Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Toxicol Sci ; 49(6): 269-279, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38825486

RESUMO

Although morphine has been used for treatment-resistant dyspnea in end-stage heart failure patients, information on its cardiovascular safety profile remains limited. Morphine was intravenously administered to halothane-anesthetized dogs (n=4) in doses of 0.1, 1 and 10 mg/kg/10 min with 20 min of observation period. The low and middle doses attained therapeutic (0.13 µg/mL) and supratherapeutic (0.97 µg/mL) plasma concentrations, respectively. The low dose hardly altered any of the cardiovascular variables except that the QT interval was prolonged for 10-15 min after its start of infusion. The middle dose reduced the preload and afterload to the left ventricle for 5-15 min, then decreased the left ventricular contractility and mean blood pressure for 10-30 min, and finally suppressed the heart rate for 15-30 min. Moreover, the middle dose gradually but progressively prolonged the atrioventricular conduction time, QT interval/QTcV, ventricular late repolarization period and ventricular effective refractory period without altering the intraventricular conduction time, ventricular early repolarization period or terminal repolarization period. A reverse-frequency-dependent delay of ventricular repolarization was confirmed. The high dose induced cardiohemodynamic collapse mainly due to vasodilation in the initial 2 animals by 1.9 and 3.3 min after its start of infusion, respectively, which needed circulatory support to treat. The high dose was not tested further in the remaining 2 animals. Thus, intravenously administered morphine exerts a rapidly appearing vasodilator action followed by slowly developing cardiosuppressive effects. Morphine can delay the ventricular repolarization possibly through IKr inhibition in vivo, but its potential to develop torsade de pointes will be small.


Assuntos
Anestésicos Inalatórios , Halotano , Frequência Cardíaca , Morfina , Animais , Cães , Morfina/administração & dosagem , Frequência Cardíaca/efeitos dos fármacos , Anestésicos Inalatórios/administração & dosagem , Anestésicos Inalatórios/farmacocinética , Masculino , Toxicocinética , Relação Dose-Resposta a Droga , Analgésicos Opioides/administração & dosagem , Analgésicos Opioides/farmacocinética , Pressão Sanguínea/efeitos dos fármacos , Eletrocardiografia/efeitos dos fármacos , Feminino , Infusões Intravenosas , Vasodilatação/efeitos dos fármacos , Fenômenos Eletrofisiológicos/efeitos dos fármacos
2.
Intern Med ; 2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-38171861

RESUMO

A 51-year-old man presented with sudden-onset palpitations and dyspnea that had started 8 h earlier. The patient was restless and tachypneic and had persistent vomiting upon arrival. His sensorium and oxygen saturation levels rapidly declined three hours after arrival, and he was placed on a ventilator. On hospitalization day 2, he was removed from the ventilator and claimed that he had consumed a large amount of energy drinks (oral caffeine intake, approximately 1 g). The theophylline level on arrival had been elevated (9.0 µg/mL). Caffeine intoxication should be considered in patients presenting with restlessness, tachypnea, frequent vomiting, lactic acidosis, and electrolyte abnormalities.

3.
Chem Commun (Camb) ; 59(10): 1301-1304, 2023 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-36633220

RESUMO

A structurally constrained, double-helical S,C-bridged tetraphenyl-para-phenylenediamine (TPPD) has been synthesized. The stable radical cation of the S,C-bridged TPPD was generated by chemical oxidation, and the electron spin was found to be delocalized over the entire π-conjugated framework. The excellent conformational stability of the neutral molecule facilitated the separation of its enantiomers.

4.
Chemistry ; 28(59): e202203091, 2022 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-36229333

RESUMO

Invited for the cover of this issue are Masashi Hasegawa and co-workers at Kitasto University and Kyoto Prefectural University. The image depicts the reported multiply twisted chiral macrocycles as objects in a kaleidoscope. Read the full text of the article at 10.1002/chem.202202218.


Assuntos
Luminescência , Humanos
5.
Chemistry ; 28(59): e202202218, 2022 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-36066556

RESUMO

Chiral macrocyclic dimers, trimers, and tetramers composed of paraphenylene and tethered binaphthyl were synthesized, and their molecular structures and chiroptical properties were investigated. X-ray analysis and theoretical calculations revealed that multiple twisted molecular structures - dimers, trimers, and tetramers - adopt figure-of-eight, Möbius triangle, and concave rectangle structures, respectively. These homologues have large ϵ values in their UV-vis absorption spectra because of the π-conjugation of the naphthalene-phenylene-naphthalene frameworks. Owing to the shape-persistent ring structure and tethering with -OCH2 CH2 O-, high fluorescence quantum yields and a relatively high dissymmetry factor gCPL in circularly polarized luminescence (CPL) spectra were achieved. This results in CPL brightness (BCPL ) of over 100, which is greater than that of the conventional organic CPL dye.

6.
Eur J Mass Spectrom (Chichester) ; 27(1): 63-70, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33745337

RESUMO

Aminoglycosides are a class of broad-spectrum antibiotics with several clinical uses. Owing to the ototoxicity and nephrotoxicity of aminoglycosides, therapeutic drug monitoring is required. This study aimed to devise a high-throughput method for identification and quantitative determination of aminoglycoside antibiotics in human plasma samples using ultra-performance liquid chromatography-quadrupole time-of-flight-mass spectrometry (UPLC-Q-ToF-MS). Plasma samples (100 µL) spiked with five aminoglycosides (streptomycin, spectinomycin, amikacin, kanamycin, and gentamycin) and an internal standard (ribostamycin) were diluted and centrifuged in aqueous formic acid and acetonitrile. The clear supernatant extract was evaporated and reconstituted in the mobile phase, of which 4 µL was subjected to UPLC-Q-ToF-MS. Prominent peaks were observed for the drugs within 3 min. The recoveries of five aminoglycosides from plasma samples were 92.6-120%. The regression equations showed excellent linearity (0.9999 ≥ r2 ≥ 0.9987) within the range of 1.0-100 µg/mL, and detection limits of 0.5-2.0 µg/mL. The coefficients of the intra- and inter-day variations for five drugs were less than 11.8%, while the accuracy of quantitation was in the range of 89-111%. In this study, a novel method was presented for identification and determination of aminoglycosides in human plasma samples using UPLC-Q-ToF-MS analysis. This method can be applied to high-throughput analysis used for clinical and environmental purposes.


Assuntos
Preparações Farmacêuticas , Espectrometria de Massas em Tandem , Aminoglicosídeos , Antibacterianos , Cromatografia Líquida de Alta Pressão , Humanos
7.
Rapid Commun Mass Spectrom ; 33(24): 1906-1914, 2019 Dec 30.
Artigo em Inglês | MEDLINE | ID: mdl-31323696

RESUMO

RATIONALE: We developed a new high-throughput method to analyze tegafur (FT) and 5-fluorouracil (5-FU) in tear and plasma samples using hydrophilic interaction liquid chromatography (HILIC)/tandem mass spectrometry (MS/MS). METHODS: The tear samples (10 µL) spiked with FT, 5-FU, and 5-chlorouracil (internal standard) were diluted using 40 µL of 2 M ammonium acetate and 250 µL of acetonitrile with 2% formic acid; 20 µL of plasma spiked with the two drugs and internal standard was diluted with 80 µL of 2 M ammonium acetate and 500 µL of acetonitrile with 2% formic acid. After centrifugation, the clear supernatant extract (15 µL) was directly injected into the HILIC/MS/MS instrument, and each drug was separated on a Unison UK-Amino column (50 mm × 3 mm i.d., 3 µm particle size) with a linear gradient elution system composed of 10 mM ammonium acetate (pH 6.8) and acetonitrile at a flow rate of 0.7 mL/min. We performed quantification by multiple reaction monitoring (MRM) with negative-ion atmospheric-pressure chemical ionization. RESULTS: Distinct peaks were observed for the drugs on each MRM channel within 2 min. The regression equations showed good linearity within the range 0.04-4.0 µg/mL for the tear and plasma samples with detection limits at 0.02-0.04 µg/mL. Recoveries for target analytes (FT and 5-FU) for the tear and plasma samples were in the 94-128% and 94-104% ranges, respectively. The intra- and inter-day coefficients of variation for the two drugs were lower than 10.8%. The accuracies of quantitation were 97-115% for both samples. CONCLUSIONS: We established a high-throughput, reproducible, and practical procedure for analyzing FT and 5-FU in human tear and plasma samples using HILIC/MS/MS analysis with an aminopropyl-bonded mixed-mode separation column. This method can be applied to the high-throughput routines used in clinical analyses.


Assuntos
Fluoruracila/análise , Lágrimas/química , Tegafur/análise , Idoso , Cromatografia Líquida de Alta Pressão , Feminino , Fluoruracila/sangue , Humanos , Interações Hidrofóbicas e Hidrofílicas , Limite de Detecção , Masculino , Espectrometria de Massas em Tandem , Tegafur/sangue
8.
Leg Med (Tokyo) ; 31: 66-73, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29413992

RESUMO

A new high-throughput method was developed for analysis of valproate in human plasma samples by QuEChERS extraction and gas chromatography-tandem mass spectrometry (GC-MS/MS). Plasma samples (0.2 ml) spiked with valproate and secobarbital-d5 (internal standard) were diluted with 1.3 ml of distilled water. Acetonitrile (1 ml) was added followed by 0.4 g MgSO4 and 0.1 g NaOAC. After a centrifugation step (2000 g for 10 min), 1 ml of the supernatant was transferred to a dispersive-solid phase extraction (dSPE) tube containing 150 mg MgSO4 and 50 mg C18. This mixture was vortexed and centrifuged at 3000 g for 5 min, and then the upper layer was evaporated to dryness under a stream of nitrogen. The residue was dissolved in 40 µl ethyl acetate, and a 1-µl aliquot was injected into the GC-MS/MS. The GC separation of the compounds was achieved on a fused-silica capillary column Rxi-5Sil MS (30 m × 0.25 mm i.d.; 0.25-µm film thickness) and detected by MS/MS operating in electron ionization ion source mode. The regression equations showed excellent linearity (r > 0.9997) from 50 to 5000 ng/ml for plasma, with limit of detection of 10 ng/ml. The extraction efficiency of valproate for plasma ranged between 71.2%-103.5%. The coefficient of variation was <18.5%. The method was successfully applied to actual analyses of an autopsy case. This method can be useful for simple and reliable measurements of valproate in clinical and toxicological analyses; it can be integrated in screening and simultaneous determination methods for multiple drugs and poisons in the further studies.


Assuntos
Anticonvulsivantes/sangue , Cromatografia Gasosa-Espectrometria de Massas/métodos , Espectrometria de Massas em Tandem/métodos , Ácido Valproico/sangue , Adulto , Anticonvulsivantes/química , Feminino , Patologia Legal , Humanos , Secobarbital/sangue , Secobarbital/química , Ácido Valproico/química
9.
Leg Med (Tokyo) ; 24: 36-55, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28081789

RESUMO

A high-throughput method was developed for the detection of 31 benzodiazepine drugs and tandospirone in human plasma by on-line column-switching ultra-fast liquid chromatography-tandem mass spectrometry. Plasma samples (100µl) spiked with the 32 drugs and oxazepam-d5 (internal standard) were diluted with 300µl of 13.3mM ammonium acetate/acetonitrile (33:67, v/v). After centrifugation and filtration, the clear supernatant was injected directly onto the extraction column (Oasis HLB cartridge column). The following procedure was fully automated. The analytes retained on the extraction column were eluted by backflushing of the extraction column and introduced into an analytical column (SUMIPAX ODS D-Swifter column, 30mm×3.0mm i.d.; particle size 2µm) by column switching. Quantification was performed by multiple reaction monitoring with positive-ion electrospray ionization. Distinct peaks appeared for each drug and the internal standard on each channel within 7min, including the extraction time. All drugs spiked into plasma showed recoveries of 83-95%. The regression equations for the 32 drugs showed excellent linearities in the range of 50-2000pg/ml of plasma and the limits of detection ranged from 20 to 50pg/ml. The lower and upper limits of quantitation were 50-100ng/ml and 2000pg/ml, respectively. Intra- and interday coefficients of variation for none of the drugs were greater than 13.6%. The accuracies of quantitation were 87-112%. The multiple reaction monitoring information-dependent acquisition of enhanced product ions method enabled the quantification and confirmation of diazepam, triazolam, and lorazepam obtained from actual plasma.


Assuntos
Benzodiazepinas/sangue , Cromatografia Líquida de Alta Pressão , Isoindóis/sangue , Piperazinas/sangue , Pirimidinas/sangue , Espectrometria de Massas em Tandem/métodos , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
10.
J Pharm Biomed Anal ; 88: 71-80, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24036363

RESUMO

A simple and sensitive method was developed and validated here for the analysis of thirteen nonsteroidal anti-inflammatory drugs (NSAIDs) in human plasma samples by hydrophilic interaction liquid chromatography (HILIC)-tandem mass spectrometry (MS/MS). A small volume of plasma (20µL) spiked with compounds was diluted with 80µL of 10-mM ammonium acetate followed by a simple protein precipitation with 400µL of acetonitrile. After centrifugation, the clear supernatant extract was directly injected into the HILIC-MS/MS, without any solvent evaporation and reconstitution steps. The chromatographic separation of the NSAIDs was achieved on a Unison UK-Amino HILIC column (50mm×3mm i.d., particle size 3µm) with a linear gradient elution system composed of 10mM ammonium acetate (pH 6.8) and acetonitrile at a flow rate of 0.4mL/min. The mass spectra obtained by HILIC-MS showed base peak ions due to [M+H](+) for indomethacin, oxaprozin, ketoprofen, alminoprofen, zaltoprofen, tiaprofenic acid, pranoprofen, and ketoprofen-d3 and due to [M-H](-) for etodolac, ibuprofen, diclofenac, fenoprofen, loxoprofen, naproxen, and ibuprofen-d3. Recoveries of these thirteen NSAIDs in plasma were 34.8-113% and the lower limits of quantitation were 0.125-1.25µg/mL. The intra- and interday coefficient of variations for all drugs in plasma were less than 14.6%. The data obtained from actual plasma determinations of zaltoprofen, ibuprofen, and diclofenac are also presented.


Assuntos
Anti-Inflamatórios/sangue , Análise Química do Sangue , Monitoramento de Medicamentos , Espectrometria de Massas em Tandem , Acetatos/química , Acetonitrilas/química , Administração Oral , Adulto , Anti-Inflamatórios não Esteroides , Humanos , Interações Hidrofóbicas e Hidrofílicas , Masculino , Pessoa de Meia-Idade , Controle de Qualidade , Análise de Regressão , Reprodutibilidade dos Testes , Solventes/química
11.
Forensic Sci Int ; 227(1-3): 95-9, 2013 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-23290298

RESUMO

A sensitive method for the simultaneous determination of quazepam and two of its metabolites, 2-oxoquazepam and 3-hydroxy-2-oxoquazepam, in human urine was developed using gas chromatography-mass spectrometry (GC/MS) with an Rtx-5MS capillary column. The quazepam and its metabolites were extracted from human urine using a simple solid-phase extraction Oasis(®) HLB cartridge column, and the 3-hydroxy-2-oxoquazepam was derivatised using BSTFA/1%TMCS and pyridine at 60 °C for 30 min. The mass spectrometric detection of the analytes was performed in the full scan mode, m/z 60-480, and selected ion monitoring (SIM) mode, m/z 386, for quazepam; m/z 342, for 2-oxoquazepam; m/z 429, for 3-hydroxy-2-oxoquazepam-TMS; and m/z 284, for alprazolam-d5 (internal standard), by electron ionization. The calibration curves of quazepam and its metabolites in urine showed good linearity in the concentration range of 2.5-500 ng/0.2 ml of urine. The average recoveries of quazepam and its metabolites from 0.2 ml of urine containing 500 ng and 50 ng of each drug were 71-83% and 88-90%, respectively. The limits of detection of quazepam, 2-oxoquazepam and 3-hydroxy-2-quazepam in urine by the selected ion monitoring mode were 0.096-0.37 ng/ml. This method would be applicable to other forensic biological materials containing low concentrations of quazepam and its metabolites.


Assuntos
Benzodiazepinas/urina , Hipnóticos e Sedativos/urina , Benzodiazepinonas/urina , Toxicologia Forense , Cromatografia Gasosa-Espectrometria de Massas/métodos , Humanos , Masculino , Extração em Fase Sólida , Detecção do Abuso de Substâncias/instrumentação , Triazolam/análogos & derivados , Triazolam/urina
12.
Leg Med (Tokyo) ; 14(5): 267-71, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22546247

RESUMO

Dimemorfan was extracted from human plasma samples (100 µL) using MonoTip C(18) tips, which were packed with a C(18)-bonded monolithic silica gel attached to the inside of the tip. The samples, which contained dimemorfan and trimeprazine as an internal standard (IS), were mixed with 300 µL of distilled water and 50 µL of 1M glycine-sodium hydroxide buffer (pH 10). The mixture was extracted onto the C(18) phase of the tip by 20 sequential aspirating/dispensing cycles using a manual micropipettor. The analytes retained on the C(18) phase were then eluted with methanol by five sequential aspirating/dispensing cycles. The eluate was injected directly into a gas chromatograph and detected by a mass spectrometer with selected ion monitoring in positive electron ionization mode. An Equity-5 fused silica capillary column (30 m × 0.32 mm i.d., film thickness 0.25 µm) gave adequate separation of the dimemorfan, IS, and impurities. The recoveries of dimemorfan and the IS spiked into plasma were ≥83%. The regression equation for dimemorfan showed excellent linearity from 0.25 to 32.0 ng/100 µL of plasma, and the limit of detection was 0.125 ng/100 µL of plasma. The maximum intra-day and inter-day relative standard deviations were 13%, while accuracy ranged from 88% to 105%. Dimemorfan was stable for at least 12 h at 4°C, 4 weeks at -80°C, and three freeze-thaw cycles in plasma. This new method is expected to have application as a pretreatment for the rapid, simple, and quantitative determination of dimemorfan in plasma samples.


Assuntos
Morfinanos/análise , Plasma/química , Extração em Fase Sólida/métodos , Trimeprazina/análise , Antipruriginosos/análise , Antitussígenos/análise , Humanos , Extração em Fase Sólida/instrumentação
13.
J Sep Sci ; 35(5-6): 726-33, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22271670

RESUMO

A novel method is described for the extraction of methamphetamine, amphetamine, and methylenedioxyphenylalkylamine designer drugs, such as 3,4-methylenedioxy-methamphetamine, 3,4-methylenedioxyamphetamine, 3,4-methylenedioxyethylamphetamine, N-methyl-1-(3,4-methylenedioxyphenyl)-2-butanamine, and 3,4-(methylenedioxyphenyl)-2-butanamine, from human whole blood using molecularly imprinted solid-phase extraction as highly selective sample clean-up technique. Whole blood samples were diluted with 10 mmol/L ammonium acetate (pH 8.6) and applied to a SupelMIP-Amphetamine molecularly imprinted solid-phase extraction cartridge. The cartridge was then washed to eliminate interferences, and the amphetamines of interest were eluted with formic acid/methanol (1:100, v/v). After derivatization with trifluoroacetic anhydride, the analytes were quantified using gas chromatography-mass spectrometry. Recoveries of the seven amphetamines spiked into whole blood were 89.1-102%. The limits of quantification for each compound in 200 µL of whole blood were between 0.25 and 1.0 ng. The maximum intra- and inter-day coefficients of variation were 9.96 and 13.8%, respectively. The results show that methamphetamine, amphetamine, and methylenedioxyphenylalkyl-amine designer drugs can be efficiently extracted from crude biological samples such as whole blood by molecularly imprinted solid-phase extraction with good reproducibility. This extraction method will be useful for the pretreatment of human samples before gas chromatography-mass spectrometry.


Assuntos
Anfetamina/isolamento & purificação , Anfetaminas/isolamento & purificação , Drogas Desenhadas/isolamento & purificação , Polímeros/química , Extração em Fase Sólida/métodos , 3,4-Metilenodioxianfetamina/análogos & derivados , 3,4-Metilenodioxianfetamina/sangue , 3,4-Metilenodioxianfetamina/isolamento & purificação , Adsorção , Anfetamina/sangue , Anfetaminas/sangue , Drogas Desenhadas/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Humanos , Impressão Molecular , Polímeros/síntese química , Extração em Fase Sólida/instrumentação
14.
Anal Bioanal Chem ; 401(7): 2215-23, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21874269

RESUMO

Dextromethorphan was extracted from human plasma samples (100 µL) using MonoTip C(18) tips, which are packed with C(18)-bonded monolithic silica gel that is attached to the inside of the tip. The samples, which contained dextromethorphan and trimeprazine as an internal standard (IS), were mixed with 200 µL of distilled water and 50 µL of 1 mol/L glycine-sodium hydroxide buffer (pH 10). The mixture was extracted to the C(18) phase of the tip by 20 sequential aspirating/dispensing cycles using a manual micropipettor. The analytes retained on the C(18) phase were then eluted with methanol by five sequential aspirating/dispensing cycles. The eluate was injected directly into a gas chromatograph and detected by a mass spectrometer with selected ion monitoring in positive electron ionization mode. An Equity-5 fused silica capillary column (30 m × 0.32 mm i.d., film thickness 0.5 µm) gave adequate separation of the dextromethorphan, IS, and impurities. The recoveries of dextromethorphan and the IS spiked into plasma were >87.4%. The regression equation for dextromethorphan showed excellent linearity from 2.5 to 320 ng/mL of plasma, and the limit of detection was 1.25 ng/mL of plasma. The intraday and interday coefficients of variation were less than 10.5% and 14.7%, respectively. The accuracy ranged from 91.9% to 107%. The validated method was successfully used to quantify the plasma concentration of dextromethorphan in a human subject after oral administration of the drug.


Assuntos
Dextrometorfano/sangue , Antagonistas de Aminoácidos Excitatórios/sangue , Cromatografia Gasosa-Espectrometria de Massas , Extração em Fase Sólida , Administração Oral , Dextrometorfano/administração & dosagem , Antagonistas de Aminoácidos Excitatórios/administração & dosagem , Humanos , Masculino , Pessoa de Meia-Idade , Padrões de Referência , Sensibilidade e Especificidade
15.
J Chromatogr A ; 1218(18): 2521-7, 2011 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-21429493

RESUMO

Solid-phase extraction (SPE) using micropipette tips is a useful technique to prepare samples prior to mass spectrometry. However, most commercial SPE tips have loading capacities that are insufficient for quantitative determination. In this paper, we describe a rapid method for quantitative microanalysis of five phenothiazine derivatives, chlorpromazine, levomepromazine, promazine, promethazine and trimeprazine, using a recently introduced C(18) monolithic silica SPE tip, the MonoTip C(18), for extraction from human plasma. The drugs could be extracted within 5 min from 0.1-mL plasma samples, eluted with methanol, and the eluate injected directly into a gas chromatograph prior to mass spectrometry analysis. Only 0.7 mL of solvent was required for each step of the extraction process. The recoveries of the five phenothiazines spiked into plasma were 91-95% and the limits of quantification for each drug were between 0.25 and 2.0 ng/0.1 mL. The maximum intra- and inter-day coefficient of variation was 11%. The validated method was successfully used to quantify the plasma concentration of levemepromazine in a human subject after oral administration of the drug. This new method is expected to have wide applications as a pretreatment for the rapid, quantitative determination of drug concentrations in plasma samples.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas/métodos , Fenotiazinas/sangue , Extração em Fase Sólida/instrumentação , Extração em Fase Sólida/métodos , Adulto , Estabilidade de Medicamentos , Feminino , Humanos , Modelos Lineares , Metotrimeprazina/análogos & derivados , Metotrimeprazina/sangue , Metotrimeprazina/farmacocinética , Porosidade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Dióxido de Silício
16.
Anal Bioanal Chem ; 394(4): 1161-70, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19387622

RESUMO

This paper describes a fully automated on-line method combining in-tube solid-phase microextraction (SPME) in which sample clean-up and enrichment are conducted through an open tubular fused-silica capillary column and high-performance liquid chromatography (HPLC)/tandem mass spectrometry (MS/MS) detection for the determination of six butyrophenone derivatives (moperone, floropipamide, haloperidol, spiroperidol, bromperidol, and pimozide) in human plasma samples. The six butyrophenones were extracted by repeatedly aspirating and dispensing plasma sample solutions on a DB-17 capillary column (60 cm x 0.32 mm i.d., film thickness 0.25 microm). The analytes retained on the inner surface of the capillary column were then eluted into an acetonitrile-rich mobile phase using a gradient separation technique. Extraction efficiencies ranged from 12.7% to 31.8% for moperone, spiroperidol, and pimozide, and from 1.08% to 4.86% for floropipamide, haloperidol, and bromperidol. The regression equations for all compounds showed excellent linearity, ranging from 0.05 to 50 ng/0.1 mL of plasma, except for moperone and spiroperidol (0.01 to 50 ng/0.1 mL). The limits of detection and quantification in plasma for each drug were 0.03-0.2 and 0.1-0.5 ng/mL, respectively. The intra- and inter-day coefficients of variation for all compounds in plasma were not greater than 13.7%.


Assuntos
Butirofenonas/sangue , Microextração em Fase Sólida/métodos , Cromatografia Líquida de Alta Pressão , Humanos , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectrometria de Massas em Tandem , Fatores de Tempo
17.
Rapid Commun Mass Spectrom ; 22(15): 2333-41, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18618924

RESUMO

Diazepam and its major metabolites, nordazepam, temazepam and oxazepam, in human urine samples, were analyzed by liquid chromatography (LC)/tandem mass spectrometry (MS/MS) using a hydrophilic polymer column (MSpak GF-310 4B), which enables direct injection of crude biological samples. Matrix compounds in urine were eluted first from the column, while the target compounds were retained on the polymer stationary phase. The analytes retained on the column were then eluted into an acetonitrile-rich mobile phase using a gradient separation technique. All compounds showed base-peak ions due to [M+H]+ ions on LC/MS with positive ion electrospray ionization, and product ions were produced from each [M+H]+ ion by LC/MS/MS. Quantification was performed by selected reaction monitoring. All compounds spiked into urine showed method recoveries of 50.1-82.0%. The regression equations for all compounds showed excellent linearity in the range of 0.5-500 ng/mL of urine. The limits of detection and quantification for each compound were 0.1 and 0.5 ng/mL of urine, respectively. The intra- and inter-day coefficients of variation for all compounds in urine were not greater than 9.6%. The data obtained from actual determination of diazepam and its three metabolites, oxazepam, nordazepam and temazepam, in human urine after oral administration of diazepam, are also presented.


Assuntos
Ansiolíticos/análise , Ansiolíticos/metabolismo , Ansiolíticos/urina , Cromatografia Líquida/métodos , Diazepam/análise , Diazepam/metabolismo , Diazepam/urina , Espectrometria de Massas em Tandem/métodos , Administração Oral , Adulto , Ansiolíticos/química , Diazepam/química , Estabilidade de Medicamentos , Congelamento , Humanos , Pessoa de Meia-Idade , Estrutura Molecular , Controle de Qualidade , Padrões de Referência , Análise de Regressão , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectrometria de Massas por Ionização por Electrospray , Fatores de Tempo
18.
J Sep Sci ; 31(12): 2265-71, 2008 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-18546392

RESUMO

A method for the simultaneous extraction of four tricyclic antidepressants from human plasma samples using pipette tip SPE with MonoTip C(18) tips is presented. Human plasma (0.1 mL) containing four tricyclic antidepressants (amitriptyline, amoxapine, imipramine, and trimipramine) and an internal standard (IS), protriptyline, was mixed with 0.4 mL of distilled water and 100 microL 1 M NaOH solution. After centrifugation of the mixture, the supernatant was extracted to the C(18) phase of the tip by 20 repeated aspirating/dispensing cycles using a manual micropipettor. The analytes retained in the tip were eluted with methanol by five repeated aspirating/dispensing cycles. Without evaporation and reconstitution, the eluate was directly injected into a gas chromatograph injector and detected by a mass spectrometer with SIM in the positive-ion electron impact mode. Recovery of the four antidepressants and IS spiked into human plasma was 80.2-92.1%. The regression equations for the four antidepressants showed excellent linearity in the range of 0.2-40 ng/0.1 mL. LODs and LOQs for the four drugs were 0.05-0.2 ng/0.1 mL and 0.2-0.5 ng/0.1 mL, respectively. Intra- and interday CVs for the four drugs in plasma were no greater than 9.5%.


Assuntos
Antidepressivos Tricíclicos/sangue , Cromatografia Gasosa-Espectrometria de Massas/métodos , Extração em Fase Sólida/métodos , Amoxapina/administração & dosagem , Amoxapina/sangue , Antidepressivos Tricíclicos/administração & dosagem , Antidepressivos Tricíclicos/química , Análise Química do Sangue/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Extração em Fase Sólida/instrumentação
19.
Biomed Chromatogr ; 22(7): 702-11, 2008 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-18318013

RESUMO

A detailed procedure for the analysis of four beta-blockers, acebutolol, labetalol, metoprolol and propranolol, in human plasma by high-performance liquid chromatography (LC)-tandem mass spectrometry (MS-MS) using an MSpak GF column, which enables direct injection of crude plasma samples, is presented. Protein and/or macromolecule matrix compounds were eluted first from the column, while the drugs were retained on the polymer stationary phase of the MSpak GF column. The analytes retained on the column were then eluted into an acetonitrile-rich mobile phase using a gradient separation technique. All drugs showed base peak ions due to [M + H]+ ions by LC-MS with positive ion electrospray ionization, and the product ions were produced from each [M + H]+ ion by LC-MS-MS. Quantification was performed by selected reaction monitoring. The recoveries of the four beta-blockers spiked into plasma were 73.5-89.9%. The regression equations for all compounds showed excellent linearity in the range 10-1000 ng/mL of plasma, with the exception of propranolol (10-800 ng/mL). The limits of detection and quantification for each drug were 1-3 and 10 ng/mL, respectively, of plasma. The intra- and inter-day coefficients of variation for all drugs in plasma were not greater than 10.9%.


Assuntos
Antagonistas Adrenérgicos beta/sangue , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Acebutolol/sangue , Antagonistas Adrenérgicos beta/química , Humanos , Labetalol/sangue , Modelos Lineares , Metoprolol/sangue , Pindolol/sangue , Propranolol/sangue , Sensibilidade e Especificidade
20.
J AOAC Int ; 91(6): 1354-62, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-19202796

RESUMO

Chlorpromazine, levomepromazine, promazine, triflupromazine, and trimeprazine were simultaneously determined in human whole blood and plasma by combining headspace solid-phase microextraction and gas chromatography with nitrogen-phosphorus detection. Extraction efficiency for the phenothiazine derivatives was 0.013-0.117% for both sample types. Regression equations were linear [correlation coefficient (r) = 0.9951-0.9999] within the range 2.5-200 ng/0.5 mL for triflupromazine and trimeprazine, and 6.3-200 ng/0.5 mL for chlorpromazine, levomepromazine, and promazine. The limit of detection for each compound was 0.2-3.9 ng/0.5 mL whole blood and plasma. Intraday and interday coefficients of variation for all phenothiazines in both human samples were commonly < 15 and 20%, respectively. We also report the determination of levomepromazine in human plasma after oral administration.


Assuntos
Antipsicóticos/sangue , Fenotiazinas/sangue , Adulto , Cromatografia Gasosa , Feminino , Humanos , Indicadores e Reagentes , Nitrogênio/química , Fósforo/química , Controle de Qualidade , Padrões de Referência , Microextração em Fase Sólida
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...