Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Environ Pollut ; 90(1): 25-31, 1995.
Artigo em Inglês | MEDLINE | ID: mdl-15091497

RESUMO

In the context of global climate change, an understanding of the long-term effects of increasing concentrations of atmospheric trace gases (carbon dioxide, CO(2), ozone, O(3), oxides of nitrogen, NO(x) etc.) on both cultivated and native vegetation is of utmost importance. Over the years, under field conditions, various trace gas-vegetation exposure methodologies with differing advantages and disadvantages have been used. Because of these variable criteria, with elevated O(3) or CO(2) levels, at the present time the approach of free-air experimental-release of the gas into study plots is attracting much attention. However, in the case of CO(2), this approach (using 15 m diameter study plot with a single circular array of vent pipes) has proven to be cost prohibitive (about 59000-98000 dollars/year/replicate) due to the consumption of significant quantities of the gas to perform the experiment (CO(2) level elevated to 400 ppm above the ambient). Therefore, in this paper, we present a new approach consisting of a dual, concentric exposure array of vertical risers or vent pipes. The purpose of the outer array (17 m diameter) is to vent ambient air outward and toward the incoming wind, thus providing an air curtain to reduce the velocity of that incoming wind to simulate the mode or the most frequently occurring wind speed at the study site. The inner array (15 m diameter) vents the required elevated levels of trace gases (CO(2), O(3), etc.) into the study plot. This dual array system is designed to provide spatial homogeneity (shown through diffusion modeling) of the desired trace-gas levels within the study plot and to also reduce its consumption. As an example, while in the single-array free-air CO(2)-release system the consumption of CO(2) to elevate its ambient concentration by 400 ppm is calculated to be about 980 tons/year/replicate, it is estimated that in the dual array system it would be approximately 590 tons/year/replicate. Thus, the dual array system may provide substantial cost savings (24000-39000 dollars/year/replicate) in the CO(2) consumption (60-100 dollars/ton of CO(2)) alone. Similarly, benefits in the requirements of other trace gases (O(3), NO(x), etc.) are expected, in future multivariate studies on global climate change.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...