Phys Eng Sci Med ; 45(2): 537-546, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35381970

RESUMO

Relative dosimetry measurements are required to fully commission kilovoltage X-ray units for superficial and orthovoltage X-ray therapy. Validation of these relative dosimetry measurements with Monte Carlo methods is advantageous being independent of the measurement process. In this study use is made of the X-ray spectrum generating program SpekPy along with the EGSnrc Monte Carlo code to calculate depth doses and explore the dosimetry effect of changes in backscatter. These calculations are compared with previously reported measurements for the Pantak SXT 150 X-ray therapy unit. SpekPy can also be used to generate half value layer (HVL) values and these are also compared to previously reported HVL measurements for the same X-ray therapy unit. It was found that agreements of the order of 5% in HVL, 3% in depth dose and 1% in backscatter doses were found between Monte Carlo calculations and the previously published measured data. Exit doses in conditions of lack of full backscatter were explored with Monte Carlo calculations demonstrating reduced exit dose up to 20% in these conditions. It is concluded that SpekPy with Monte Carlo codes such as EGSnrc provides a straightforward approach to validating various relative dosimetry measurements in kilovoltage X-ray dosimetry.


Assuntos
Terapia por Raios X , Método de Monte Carlo , Radiografia , Radiometria , Raios X
2.
Acta Oncol ; 59(5): 503-510, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-31973620

RESUMO

Background: The IAEA recommends a quality assurance program in radiotherapy to ensure safe and effective treatments. In this study, radiotherapy departments were surveyed on their current practice including the extent and depth of quality assurance activities.Methods: Radiotherapy departments were voluntarily surveyed in three stages, firstly, in basic facility information, secondly, in quality assurance activities and treatment techniques, and thirdly, in a snapshot of quality assurance, departmental and treatment activities.Results: The IAEA received completed surveys from 381 radiotherapy departments throughout the world with 100 radiotherapy departments completing all three surveys. Dominant patterns were found in linac-based radiotherapy with access to treatment planning systems for 3D-CRT and 3D imaging. Staffing levels for major staff groups were on average in the range recommended by the IAEA. The modal patient workload per EBRT unit was as expected in the range of 21-30 patients per day, however significant instances of high workload (more than 50 patients per day per treatment unit) were reported. Staffing levels were found to correlate with amount of treatment equipment and patient workload. In a self-assessment of quality assurance performance, most radiotherapy departments reported that they would perform at least 60% of the quality assurance activities itemized in the second survey, with particular strength in equipment quality control. In a snapshot survey of quality assurance performance, again equipment quality control practice was well developed, particularly for the treatment equipment.Conclusions: The IAEA surveys provide a snapshot of current radiotherapy practice including quality assurance activities.


Assuntos
Auditoria Médica/estatística & dados numéricos , Neoplasias/radioterapia , Serviço Hospitalar de Medicina Nuclear/organização & administração , Radioterapia (Especialidade)/organização & administração , Humanos , Auditoria Médica/organização & administração , Auditoria Médica/normas , Serviço Hospitalar de Medicina Nuclear/normas , Serviço Hospitalar de Medicina Nuclear/estatística & dados numéricos , Aceleradores de Partículas/normas , Radioterapia (Especialidade)/instrumentação , Radioterapia (Especialidade)/normas , Radioterapia (Especialidade)/estatística & dados numéricos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/normas , Planejamento da Radioterapia Assistida por Computador/estatística & dados numéricos , Radioterapia Conformacional/normas , Radioterapia Conformacional/estatística & dados numéricos , Inquéritos e Questionários/estatística & dados numéricos
3.
Clin Oncol (R Coll Radiol) ; 29(2): 110-115, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27908503

RESUMO

Medical linear accelerators (linacs) and cobalt-60 machines are both mature technologies for external beam radiotherapy. A comparison is made between these two technologies in terms of infrastructure and maintenance, dosimetry, shielding requirements, staffing, costs, security, patient throughput and clinical use. Infrastructure and maintenance are more demanding for linacs due to the complex electric componentry. In dosimetry, a higher beam energy, modulated dose rate and smaller focal spot size mean that it is easier to create an optimised treatment with a linac for conformal dose coverage of the tumour while sparing healthy organs at risk. In shielding, the requirements for a concrete bunker are similar for cobalt-60 machines and linacs but extra shielding and protection from neutrons are required for linacs. Staffing levels can be higher for linacs and more staff training is required for linacs. Life cycle costs are higher for linacs, especially multi-energy linacs. Security is more complex for cobalt-60 machines because of the high activity radioactive source. Patient throughput can be affected by source decay for cobalt-60 machines but poor maintenance and breakdowns can severely affect patient throughput for linacs. In clinical use, more complex treatment techniques are easier to achieve with linacs, and the availability of electron beams on high-energy linacs can be useful for certain treatments. In summary, there is no simple answer to the question of the choice of either cobalt-60 machines or linacs for radiotherapy in low- and middle-income countries. In fact a radiotherapy department with a combination of technologies, including orthovoltage X-ray units, may be an option. Local needs, conditions and resources will have to be factored into any decision on technology taking into account the characteristics of both forms of teletherapy, with the primary goal being the sustainability of the radiotherapy service over the useful lifetime of the equipment.


Assuntos
Radioterapia (Especialidade)/instrumentação , Radioterapia/instrumentação , Radioisótopos de Cobalto/uso terapêutico , Humanos , Neoplasias/radioterapia , Nêutrons , Aceleradores de Partículas , Radiometria/métodos
4.
J Med Phys ; 36(2): 107-10, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21731227

RESUMO

Quality assurance of external-beam treatment-planning systems is recommended, and this can be partly achieved with predefined type tests. The beam data and test geometries of IAEA TECDOC 1540 have been used to test the analytical anisotropic algorithm (AAA) and pencil-beam convolution (PBC) algorithm of the Varian Eclipse treatment planning system. Beam models were created in Eclipse for 6 MV, 10 MV and 18 MV from the available beam data. Twelve test geometries were re-created in Eclipse, and the differences between Eclipse dose calculations and dose measurements were recorded. The AAA algorithm generally performed better than the PBC algorithm for the 12 tests, but both algorithms did not meet predefined tolerances for asymmetric wedge fields. An in-house monitor unit check program based on collimator and phantom scatter factors with tissue-phantom ratios was also tested and its calculations were found to agree with measurements to within 3.2% for on-axis points.

5.
Australas Phys Eng Sci Med ; 31(1): 49-55, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18488964

RESUMO

Loss of backscatter has been measured for a Pantak Therapax SXT 150 superficial x-ray therapy unit. Ionisation chamber measurements at the surface were performed in solid water with and without underlying lead to confirm the applicability of previous published measurements. Measurements of loss of backscatter with and without lead allowed the effect of underlying lead to be separated from the effect of loss of backscatter. It was found that the difference between the effect of lead and that of air on surface dose is minimal for solid water phantom thickness exceeding 3 cm. Differences up to 3% in dose reduction at the surface were found between this work and previous published results with different x-ray units.


Assuntos
Radiometria/métodos , Radioterapia/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Doses de Radiação , Radioterapia/métodos , Espalhamento de Radiação
7.
Phys Med Biol ; 50(16): 3875-88, 2005 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-16077233

RESUMO

Investigation of the normoxic PAGAT polymer gel dosimeter has been undertaken. The concentrations of the chemical components of the gel were varied and its response to ionizing radiation evaluated. Using MRI, the formulation to give the maximum change in the transverse relaxation rate R2 was determined to be 4.5% N, N'-methylene-bis-acrylamide (bis), 4.5% acrylamide (AA), 5% gelatine, 5 mM tetrakis (hydroxymethyl) phosphonium chloride (THPC), 0.01 mM hydroquinone (HQ) and 86% H2O. The optimal post-manufacture irradiation and post-irradiation imaging times were both determined to be 12 h. The R2-dose response was linear up to 7 Gy with R2-dose sensitivities of (0.183 +/- 0.005) s(-1) Gy(-1), (0.182 +/- 0.005) s(-1) Gy(-1) and (0.192 +/- 0.005) s(-1) Gy(-1) when imaged at 12 h, 7 days and 24 days post-irradiation, respectively. The R2-dose sensitivities were within the range of previously published values for the hypoxic PAG formulations. For the imaging parameters used in this study the optimum dose resolution was achieved for low doses. The normalized R2 edge response showed a high degree of spatial stability over a 24 day period. This study has shown that the normoxic PAGAT polymer gel has the properties of a dosimetric tool, which can be used in clinical radiotherapy. The PAGAT polymer gel has been shown to have similar qualities to the PAG polymer gel, while offering the significant advantage of simplification of the manufacturing procedure.


Assuntos
Resinas Acrílicas/química , Imageamento por Ressonância Magnética/métodos , Compostos Organofosforados/química , Radiometria/instrumentação , Radiometria/métodos , Acrilamida/farmacologia , Acrilamidas/farmacologia , Relação Dose-Resposta à Radiação , Gelatina/farmacologia , Humanos , Processamento de Imagem Assistida por Computador , Polímeros/química , Fatores de Tempo
8.
Australas Phys Eng Sci Med ; 28(2): 115-21, 2005 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16060318

RESUMO

Output factors at the surface for treatment cones and lead cut-outs have been measured for a Pantak Therapax SXT 150 superficial therapy unit with x-ray beam qualities from 1 to 13 mm A1 HVL. A variety of phantom materials and two ionisation chambers were tested for their suitability in output factor and percentage depth dose measurement. Solid water proved a useful water-equivalent phantom material with discrepancies between measurements in water and solid water less than 2.3% for percentage depth dose and less than 0.6% for output factors. Larger measurement discrepancies were found for Plastic Water and Perspex. A PTW Markus chamber was found to compare well with a NE 2532/3 low energy chamber in percentage depth dose measurement, but discrepancies arose between the chambers in output factor measurements, up to 5% for small field sizes. Measurements indicated that the Markus chamber had an energy dependent response in the kilovoltage range, which could account for the discrepancy in output factor measurement.


Assuntos
Análise de Falha de Equipamento/métodos , Garantia da Qualidade dos Cuidados de Saúde/métodos , Radiometria/métodos , Terapia por Raios X/instrumentação , Austrália , Análise de Falha de Equipamento/normas , Guias como Assunto , Doses de Radiação , Radiometria/normas , Padrões de Referência , Terapia por Raios X/métodos
9.
Australas Phys Eng Sci Med ; 28(1): 8-13, 2005 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15920984

RESUMO

Tin foils of sub-millimetre thickness have been investigated as bolus material for therapeutic electron beams from the Varian Clinac 2100C/D linear accelerator. Measurements with ionisation chamber and radiographic film in Plastic Water or water were performed under tin foil bolus to determine surface dose, therapeutic ranges, output factor correction, penumbra and dose outside the field edge. Appropriate thicknesses of tin foil for 90% dose at the surface were found to be approximately 0.3 mm for 6 MeV, and 0.4 mm for 9 MeV and 12 MeV. Enhanced therapeutic interval with tin foil bolus over water-equivalent bolus has previously been reported, but was found not to be evident for 12 MeV and for a small (4 x 4 cm2) 9 MeV field. The penumbra width of fields with tin foil and water-equivalent bolus were found to be within 2 mm, while the doses at 1 cm outside the field edge were within 1.5% of peak dose. Output factor corrections for fields with tin foil were measured as within 2% of unity. Air gaps between the tin foil and phantom surface up to 5 mm were observed to have minimal effect on output correction factor, relative surface dose, and therapeutic range.


Assuntos
Elétrons/uso terapêutico , Radiometria/métodos , Estanho/química , Estanho/efeitos da radiação , Relação Dose-Resposta à Radiação , Aceleradores de Partículas , Dosagem Radioterapêutica , Espalhamento de Radiação , Estanho/uso terapêutico
10.
Med Phys ; 30(9): 2282-91, 2003 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-14528948

RESUMO

Glucose, sucrose, starch, and locust bean gum have been used as additives to the ferrous-agarose-xylenol orange (FAX) gel dosimeter. The saccharide enhanced dosimeters were found to have a higher dose sensitivity over a standard FAX gel as measured by both optical density change and magnetic resonance imaging (MRI). With optical density measurement, OD-dose sensitivity increases were up to 55% for glucose, 122% for sucrose and 43% for starch, while locust bean gum did not give a consistent response. With MRI, R1-dose sensitivity increases were up to 178% with sucrose addition. The FAX gel with sucrose was studied in greatest detail. The OD-dose sensitivity dependence on cooling rate was reduced for the sucrose FAX gel over the standard FAX gel, which has significant implications for uniform dose sensitivity in large gel phantoms. The thermal oxidation rate in the sucrose FAX gel was up to 2.3 times higher than in the standard gel. The OD-dose sensitivity of oxygenated sucrose FAX gels was 4.3 times greater than standard FAX gels, while continued enhancement in OD-dose sensitivity with increased sucrose concentrations beyond 2.0 g/l was found only for the oxygenated sucrose FAX gels. Both the molar absorption coefficient of the ferric ion-xylenol orange complex at 543 nm and gel pH were not affected by the presence of sucrose, with the implication that the higher OD-dose sensitivity of gels with saccharides is due to increased chain reaction production of ferric ions.


Assuntos
Carboidratos/efeitos da radiação , Densitometria , Análise de Falha de Equipamento , Compostos Ferrosos/efeitos da radiação , Géis/efeitos da radiação , Imageamento por Ressonância Magnética , Radiometria/instrumentação , Carboidratos/química , Compostos Ferrosos/química , Géis/química , Fenóis , Doses de Radiação , Radiometria/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Sulfóxidos , Xilenos
11.
Phys Med Biol ; 47(19): 3441-63, 2002 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-12408474

RESUMO

Polymer gel dosimeters offer a wide range of potential applications in the three-dimensional verification of complex dose distribution such as in intensity-modulated radiotherapy (IMRT). Until now, however, polymer gel dosimeters have not been widely used in the clinic. One of the reasons is that they are difficult to manufacture. As the polymerization in polymer gels is inhibited by oxygen, all free oxygen has to be removed from the gels. For several years this was achieved by bubbling nitrogen through the gel solutions and by filling the phantoms in a glove box that is perfused with nitrogen. Recently another gel formulation was proposed in which oxygen is bound in a metallo-organic complex thus removing the problem of oxygen inhibition. The proposed gel consists of methacrylic acid, gelatin, ascorbic acid, hydroquinone and copper(II)sulphate and is given the acronym MAGIC gel dosimeter. These gels are fabricated under normal atmospheric conditions and are therefore called 'normoxic' gel dosimeters. In this study, a chemical analysis on the MAGIC gel was performed. The composition of the gel was varied and its radiation response was evaluated. The role of different chemicals and the reaction kinetics are discussed. It was found that ascorbic acid alone was able to bind the oxygen and can thus be used as an anti-oxidant in a polymer gel dosimeter. It was also found that the anti-oxidants N-acetyl-cysteine and tetrakis(hydroxymethyl)phosphonium were effective in scavenging the oxygen. However, the rate of oxygen scavenging is dependent on the anti-oxidant and its concentration with tetrakis(hydroxymethyl)phosphonium being the most reactive anti-oxidants. Potentiometric oxygen measurements in solution provide an easy way to get a first impression on the rate of oxygen scavenging. It is shown that cupper(II)sulphate operates as a catalyst in the oxidation of ascorbic acid. We, therefore, propose some new normoxic gel formulations that have a less complicated chemical formulation than the MAGIC gel.


Assuntos
Compostos Organofosforados/farmacologia , Radiometria/métodos , Radioterapia Conformacional/métodos , Acetilcisteína/farmacologia , Antioxidantes/farmacologia , Ácido Ascórbico/farmacologia , Relação Dose-Resposta a Droga , Relação Dose-Resposta à Radiação , Modelos Químicos , Oxigênio/metabolismo , Imagens de Fantasmas , Fosfatos/farmacologia , Polímeros/química , Sensibilidade e Especificidade , Fatores de Tempo
12.
Phys Med Biol ; 47(14): 2459-70, 2002 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-12171334

RESUMO

In this study the stability of different polymer gel dosimeters is investigated. Further to a previous chemical stability study on a (6%T, 50%C) PAG gel, the change in slope and intercept of the linear part of the R2-dose plot is recorded with time for different gel formulations. In addition to this R2-dose-response stability study, the dose edge of a half-blocked field was recorded with time. Three different PAG type polymer gels, a hydroxyethyl acrylate (HEA) gel and two different normoxic polymer gels were investigated. In the PAG type polymer gels, the relative concentration of gelatin and comonomers was varied in order to study the influence of the different components, that constitute the dosimeter, on the stability. It is shown that the R2-dose-response stability is largely determined by the chemical composition of the gel dosimeters. All the PAG gel dosimeters and the normoxic gel dosimeters are found to preserve the integrity of the dose distribution up to 22 days after irradiation. The half-life of the change in dose sensitivity of a MAGIC gel is found to be 18 h compared to 5.7 h for a (6%T, 50%C) PAG gel. A maximum relative decrease in dose sensitivity of 21% was noted for the MAGIC gel compared to an increase of 50% for a (6%T, 50%C) PAG gel. A loss of integrity of the dose distribution was found in the HEA gel.


Assuntos
Relação Dose-Resposta à Radiação , Géis/efeitos da radiação , Teste de Materiais/métodos , Polímeros/efeitos da radiação , Radiometria/instrumentação , Resinas Acrílicas/classificação , Resinas Acrílicas/efeitos da radiação , Aldeídos , Radioisótopos de Cobalto , Análise de Falha de Equipamento/métodos , Meia-Vida , Aceleradores de Partículas , Polissacarídeos , Radiometria/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Fatores de Tempo
13.
J Anim Sci ; 72(9): 2227-36, 1994 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-8002441

RESUMO

A total of 240 weanling pigs (22 d of age and 5.3 kg average BW) were used to determine the effects of particle size of corn and two sorghum hybrids on diet processing, growth performance, apparent digestibility of nutrients, and morphology of the stomach and intestines in weanling pigs. Treatments were corn, hard endosperm sorghum, and soft endosperm sorghum milled to particle sizes (geometric mean) of 900, 700, 500, and 300 microns, in a 3 x 4 factorial arrangement. All diets were pelleted and the pigs were allowed to consume feed and water on an ad libitum basis. As particle size was reduced, production rate (tons/hour) decreased and energy required to mill (kilowatt hours/ton) increased. Corn required more energy to mill and had a lower production rate than the sorghums. For d 0 to 14, ADG and gain/feed increased linearly (P < .009 and P < .002, respectively) as particle size was decreased to 300 microns. However, there was a grain source x particle size interaction; pigs fed corn responded to particle size reduction more than pigs fed the sorghums (P < .04). For d 0 to 35, pigs fed diets with corn grew 23% faster and were 6% more efficient (P < .001) than pigs fed diets with sorghum. Gain/feed responded quadratically to reduction of particle size (P < .01), with maximum gain/feed at 500 microns for all grains. Lowest cost of gain (including milling and ingredient costs) was achieved at 500 to 700 microns for corn and 500 microns for the hard and soft sorghums. These data suggest that response to reducing particle size is greatest during the first 2 wk postweaning and that optimal particle size for corn and sorghums increases with age of nursery pigs.


Assuntos
Ração Animal , Grão Comestível , Manipulação de Alimentos , Suínos/fisiologia , Zea mays , Aminoácidos/análise , Ração Animal/análise , Ração Animal/economia , Animais , Análise Custo-Benefício , Digestão , Ingestão de Alimentos , Grão Comestível/química , Feminino , Manipulação de Alimentos/economia , Intestino Delgado/anatomia & histologia , Masculino , Tamanho da Partícula , Proteínas de Plantas/análise , Estômago/anatomia & histologia , Suínos/crescimento & desenvolvimento , Aumento de Peso , Zea mays/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...