1.
J Clin Med ; 12(20)2023 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-37892749

RESUMO

BACKGROUND: We previously developed an automated total intravenous anesthesia control system that uses new closed-loop system algorithms to administer propofol, remifentanil, and rocuronium based on the bispectral index and train-of-four data. We recently improved this automated control system by adding a safety mechanism and using a modified monitoring device. METHODS: Patients scheduled for elective surgery were randomly assigned to closed-loop feedback control (automatic group) or the manual administration of propofol, remifentanil, and rocuronium (manual group). The proportion of time during which the proper management of three-agent anesthesia was maintained during surgery was determined as the primary endpoint. RESULTS: The proportion of time during which the three components of sedation, analgesia, and muscle relaxation were adequately controlled was 87.21 ± 12.79% in the automatic group, which was non-inferior to the proportion of 65.19 ± 20.16% in the manual group (p < 0.001). Adverse events during the operative or postoperative observation periods were significantly less frequent in the automatic group (54 patients, 90.0%) than in the manual group (60 patients, 100.0%; p = 0.027). CONCLUSION: Our three-agent automated control system, which features an improved muscle relaxation monitor and safety mechanism added to the basic control algorithms, maintained sedation, analgesia, and muscle relaxation appropriately in a manner non-inferior to anesthesiologists without compromising safety.

2.
JA Clin Rep ; 5(1): 42, 2019 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-32026969

RESUMO

BACKGROUND: INTELLiVENT®-ASV (iASV) is a respiration mode on the Hamilton G5. The ventilator uses a closed-loop mechanism that automatically adjusts settings related to oxygenation and ventilation. CASE PRESENTATION: A 47-year-old man underwent reconstruction surgery with free musculocutaneous flap for tongue resection. After surgery, the patient entered the ICU, and the iASV, which automatically changed only the percent minute volume (%MV) in respiration mode, was selected. On the second day, ventilator-associated pneumonia (VAP) was diagnosed, and the antibiotic treatment was changed. Using the settings of the iASV, automated FiO2 and positive end-expiratory pressure (PEEP) control were added to the ventilator mode. The patient's oxygenation was improved. CONCLUSIONS: In a patient who developed VAP after surgery, ventilation was continued using iASV, and automated changes in PEEP and FiO2 settings were successfully made according to the open lung strategy, under short-staffed circumstances.

3.
A A Case Rep ; 9(2): 54-56, 2017 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-28445174

RESUMO

There are no well-defined guidelines for obstetric and anesthetic management of pregnant patients with cerebral cavernous malformations (CMs). We need to pay careful attention to the attendant risks of both general and neuraxial anesthesia in this population. Here, we describe the anesthetic management of a pregnant woman with brainstem CMs who underwent cesarean delivery. We selected a general anesthetic technique because of concerns of undesirable effects of neuraxial anesthesia in the presence of cerebral CMs.