Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
2.
Heart ; 108(10): 794-799, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35459730

RESUMO

Cardiac implanted electronic devices are commonplace in the modern practice of cardiology. This article reviews the history of the development of these technologies, with particular reference to the role played by UK physicians and members of the British Cardiovascular Society. Key breakthroughs in the treatment of heart block, ventricular arrhythmia and heart failure are presented in their historical and contemporary context so that the reader might look back on the incredible progress and achievements of the last 100 years and also look forward to what may be achieved in the coming decades.


Assuntos
Cardiologia , Desfibriladores Implantáveis , Insuficiência Cardíaca , Marca-Passo Artificial , Arritmias Cardíacas/terapia , Estimulação Cardíaca Artificial , Insuficiência Cardíaca/terapia , Humanos
4.
Heart ; 106(20): 1579-1585, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32690621

RESUMO

OBJECTIVE: To describe the population, heart failure (HF) diagnosis rate, and 1-year hospitalisation and mortality of patients with suspected HF and elevated N-terminal pro B-type natriuretic peptide (NTproBNP) investigated according to UK National Institute for Health and Care Excellence (NICE) guidelines. METHODS: NICE recommends patients with suspected HF, based on clinical presentation and elevated NTproBNP, are referred for specialist assessment and echocardiography. Patients should be seen within 2 weeks when NTproBNP is >2000 pg/mL (2-week pathway: 2WP) or within 6 weeks when NTproBNP is 400-2000 pg/mL (6-week pathway: 6WP). This is a retrospective, multicentre, observational study of consecutive patients with suspected HF referred from primary care between 2014 and 2016 to dedicated secondary care HF clinics based on the NICE 2WP and 6WP. Data were obtained from hospital records and episode statistics. Mortality and hospitalisation rates were calculated 1 year from NTproBNP measurement. RESULTS: 1271 patients (median age 80; IQR 73-85) were assessed, 680 (53%) of whom were female. 667 (53%) were referred on the 2WP and 604 (47%) on the 6WP. 698 (55%) were diagnosed with HF (369 HF with reduced ejection fraction) and 566 (45%) as not HF (NHF). 1-year mortality was 10% (n=129) and hospitalisation was 33% (n=413). Patients on the 2WP had higher mortality and hospitalisation rates than those on the 6WP, 14% vs 6% (p<0.001) and 38% vs 27% (p<0.001), respectively. All-cause mortality (11% vs 9%; p=0.306) and hospitalisation rates (35% vs 29%; p=0.128) did not differ between HF and NHF patients, respectively. CONCLUSIONS: Outcomes using the NICE approach of short waiting time targets for specialist assessment of patients with suspected HF and raised NTproBNP are not known. The model identifies an elderly population a high proportion of whom have HF. Irrespective of diagnosis, patients have high rates of adverse outcomes. These contemporary real-world data provide a platform for discussions with patients and shaping HF services.


Assuntos
Academias e Institutos/normas , Ecocardiografia/normas , Insuficiência Cardíaca/diagnóstico , Peptídeo Natriurético Encefálico/sangue , Fragmentos de Peptídeos/sangue , Guias de Prática Clínica como Assunto/normas , Encaminhamento e Consulta/normas , Medicina Estatal/normas , Listas de Espera , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/sangue , Feminino , Insuficiência Cardíaca/sangue , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/terapia , Hospitalização , Humanos , Masculino , Valor Preditivo dos Testes , Prognóstico , Estudos Retrospectivos , Fatores de Tempo , Tempo para o Tratamento , Reino Unido , Regulação para Cima
6.
Transfus Med Hemother ; 42(6): 379-84, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26733769

RESUMO

BACKGROUND: Determination of fetal blood groups in maternal plasma samples critically depends on adequate pre-analytical steps for optimal amplification of fetal DNA. We compared the extraction of cell-free DNA by binding on a glass surface (BCSI SNAP™ Card) with an automated system based on bead technology (MagnaPure compact™). METHODS: Maternal blood samples from 281 pregnancies (7th-39th week of gestation) with known antibodies were evaluated in this study. Both the SNAP card and the MagnaPure method were applied to isolate DNA in order to directly compare the amplification in a single base extension assay and/or real-time PCR. RESULTS: The mean concentration of total DNA obtained by the SNAP card (33.8 ng/µl) exceeded more than twofold that of MagnaPure extraction (15.7 ng/µl). SNAP card-extracted samples allowed to detect 3.7 single nucleotide polymorphisms (SNPs) versus 2.5 SNPs in MagnaPure extracts to control for traces of fetal DNA. This difference is highest for samples from 7th-13th week of gestation. CONCLUSION: The SNAP card system improves DNA extraction efficacy for prenatal diagnosis in maternal blood samples and provides an at least eightfold higher total amount of DNA for the ensuing analysis. Its advantage is most evident for samples from early stages of pregnancy and thus especially valuable for pregnancies with antibodies.

7.
Chin Sci Bull ; 58(10): 1162-1168, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25477717

RESUMO

We report on the use of a novel non-instrumented platform to enable a Loop Mediated isothermal Amplification (LAMP) based assay for Salmonella enterica. Heat energy is provided by addition of a small amount (<150 g) of boiling water, and the reaction temperature is regulated by storing latent energy at the melting temperature of a lipid-based engineered phase change material. Endpoint classification of the reaction is achieved without opening the reaction tube by observing the fluorescence of sequence-specific FRET-based assimilating probes with a simple handheld fluorometer. At or above 22°C ambient temperature the non-instrumented devices could maintain reactions above a threshold temperature of 61°C for over 90 min-significantly longer than the 60 min reaction time. Using the simple format, detection limits were less than 20 genome copies for reactions run at ambient temperatures ranging from 8 to 36°C. When used with a pre-enrichment step and non-instrumented DNA extraction device, trace contaminations of Salmonella in milk close to 1 CFU/mL could be reliably detected. These findings illustrate that the non- instrumented amplification approach is a simple, viable, low-cost alternative for field-based food and agricultural diagnostics or clinical applications in developing countries.

8.
J Clin Microbiol ; 49(3): 1010-6, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21191051

RESUMO

The isolation of pure nucleic acids from clinical samples is a crucial step in the molecular diagnosis of viral infections by nucleic acid testing (NAT). In this study, novel flat glass devices (cards) were demonstrated to support the rapid and efficient extraction of nucleic acids from upper respiratory tract specimens (nasal washes and swabs). The performance of the nucleic acid extraction cards was directly compared to an existing standardized and automated platform for viral extraction from these types of specimens. The flowthrough card method improved the speed of nucleic acid purification and accommodated larger sample volumes in extraction of bacteriophage MS2 RNA from the various specimen matrices. The dynamic range and estimated sensitivity of the card extraction method for reverse transcriptase quantitative real-time PCR (RT-qPCR)-based detection approximate those of the standardized magnetic glass bead extraction method used in this study.


Assuntos
Secreções Corporais/virologia , Levivirus/isolamento & purificação , RNA Viral/isolamento & purificação , Sistema Respiratório , Virologia/métodos , Automação/métodos , Equipamentos e Provisões , Vidro , Humanos , Levivirus/genética , RNA Viral/genética , Sensibilidade e Especificidade
9.
Anal Biochem ; 365(2): 240-5, 2007 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-17442254

RESUMO

It is well known that DNA strands bind to silica surfaces in the presence of high concentrations of chaotropic salts. We developed simple methods to evaluate binding and recovery of DNA on flat glass microscope slides and compared their properties with commercially available silica "spin columns". Surprisingly, genomic DNA was recovered efficiently from untreated glass slides. Binding and elution times from glass slides were optimized in experiments with DNA samples of various sizes and defined buffers. Average DNA recovery from 500 ng of input genomic DNA varied from 25 to 53% for the glass slide protocol. Yields were comparable to those of spin columns. Human serum albumin and plasma components decreased DNA binding to glass several-fold in a concentration-dependent manner. These results support the concept of using flat glass slides as DNA purification surfaces in microfluidic devices for PCR sample preparation.


Assuntos
DNA/química , DNA/isolamento & purificação , Genoma , Vidro/química , Animais , DNA/genética , Genômica/métodos , Humanos , Masculino , Técnicas Analíticas Microfluídicas , Hibridização de Ácido Nucleico , Sondas de Oligonucleotídeos , Plasma/química , Salmão/genética , Albumina Sérica/química , Espermatozoides
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...