Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anaesthesist ; 56(8): 765-71, 2007 Aug.
Artigo em Alemão | MEDLINE | ID: mdl-17516038

RESUMO

BACKGROUND: Demographic changes and aggressive medication with platelet aggregation inhibitors have resulted in a marked increase in blood and coagulation product expenditure and costs in cardiac surgery. We analyzed the bedside coagulation test (ROTEM) in order to verify clot forming quality and to find a cost-effective treatment algorithm. PATIENTS AND METHODS: Annual treatment costs of all cardiosurgical patients were retrospectively analyzed before (729 patients) and after (693 patients) implementation of the bedside ROTEM test. Cumulative numbers and costs of platelet concentrates (PltC), fresh frozen plasma (FFP), red blood cell units (RBC), and the coagulation factors prothrombin complex concentrates (PCC), recombinant factor VIIa (rFVIIa), factor XIII (FXIII), and fibrinogen were assessed. Average monthly numbers and costs were compared. The number of rethoracotomies and early mortality were assessed and compared in both periods. RESULTS: After ROTEM implementation cumulative RBC expenditure showed a 25% decrease and PltC a 50% decrease. FFP expenditure remained unchanged. PCC, FXIII were markedly reduced (-80%) while rFVIIa was entirely omitted. Fibrinogen, however, showed a two-fold increase. Cumulative average monthly costs of all blood products decreased from 66,000 EUR to 45,000 EUR (-32%). Coagulation factor average monthly costs decreased from 60,000 EUR to 30,000 EUR (-50%) yielding combined savings of 44%. In contrast, average monthly costs for ROTEM were 1,580 EUR. The total number of rethoracotomies decreased from 6.6% to 5.5% while early mortality (5.9%; 6.0%) remained stable. CONCLUSIONS: Cumulative costs for treatment of perioperative coagulation disorders were reduced by bedside ROTEM analysis to achieve a selective substitution management. Saved costs for blood and coagulation products clearly outweighed the expenses of ROTEM. Adequate differential coagulation management can therefore be cost-effective.


Assuntos
Procedimentos Cirúrgicos Cardíacos/instrumentação , Sistemas Automatizados de Assistência Junto ao Leito , Tromboelastografia , Testes de Coagulação Sanguínea , Transfusão de Sangue/economia , Transfusão de Sangue/estatística & dados numéricos , Procedimentos Cirúrgicos Cardíacos/economia , Humanos , Sistemas Automatizados de Assistência Junto ao Leito/economia , Estudos Retrospectivos , Tromboelastografia/economia
3.
Thorac Cardiovasc Surg ; 54(2): 85-90, 2006 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16541347

RESUMO

BACKGROUND: In an increasingly senescent population stented biological valves have regained renewed popularity because of the absence of anticoagulation, while the stented design allows for safe and easier implantation. Constructed bovine pericardial valves as well as valves with porcine cusps are used, both of which exhibit good clinical results although degeneration still appears. While clinical hemodynamic studies did not show particular differences between both valves types, the opening and closure behavior of native cusps and artificially constructed pericardial leaflets is different. It is unclear whether these phenomena account for differences in load and stress which may influence onset and course of degeneration. MATERIAL AND METHODS: Edwards Perimount (EP) and Medtronic Mosaic (MM) heart valves with diameters of 21 mm, 23 mm, and 25 mm were investigated in a pulse duplicator. Movements of the valves were visualized with a high-speed camera (1000 frames/sec). Mean transvalvular gradient (mm Hg), dissipated power (mW), and power transfer by stretching (mW), mean orifice area (mm2), opening time (ms), and closure time (ms) were analyzed in a range of cardiac outputs from 1.4 l/min to 6.3 l/min and 70 beats per minute. RESULTS: Closure times were generally longer than opening times for both valve types. Opening time of EP valves was longer than opening time of the MM valves of the same size (EP23: 31.2 +/- 2.5 ms; MM23: 12.7 +/- 0.1 ms). With respect to closure times, however, there were no marked differences between all valves (EP23: 69.3 +/- 2.0 ms; MM23: 63.2 +/- 6.3 ms). Smaller sized Perimount valves exhibited lower mean transvalvular gradients than Mosaic valves of the same size (EP23: 7.21 +/- 0.07 mm Hg; MM23: 10.5 +/- 0.15 mm Hg). In larger sizes these differences diminished. Power transfer to the valve's structures was significantly enhanced in EP valves (EP23: 134 +/- 1.3 mW; MM23: 64 +/- 0.9 mW). CONCLUSIONS: While valves with constructed pericardium showed lower mean transvalvular gradients, particularly in the smaller sizes, this valve type exhibited alterations of movement performance in contrast to porcine valves. It can be speculated that constant power transfer to the valve's structures may result in an earlier degeneration because of the impact of the increased load and stress on the suspension apparatus of the constructed pericardial leaflets.


Assuntos
Bioprótese/normas , Próteses Valvulares Cardíacas/normas , Stents , Animais , Fenômenos Biomecânicos , Velocidade do Fluxo Sanguíneo , Humanos , Técnicas In Vitro , Desenho de Prótese
4.
Thorac Cardiovasc Surg ; 54(1): 39-41, 2006 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-16485187

RESUMO

OBJECTIVE: Standard extracorporeal circulation (ECC) remains the staple procedure for cardiac surgeons. Despite modern membrane oxygenators and arterial filters micro bubbles are regularly detected in the arterial line. We investigated whether initial deairing of the venous drainage during connection can reduce the quantity and size of micro bubbles on the arterial side. METHODS: 12 patients underwent isolated coronary artery revascularization with conventional ECC using a two-stage venous catheter and an open, passive venous return into a reservoir. In 6 patients (Control) the venous catheter was routinely connected to the venous line, thereby accepting moderate incorporation of air. In another 6 patients (deaired) the catheter was connected avoiding any visible air entrapment. A bubble counter was used to detect the number and size of any micro bubbles in the arterial line of the ECC. The total number of bubbles as well as the number of bubbles of different sizes was assessed directly after initiation of ECC and during the first 60 sec. RESULTS: All patients had an uneventful surgery with a normal postoperative course. In the Control group a considerable number of bubbles of all sizes occurred initially and after 60 sec. In contrast, very few bubbles were detected in the deaired group. CONCLUSION: Incorporated venous air inevitably reaches the arterial side of the ECC. As deairing of the venous line is a simple and effective manoeuvre to significantly reduce the amount of micro bubbles on the arterial side, we recommend and perform routine deairing in all our patients.


Assuntos
Doença da Artéria Coronariana/cirurgia , Drenagem , Embolia Aérea/prevenção & controle , Circulação Extracorpórea/instrumentação , Microbolhas/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/instrumentação , Ponte Cardiopulmonar/instrumentação , Estudos de Casos e Controles , Cateteres de Demora , Circulação Cerebrovascular , Doença da Artéria Coronariana/fisiopatologia , Embolia Aérea/etiologia , Embolia Aérea/fisiopatologia , Desenho de Equipamento , Segurança de Equipamentos , Circulação Extracorpórea/efeitos adversos , Filtração/instrumentação , Humanos , Oxigenadores de Membrana , Tamanho da Partícula , Circulação Pulmonar , Veias Pulmonares/cirurgia , Resultado do Tratamento
5.
Thorac Cardiovasc Surg ; 53(5): 274-80, 2005 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16208612

RESUMO

BACKGROUND: Aortic annulus calcification can promote tilted implantation of mechanical valves. This study evaluates the hemodynamics of tilting disc valves under this condition. METHODS: 23 mm and 25 mm Ultracor (UC) and Medtronic-Hall-Easy-Fit (MH) valves were investigated in a pulse-duplicator under physiological conditions. Mean pressure gradient (dP(mean)), systolic energy loss (dW(sys)), effective orifice area (EOA), closure (V(Cl)), leakage (V(L)), and total regurgitation volume (V(R)) were assessed. Valves were independently positioned at five axial rotations (0 - 180 degrees , zero defined as major orifice facing the top of the "tilt-ramp") and three tilt angles (0 degrees, 10 degrees, 20 degrees) by lifting the prosthesis in the noncoronary sinus. RESULTS: Diameter-enhanced MH valves exhibited a better systolic performance but a higher regurgitation than corresponding UC valves. Moderate tilting showed a rotation-independent increase in dP(mean) and dW(sys) and a decrease in V (R) and EOA with no fundamental differences between valve types. Further tilting caused small additional changes at 90 - 180 degrees rotation. At 0 degrees rotation, however, dramatic regurgitation occurred throughout. CONCLUSION: Tilting worsened systolic performance regardless of valve type. It should therefore be avoided. Due to extensive regurgitation at 0 degrees rotation, this position should be corrected whenever tilting is inevitable.


Assuntos
Insuficiência da Valva Aórtica/fisiopatologia , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas/normas , Hemodinâmica/fisiologia , Postura/fisiologia , Pressão Sanguínea/fisiologia , Diástole/fisiologia , Frequência Cardíaca/fisiologia , Próteses Valvulares Cardíacas/classificação , Humanos , Modelos Cardiovasculares , Desenho de Prótese/classificação , Rotação , Volume Sistólico/fisiologia , Sístole/fisiologia , Teste da Mesa Inclinada
6.
Eur J Cardiothorac Surg ; 14(5): 494-502, 1998 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-9860206

RESUMO

OBJECTIVE: Pulmonary hypertension (PHT) is a life-threatening complication after isolated heart and lung transplantation. Recent work has shown that inhaled nitric oxide (NO) in combination with inhaled prostaglandin E1 (PGE1) reduce pulmonary hypertension but their influence on cardiac contractility is less well defined. METHODS: This study investigated left ventricular contractility as measured by the 'Preload Recruitable Stroke Work-Relation' (PRSW) in 24 anesthetized open chest pigs, 12 receiving in random order NO (50 ppm), PGE1 (20 microg/ml) and their combination compared to 12 controls. PHT was induced by embolization with glass beads (500 microm). Prior to induction of PHT, sonomicrometric crystals were placed on the heart to measure instantaneous cardiac dimensions. Instantaneous intraventricular pressure (micro-tip catheter) and intraventricular dimensions were recorded digitally, while intraventricular volumes were calculated from the intraventricular dimensions applying the cylindric ellipsoidal volume model for the left ventricle. PRSW was calculated from the instantaneous pressure and volume data during rapid vena caval occlusion by analysis of generated pressure-volume loops. All data were analyzed by MANOVA and corrected for heart rate (level of significance #: P < 0.05); PRSW-slope measures contractility, (PRSW-X-intercept did not change significantly). RESULTS: PRSW-change +/- SEM (in percent of initial PRSW after induction of PHT) was -14.6% +/- 4.4% versus 1.6% +/- 4.4% for NO versus Control (P = 0.004), -8.8% +/- 4.6% versus 1% +/- 3.3% (P = 0.18) for PGE1 versus Control and -5.7% +/- 4.4% versus 2.5% +/- 4.2% for NO + PGE1 versus Control (P = 0.33), respectively. In summary, application of NO 50 ppm significantly reduced left ventricular contractility while PGE1 20 microg/ml and the combination of NO and PGE1 did not. CONCLUSION: If NO is not available, the sole application of nebulized PGE1 (20 microg/ml) appears to be safe with respect to left ventricular contractility in the setting of PHT. The combination of NO and PGE1 for the treatment of pulmonary hypertension should be considered for clinical application in situations where a combination of pulmonary hypertension and decreased left ventricular function is present.


Assuntos
Alprostadil/administração & dosagem , Hipertensão Pulmonar/tratamento farmacológico , Contração Miocárdica/efeitos dos fármacos , Óxido Nítrico/administração & dosagem , Função Ventricular Esquerda/efeitos dos fármacos , Administração por Inalação , Alprostadil/uso terapêutico , Animais , Quimioterapia Combinada , Hipertensão Pulmonar/fisiopatologia , Óxido Nítrico/uso terapêutico , Distribuição Aleatória , Volume Sistólico/efeitos dos fármacos , Suínos
7.
Appl Opt ; 36(13): 2923-8, 1997 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-18253293

RESUMO

This structured light projection technique has been developed for the inspection of holes and tubes. In contrast to others, the triangulation base is parallel to the line of sight. The features of systems using this measurement method are the following: high accuracy in the wide-angle region, minimal diameter, symmetry of the measurements to the line of sight, and simplified coordinate calculation. The prototype application is the optics of the sewer pipe inspection robot KARO. Application fields are medical or technical wide-angle inspection systems (e.g., endoscopes).

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...