuRable Polymer Drug-eluting Stents in an All COmeRs PopulaTion) trial (NCT01674803). Patients underwent oral glucose tolerance testing (OGTT), and assessment of glycosylated hemoglobin with fasting plasma glucose. Primary endpoint was a composite of cardiac death, target vessel-related myocardial infarction, or target vessel revascularization at 1 year. RESULTS: Of the 988 participants, OGTT detected silent diabetes in 68 (6.9%), pre-diabetes in 133 (13.3%), and normal glucose metabolism in 788 (79.8%). Patients with silent diabetes had higher primary endpoint rates (13.2% vs. 7.6% vs. 4.8%; p < 0.001; silent diabetes vs. normal: hazard ratio: 4.2; 95% confidence interval: 1.9 to 9.2). Differences were driven by myocardial infarction (p < 0.001) which occurred mostly <48 h. Based on glycosylated hemoglobin and fasting plasma glucose, silent diabetes was found in 33 (3.3%) patients, pre-diabetes in 217 (22.0%) patients, and normal glucose metabolism in 738 (74.7%) patients; primary endpoint rates were similar to OGTT-based analyses (12.1% vs. 5.5% vs. 3.1%; p = 0.01). Multivariate analyses demonstrated that abnormal glucose metabolism by either diagnostic approach, present in 330 (33.4%) patients, independently predicted adverse event risk (hazard ratio: 2.2; 95% confidence interval: 1.2 to 4.2). CONCLUSIONS: Abnormal glucose metabolism was detected in 1 of 3 "nondiabetic" PCI patients and was independently associated with up to 4-fold higher event risks. Future intervention trials should determine whether meaningful benefits accrue from routine glycemia testing in such patients.


Assuntos
Doença da Artéria Coronariana/cirurgia , Diabetes Mellitus/epidemiologia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Idoso , Doenças Assintomáticas , Biomarcadores/sangue , Glicemia/metabolismo , Doença da Artéria Coronariana/sangue , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/mortalidade , Diabetes Mellitus/sangue , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/mortalidade , Feminino , Teste de Tolerância a Glucose , Hemoglobinas Glicadas/metabolismo , Humanos , Masculino , Pessoa de Meia-Idade , Países Baixos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Estado Pré-Diabético/sangue , Estado Pré-Diabético/diagnóstico , Estado Pré-Diabético/epidemiologia , Prevalência , Estudos Prospectivos , Desenho de Prótese , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
20.
J Am Heart Assoc ; 7(3)2018 01 30.
Artigo em Inglês | MEDLINE | ID: mdl-29382666

RESUMO

BACKGROUND: Percutaneous coronary intervention (PCI) in patients with previous coronary artery bypass grafting (CABG) is associated with adverse clinical events. Although newer generation drug-eluting stents showed favorable short-term safety profiles, there is a lack of long-term outcome data. We evaluated the impact of previous CABG on 5-year clinical outcomes of patients treated with PCI using newer-generation drug-eluting stents. METHODS AND RESULTS: In this patient-level pooled analysis of the prospective TWENTE (The Real-World Endeavor Resolute versus Xience V Drug-Eluting Stent Study in Twente) trial and nonenrolled TWENTE registry, we assessed a consecutive series of patients who underwent PCI with newer-generation drug-eluting stents for non-ST-segment-elevation acute coronary syndromes or stable angina. Of all 1709 patients, 202 (11.8%) had a history of CABG. Patients with previous CABG had significantly higher 5-year rates of cardiac death (10.4% versus 4.3%; P<0.001) and target vessel revascularization (25.0% versus 8.1%; P<0.001). These differences remained statistically significant after adjustment for differences in baseline characteristics. Landmark analysis revealed that from 1- to 5-year follow-up, the rates of cardiac death (8.1% versus 3.2%; P<0.001) and target vessel revascularization (17.1% versus 5.9%; P<0.001) were significantly higher in patients with previous CABG. Among patients with a history of CABG, PCI of an obstructed vein graft was associated with a higher rate of 5-year target vessel revascularization (P=0.003). CONCLUSIONS: At 5-year follow-up after PCI with newer-generation drug-eluting stents, the risk of cardiac death and target vessel revascularization was significantly higher in patients with previous CABG. The target vessel revascularization rate was highest in patients who underwent PCI of obstructed vein grafts.


Assuntos
Ponte de Artéria Coronária , Doença das Coronárias/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Idoso , Ponte de Artéria Coronária/efeitos adversos , Ponte de Artéria Coronária/mortalidade , Doença das Coronárias/diagnóstico por imagem , Doença das Coronárias/mortalidade , Doença das Coronárias/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Desenho de Prótese , Ensaios Clínicos Controlados Aleatórios como Assunto , Sistema de Registros , Retratamento , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...