Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 80
Filtrar
1.
J Cardiol Cases ; 30(1): 20-23, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39007041

RESUMO

An 83-year-old woman with claudication in the right lower extremity was referred to our hospital. Since angiography showed severe stenosis with a severely calcified lesion extending from the ostial to proximal part of the right superficial femoral artery (SFA), endovascular therapy (EVT) with the Jetstream™ atherectomy system (Boston Scientific, Marlborough, MA, USA) and paclitaxel-coated balloon (PCB) was performed. Atherectomy was performed using the Jetstream™ atherectomy catheter SC 1.85, followed by an additional atherectomy using the Jetstream™ atherectomy catheter XC 2.1/3.0. Subsequently, angiography and intravascular ultrasound (IVUS) images showed the enlargement of lumen area due to the reduction of calcified plaque, but even some of the healthy media on the side free of calcified plaque had been removed. Next, a PCB dilation was performed, and the final angiography showed adequate dilation. However, the symptoms recurred 9 months after EVT. Angiography revealed an enlarged vessel suggestive of pseudoaneurysm at the ostial part of the right SFA and severe stenosis distal to the enlarged vessel. IVUS images showed a pseudoaneurysm and severe stenosis due to calcified nodules distal to the pseudoaneurysm. This case suggests that pseudoaneurysm is a potential complication of EVT with the Jetstream™ atherectomy system and PCB for SFA lesions. Learning objective: The Jetstream™ atherectomy system (Boston Scientific, Marlborough, MA, USA) has developed to improve outcomes for femoropopliteal artery lesions with severely calcified lesions in lower extremity arterial disease by removing calcified plaque and improving vascular compliance. Several clinical reports demonstrated durable patency rates and low complication rates after endovascular therapy using the atherectomy device. However, pseudoaneurysm is a potential complication of endovascular therapy with the Jetstream™ atherectomy system.

2.
Artigo em Inglês | MEDLINE | ID: mdl-39067506

RESUMO

OBJECTIVE: This study aimed to determine the impact of infrapopliteal (IP) revascularisation establishing in line flow to the wound (IFW) on wound healing in chronic limb threatening ischaemia (CLTI), using a core laboratory assessment for wounds and in line flow. METHODS: The Wound-directed Angiosome RevasculaRIzation apprOach to patients with cRitical limb iSchaemia (WARRIORS) multicentre observational study enrolled patients with CLTI with tissue loss undergoing IP revascularisation in Japan, with scheduled two year follow up. The primary outcome measure was complete wound healing, defined as achievement of complete epithelialisation of all wounds without major amputation. IP revascularisation establishing IFW was defined as revascularisation after which a tibiopedal artery that actually fed an injured pedal unit was patent. The incidence of wound healing was compared between the IFW and non-IFW groups using inverse probability of treatment weighting based on the propensity score. RESULTS: A total of 440 patients with CLTI (median age, 75 years; male, 64.1%; diabetes mellitus, 72.0%; dialysis, 57.7%) with tissue loss (Wound, Ischemia, and foot Infection stage 4, 66.4%) who underwent IP revascularisation (endovascular procedure, n = 304; bypass grafting, n = 136) between October 2017 and June 2020 were registered. During a median follow up of 23.6 months, 51.1% achieved wound healing. Successful IP revascularisation with IFW was achieved in 68.2%. After analysis, the IFW group had a higher incidence of wound healing than the non-IFW group (34.5 vs. 16.1 per 100 person years; p = .030). The association of IFW with wound healing was not statistically different between patients undergoing bypass grafting and those undergoing an endovascular procedure (p for interaction = .38). There was no statistically significant interaction effect between IFW and direct revascularisation for wound healing (p for interaction = .51). CONCLUSION: IP revascularisation establishing IFW was statistically significantly associated with a higher wound healing rate in patients with CLTI.

3.
Clin Cardiol ; 47(6): e24310, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38888132

RESUMO

BACKGROUNDS: Lead dislodgement is a severe complication in cardiac implantable electronic device (CIED) implantation. Inflammation after CIED implantation results in the development of adhesions between lead and tissues, resulting in the lead becoming fixed in the body. In patients with immunosuppressive therapy, however, adhesion is inhibited by anti-inflammatory effects. However, the association between lead dislodgement and immunosuppressive therapy has not been clarified. The purpose of this study was to investigate the association between lead dislodgement and immunosuppressive therapy. HYPOTHESIS: We hypothesized that lead dislodgement more frequently occur in patients with immunosuppressive therapy than those without. METHODS: In total, 651 consecutive patients who underwent CIED implantation or lead addition (age, 76 ± 11 years; and males, 374 [58%], high voltage device, 121 [19%], lead addition 23 [4%]) were retrospectively enrolled. Immunosuppressive therapy was with regular steroids or immunosuppressants. Lead placement was guided by fluoroscopy, and active fixation leads were used. Restraint of the upper limb by chest tape was performed for 1 week after the procedure. Lead dislodgement was defined as a change in lead position and/or lead failure requiring reoperation. RESULTS: Twenty (3.1%) patients received immunosuppressive therapy. Among these, 15 (2.3%) patients regularly took steroids and 8 (1.2%) took immunosuppressants. Lead dislodgement occurred in 10 (1.5%) patients. Lead dislodgement was more frequent in patients with immunosuppressive therapy than in those without (3 [15%] vs. 7 [1%], p = 0.003). CONCLUSION: In patients with CIED implantation or lead addition, lead dislodgement is more frequent in patients with immunosuppressive therapy than in those without.


Assuntos
Desfibriladores Implantáveis , Imunossupressores , Marca-Passo Artificial , Humanos , Masculino , Feminino , Idoso , Estudos Retrospectivos , Imunossupressores/efeitos adversos , Imunossupressores/uso terapêutico , Idoso de 80 Anos ou mais , Fatores de Risco , Resultado do Tratamento , Pessoa de Meia-Idade , Remoção de Dispositivo , Dispositivos de Terapia de Ressincronização Cardíaca
4.
ESC Heart Fail ; 2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38853626

RESUMO

AIMS: Atrial fibrillation (AF) and heart failure (HF) affect each other and are often co-morbid. The fact that HF development is not uncommon even after ablation suggests that we need a deeper understanding of the pathology of these conditions. Atrial myocardial degeneration is an underlying factor in AF patients and may be associated with HF development after ablation. This study aimed to investigate the impact of low-voltage areas (LVAs) on HF prognosis after AF ablation. METHODS AND RESULTS: This observational study included 1481 consecutive patients undergoing initial ablation for AF. Left atrial LVAs were defined as regions with a bipolar peak-to-peak voltage of <0.50 mV. Patients were divided into three groups: no LVA (LVA size indexed to body surface area <3 cm2/m2, n = 1129), small LVA (3-10 cm2/m2, n = 217), and extensive LVA (≥10 cm2/m2, n = 135). A composite endpoint of HF hospitalization or death occurred more frequently in patients with larger LVAs (3.3% vs. 6.5% vs. 13.3%, P < 0.0001) during the 3-year follow up period. The extent of LVAs was independently related to the risk of the composite endpoint with an adjusted hazard ratio of 1.55 (95% confidence interval, 1.16-2.10) for each additional step of LVA classification (P = 0.003). CONCLUSIONS: LVA presence and its extent were associated with frequent HF hospitalization and death. Underlying atrial myopathy appears to define a poor HF prognosis after AF ablation.

5.
Europace ; 26(5)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38767127

RESUMO

AIMS: Understanding of the tissue cooling properties of cryoballoon ablation during pulmonary vein (PV) isolation is lacking. The purpose of this study was to delineate the depth of the tissue cooling effect during cryoballoon freezing at the pulmonary venous ostium. METHODS AND RESULTS: A left atrial-PV model was constructed using a three-dimensional printer with data from a patient to which porcine thigh muscle of various thicknesses could be affixed. The model was placed in a 37°C water tank with a PV water flow at a rate that mimicked biological blood flow. Cryofreezing at the PV ostium was performed five times each for sliced porcine thigh muscle of 2, 4, and 6 mm thickness, and sliced muscle cooling on the side opposite the balloon was monitored. The cooling effect was assessed using the average temperature of 12 evenly distributed thermocouples covering the roof region of the left superior PV. Tissue cooling effects were in the order of the 2, 4, and 6 mm thicknesses, with an average temperature of -41.4 ± 4.2°C for 2 mm, -33.0 ± 4.0°C for 4 mm, and 8.0 ± 8.7°C for 6 mm at 180 s (P for trend <0.0001). In addition, tissue temperature drops were steeper in thin muscle (maximum temperature drop per 5 s: 5.2 ± 0.9°C, 3.9 ± 0.7°C, and 1.3 ± 0.7°C, P for trend <0.0001). CONCLUSION: The cooling effect of cryoballoon freezing is weaker in the deeper layers. Cryoballoon ablation should be performed with consideration to myocardial thickness.


Assuntos
Criocirurgia , Veias Pulmonares , Criocirurgia/métodos , Criocirurgia/instrumentação , Criocirurgia/efeitos adversos , Animais , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia , Suínos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Humanos , Modelos Cardiovasculares , Músculo Esquelético/cirurgia , Modelos Anatômicos
6.
J Cardiol ; 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38641319

RESUMO

BACKGROUND: The relationship between baseline yellow plaque (YP) and vascular response after stent implantation has not been fully investigated. METHODS: This was a sub-analysis of the Collaboration-1 study (multicenter, retrospective, observational study). A total of 88 lesions from 80 patients with chronic coronary syndrome who underwent percutaneous coronary intervention were analyzed. Optical coherence tomography (OCT) and coronary angioscopy (CAS) were serially performed immediately and 11 months after stent implantation. YP was defined as the stented segment with yellow or intensive yellow color assessed by CAS. Neoatherosclerosis was defined as a lipid or calcified neointima assessed by OCT. OCT and CAS findings at 11 months were compared between lesions with baseline YP (YP group) and lesions without baseline YP (Non-YP group). RESULTS: Baseline YP was detected in 37 lesions (42 %). OCT findings at 11 months showed that the incidence of neoatherosclerosis was significantly higher in the YP group (11 % versus 0 %, p = 0.028) and mean neointimal thickness tended to be lower (104 ±â€¯43 µm versus 120 ±â€¯48 µm, p = 0.098). CAS findings at 11 months demonstrated that the dominant and minimum neointimal coverage grades were significantly lower (p = 0.049 and P = 0.026) and maximum yellow color grade was significantly higher (p < 0.001) in the YP group. CONCLUSIONS: Baseline YP affected the incidence of neoatherosclerosis as well as poor neointimal coverage at 11 months after stent implantation.

7.
Am J Cardiol ; 218: 43-50, 2024 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-38479607

RESUMO

Low-voltage areas have been used as atrial structural substrates in estimating fibrotic degeneration in patients with atrial fibrillation (AF). The high-resolution maps obtained by recently developed mapping catheters allow the visualization of several functional abnormalities. We investigated the association between left atrial (LA) functional abnormal findings on a high-resolution substrate map and AF recurrence in patients who underwent pulmonary vein isolation without any additional LA substrate ablation. This observational study included 100 consecutive patients who underwent second ablation for AF (paroxysmal, 48%; persistent, 52%). Patients with extra-pulmonary-vein LA substrate ablation during the initial and second ablation were excluded. LA mapping was performed using a 64-pole mini-basket catheter on the RHYTHMIA mapping system (Boston Scientific, Marlborough [Cambridge] Massachusetts). Patients were followed for 2 years. AF recurrence developed in 39 (39%) patients. On the high-resolution substrate map, AF recurrence was associated with the presence of the following findings: low-voltage areas (<1.0 mV, >5 cm2; hazard ratio [HR] = 2.53; 95% confidence interval [CI] = 1.30 to 4.93; p <0.006), fractionated-electrogram areas (≥5 peaks, >5 cm2; HR = 2.15, 95% CI = 1.10 to 4.19; p = 0.025), LA conduction time of >130 ms (HR = 3.11, 95% CI = 1.65 to 5.88, p <0.0001), deceleration zone (≥5 isochrones/cm2; HR = 1.97, 95% CI = 1.04 to 3.37, p = 0.039), and multiple septal break-out points (HR = 3.27, 95% CI = 1.50 to 7.16, p = 0.003). Accumulation of these risk factors increased AF recurrence in a stepwise manner, with an HR = 1.90, 95% CI = 1.44 to 2.52, p <0.00001 for each additional risk factor. In conclusion, a high-resolution map revealed new LA functional substrates associated with AF recurrence. Implementation of functional substrates may improve the prediction of AF recurrence after ablation, and possibly aid the development of tailored AF ablation strategies.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Átrios do Coração , Frequência Cardíaca , Veias Pulmonares/cirurgia , Recidiva , Fatores de Risco , Resultado do Tratamento
8.
J Vasc Surg Cases Innov Tech ; 10(3): 101447, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38510091

RESUMO

A fluoropolymer-based drug-eluting stent was implanted in an arteriovenous graft outflow venous stenosis. Two and a half years later, due to a local infection, the stent was removed surgically, and a pathological evaluation was conducted. The stent struts exhibited partial endothelial cell coverage, with the remaining surface predominantly covered by fibrin. Notably, there was no evidence of restenosis or aneurysmal change.

9.
J Cardiovasc Electrophysiol ; 35(4): 775-784, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38375957

RESUMO

INTRODUCTION: Left atrial low-voltage areas (LVAs) are known to be correlated with atrial scarring and atrial fibrillation (AF) recurrence after ablation. However, the association between LVAs and glycemic status before ablation has not been fully clarified. The purpose of this study was to investigate associations among the prevalence of diabetes mellitus (DM), glycemic control, and the prevalence of LVAs in patients with AF ablation. METHODS: In total, 912 (age, 68 ± 10 years; female, 299 [33%]; persistent AF, 513 [56%]) consecutive patients who underwent initial AF ablation were included. A preprocedure glycated hemoglobin A1c (HbA1c) ≥7% was set as the cutoff for poor glycemic control in patients with DM. LVAs were defined as areas with a bipolar voltage of <0.5 mV covering ≥5 cm2 of left atrium. RESULTS: LVAs existed in 208 (23%) patients, and 168 (18%) patients had DM. LVAs were found more frequently in patients with DM and poor glycemic control. On multivariate analysis, DM with HbA1c ≥7% was an independent predictor of LVAs (odds ratio, 3.3; 95% confidence interval: 1.6-6.7; p = .001). In patients with LVAs, freedom from AF recurrence during the 24-month study period was significantly lower in patients who had DM with HbA1c ≥7% than in those without DM (37.9% vs. 54.7%, p = .02). CONCLUSION: In patients with AF ablation, LVAs were found more frequently in patients with DM and poor glycemic control. DM with HbA1c ≥7% was an independent predictor of LVAs.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Diabetes Mellitus , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Prevalência , Hemoglobinas Glicadas , Controle Glicêmico , Átrios do Coração/cirurgia , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/epidemiologia , Diabetes Mellitus/etiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva , Resultado do Tratamento
10.
J Vasc Interv Radiol ; 35(2): 259-268, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37898458

RESUMO

PURPOSE: To investigate the impact of compliance with recommended procedural techniques on the midterm patency of a fluoropolymer-based drug-eluting stent (FP-DES) in the femoropopliteal artery. MATERIALS AND METHODS: This retrospective study included 200 femoropopliteal lesions (chronic limb-threatening ischemia, 59%; chronic total occlusion, 41%) in 173 patients (male, 66%; diabetes mellitus, 62%; hemodialysis, 40%) with lower extremity arterial disease who underwent intravascular ultrasound (IVUS)-guided endovascular therapy with FP-DES between January 2016 and July 2021. The primary outcome measure was restenosis, defined as a peak systolic velocity ratio of >2.4 based on the duplex US findings. The association between procedural techniques and incidence of restenosis was investigated using Cox proportional hazards regression models. RESULTS: The 2-year cumulative incidence of restenosis was 19.5% (SD ± 3.3). Multivariate analysis revealed that noncompliance with recommended procedural techniques, such as plaque burden at the stent edge of <50%, a minimum stent area (MSA) of >12 mm2, and stent placement within the P1 segment, was independently associated with an increased risk of restenosis (hazard ratios [HRs], 3.22, 4.71, and 4.67 and P = .004, P < .001, and P < .001, respectively). The 2-year restenosis risk for procedures performed in compliance with all 3-technical criteria was 8.4% (SD ± 3.4), whereas the risks for those in compliance with 2-technical criteria or 0- or 1-technical criteria were 25.0% (SD ± 6.2) and 48.6% (SD ± 10.4), respectively. HRs relative to 3-technical criteria compliance were 3.79 (P = .007) and 11.85 (P < .001), respectively. CONCLUSIONS: Noncompliance with recommended procedural techniques, including plaque burden at the stent edge of <50%, MSA of >12 mm2, and stent placement within the P1 segment, was significantly associated with an increased risk of 2-year restenosis after FP-DES implantation in the femoropopliteal artery.


Assuntos
Stents Farmacológicos , Doença Arterial Periférica , Humanos , Masculino , Artéria Femoral/diagnóstico por imagem , Artéria Poplítea/diagnóstico por imagem , Polímeros de Fluorcarboneto , Estudos Retrospectivos , Resultado do Tratamento , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/terapia , Grau de Desobstrução Vascular , Desenho de Prótese
12.
J Cardiovasc Electrophysiol ; 35(1): 171-181, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38018401

RESUMO

INTRODUCTION: Atrial fibrillation (AF) is accompanied by various types of remodeling, including volumetric enlargement and histological degeneration. Electrical remodeling reportedly reflects histological degeneration. PURPOSE: To clarify the differences in determinants and clinical impacts among types of remodeling. METHODS: This observational study included 1118 consecutive patients undergoing initial ablation for AF. Patients were divided into four groups: minimal remodeling (left atrial volume index [LAVI] < mean value and no low-voltage area [LVA], n = 477); volumetric remodeling (LAVI ≥ mean value and no LVA, n = 361); electrical remodeling (LAVI < mean value and LVA presence, n = 96); and combined remodeling (LAVI ≥ mean value and LVA presence, n = 184). AF recurrence and other clinical outcomes were followed up for 2 and 5 years, respectively. RESULTS: Major determinants of each remodeling pattern were high age for electrical (odds ratio = 2.32, 95% confidence interval = 1.68-3.25) and combined remodeling (2.57, 1.88-3.49); female for electrical (3.85, 2.21-6.71) and combined remodeling (4.92, 2.90-8.25); persistent AF for combined remodeling (7.09, 3.75-13.4); and heart failure for volumetric (1.71, 1.51-2.53) and combined remodeling (2.21, 1.30-3.75). Recurrence rate after initial ablation increased in the order of minimal remodeling (20.1%), volumetric (27.4%) or electrical remodeling (36.5%), and combined remodeling (50.0%, p < .0001). A composite endpoint of heart failure, stroke, and death occurred in the order of minimal (3.4%), volumetric (7.5%) or electrical (8.3%), and combined remodeling (15.2%, p < .0001). CONCLUSION: Volumetric, electrical, and combined remodeling were each associated with a unique patient background, and defined rhythm and other clinical outcomes.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Remodelamento Atrial , Insuficiência Cardíaca , Feminino , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Recidiva , Resultado do Tratamento , Masculino
13.
Pacing Clin Electrophysiol ; 47(1): 28-35, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38029377

RESUMO

BACKGROUND: Recently, a new OCTARAY® mapping catheter was commercially launched. The catheter is designed to enable high-density mapping and precise signal recording via 48 small electrodes arranged on eight radiating splines. The purpose of this study was to compare bipolar voltage and low-voltage-area size, and mapping efficacy between the OCTARAY catheter and the PENTARAY® catheter METHODS: Twelve consecutive patients who underwent initial and second ablations for persistent atrial fibrillation within 2 years were considered for enrollment. Voltage mapping was performed twice, first during the initial ablation using the PENTARY catheter and second during the second ablation using the OCTARAY Long 3-3-3-3-3 (L3) catheter. RESULTS: Mean voltage with the OCTARAY-L3 catheter (1.64 ± 0.57 mV) was 32.3% greater than that with the PENTARAY catheter (1.24 ± 0.46 mV, p < .0001) in total left atrium. Low-voltage-area (<0.50 mV) size with the OCTARAY-L3 catheter was smaller than that with the PENTARAY catheter (6.9 ± 9.7 vs. 11.4 ± 13.0 cm2 , p < .0001). The OCTARAY-L3 catheter demonstrated greater efficacy than the PENTARAY catheter in terms of shorter mapping time (606 ± 99 vs. 782 ± 211 s, p = .008) and more mapping points (3,026 ± 838 vs. 781 ± 342 points, p < .0001). CONCLUSION: The OCTARAY catheter demonstrated higher voltage recordings, narrower low-voltage areas, and a more efficacious mapping procedure than the PENTARAY catheter.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Técnicas Eletrofisiológicas Cardíacas , Ablação por Cateter/métodos , Fibrilação Atrial/cirurgia , Átrios do Coração , Catéteres
14.
Int J Cardiol ; 399: 131686, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38151161

RESUMO

BACKGROUND: There are little clinical data on imaging-guided percutaneous coronary intervention (PCI) 1 year after the biodegradable-polymer sirolimus-eluting stents (BP-SES) implantation, when the polymer disappears. METHODS: We retrospectively analyzed 2455 patients who underwent successful PCI with BP-SES or durable-polymer everolimus-eluting stents (DP-EES) between September 2011 and March 2021, and compared 2-year clinical outcomes of BP-SES (n = 459) with DP-EES (n = 1996). The outcome measures were target lesion revascularization (TLR) and major adverse cardiac events (MACE), defined as a composite of cardiac death, myocardial infarction, target vessel revascularization, and stent thrombosis. Multivariate analysis using the Cox proportional hazard model and inverse probability weighting (IPW) analysis based on the propensity score were used to evaluate the clinical outcomes. RESULTS: The 2-year cumulative incidences of TLR (BP-SES: 4.9% vs. DP-SES: 6.1%, p = 0.304) and MACE (10.3% vs. 12.5%, p = 0.159) were similar between the two groups. Multivariable and IPW analysis revealed the risks of TLR (p = 0.388 and p = 0.500) and MACE (p = 0.139 and p = 0.083) also had no significant difference. There was a significant interaction between none/mild and moderate/severe calcification with respect to MACE and TLR (adjusted p for interaction = 0.036 and 0.047, respectively). The risk of MACE was significantly lower in BP-SES than in DP-EES in lesions with none/mild calcification (adjusted hazard ratio [aHR]: 0.53; 95% confidence interval [CI]: 0.30-0.91), while it was similar in those with moderate/severe calcification (aHR: 0.95; 95% CI: 0.58-1.55). CONCLUSIONS: Compared with DP-EES, BP-SES demonstrated durable 2-year clinical outcomes. However, BP-SES showed better clinical performance than DP-EES for lesions with none/mild calcification.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Humanos , Sirolimo/farmacologia , Intervenção Coronária Percutânea/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Everolimo , Polímeros , Implantes Absorvíveis , Desenho de Prótese , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia
15.
Heart Rhythm ; 21(4): 378-386, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38157922

RESUMO

BACKGROUND: Atrial cardiomyopathy is known as an underlying pathophysiological factor in the majority of patients with atrial fibrillation (AF). Left atrial low-voltage areas (LVAs) are reported to coincide with fibrosis and likely represent atrial cardiomyopathy. OBJECTIVE: The purpose of this study was to delineate differences in the long-term prognosis of patients stratified by the size of LVAs. METHODS: This observational study included 1488 consecutive patients undergoing initial ablation for AF. LVAs were defined as regions with a bipolar peak-to-peak voltage <0.50 mV. The total study population was divided into 3 groups stratified by LVA size: patients with no LVAs (n = 1136); those with small (<20 cm2) LVAs (n = 250) LVAs; and those with extensive (≥20 cm2) LVAs (n = 102). Composite endpoints of death, heart failure, and stroke were followed for up to 5 years. RESULTS: Composite endpoints developed in 105 of 1488 patients (7.1%), and AF recurrence occurred in 410 (27.6%). Composite endpoints developed more frequently in the order of patients with extensive LVAs (19.1%), small LVAs (10.8%), and no LVAs (5.1%) (P for trend <.0001). Multivariable analysis revealed that LVA presence was independently associated with higher incidence of composite endpoints, irrespective of AF recurrence (modified hazard ratio 1.73; 95% confidence interval 1.13-2.64; P = .011) CONCLUSION: LVA presence and its extent both were associated with poor long-term composite endpoints of death, heart failure, and stroke, irrespective of AF recurrence or other confounders. Underlying atrial cardiomyopathy seems to define a poor prognosis after AF ablation.


Assuntos
Fibrilação Atrial , Cardiomiopatias , Ablação por Cateter , Insuficiência Cardíaca , Acidente Vascular Cerebral , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Prognóstico , Seguimentos , Átrios do Coração , Cardiomiopatias/complicações , Cardiomiopatias/diagnóstico , Ablação por Cateter/efeitos adversos , Recidiva
17.
Catheter Cardiovasc Interv ; 102(6): 1114-1121, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37855184

RESUMO

AIM: The aim of the current study sought to investigate the angiographic patterns of restenosis after drug-coated balloon (DCB) angioplasty for femoropopliteal (FP) lesions and which repeat endovascular therapy (EVT) for DCB restenosis would provide more freedom from recurrent restenosis. METHODS: This retrospective multicenter study included 119 limbs (chronic limb-threatening ischemia [CLTI]: 55%, lesion length: 136.9 ± 89.6 mm, chronic total occlusion: 25%) of 95 patients (diabetes mellitus: 70%, hemodialysis: 56%) who were diagnosed with DCB restenosis between January 2018 and December 2019. The cases were classified into three groups based on angiographic patterns of restenosis: Class I: focal lesions ≤50 mm, Class II: diffuse lesions >50 mm, and Class III: totally occluded lesions. The DCB restenosis patterns and frequency and predictors of recurrent restenosis after repeated EVT (re-EVT) were investigated. RESULTS: The mean follow-up duration was 29.8 ± 9.5 months. Groups I, II, and III comprised of 30 (25.2%), 55 (46.2%), and 34 (29.0%) cases, respectively. The overall rate of 1-year freedom from recurrent restenosis was 58.2%. One-year rate of freedom from recurrent restenosis after repeat DCB was not statistically different from that after scaffolding (71.1% vs. 74.6%, respectively, p = 0.911); however, it was significantly better than that after noncoated balloon angioplasty (repeat DCB vs. noncoated balloon angioplasty: 71.1% vs. 25.7%, respectively, p < 0.001). Multivariate analysis demonstrated that CLTI (hazard ratio [HR]: 5.15, p < 0.001) and re-EVT with noncoated balloon (HR: 3.16, p < 0.001) were significantly associated with recurrent restenosis; however, Class III pattern of DCB restenosis was not associated with recurrent restenosis (HR: 1.04, p = 0.918). CONCLUSIONS: This study revealed the angiographic patterns of restenosis after DCB therapy for FP lesions and the 1-year rate of recurrent restenosis after repeat revascularization. Repeat DCB therapy demonstrated acceptable 1-year recurrent restenosis rates.


Assuntos
Angioplastia com Balão , Procedimentos Endovasculares , Doença Arterial Periférica , Humanos , Artéria Poplítea/diagnóstico por imagem , Resultado do Tratamento , Artéria Femoral/diagnóstico por imagem , Angioplastia com Balão/efeitos adversos , Prognóstico , Materiais Revestidos Biocompatíveis , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/terapia , Grau de Desobstrução Vascular
18.
Angiology ; : 33197231195671, 2023 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-37615068

RESUMO

Cholesterol crystal embolism (CCE) accompanied by a lower extremity wound is occasionally difficult to differentiate from chronic limb-threatening ischemia (CLTI) and treat. The present multi-center retrospective observational study investigated the clinical characteristics and prognosis of CCE with lower extremity wounds. Consecutive patients (n = 58) clinically diagnosed as CCE with lower extremity wounds between April 2010 and December 2019 were studied. CCE was diagnosed using histological findings, foot condition, renal impairment, and eosinophilia. The primary outcome was 1-year wound healing rate. Patients with CCE were compared with 1309 patients diagnosed with CLTI with tissue loss during the same study period. The CCE group had a significantly more severe Wound, Ischemia, and foot Infection (WIfI) classification compared with the CLTI group. After Kaplan-Meier analysis, the CCE group had a similar 1-year wound healing (55.1 vs 58.3%, P = .096) as the CLTI group. In multivariate stratified Cox regression analysis by WIfI stages, CCE was significantly associated with poor wound healing compared with CLTI [hazard ratio .36 (95% confidence interval .21-.62)]. In conclusion, among the similar WIfI clinical stages, wound healing was significantly worse in the CCE group than in the CLTI group.

19.
J Endovasc Ther ; : 15266028231186717, 2023 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-37477010

RESUMO

PURPOSE: Clinical trials have demonstrated the superiority of drug-coated balloon (DCB) to noncoated balloon angioplasty for the treatment of femoropopliteal (FP) lesions. In those trials, the difference of primary patency between DCB and noncoated angioplasty widens especially after 6 months, speculating that the antirestenosis effect of paclitaxel is manifested after 6 months. Factors associated with restenosis after 6 months differ from those associated with restenosis within 6 months. This study aimed to elucidate the prognostic factors associated with early (within 6 months) and late (after 6 months) restenosis following DCB treatment in real-world FP practice. MATERIALS AND METHODS: This multicenter, retrospective study analyzed 486 FP lesions (mean lesion length, 11.9±10.1 cm; chronic total occlusion, 21.0%) in 423 patients (diabetes mellitus, 59.3%; hemodialysis, 37.1%; chronic limb-threatening ischemia, 41.6%) who underwent successful DCB treatment between January 2018 and December 2019. The outcome measure was restenosis which is defined as a peak systolic velocity ratio >2.4 based on duplex ultrasound findings. Early and late restenosis were classified by the cutoff period of 6 months after the procedure. The associations of baseline and procedural characteristics with early and late restenosis were explored using Cox proportional hazards regression analysis. RESULTS: The mean follow-up period was 25.3±12.1 months. The 6, 12, 18, and 24 month cumulative incidences of restenosis were 7.4%±2.4%, 20.9%±3.9%, 29.9%±4.5%, and 38.4%±5.1%, respectively. During the follow-up period, early and late restenosis was evident in a total of 31 lesions and 138 lesions, respectively. Multivariate analysis revealed that chronic total occlusion (hazard ratio [HR], 2.29; 95% confidence interval [CI], 1.07-4.92; p=0.033) and superficial femoral artery ostial lesion (HR, 2.73; 95% CI, 1.28-5.80; p=0.009) were significantly associated with early restenosis. On the other hand, calcification circumference over 270° (HR, 1.67; 95% CI, 1.17-2.37; p=0.004), distal external elastic membrane diameter under 5 mm assessed by intravascular ultrasound (HR, 1.90; 95% CI, 1.29-2.79; p=0.001), and involving popliteal arterial lesion (HR, 1.54; 95% CI, 1.08-2.21; p=0.017) were significantly associated with late restenosis. CONCLUSION: The prognostic factors associated with late restenosis differed from those associated with early restenosis in the real-world FP-DCB practice. CLINICAL IMPACT: The current multicenter, retrospective study revealed that factors associated with early restenosis differed from those with late restenosis in the real-world FP-DCB practice. CTO and SFA ostial lesion were associated with early restenosis, while severe calcification, smaller vessel, and involving popliteal arterial lesions were associated with late restenosis.Early restenosis indicates "balloon failure" and would potentially result from recoil, which primary stent implantation might be required. On the other hand, late restenosis after 6 months would be attributed to "DCB failure", with inadequate drug uptake into the arterial wall, which might be minimized by the use of atherectomy devices.

20.
Am J Cardiol ; 203: 37-44, 2023 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-37481810

RESUMO

Atrial myocardial degeneration predisposes to atrial fibrillation (AF), ischemic stroke, and heart failure. Studies suggest the presence of gender differences in atrial myocardial degeneration. This study aimed to delineate gender differences in the prevalence, predictors, and prognostic impact of left atrial low-voltage areas (LVAs). This observational study included 1,488 consecutive patients who underwent initial ablation for AF. Voltage mapping was performed after pulmonary vein isolation during sinus rhythm. LVAs were defined as regions where bipolar peak-to-peak voltage was <0.50 mV. LVA prevalence was higher in women (38.7%) than in men (16.0%). High age, persistent form of AF, diabetes mellitus, and a large left atrium were shown to be common predictors in both gender categories. Heart failure and history of stroke/thromboembolic events were men-specific predictors of LVA existence. Women experienced more AF recurrence than men (31.1% vs 25.7%, p = 0.027). LVA existence was significantly associated with increased AF recurrence in each gender category, with a respective hazard ratio, 95% confidence interval, and p value of 2.45, 1.87 to 3.22, and <0.0001 in men and 1.82, 1.33 to 2.49, and <0.0001 in women. In conclusion, LVA was more frequent in women than men, and predicted frequent AF recurrence irrespective of gender category.


Assuntos
Fibrilação Atrial , Cardiomiopatias , Ablação por Cateter , Insuficiência Cardíaca , Veias Pulmonares , Masculino , Humanos , Feminino , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Fatores Sexuais , Átrios do Coração , Fibrose , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...