Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Clin Ultrasound ; 44(6): 347-53, 2016 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-26890486

RESUMO

PURPOSE: To evaluate the diagnostic efficacy of virtual touch tissue quantification (VTQ) and contrast-enhanced ultrasonography (CEUS), separately and in combination, in diagnosing malignant focal liver lesions (FLLs). METHODS: Forty-six patients with 55 FLLs (28 benign and 27 malignant) underwent both VTQ and CEUS. The diagnostic values of VTQ and CEUS, alone and in combination, were compared. RESULTS: The diagnostic sensitivity, specificity, accuracy, positive predictive value (PPV), and negative predictive value (NPV) of CEUS were 92.6% (25/27), 96.4% (27/28), 94.5% (52/55), 96.2% (25/26), and 93.1% (27/29), respectively. The diagnostic sensitivity, specificity, accuracy, PPV, and NPV of VTQ with a cutoff of 2.22 m/s were 51.9% (14/27), 85.7% (24/28), 69.1% (38/55), 77.8% (14/18), and 64.9% (24/37), respectively. The diagnostic sensitivity, specificity, accuracy, PPV, and NPV of VTQ and CEUS combined were 96.3% (26/27), 82.1% (23/28), 89.1% (49/55), 83.9% (26/31), and 95.8% (23/24), respectively. Comparing the accuracies of the three methods, the diagnostic values of CEUS and of the combination of CEUS with VTQ were significantly higher than those of VTQ alone (p ≤ 0.01). There was no significant difference between the combination of CEUS with VTQ and CEUS (p = 0.49). CONCLUSIONS: CEUS is superior to VTQ in diagnosing malignant FLLs. Adding VTQ to CEUS did not improve the diagnosis of FLLs. © 2016 Wiley Periodicals, Inc. J Clin Ultrasound 44:347-353, 2016.


Assuntos
Meios de Contraste , Aumento da Imagem/métodos , Processamento de Imagem Assistida por Computador/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Ultrassonografia/métodos , Diagnóstico Diferencial , Feminino , Humanos , Fígado/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
Guang Pu Xue Yu Guang Pu Fen Xi ; 24(3): 295-8, 2004 Mar.
Artigo em Chinês | MEDLINE | ID: mdl-15759979

RESUMO

The influence of calcium chloride on the crystallinity of nylon 6 was studied by means of time-resolved FTIR, WADX and DSC. The results show that the crystallinity of nylon 6 decreased with the increase of CaCl2, and finally nylon 6 changed from crystal phase to amorphous phase. Because hydrogen bond is the main reason that nylon has three-dimensional ordered structure and forms crystalline phase, we further studied the changes of wave number of NH, amide I and amide II related to hydrogen bond in CaCl2/PA6 complexes by time-resolved FTIR. These studies indicate that in the chloroethanol solution of nylon 6 and calcium chloride, complex bonds between calcium cation and oxygen atom of carbonyl group gradually form, and calcium cations are inserted into the molecular chains of nylon 6, which weaken the hydrogen bonds between the molecular chains of nylon 6 and damage the three-dimensional ordered structure of nylon 6, so the crystallinity of nylon 6 decreases and nylon 6 changes from crystalline to amorphous phase.


Assuntos
Cloreto de Cálcio/farmacologia , Caprolactama/análogos & derivados , Ligação de Hidrogênio/efeitos dos fármacos , Polímeros/química , Espectroscopia de Infravermelho com Transformada de Fourier/métodos , Caprolactama/química , Cristalização , Cristalografia por Raios X/métodos , Modelos Moleculares , Estrutura Molecular , Fatores de Tempo , Difração de Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...