1.
Clin Lab ; 58(5-6): 515-25, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22783583

RESUMO

BACKGROUND: In the second generation of the point-of-care (POC) assay Roche CARDIAC proBNP, the upper limit of the measuring range was extended from 3000 to 9000 ng/L. METHODS: A thirteen-site multicentre evaluation was carried out to assess the analytical performance of the POC NT-proBNP assay and to compare it with a laboratory N-terminal pro-brain natriuretic peptide (NT-proBNP) assay. RESULTS: In method comparisons of six lots of POC NT-proBNP with the lab reference method (Elecsys proBNP) mean bias ranged from -10 to +17%. In lot-to-lot comparisons all six investigated lots of POC NT-proBNP showed excellent agreement, with mean bias between -7% and +2%. The majority of all coefficients of variation obtained from ten-fold measurements using 56 native blood samples were below 8%. No interference was observed with hemolytic blood (hemoglobin concentrations up to 0.12 mmol/L), lipemic blood (triglyceride concentrations up to 14.0 mmol/L) nor icteric blood (bilirubin concentrations up to 63 micromol/L). Hematocrit values between 24% and 51% had no influence on the assay result. High NT-proBNP concentrations above the measuring range of POC NT-proBNP did not lead to false low results due to potential high-dose hook effect. Results with POC NT-proBNP were not influenced by different ambient temperatures (18 degrees C to 32 degrees C), the sample material used, nor by over- or underdosing by 15 microL compared to the regular sample volume of 150 microL. CONCLUSIONS: The POC NT-proBNP assay showed an excellent analytical performance including a good agreement with the laboratory method. The assay is therefore suitable for its intended use in point-of-care settings.


Assuntos
Fator Natriurético Atrial/sangue , Técnicas de Diagnóstico Cardiovascular/instrumentação , Sistemas Automatizados de Assistência Junto ao Leito , Precursores de Proteínas/sangue , Técnicas de Diagnóstico Cardiovascular/normas , Humanos , Sistemas Automatizados de Assistência Junto ao Leito/normas , Controle de Qualidade , Reprodutibilidade dos Testes , Temperatura
2.
Clin Lab ; 53(7-8): 423-31, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17821946

RESUMO

A new point-of-care test for the determination of NT-proBNP in whole blood was developed based on the existing gold-label rapid immunoassay technology of the Roche Cardiac reader system. The novel gold-labelled monoclonal antibody recognizes NT-proBNP at amino acid sequence 27 to 31, the biotinylated polyclonal antibody recognizes sequence 39 to 50. In a model assay based upon the reference method Elecsys proBNP and with an R & D lot of the point-of-care test, this newly selected and developed combination of antibodies showed a very good correlation with the standard Elecsys proBNP assay with correlations of 0.96 or 0.94, respectively. The test was calibrated according to the existing masterlot concept of the Roche CARDIAC tests with Elecsys proBNP as a reference. In a preliminary method comparison with Elecsys proBNP the accuracy of the calibration was confirmed; the bias was between 1 and 6%. Possible reasons of approximately 1% outliers (> +/- 100%) were discussed.


Assuntos
Insuficiência Cardíaca/sangue , Insuficiência Cardíaca/diagnóstico , Peptídeo Natriurético Encefálico/sangue , Fragmentos de Peptídeos/sangue , Sistemas Automatizados de Assistência Junto ao Leito/normas , Kit de Reagentes para Diagnóstico , Anticorpos , Especificidade de Anticorpos , Calibragem , Humanos , Controle de Qualidade , Kit de Reagentes para Diagnóstico/normas , Reprodutibilidade dos Testes
3.
Clin Chem Lab Med ; 44(10): 1269-77, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-17032141

RESUMO

BACKGROUND: The Roche CARDIAC proBNP point-of-care (POC) test is the first test intended for the quantitative determination of N-terminal pro-brain natriuretic peptide (NT-proBNP) in whole blood as an aid in the diagnosis of suspected congestive heart failure, in the monitoring of patients with compensated left-ventricular dysfunction and in the risk stratification of patients with acute coronary syndromes. METHODS: A multicentre evaluation was carried out to assess the analytical performance of the POC NT-proBNP test at seven different sites. RESULTS: The majority of all coefficients of variation (CVs) obtained for within-series imprecision using native blood samples was below 10% for both 52 samples measured ten times and for 674 samples measured in duplicate. Using quality control material, the majority of CV values for day-to-day imprecision were below 14% for the low control level and below 13% for the high control level. In method comparisons for four lots of the POC NT-proBNP test with the laboratory reference method (Elecsys proBNP), the slope ranged from 0.93 to 1.10 and the intercept ranged from 1.8 to 6.9. The bias found between venous and arterial blood with the POC NT-proBNP method was < or =5%. All four lots of the POC NT-proBNP test investigated showed excellent agreement, with mean differences of between -5% and +4%. No significant interference was observed with lipaemic blood (triglyceride concentrations up to 6.3 mmol/L), icteric blood (bilirubin concentrations up to 582 micromol/L), haemolytic blood (haemoglobin concentrations up to 62 mg/L), biotin (up to 10 mg/L), rheumatoid factor (up to 42 IU/mL), or with 50 out of 52 standard or cardiological drugs in therapeutic concentrations. With bisoprolol and BNP, somewhat higher bias in the low NT-proBNP concentration range (<175 ng/L) was found. Haematocrit values between 28% and 58% had no influence on the test result. Interference may be caused by human anti-mouse antibodies (HAMA) types 1 and 2. No significant influence on the results with POC NT-proBNP was found using volumes of 140-165 muL. High NT-proBNP concentrations above the measuring range of the POC NT-proBNP test did not lead to false low results due to a potential high-dose hook effect. CONCLUSIONS: The POC NT-proBNP test showed good analytical performance and excellent agreement with the laboratory method. The POC NT-proBNP assay is therefore suitable in the POC setting.


Assuntos
Cardiopatias/sangue , Peptídeo Natriurético Encefálico/sangue , Fragmentos de Peptídeos/sangue , Sistemas Automatizados de Assistência Junto ao Leito/normas , Kit de Reagentes para Diagnóstico , Calibragem , Insuficiência Cardíaca/sangue , Hemoglobinas/análise , Humanos , Kit de Reagentes para Diagnóstico/normas , Valores de Referência , Reprodutibilidade dos Testes , Tamanho da Amostra , Fatores de Tempo