Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Anesthesiology ; 127(6): 918-933, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-28872484

RESUMO

BACKGROUND: Ischemic myocardial damage accompanying coronary artery bypass graft surgery remains a clinical challenge. We investigated whether xenon anesthesia could limit myocardial damage in coronary artery bypass graft surgery patients, as has been reported for animal ischemia models. METHODS: In 17 university hospitals in France, Germany, Italy, and The Netherlands, low-risk elective, on-pump coronary artery bypass graft surgery patients were randomized to receive xenon, sevoflurane, or propofol-based total intravenous anesthesia for anesthesia maintenance. The primary outcome was the cardiac troponin I concentration in the blood 24 h postsurgery. The noninferiority margin for the mean difference in cardiac troponin I release between the xenon and sevoflurane groups was less than 0.15 ng/ml. Secondary outcomes were the safety and feasibility of xenon anesthesia. RESULTS: The first patient included at each center received xenon anesthesia for practical reasons. For all other patients, anesthesia maintenance was randomized (intention-to-treat: n = 492; per-protocol/without major protocol deviation: n = 446). Median 24-h postoperative cardiac troponin I concentrations (ng/ml [interquartile range]) were 1.14 [0.76 to 2.10] with xenon, 1.30 [0.78 to 2.67] with sevoflurane, and 1.48 [0.94 to 2.78] with total intravenous anesthesia [per-protocol]). The mean difference in cardiac troponin I release between xenon and sevoflurane was -0.09 ng/ml (95% CI, -0.30 to 0.11; per-protocol: P = 0.02). Postoperative cardiac troponin I release was significantly less with xenon than with total intravenous anesthesia (intention-to-treat: P = 0.05; per-protocol: P = 0.02). Perioperative variables and postoperative outcomes were comparable across all groups, with no safety concerns. CONCLUSIONS: In postoperative cardiac troponin I release, xenon was noninferior to sevoflurane in low-risk, on-pump coronary artery bypass graft surgery patients. Only with xenon was cardiac troponin I release less than with total intravenous anesthesia. Xenon anesthesia appeared safe and feasible.


Assuntos
Anestesia Intravenosa , Ponte de Artéria Coronária/tendências , Internacionalidade , Éteres Metílicos/administração & dosagem , Troponina I/sangue , Xenônio/administração & dosagem , Idoso , Anestésicos Inalatórios/administração & dosagem , Biomarcadores/sangue , Ponte de Artéria Coronária/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/sangue , Complicações Pós-Operatórias/prevenção & controle , Estudos Prospectivos , Sevoflurano , Método Simples-Cego , Resultado do Tratamento
3.
Comput Methods Biomech Biomed Engin ; 18(12): 1358-66, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-24697250

RESUMO

A numerical pressure loss model previously used for adult human airways has been modified to simulate the inhalation pressure distribution in a healthy 9-month-old infant lung morphology model. Pressure distributions are calculated for air as well as helium and xenon mixtures with oxygen to investigate the effects of gas density and viscosity variations for this age group. The results indicate that there are significant pressure losses in infant extrathoracic airways due to inertial effects leading to much higher pressures to drive nominal flows in the infant airway model than for an adult airway model. For example, the pressure drop through the nasopharynx model of the infant is much greater than that for the nasopharynx model of the adult; that is, for the adult-versus-child the pressure differences are 0.08 cm H2O versus 0.4 cm H2O, 0.16 cm H2O versus 1.9 cm H2O and 0.4 cm H2O versus 7.7 cm H2O, breathing helium-oxygen (78/22%), nitrogen-oxygen (78/22%) and xenon-oxygen (60/40%), respectively. Within the healthy lung, viscous losses are of the same order for the three gas mixtures, so the differences in pressure distribution are relatively small.


Assuntos
Gases/química , Inalação/fisiologia , Pulmão/fisiologia , Modelos Biológicos , Pressão , Fenômenos Fisiológicos Respiratórios , Hélio , Humanos , Lactente , Pulmão/anatomia & histologia , Oxigênio , Xenônio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...