Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Micromachines (Basel) ; 14(4)2023 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-37421100

RESUMO

Human body temperature is a fundamental physiological sign that reflects the state of physical health. It is important to achieve high-accuracy detection for non-contact human body temperature measurement. In this article, a Ka band (32 to 36 GHz) analog complex correlator using the integrated six-port chip is proposed, and a millimeter-wave thermometer system based on the designed correlator is completed for human body temperature measurement. The designed correlator utilizes the six-port technique to achieve large bandwidth and high sensitivity, and miniaturization of the correlator is achieved through an integrated six-port chip. By performing the single-frequency test and the broadband noise measurement on the correlator, we can determine that the dynamic range of input power of the correlator is -70 dBm to -35 dBm, and the correlation efficiency and equivalent bandwidth are 92.5% and 3.42 GHz, respectively. Moreover, the output of the correlator varies linearly with the input noise power, which reveals that the designed correlator is suitable for the field of human body temperature measurement. Then, a handheld thermometer system, with a size of 140 mm × 47 mm × 20 mm, is proposed using the designed correlator, and the measurement results show that the temperature sensitivity of the thermometer is less than 0.2 K.

2.
Sensors (Basel) ; 22(13)2022 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-35808380

RESUMO

Six-port technology has been widely used in microwave systems, such as interferometric passive imaging. In this paper, an integrated Ka-band (32-36 GHz) six-port chip based on the 0.15-µm GaAs technology is designed and fabricated to simplify the circuit structure and miniaturize the volume of the imaging system. The designed chip integrates two amplifiers, two phase shifters, and a six-port circuit as part of an analog complex correlator. In this integrated chip, the crosstalk between the two amplifiers cannot be ignored. This paper analyzes the influence of the isolation between two amplifiers on the correlation results to guide the six-port chip design. In addition, considering that the radiometer system receives a broadband noise signal, the phase shifter needs to ensure that the phase shift range of each frequency point is the same under the same control conditions. Therefore, the phase shifter is designed with a high-pass and low-pass structure. The measurement results show that the isolation between the two amplifiers is greater than 20 dB, and the measured phase shift range and phase shift range error of the designed chip are 220° and 10°, respectively, with the control voltage varying from 0 to 1.5 V, which meets the requirements of the system.

3.
Sensors (Basel) ; 21(8)2021 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-33924439

RESUMO

A non-contact heartbeat/respiratory rate monitoring system was designed using narrow beam millimeter wave radar. Equipped with a special low sidelobe and small-sized antenna lens at the front end of the receiving and transmitting antennas in the 120 GHz band of frequency-modulated continuous-wave (FMCW) system, this sensor system realizes the narrow beam control of radar, reduces the interference caused by the reflection of other objects in the measurement background, improves the signal-to-clutter ratio (SCR) of the intermediate frequency signal (IF), and reduces the complexity of the subsequent signal processing. In order to solve the problem that the accuracy of heart rate is easy to be interfered with by respiratory harmonics, an adaptive notch filter was applied to filter respiratory harmonics. Meanwhile, the heart rate obtained by fast Fourier transform (FFT) was modified by using the ratio of adjacent elements, which helped to improve the accuracy of heart rate detection. The experimental results show that when the monitoring system is 1 m away from the human body, the probability of respiratory rate detection error within ±2 times for eight volunteers can reach 90.48%, and the detection accuracy of the heart rate can reach 90.54%. Finally, short-term heart rate measurement was realized by means of improved empirical mode decomposition and fast independent component analysis algorithm.


Assuntos
Radar , Sinais Vitais , Algoritmos , Frequência Cardíaca , Humanos , Taxa Respiratória , Processamento de Sinais Assistido por Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...