Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eur J Trauma Emerg Surg ; 48(4): 3229-3235, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35146543

RESUMO

BACKGROUND: Tibial torsional malalignment presents a well-known complication of intramedullary nailing for tibial shaft fractures. PURPOSE: Objective of this study was to investigate the ability to clinically assess tibial torsion differences. Computed Tomography (CT) was used here as the gold standard. Further, intra- and inter-observer reliability of the clinical examination, and radiological measurements were calculated. METHODS: Fifty-one patients with torsion-difference CTs, obtained for various reasons, were asked to kneel on an examination couch with free hanging feet. All patients are positioned with 90° flexed knee and neutral ankle. A picture of the lower extremities was obtained from the back of the patient. Two blinded orthopedic surgeons were asked to look at the pictures and measure the tibial torsion with a digital goniometer, based on the axis of the femur in relation to the second ray of the foot. To determine the intra-observer variation, the torsional angles were calculated again after 4 weeks. To be able to compare values, two blinded radiologists calculated torsional differences based on computed tomography. RESULTS: All patients were able to be positioned for clinical assessment (n = 51). Clinical assessment of torsional difference revealed 4.55° ± 6.85 for the first, respectively, 4.55° ± 7.41 for the second investigator. The second measurement of the first investigator revealed a value of 4.57° ± 6.9. There was a good intra-observer agreement for clinical assessment (ICC 0.993, p < 0.001). Also, the inter-observer agreement showed a good inter-observer agreement (ICC 0.949, p < 0.001). Evaluation of radiological inter-observer assessment could also show a good inter-observer agreement (ICC 0.922, p < 0.001). The clinical method showed a good correlation to the CT method (0.839, p < 0.001). Additionally, the Bland-Altman plot was used to compare graphically both measurement techniques, which proved the agreement. CONCLUSION: In summary, computed tomography-assisted measurement of tibial torsion and clinical assessment correlated significantly good. In addition to that, clinical measurement has a good intra- and inter-observer reliability. Clinical examination is a reliable and cost-effective tool to detect mal-torsion and should be part of the repertoire of every surgeon.


Assuntos
Fraturas da Tíbia , Tomografia Computadorizada por Raios X , Fêmur/cirurgia , Humanos , Reprodutibilidade dos Testes , Tíbia/diagnóstico por imagem , Tíbia/cirurgia , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/cirurgia , Tomografia Computadorizada por Raios X/métodos , Anormalidade Torcional/diagnóstico por imagem , Anormalidade Torcional/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...