Invest Radiol ; 44(11): 697-704, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19809344

RESUMO

PURPOSE: To determine the feasibility of detecting thrombi using a fibrin-specific gadolinium-based magnetic resonance imaging contrast agent, EP-2104R. METHODS: Subjects with confirmed thrombus in the venous system (n = 14), or in the heart, or arterial system (n = 38) were enrolled. Patients were imaged before and at various times following a 4 mumol/kg intravenous bolus injection of EP-2104R: <1 hour (N = 16), 2 to 6 hours (N = 36), and/or 20 to 36 hours (N = 33). Images were assessed by investigators at each site and by a single reader not affiliated with the sites to determine whether thrombi were visible, not visible, or further enhanced with EP-2104R. A subset of data was analyzed quantitatively by measuring a signal intensity relative to background tissue. RESULTS: Overall, 29 thrombi were visible before contrast administration, 3 of 14 in the venous system, and 26 of 38 in the arteries and heart. Thrombi generally enhanced in signal after EP-2104R injection, and an additional 7 were visualized. After contrast, 4 of 14 thrombi were visible in the venous system, and 32 of 38 in the arteries and heart. Thrombi were more conspicuous when imaged at 2 to 6 hours post EP-2104R compared with within 1 hour, because of lower blood background. Quantitatively, the post: pre signal intensity ratio was 1.90 at 2 to 6 hours post injection (standard deviation = 1.08, N = 20, P < 0.001); and 2.04 (standard deviation = 1.29, N = 19, P < 0.0025) for the 20 to 36 hours time point. There were no serious adverse events considered related to study drug. CONCLUSION: EP-2104R enhanced magnetic resonance imaging detects thrombi not readily visible in precontrast screening and gives additional enhancement of thrombi that are visible in precontrast imaging.


Assuntos
Fibrina/metabolismo , Gadolínio/farmacocinética , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Peptídeos/farmacocinética , Trombose/diagnóstico , Trombose/metabolismo , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste/farmacocinética , Sistemas de Liberação de Medicamentos/métodos , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...