Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Cardiovasc Intervent Radiol ; 31(2): 281-8, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18026792

RESUMO

The purpose of this study was to assess the usefulness of a three-dimensional (3D) angiography system using a flat panel detector of direct conversion type in treatments with subsegmental transcatheter arterial chemoembolization (TACE) for hepatocellular carcinomas (HCCs). Thirty-six consecutive patients who underwent hepatic angiography were prospectively examined. First, two radiologists evaluated the degree of visualization of the peripheral branches of the hepatic arteries on 3D digital subtraction angiography (DSA). Then the radiologists evaluated the visualization of tumor staining and feeding arteries in 25 patients (30 HCCs) who underwent subsegmental TACE. The two radiologists who performed the TACE assessed whether the additional information provided by 3D DSA was useful for treatments. In 34 (94.4%) of 36 patients, the subsegmental branches of the hepatic arteries were sufficiently visualized. The feeding arteries of HCCs were sufficiently visualized in 28 (93%) of 30 HCCs, whereas tumor stains were sufficiently visualized in 18 (60%). Maximum intensity projection images were significantly superior to volume recording images for visualization of the tumor staining and feeding arteries of HCCs. In 27 (90%) of 30 HCCs, 3D DSA provided additional useful information for subsegmental TACE. The high-quality 3D DSA with flat panel detector angiography system provided a precise vascular road map, which was useful for performing subsegmental TACE of HCCs.


Assuntos
Angiografia/métodos , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/terapia , Quimioembolização Terapêutica/métodos , Imageamento Tridimensional , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/terapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia Digital , Artefatos , Criança , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Intensificação de Imagem Radiográfica/instrumentação , Interpretação de Imagem Radiográfica Assistida por Computador , Estatísticas não Paramétricas , Resultado do Tratamento
2.
AJR Am J Roentgenol ; 187(5): 1253-9, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17056913

RESUMO

OBJECTIVE: Our purpose was to compare reviewing time and diagnostic accuracy in the interpretation of radiographs without and with subtraction images and to examine whether this temporal subtraction technique can contribute to improving radiologists' performance. MATERIALS AND METHODS: Thirty cases with newly developed chest abnormalities on chest radiographs and 90 negative cases were selected. All chest radiographs were obtained with a computed radiography system. For the 90 negative cases, subtraction images were classified into two groups: 33 clean images without misregistration artifacts and 57 images with some misregistration artifacts. Eight radiologists (four board-certified radiologists and four radiology residents) participated in observer tests and interpreted the original radiographs without and with subtraction images using an independent test method. The reviewing time for each radiologist was recorded in each case. The observers' performance was evaluated by use of receiver operating characteristic (ROC) analysis. RESULTS: When subtraction images were available, the mean reviewing time per case was reduced significantly from 13.6 to 10.8 seconds for the cases with newly developed abnormalities (p < 0.001) and from 29.8 to 14.1 seconds for negative cases (p < 0.001). The reduction in the mean reviewing time with subtraction images was greater for clean images than for images with artifacts (17.7 vs 14.5 seconds, p < 0.001). The average mean area under the ROC curve value increased significantly from 0.942 without subtraction images to 0.988 with subtraction images (p = 0.025). There were significant differences in the sensitivity (0.963 with and 0.888 without the subtraction images) and the specificity (0.976 with and 0.899 without the subtraction images) (p < 0.001). CONCLUSION: The temporal subtraction technique can reduce reviewing time and also improve diagnostic accuracy in the interpretation of chest radiographs.


Assuntos
Pneumopatias/diagnóstico por imagem , Radiografia Torácica , Técnica de Subtração , Ácido Etidrônico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Intensificação de Imagem Radiográfica , Interpretação de Imagem Radiográfica Assistida por Computador
3.
Eur Radiol ; 16(11): 2594-602, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-16708219

RESUMO

The purpose of this study was to compare the image quality of two-dimensional (2D) digital subtraction angiography (DSA) between a flat panel detector (FPD) of the direct conversion type with low radiation dose and a conventional image intensifier (I.I.)-TV system, and to assess 3D DSA with the FPD system in the depiction of intracranial vessels. Fifteen consecutive patients (five men, ten women; age range: 18-82 years; mean age: 55.5 years) were prospectively included in this study. All patients underwent 2D DSA with both the FPD and I.I.-TV system in one projection. The radiation doses during angiography were evaluated using a phantom. The 3D DSA images were created from the rotational DSA data with the FPD system. Two blinded radiologists independently evaluated 2D DSA with the FPD system and I.I.-TV system using a 5-point assessment scale (excellent to not visible) to assess the depiction of intracranial vessels. MIP and volume rendering (VR) images of 3D DSA with the FPD system were also evaluated using a 5-point scale (excellent to not visible). DSA and fluoroscopy dose measurements with the phantom showed a dose reduction of approximately 85% and 9% with the FPD system compared with the I.I.-TV system, respectively. For 2D DSA, the FPD system was significantly superior to the I.I.-TV system with respect to the visibility of the peripheral and perforating vessels (p<0.05). The peripheral and perforating vessels were also sufficiently visualized on MIP images of 3D DSA in all 15 cases. Our FPD system was found to be superior to the I.I.-TV system in visualizing small intracranial vessels combined with a significant reduction of radiation dose, and was able to create high-quality 3D DSA images on which high spatial resolution allowed precise visualization of small vessels such as perforating ones.


Assuntos
Angiografia Digital , Encefalopatias/diagnóstico por imagem , Encefalopatias/patologia , Angiografia Cerebral , Processamento de Imagem Assistida por Computador , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Aneurisma Roto/diagnóstico por imagem , Aneurisma Roto/patologia , Angiografia Digital/métodos , Artéria Carótida Interna/diagnóstico por imagem , Artéria Carótida Interna/patologia , Angiografia Cerebral/métodos , Doenças Arteriais Cerebrais/diagnóstico por imagem , Doenças Arteriais Cerebrais/patologia , Simulação por Computador , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/patologia , Masculino , Meningioma/diagnóstico por imagem , Meningioma/patologia , Pessoa de Meia-Idade , Variações Dependentes do Observador , Imagens de Fantasmas , Estudos Prospectivos , Doses de Radiação , Projetos de Pesquisa , Estatísticas não Paramétricas , Hemorragia Subaracnóidea/diagnóstico por imagem , Hemorragia Subaracnóidea/patologia , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Neoplasias da Glândula Tireoide/patologia
5.
Artigo em Japonês | MEDLINE | ID: mdl-14515743

RESUMO

Nicotine is known to improve cognitive performance such as attention, concentration and working memory in humans and animals. Previous research suggests that nicotine enhances visuospatial attention. But it could be hypothesized that nicotine intake alleviate a withdrawal-induced deficit in smokers. To evaluate the cognitive performance in smokers and never-smokers, we investigate eye movement while 4-points saccade task is performed. 5 smokers and 6 never-smokers are matched for age and education. Eye movement was investigated by using TKK2920 (Takei Co.) which determines the direction of gaze over a two-dimensional visual field without attachments to the eye. We found that a tendency which Mean Gazing Time is prolonged in smokers. These data suggest that impairment of visual attention in smokers is not significant.


Assuntos
Atenção , Fumar , Tabagismo/psicologia , Percepção Visual , Adulto , Movimentos Oculares , Humanos , Fumar/efeitos adversos , Percepção Espacial
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...