1.
Int J Cardiol ; 301: 50-55, 2020 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-31759686

RESUMO

OBJECTIVES: Long-term data from randomized studies on polymer-free stents are scarce. Long-term data of Cre8 amphilimus eluting stent are still not available. We sought to investigate contribution of a polymer-free design versus a permanent-polymer one on the long-term. METHODS AND RESULTS: Patients undergoing percutaneous coronary intervention for de novo lesions were randomized 1:1 to Cre8 or Taxus Liberté (323 overall, 126 Cre8). Original primary endpoint (6-month angiographic in-stent late lumen loss) already demonstrated the superiority of Cre8 vs Taxus (0.14 + 0.36 mm vs. 0.34 + 0.40 mm; p < 0.001). Secondary endpoints were the device oriented composite endpoint (DOCE), patient oriented composite endpoint (POCE) up to 5-year. Long-term follow-up data confirmed the superiority shown by Cre8 in the analysis of the angiographic endpoint at 6-month, especially in the diabetic patients, where the device strongly reduced the clinical difference with non-diabetic. Landmark analysis demonstrated that the incidence of DOCE after 1-year and up to 5-year follow up was significantly lower in patients implanted with Cre8 AES (2.1% Cre8 vs. 9.3% Taxus, p = 0.009). While no differences were found in terms of DOCE rate among diabetic and non-diabetic patients treated with the Cre8 AES (HR 1.039; 95%CI 0.320-3.374), this was not true for Taxus (HR 2.64; 95%CI 1.112-6.278). CONCLUSIONS: Cre8 showed favourable safety and efficacy results versus Taxus at 5-years follow-up, with a superior clinical performance for the DOCE endpoint from 1 to 5 years. Cre8, differently from Taxus, has been able to strongly reduce the differences in clinical outcome between diabetic and non-diabetic up to 5 years, suggesting the higher efficacy of Cre8 in the treatment of diabetic patients.


Assuntos
Doença da Artéria Coronariana , Vasos Coronários , Paclitaxel/farmacologia , Intervenção Coronária Percutânea/instrumentação , Sirolimo/farmacologia , Materiais Revestidos Biocompatíveis/farmacologia , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/cirurgia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Stents Farmacológicos/classificação , Ácidos Graxos/farmacologia , Feminino , Humanos , Imunossupressores/farmacologia , Efeitos Adversos de Longa Duração , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Intervenção Coronária Percutânea/estatística & dados numéricos , Polímeros/farmacologia , Desenho de Prótese , Resultado do Tratamento
2.
J Am Heart Assoc ; 8(19): e013160, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31549578

RESUMO

Background Many patients with severe aortic stenosis are referred late with advanced symptoms or inappropriately denied intervention. The objective was to investigate whether a structured communication to referring physicians (facilitated data relay) might improve the rate and timeliness of intervention. Methods and Results A prospective registry of consecutive patients with severe aortic stenosis at 23 centers in 9 European countries with transcatheter as well as surgical aortic valve replacement being available was performed. The study included a 3-month documentation of the status quo (phase A), a 6-month intervention phase (implementing facilitated data relay), and a 3-month documentation of a legacy effect (phase-B). Two thousand one hundred seventy-one patients with severe aortic stenoses were enrolled (phase A: 759; intervention: 905; phase-B: 507). Mean age was 77.9±10.0 years, and 80% were symptomatic, including 52% with severe symptoms. During phase A, intervention was planned in 464/696 (67%), 138 (20%) were assigned to watchful waiting, 8 (1%) to balloon aortic valvuloplasty, 60 (9%) were listed as not for active treatment, and in 26 (4%), no decision was made. Three hundred sixty-three of 464 (78%) patients received the planned intervention within 3 months. Timeliness of the intervention improved as shown by the higher number of aortic valve replacements performed within 3 months (59% versus 51%, P=0.002) and a significant decrease in the time to intervention (36±38 versus 30±33 days, P=0.002). Conclusions A simple, low-cost, facilitated data relay improves timeliness of treatment for patients diagnosed with severe aortic stenosis, resulting in a shorter time to transcatheter aortic valve replacement. This effect was mainly driven by a significant improvement in timeliness of intervention in transcatheter aortic valve replacement but not surgical aortic valve replacement. Clinical Trial Registration URL: https://www.clinicaltrials.gov/. Unique identifier: NCT02241447.


Assuntos
Estenose da Valva Aórtica/terapia , Valvuloplastia com Balão , Implante de Prótese de Valva Cardíaca , Papel do Profissional de Enfermagem , Encaminhamento e Consulta , Tempo para o Tratamento , Substituição da Valva Aórtica Transcateter , Conduta Expectante , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/enfermagem , Valvuloplastia com Balão/efeitos adversos , Tomada de Decisão Clínica , Estudos Transversais , Ecocardiografia , Definição da Elegibilidade , Europa (Continente) , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Seleção de Pacientes , Estudos Prospectivos , Sistema de Registros , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
3.
Heart ; 105(22): 1709-1716, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31302639

RESUMO

OBJECTIVE: Contemporary data on patients with previously undiagnosed severe aortic stenosis (AS) are scarce. We aimed to address this gap by gathering data from consecutive patients diagnosed with severe AS on echocardiography. METHODS: This was a prospective, multicentre, multinational, registry in 23 tertiary care hospitals across 9 European countries. Patients with a diagnosis of severe AS were included using echocardiography (aortic valve area (AVA) <1 cm2, indexed AVA <0.6 cm2/m2, maximum jet-velocity (Vmax) >4 m/s and/or mean transvalvular gradient >40 mm Hg). RESULTS: The 2171 participants had a mean age of 77.9 years and 48.0% were female. The mean AVA was 0.73 cm2, Vmax4.3 m/s and mean gradient 47.1 mm Hg; 62.1% had left ventricular hypertrophy and 27.3% an ejection fraction (EF) <50%. 1743 patients (80.3%) were symptomatic (shortness-of-breath 91.0%; dizziness 30.2%, chest pain 28.9%). Patients had a EuroSCORE II of 4.0; 25.3% had a creatinine clearance <50 mL/min, and 3.2% had an EF <30%. Symptomatic patients were older and had more comorbidities than asymptomatic patients. Despite European Society of Cardiology 2017 valvular heart disease guideline class I recommendation, in only 76.2% a decision was made for an intervention (transcatheter 50.4%, surgical aortic valve replacement 25.8%). In asymptomatic patients, 57.7% with a class I/IIa indication were scheduled for a procedure, while 36.3% patients without an indication had their valve replaced. CONCLUSIONS: The majority of patients with severe AS presented at an advanced disease stage. Management of severe AS remained suboptimal in a significant proportion of contemporary patients with severe AS. TRIAL REGISTRATION NUMBER: NCT02241447;Results.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/terapia , Valva Aórtica/diagnóstico por imagem , Ecocardiografia , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/fisiopatologia , Doenças Assintomáticas , Comorbidade , Estudos Transversais , Europa (Continente) , Feminino , Hemodinâmica , Humanos , Masculino , Valor Preditivo dos Testes , Prognóstico , Estudos Prospectivos , Sistema de Registros , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Função Ventricular Esquerda
4.
Catheter Cardiovasc Interv ; 92(6): 1021-1027, 2018 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-29508518

RESUMO

OBJECTIVES: To date, experience with bioresorbable scaffolds (BRS) that elute agents other than everolimus is limited. Thus, a post-marketing clinical follow-up study was conducted to evaluate the continued safety and effectiveness of the DESolve® NOVOLIMUS™ Eluting BRS as treatment for patients with stable coronary artery disease. BACKGROUND: The DESolve BRS combines a poly-l-lactide-based backbone with a biodegradable polylactide-based polymer and Novolimus, a macrocyclic lactone mTOR inhibitor. METHODS: One hundred and two patients (mean age 62 years, 77.5% male) were enrolled at 10 European sites. Comparison of baseline and post-procedural angiographic assessment was performed, and a device-oriented composite endpoint (comprising cardiac death, target vessel myocardial infarction, and clinically driven target lesion revascularization) and rate of scaffold thrombosis at 12 months were examined. RESULTS: The device was successfully delivered and deployed in 98.2% (107/109) of the lesions, with two failures to cross the lesion. A total of 100 patients (109 lesions) were treated with a DESolve BRS. Post-procedural angiographic assessment indicated an in-scaffold acute gain of 1.54 ± 0.44 mm, with a reduction in % diameter stenosis from 61.00 ± 11.29 to 12.69 ± 0.44. At 12 months, the device-oriented composite endpoint had occurred in 3.0% (3/100) of patients, with 1.0% (1/100) experiencing scaffold thrombosis and myocardial infarction and 3.0% (3/100) undergoing target lesion revascularization. There were no cardiac deaths. CONCLUSIONS: Results through 12 months indicate that the DESolve BRS is a safe and effective treatment for coronary lesions, though larger, long-term prospective studies are needed.


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/cirurgia , Macrolídeos/administração & dosagem , Intervenção Coronária Percutânea/instrumentação , Adulto , Idoso , Idoso de 80 Anos ou mais , Fármacos Cardiovasculares/efeitos adversos , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Trombose Coronária/etiologia , Feminino , Alemanha , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Vigilância de Produtos Comercializados , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
6.
J Geriatr Cardiol ; 15(1): 86-94, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29434630

RESUMO

The transcatheter aortic valve implantation (TAVI) consist an alternative treatment in patients with severe aortic stenosis. Multimodality imaging using transthoracic echocardiography (TTE) or transesophageal echocardiography (TOE) and multislice CT (MSCT) constitute cornerstone techniques for the pre-operative management, peri-procedural guidance, follow up and recognition of possible transcatheter valve related complications. CT angiography is much more accurate regarding the total definition of aortic annulus diameter and circumferential area. Two-dimensional (2D) echocardiography, underestimates the aortic valve annulus diameter compared to 3D imaging techniques (MSCT, MRI and 3D TOE). Three-dimensional TOE imaging provides measurements of the aortic valve annulus similar to those delivered by MSCT. The pre-procedural MSCT constitutes the gold standard modality minimizing the presence of paravalvular aortic regurgitation, one of the most frequent complications. TOE/TTE and MSCT performance could predict the possibility of pacemaker implantation post-procedural. The presence of a new transient or persisting MR can be assessed well by TOE. Both TTE and TOE, consist initially the basic examination for post TAVI evaluation. In case of transcatheter heart valve failure, the MSCT could be used as additional imaging technique.

10.
Am J Cardiol ; 117(5): 834-8, 2016 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-26742472

RESUMO

X-ray radiation exposure is of great concern for patients undergoing structural heart interventions. In addition, a larger group of medical staff is required and exposed to radiation compared with percutaneous coronary interventions. This study aimed at quantifying radiation dose reduction with implementation of specific image noise reduction technology (NRT) in transcatheter aortic valve implantation (TAVI) procedures. We retrospectively analyzed 104 consecutive patients with TAVI procedures, 52 patients before and 52 after optimization of x-ray radiation chain, and implementation of NRT. Patients with 1-step TAVI and complex coronary intervention, or complex TAVI procedures, were excluded. Before the procedure, all patients received a multislice computed tomography scan, which was used to size aortic annulus, select the optimal implantation plane, valve type and size, and guide valve implantation using a software tool. Air kerma and kerma-area product were compared in both groups to determine patient radiation dose reduction. Baseline parameters, co-morbidity, or procedural data were comparable between groups. Mean kerma-area product was significantly lower (p <0.001) in the NRT group compared with the standard group (60 ± 39 vs 203 ± 106 Gy × cm(2), p <0.001), which corresponds to a reduction of 70%. Mean air kerma was reduced by 64% (494 ± 360 vs 1,355 ± 657 mGy, p <0.001). In conclusion, using optimized x-ray chain combined with specific image noise reduction technology has the potential to significantly reduce by 2/3 radiation dose in standard TAVI procedures without worsening image quality or prolonging procedure time.


Assuntos
Estenose da Valva Aórtica/cirurgia , Fluoroscopia/efeitos adversos , Tomografia Computadorizada Multidetectores/métodos , Lesões por Radiação/prevenção & controle , Cirurgia Assistida por Computador/métodos , Substituição da Valva Aórtica Transcateter/métodos , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Relação Dose-Resposta à Radiação , Feminino , Fluoroscopia/métodos , Seguimentos , Alemanha/epidemiologia , Humanos , Incidência , Período Intraoperatório , Masculino , Tomografia Computadorizada Multidetectores/efeitos adversos , Prognóstico , Lesões por Radiação/epidemiologia , Lesões por Radiação/etiologia , Estudos Retrospectivos , Cirurgia Assistida por Computador/efeitos adversos
11.
JACC Cardiovasc Interv ; 9(1): 51-64, 2016 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-26762911

RESUMO

OBJECTIVES: The purpose of this study was to evaluate the efficacy and long-term outcomes of a novel polymer/carrier-free drug-coated stent (DCS) in patients with de novo coronary lesions. BACKGROUND: The BioFreedom (BFD) DCS incorporates a low-profile, stainless-steel platform, with a surface that has been modified to create a selectively microstructured abluminal surface that allows adhesion and further release of Biolimus A9 (Biosensors Europe SA, Morges, Switzerland). METHODS: A total of 182 patients (183 lesions) were randomized into a 1:1:1 ratio for treatment with BFD "standard dose" (BFD) or BFD "low dose" (BFD-LD) versus first-generation paclitaxel-eluting stents (PES) at 4 sites in Germany. RESULTS: Baseline and procedural characteristics were well matched. At 4-month angiographic follow-up (Cohort 1, n = 75), in-stent late lumen loss (LLL) was significantly lower with BFD and BFD-LD versus PES (0.08 and 0.12 mm vs. 0.37 mm, respectively; p < 0.0001 for BFD vs. PES, and p = 0.002 for BFD-LD vs. PES). At 12 months (Cohort 2, n = 107), in-stent LLL (primary endpoint) was 0.17 mm in BFD versus 0.35 mm in PES (p = 0.001 for noninferiority; p = 0.11 for superiority); however, the BFD-LD (0.22 mm) did not reach noninferiority (p = 0.21). At 5 years (175 of 182), there were no significant differences in major adverse cardiac events (23.8%, 26.4%, and 20.3%) and clinically indicated target lesion revascularization (10.8%, 13.4%, and 10.2%) for BFD, BFD-LD, and PES, respectively; also, there was no definite/probable stent thrombosis reported. CONCLUSIONS: The BFD, but not the BFD-LD, demonstrated noninferiority versus PES in terms of in-stent LLL, a surrogate of neointimal hyperplasia, at 12-month follow-up. At 5 years, clinical event rates were similar, without occurrence of stent thrombosis in all groups. (BioFreedom FIM Clinical Trial; NCT01172119).


Assuntos
Fármacos Cardiovasculares/administração & dosagem , Angiografia Coronária , Doença da Artéria Coronariana/tratamento farmacológico , Vasos Coronários/efeitos dos fármacos , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Sirolimo/análogos & derivados , Idoso , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Vasos Coronários/diagnóstico por imagem , Feminino , Alemanha , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Neointima , Paclitaxel/administração & dosagem , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Valor Preditivo dos Testes , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Método Simples-Cego , Sirolimo/administração & dosagem , Aço Inoxidável , Propriedades de Superfície , Fatores de Tempo , Resultado do Tratamento
12.
JACC Cardiovasc Interv ; 9(1): 68-75, 2016 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-26762913

RESUMO

OBJECTIVES: The aim of this study was to assess the 1-year outcome after transcatheter aortic valve replacement (TAVR) of the Direct Flow Medical (DFM) valve in patients with severe symptomatic aortic stenosis who were contraindicated or high risk for surgery. BACKGROUND: The DFM transcatheter heart valve is a new-generation, nonmetallic aortic valve with a pressurized support structure and conformable double-ring annular sealing delivered through an 18-F sheath. The device allows repositioning, retrieval, and assessment of valve performance before permanent implantation. METHODS: A prospective multicenter European registry was set up to determine the safety and performance of the valve in 100 consecutive patients (10 centers). Echocardiographic and angiographic data were evaluated by an independent core laboratory, and adverse events were adjudicated by a clinical events committee using Valve Academic Research Consortium criteria. RESULTS: Patients were 83.1 ± 5.9 years of age and had a logistic EuroSCORE of 22.5 ± 11.3% and a Society of Thoracic Surgeons score of 9.7 ± 8.7%. Correct valve positioning was obtained in 99% of cases with a combined 30-day safety endpoint at 10%, including major stroke in 5.0%, major vascular complications in 2.0%, and death in 1%. At 12 months, 95% of patients were in New York Heart Association functional class I or II. Freedom from any death was 90%, and freedom from any death or major stroke was 85%. Echocardiography demonstrated none/trace to mild aortic regurgitation in 100% of patients and an unchanged mean aortic gradient of 12.2 ± 6.6 mm Hg and effective orifice area of 1.6 ± 0.4 cm(2). CONCLUSIONS: At 1 year, the DFM transcatheter heart valve had durable hemodynamics. This study demonstrates that the low rate of early complications and the low risk of significant aortic regurgitation translated into midterm clinical benefit.


Assuntos
Estenose da Valva Aórtica/terapia , Valva Aórtica/fisiopatologia , Bioprótese , Cateterismo Cardíaco/instrumentação , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Hemodinâmica , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Intervalo Livre de Doença , Europa (Continente) , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Estimativa de Kaplan-Meier , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Radiografia , Sistema de Registros , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Acidente Vascular Cerebral/etiologia , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia
13.
Catheter Cardiovasc Interv ; 88(6): E183-E190, 2016 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-26700547

RESUMO

INTRODUCTION: Years after mitral valve surgery, progressive degeneration of reconstructed mitral valves or bioprostheses might lead to severe mitral valve regurgitation. Patients with significant comorbidity, or impaired left ventricular function are poor candidates for redo surgery at an acceptable risk at that later time point. METHODS AND RESULTS: This study reports the first-in-man transapical valve-in-ring implantations in the mitral position of the fully repositionable Lotus valve system approved for transcatheter aortic valve replacement in Europe. Transapical valve-in-ring implantations with this valve system were successfully performed in a 64-year-old female, and a 53-year-old male patient. Both patients were NHYA class IV, and carried an unacceptably high risk of cardiac surgery due to clinical condition and comorbidity. The first patient was successfully implanted a 25 mm valve, improved to NYHA class II, and was discharged 2 weeks after the procedure. The second patient required a short episode of cardiopulmonary resuscitation after valve implantation (27 mm), and was placed on veno-venous ECMO for 24 hr to improve oxygenation. He developed stroke on day 7, and deceased from fatal, toxic rhabdomyolysis 13 days after the procedure. CONCLUSION: Transapical valve-in-ring implantation of the repositionable Lotus valve system in the mitral position is a feasible and promising option that merits further evaluation. © 2015 Wiley Periodicals, Inc.


Assuntos
Bioprótese , Cateterismo Cardíaco/métodos , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Ecocardiografia Transesofagiana , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/diagnóstico , Desenho de Prótese
14.
JACC cardiovasc. interv ; 9(1): 51-64, 2016.
Artigo em Inglês | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1064068

RESUMO

OBJECTIVES: The purpose of this study was to evaluate the efficacy and long-term outcomes of a novel polymer/carrier-free drug-coated stent (DCS) in patients with de novo coronary lesions.BACKGROUND: The BioFreedom (BFD) DCS incorporates a low-profile, stainless-steel platform, with a surface that has been modified to create a selectively microstructured abluminal surface that allows adhesion and further release of Biolimus A9 (Biosensors Europe SA, Morges, Switzerland). METHODS: A total of 182 patients (183 lesions) were randomized into a 1:1:1 ratio for treatment with BFD "standard dose" (BFD) or BFD "low dose" (BFD-LD) versus first-generation paclitaxel-eluting stents (PES) at 4 sites in Germany.RESULTS: Baseline and procedural characteristics were well matched. At 4-month angiographic follow-up (Cohort 1, n = 75), in-stent late lumen loss (LLL) was significantly lower with BFD and BFD-LD versus PES (0.08 and 0.12 mm vs. 0.37 mm, respectively; p < 0.0001 for BFD vs. PES, and p = 0.002 for BFD-LD vs. PES). At 12 months (Cohort 2, n = 107), in-stent LLL (primary endpoint) was 0.17 mm in BFD versus 0.35 mm in PES (p = 0.001 for noninferiority; p = 0.11 for superiority)...


Assuntos
Doença das Coronárias , Intervenção Coronária Percutânea , Stents , Stents Farmacológicos
15.
EuroIntervention ; 11(6): 698-704, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25631370

RESUMO

AIMS: In patients undergoing transcatheter aortic valve implantation (TAVI), the high prevalence of peripheral artery disease (PAD) limits femoral access and increases vascular complications that are associated with mortality and morbidity. Our study assessed the ability of a balloon-expandable large-bore vascular sheath to increase access-site availability and to reduce vascular complications. METHODS AND RESULTS: Among 257 patients from two centres, 43 patients underwent transfemoral TAVI with the use of the SoloPath balloon-expandable sheath due to complex iliofemoral access anatomy. Propensity score matching (2:1) was performed except for the sheath to femoral artery ratio (SFAR). Compared to standard sheath patients, we found no significant difference in 30-day and one-year mortality (SoloPath vs. standard sheath, 9.3% vs. 3.5%; p=0.2, and 18.6% vs. 23.3%; p=0.7), major vascular complications (9.3% vs. 4.7%; p=0.3), and major bleeding (9.3% vs. 10.5%; p=0.5) in the cohort with the balloon-expandable sheath. CONCLUSIONS: The use of a balloon-expandable large-bore sheath in patients with a high risk for vascular complications due to complex access-site anatomy proved to be feasible and safe. However, circumferential calcifications and sheath-to-artery ratios account for vascular access complications even in patients treated with the balloon-expandable sheath.


Assuntos
Valva Aórtica , Cateterismo Cardíaco/métodos , Cateterismo Periférico/instrumentação , Artéria Femoral , Doenças das Valvas Cardíacas/terapia , Implante de Prótese de Valva Cardíaca/métodos , Doença Arterial Periférica/complicações , Dispositivos de Acesso Vascular , Calcificação Vascular/complicações , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/mortalidade , Distribuição de Qui-Quadrado , Desenho de Equipamento , Feminino , Alemanha , Doenças das Valvas Cardíacas/complicações , Doenças das Valvas Cardíacas/diagnóstico , Doenças das Valvas Cardíacas/mortalidade , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Estimativa de Kaplan-Meier , Modelos Logísticos , Masculino , Doença Arterial Periférica/diagnóstico , Doença Arterial Periférica/mortalidade , Pontuação de Propensão , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Calcificação Vascular/diagnóstico , Calcificação Vascular/mortalidade
16.
Am J Cardiol ; 115(3): 360-6, 2015 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-25498539

RESUMO

To date only sparse data are available on trends and changes in indications, patient's characteristics, and clinical outcome of patients undergoing carotid artery stenting (CAS) in clinical practice. From February 1996 to December 2010, 6,116 CAS procedures were performed in 5,976 patients at 36 hospitals within the prospective, multicenter CAS registry of the Arbeitsgemeinschaft Leitende Kardiologische Krankenhausärzte. Median age of patients was 71 years, 71.6% were men; a symptomatic stenosis was treated in 50.3% and an embolic protection device (EPD) was used in 82.5% of the patients. The overall hospital mortality or stroke rate was 3.1%. Stroke or in-hospital death occurred in 4.0% in symptomatic patients and in 2.2% in asymptomatic patients. In a logistic regression model, independent predictors of in-hospital death or stroke were heart failure (odds ratio [OR] 2.03, 95% confidence interval [CI] 1.22 to 3.36, p = 0.006), symptomatic stenosis (OR 1.52, 95% CI 1.05 to 2.18, p = 0.03), and age (OR per 10 years 1.46, 95% CI 1.17 to 1.81, p <0.001). The use of an EPD was significantly associated with a lower rate of death or stroke in the registry (OR 0.45, 95% CI 0.26 to 0.78, p = 0.004). From 1996 to 2010, mean age of patients increased by 4.1 years (p <0.001), the proportion of male patients decreased from 82.4% to 70.2% (p = 0.07), the proportion of symptomatic stenoses decreased (84.6% to 24.7%, p <0.001), and the use of EPDs increased from 1.4% to 97.2% (p <0.001). Comparing 2 periods from 1996 to 2003 and 2004 to 2010, a numeric decrease in the in-hospital stroke or death rate was seen in symptomatic (4.7% vs 3.5%, p = 0.11), and in asymptomatic patients (2.9% vs 2.1%, p = 0.27) undergoing CAS, which did not reach statistical significance. In conclusion, the proportion of symptomatic carotid artery stenoses decreased significantly; EPDs established as a standard tool and a numeric decrease of in-hospital stroke or death was seen in asymptomatic and symptomatic patients undergoing CAS in clinical practice over the last 15 years.


Assuntos
Angioplastia/métodos , Implante de Prótese Vascular/métodos , Doenças das Artérias Carótidas/terapia , Dispositivos de Proteção Embólica/estatística & dados numéricos , Complicações Pós-Operatórias , Sistema de Registros , Stents , Acidente Vascular Cerebral , Fatores Etários , Idoso , Doenças Assintomáticas , Feminino , Insuficiência Cardíaca , Mortalidade Hospitalar , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
17.
Catheter Cardiovasc Interv ; 84(5): 734-41, 2014 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-24948549

RESUMO

BACKGROUND: The Cappella Sideguard (CS) sidebranch stent is a self-expanding, thin-strut, nitinol device with anatomic flaring at the sidebranch ostium designed to treat bifurcation lesions. OBJECTIVE: To evaluate the mechanism of long-term lumen patency of the novel, self-expanding CS sidebranch stent compared with a balloon-expandable stent in the main vessel. METHODS: We performed intravascular ultrasound postintervention and at follow-up in 24 CS stents and in 28 balloon-expandable drug-eluting stents deployed in the corresponding main vessel. Thirteen patients also had optical coherence tomography (OCT) at follow-up to evaluate neointimal hyperplasia and strut coverage. RESULTS: CS stent area at the sidebranch carina increased significantly from 3.8 ± 1.2 mm(2) postintervention to 4.6 ± 1.2 mm(2) at follow-up (P < 0.001), resulting in no change in lumen area (3.8 ± 1.2 mm(2) to 3.7 ± 1.2 mm(2) , P = 0.72) despite a neointimal area at follow-up of 0.9 ± 0.8 mm(2) . Volumetric changes were similar, and the distribution of neointimal hyperplasia peaked 1-2 mm distal to the carina. Change of lumen volume inversely correlated to the neointimal volume (R = -0.48, P < 0.001), but correlated positively to the change in stent volume (R = 0.52, P < 0.0001). By OCT, most CS struts were covered (100% [98.9, 100]) at the bifurcation site, whereas 61% of floating DES struts that crossed the sidebranch were covered by smooth tissue with a similar texture compared with neointima. CONCLUSION: Although neointimal hyperplasia accumulates within the CS stent mainly 1-2 mm distal to the carina, the self-expanding CS stent may be effective in maintaining an adequate patency in the sidebranch by continued stent expansion noted at follow-up.


Assuntos
Estenose Coronária/terapia , Stents Farmacológicos , Tomografia de Coerência Óptica , Ultrassonografia de Intervenção , Grau de Desobstrução Vascular/fisiologia , Idoso , Ligas , Análise de Variância , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/métodos , Distribuição de Qui-Quadrado , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Desenho de Equipamento , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica/métodos , Neointima/patologia , Neointima/fisiopatologia , Maleabilidade , Estudos Prospectivos , Desenho de Prótese , Estatísticas não Paramétricas
18.
Clin Res Cardiol ; 103(5): 373-80, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24435358

RESUMO

BACKGROUND: Drug-eluting stents (DES) reduce the rate of in-stent restenosis (ISR) and target vessel revascularization significantly when compared with bare metal stents (BMS). Their beneficial effects have been demonstrated in patients with acute myocardial infarction also, but the use of DES in the latter population seems to be still limited in clinical practice. METHODS AND RESULTS: From January 2006 to December 2011, 25,424 patients with ST-elevation myocardial infarction were enrolled in the German ALKK PCI-registry. In 5,467 patients (21.5 %), a DES was implanted in the culprit segment, in 16,911 patients (66.5 %) a BMS, and 2,959 patients (11.6 %) received neither DES nor BMS. The rates of DES for typical subgroups were 31.7 % in patients with diabetes, 36.6 % in unprotected left main stenosis, 32.4 % in ostial lesions, 32.0 % for a stent length >15 mm, 26.2 % for a stent diameter ≤3 mm, and 58.5 % for ISR. There was a wide range in the use of DES between the different ALKK hospitals with a minimum of 2.3 % and a maximum of 58.3 % for the total study period (median 22.0 %, quartiles 14.6 and 37.5 %). CONCLUSIONS: Despite convincing data for the use of DES in patients with STEMI, there is still an underuse of DES in this clinical setting in Germany. This is particularly worrying for the subgroups of patients and lesions with a high risk of restenosis. Further efforts are needed to reduce the skepticism about DES and to improve guideline adherent treatment.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Stents Farmacológicos , Oclusão de Enxerto Vascular/epidemiologia , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/terapia , Sistema de Registros , Idoso , Angioplastia Coronária com Balão/métodos , Angioplastia Coronária com Balão/mortalidade , Intervalos de Confiança , Angiografia Coronária/métodos , Eletrocardiografia , Feminino , Seguimentos , Alemanha , Oclusão de Enxerto Vascular/diagnóstico por imagem , Humanos , Incidência , Modelos Logísticos , Masculino , Metais , Pessoa de Meia-Idade , Infarto do Miocárdio/mortalidade , Razão de Chances , Estudos Prospectivos , Desenho de Prótese , Medição de Risco , Índice de Gravidade de Doença , Estatísticas não Paramétricas , Stents , Taxa de Sobrevida , Resultado do Tratamento
19.
Am J Cardiol ; 113(3): 518-21, 2014 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-24342758

RESUMO

Patients with bicuspid aortic valves (BAVs) are considered a relative contraindication to transcatheter aortic valve implantation (TAVI). One of the main reasons is the presumed risk for residual aortic regurgitation (AR). However, case reports and small case series have suggested that TAVI can be successfully performed with acceptable clinical outcomes in high-risk patients with BAV. Within the large German TAVI Registry, we sought to evaluate TAVI in older high-risk patients with BAV. From January 2009 to June 2010, a total of 1,424 patients with severe aortic stenosis undergoing TAVI were prospectively enrolled into the German TAVI Registry. For the present analysis, patients with valve-in-valve procedures were excluded and those with BAV (n = 38, 3%) were compared with those with tricuspid aortic valve (TAV; n = 1357, 97%). Patient characteristics did not markedly differ and procedural success was very high in both groups. There was a higher rate of relevant AR (≥II) after TAVI among patients with BAV (25 vs 15%, p = 0.05), whereas pacemakers were more often implanted in patients with TAV (17% vs 35%, p = 0.02). Thirty-day mortality rate was similar in both cohorts (11% vs 11%). In a Cox proportional regression analysis, BAV was not associated with higher 1-year mortality rate (hazard ratio 0.64, 95% confidence interval 0.29 to 1.41). In selected patients with BAV, TAVI can be performed with a satisfactory clinical result. Although the risk for relevant AR seems to be greater among patients with BAV, 30-day and 1-year mortality rates were not elevated compared with patients with TAV.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/anormalidades , Valva Aórtica/cirurgia , Cateterismo Cardíaco/métodos , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Sistema de Registros , Idoso de 80 Anos ou mais , Doença da Válvula Aórtica Bicúspide , Feminino , Seguimentos , Alemanha , Humanos , Tempo de Internação/tendências , Masculino , Estudos Prospectivos , Resultado do Tratamento
20.
J Am Coll Cardiol ; 63(8): 763-8, 2014 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-24211506

RESUMO

OBJECTIVES: The study sought a prospective multicenter nonrandomized evaluation of the Direct Flow Medical (DFM) system for the treatment of severe aortic stenosis. BACKGROUND: The DFM transcatheter aortic valve system is a nonmetallic design with a pressurized support structure that allows precise positioning, retrieval, and assessment of valve performance prior to permanent implantation. METHODS: One hundred high surgical risk patients with severe aortic stenosis were evaluated for the primary endpoint. There were 75 patients in the group evaluable for the secondary endpoints and 25 in the pre-specified roll-in training phase. Echocardiographic and angiographic data were evaluated by an independent core laboratory and adverse events adjudicated by clinical event committee and classified according to Valve Academic Research Consortium (VARC) criteria. RESULTS: There was 99% freedom from all cause mortality at 30 days (primary endpoint). VARC criteria defined 30 day combined freedom from patient safety event rate was 91% and overall device success was 93%. The post-implantation echocardiography results demonstrated mild or no aortic regurgitation in 99% (73 of 74) with a mean gradient of 12.6 ± 7.1 mm Hg (n = 72) and effective orifice area of 1.50 ± 0.56 cm(2) and New York Heart Association functional class was I or II in 92% of cases. CONCLUSIONS: The present study demonstrates the safety and efficacy of the DFM system in surgical high risk patients with severe aortic stenosis and complex anatomy aortic regurgitation was less than moderate in 99% of patients.


Assuntos
Estenose da Valva Aórtica/cirurgia , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Idoso , Idoso de 80 Anos ou mais , Animais , Valva Aórtica/patologia , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Cateterismo Cardíaco/instrumentação , Bovinos , Estudos de Coortes , Feminino , Seguimentos , Implante de Prótese de Valva Cardíaca/instrumentação , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos