Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Clin Imaging ; 100: 7-9, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37120923

RESUMO

The Kissing ovaries sign is a radiological sign seen in women with deep pelvic endometriosis. It refers to abutment of the ovaries within the cul-de-sac. The term kissing ovaries was first described by Ghezzi et al. (2005) and has been since used widely. When seen on imaging it indicates moderate to severe endometriosis with the ovaries tethered within abnormal pelvic soft tissue, which may warrant surgical management.


Assuntos
Endometriose , Ovário , Feminino , Humanos , Ovário/diagnóstico por imagem , Endometriose/diagnóstico por imagem , Escavação Retouterina/cirurgia , Pelve
2.
NMR Biomed ; 31(1)2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29130539

RESUMO

The purpose of this work was to investigate sources of bias in magnetic resonance imaging (MRI) liver fat quantification that lead to a dependence of the proton density fat fraction (PDFF) on the number of echoes. This was a retrospective analysis of liver MRI data from 463 subjects. The magnitude signal variation with TE from spoiled gradient echo images was curve fitted to estimate the PDFF using a model that included monoexponential R2 * decay and a multi-peak fat spectrum. Additional corrections for non-exponential decay (Gaussian), bi-exponential decay, degree of fat saturation, water frequency shift and noise bias were introduced. The fitting error was minimized with respect to 463 × 3 = 1389 subject-specific parameters and seven additional parameters associated with these corrections. The effect on PDFF was analyzed, notably the dependence on the number of echoes. The effects on R2 * were also analyzed. The results showed that the inclusion of bias corrections resulted in an increase in the quality of fit (r2 ) in 427 of 463 subjects (i.e. 92.2%) and a reduction in the total fitting error (residual norm) of 43.6%. This was largely a result of the Gaussian decay (57.8% of the reduction), fat spectrum (31.0%) and biexponential decay (8.8%) terms. The inclusion of corrections was also accompanied by a decrease in the dependence of PDFF on the number of echoes. Similar analysis of R2 * showed a decrease in the dependence on the number of echoes. Comparison of PDFF with spectroscopy indicated excellent agreement before and after correction, but the latter exhibited lower bias on a Bland-Altman plot (1.35% versus 0.41%). In conclusion, correction for known and expected biases in PDFF quantification in liver reduces the fitting error, decreases the dependence on the number of echoes and increases the accuracy.


Assuntos
Adiposidade , Fígado/metabolismo , Imageamento por Ressonância Magnética , Prótons , Adolescente , Adulto , Idoso , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise de Regressão , Adulto Jovem
3.
Hepatology ; 67(3): 858-872, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29028128

RESUMO

We assessed the performance of magnetic resonance imaging (MRI) proton density fat fraction (PDFF) in children to stratify hepatic steatosis grade before and after treatment in the Cysteamine Bitartrate Delayed-Release for the Treatment of Nonalcoholic Fatty Liver Disease in Children (CyNCh) trial, using centrally scored histology as reference. Participants had multiecho 1.5 Tesla (T) or 3T MRI on scanners from three manufacturers. Of 169 enrolled children, 110 (65%) and 83 (49%) had MRI and liver biopsy at baseline and at end of treatment (EOT; 52 weeks), respectively. At baseline, 17% (19 of 110), 28% (31 of 110), and 55% (60 of 110) of liver biopsies showed grades 1, 2, and 3 histological steatosis; corresponding PDFF (mean ± SD) values were 10.9 ± 4.1%, 18.4 ± 6.2%, and 25.7 ± 9.7%, respectively. PDFF classified grade 1 versus 2-3 and 1-2 versus 3 steatosis with areas under receiving operator characteristic curves (AUROCs) of 0.87 (95% confidence interval [CI], 0.80, 0.94) and 0.79 (0.70, 0.87), respectively. PDFF cutoffs at 90% specificity were 17.5% for grades 2-3 steatosis and 23.3% for grade 3 steatosis. At EOT, 47% (39 of 83), 41% (34 of 83), and 12% (10 of 83) of biopsies showed improved, unchanged, and worsened steatosis grade, respectively, with corresponding PDFF (mean ± SD) changes of -7.8 ± 6.3%, -1.2 ± 7.8%, and 4.9 ± 5.0%, respectively. PDFF change classified steatosis grade improvement and worsening with AUROCs (95% CIs) of 0.76 (0.66, 0.87) and 0.83 (0.73, 0.92), respectively. PDFF change cut-off values at 90% specificity were -11.0% and +5.5% for improvement and worsening. CONCLUSION: MRI-estimated PDFF has high diagnostic accuracy to both classify and predict histological steatosis grade and change in histological steatosis grade in children with NAFLD. (Hepatology 2018;67:858-872).


Assuntos
Cisteamina/uso terapêutico , Eliminadores de Cistina/uso terapêutico , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Adolescente , Criança , Estudos Transversais , Método Duplo-Cego , Feminino , Humanos , Fígado/patologia , Masculino , Hepatopatia Gordurosa não Alcoólica/tratamento farmacológico , Hepatopatia Gordurosa não Alcoólica/patologia , Estudos Prospectivos , Prótons , Sensibilidade e Especificidade
4.
Gastroenterology ; 153(3): 753-761, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28624576

RESUMO

BACKGROUND & AIMS: We assessed the diagnostic performance of magnetic resonance imaging (MRI) proton density fat fraction (PDFF) in grading hepatic steatosis and change in hepatic steatosis in adults with nonalcoholic steatohepatitis (NASH) in a multi-center study, using central histology as reference. METHODS: We collected data from 113 adults with NASH participating in a multi-center, randomized, double-masked, placebo-controlled, phase 2b trial to compare the efficacy cross-sectionally and longitudinally of obeticholic acid vs placebo. Hepatic steatosis was assessed at baseline and after 72 weeks of obeticholic acid or placebo by liver biopsy and MRI (scanners from different manufacturers, at 1.5T or 3T). We compared steatosis estimates by PDFF vs histology. Histologic steatosis grade was scored in consensus by a pathology committee. Cross-validated receiver operating characteristic (ROC) analyses were performed. RESULTS: At baseline, 34% of subjects had steatosis grade 0 or 1, 39% had steatosis grade 2, and 27% had steatosis grade 3; corresponding mean PDFF values were 9.8%±3.7%, 18.1%±4.3%, and 30.1%±8.1%. PDFF classified steatosis grade 0-1 vs 2-3 with an area under the ROC curve (AUROC) of 0.95 (95% CI, 0.91-0.98), and grade 0-2 vs grade 3 steatosis with an AUROC of 0.96 (95% CI, 0.93-0.99). PDFF cut-off values at 90% specificity were 16.3% for grades 2-3 and 21.7% for grade 3, with corresponding sensitivities of 83% and 84%. After 72 weeks' of obeticholic vs placebo, 42% of subjects had a reduced steatosis grade (mean reduction in PDFF from baseline of 7.4%±8.7%), 49% had no change in steatosis grade (mean increase in PDFF from baseline of 0.3%±6.3%), and 9% had an increased steatosis grade (mean increase in PDFF from baseline of 7.7%±6.0%). PDFF change identified subjects with reduced steatosis grade with an AUROC of 0.81 (95% CI, 0.71-0.91) and increased steatosis grade with an AUROC of 0.81 (95% CI, 0.63-0.99). A PDFF reduction of 5.15% identified subjects with reduced steatosis grade with 90% specificity and 58% sensitivity, whereas a PDFF increase of 5.6% identified those with increased steatosis grade with 90% specificity and 57% sensitivity. CONCLUSIONS: Based on data from a phase 2 randomized controlled trial of adults with NASH, PDFF estimated by MRI scanners of different field strength and at different sites, accurately classifies grades and changes in hepatic steatosis when histologic analysis of biopsies is used as a reference.


Assuntos
Adiposidade , Ácido Quenodesoxicólico/análogos & derivados , Fígado/patologia , Imageamento por Ressonância Magnética/métodos , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Hepatopatia Gordurosa não Alcoólica/patologia , Adulto , Área Sob a Curva , Biópsia , Ácido Quenodesoxicólico/uso terapêutico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Método Simples-Cego
5.
J Magn Reson Imaging ; 43(2): 398-406, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26201284

RESUMO

PURPOSE: To determine the accuracy and the effect of possible subject-based confounders of magnitude-based magnetic resonance imaging (MRI) for estimating hepatic proton density fat fraction (PDFF) for different numbers of echoes in adults with known or suspected nonalcoholic fatty liver disease, using MR spectroscopy (MRS) as a reference. MATERIALS AND METHODS: In this retrospective analysis of 506 adults, hepatic PDFF was estimated by unenhanced 3.0T MRI, using right-lobe MRS as reference. Regions of interest placed on source images and on six-echo parametric PDFF maps were colocalized to MRS voxel location. Accuracy using different numbers of echoes was assessed by regression and Bland-Altman analysis; slope, intercept, average bias, and R2 were calculated. The effect of age, sex, and body mass index (BMI) on hepatic PDFF accuracy was investigated using multivariate linear regression analyses. RESULTS: MRI closely agreed with MRS for all tested methods. For three- to six-echo methods, slope, regression intercept, average bias, and R2 were 1.01-0.99, 0.11-0.62%, 0.24-0.56%, and 0.981-0.982, respectively. Slope was closest to unity for the five-echo method. The two-echo method was least accurate, underestimating PDFF by an average of 2.93%, compared to an average of 0.23-0.69% for the other methods. Statistically significant but clinically nonmeaningful effects on PDFF error were found for subject BMI (P range: 0.0016 to 0.0783), male sex (P range: 0.015 to 0.037), and no statistically significant effect was found for subject age (P range: 0.18-0.24). CONCLUSION: Hepatic magnitude-based MRI PDFF estimates using three, four, five, and six echoes, and six-echo parametric maps are accurate compared to reference MRS values, and that accuracy is not meaningfully confounded by age, sex, or BMI.


Assuntos
Fígado/patologia , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética/métodos , Hepatopatia Gordurosa não Alcoólica/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Adulto Jovem
6.
Abdom Imaging ; 40(8): 3084-90, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26205992

RESUMO

PURPOSE: To assess feasibility of and agreement between magnetic resonance imaging (MRI) and magnetic resonance spectroscopy (MRS) for estimating hepatic proton density fat fraction (PDFF) in children with known or suspected nonalcoholic fatty liver disease (NAFLD). MATERIALS AND METHODS: Children were included in this study from two previous research studies in each of which three MRI and three MRS acquisitions were obtained. Sequence acceptability, and MRI- and MRS-estimated PDFF were evaluated. Agreement of MRI- with MRS-estimated hepatic PDFF was assessed by linear regression and Bland-Altman analysis. Age, sex, BMI-Z score, acquisition time, and artifact score effects on MRI- and MRS-estimated PDFF agreement were assessed by multiple linear regression. RESULTS: Eighty-six children (61 boys and 25 girls) were included in this study. Slope and intercept from regressing MRS-PDFF on MRI-PDFF were 0.969 and 1.591%, respectively, and the Bland-Altman bias and 95% limits of agreement were 1.17% ± 2.61%. MRI motion artifact score was higher in boys than girls (by 0.21, p = 0.021). Higher BMI-Z score was associated with lower agreement between MRS and MRI (p = 0.045). CONCLUSION: Hepatic PDFF estimation by both MRI and MRS is feasible, and MRI- and MRS-estimated PDFF agree closely in children with known or suspected NAFLD.


Assuntos
Fígado/patologia , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Hepatopatia Gordurosa não Alcoólica/patologia , Adolescente , Artefatos , Criança , Estudos Transversais , Estudos de Viabilidade , Feminino , Humanos , Masculino , Prótons , Reprodutibilidade dos Testes , Estudos Retrospectivos
7.
AJR Am J Roentgenol ; 204(3): 527-35, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25714281

RESUMO

OBJECTIVE. The purpose of this study is to evaluate the per-patient diagnostic performance of an abbreviated gadoxetic acid-enhanced MRI protocol for hepatocellular carcinoma (HCC) surveillance. MATERIALS AND METHODS. A retrospective review identified 298 consecutive patients at risk for HCC enrolled in a gadoxetic acid-enhanced MRI-based HCC surveillance program. For each patient, the first gadoxetic acid-enhanced MRI was analyzed. To simulate an abbreviated protocol, two readers independently read two image sets per patient: set 1 consisted of T1-weighted 20-minute hepatobiliary phase and T2-weighted single-shot fast spin-echo (SSFSE) images; set 2 included diffusion-weighted imaging (DWI) and images from set 1. Image sets were scored as positive or negative according to the presence of at least one nodule 10 mm or larger that met the predetermined criteria. Agreement was assessed using Cohen kappa statistics. A composite reference standard was used to determine the diagnostic performance of each image set for each reader. RESULTS. Interreader agreement was substantial for both image sets (κ = 0.72 for both) and intrareader agreement was excellent (κ = 0.97-0.99). Reader performance for image set 1 was sensitivity of 85.7% for reader A and 79.6% for reader B, specificity of 91.2% for reader A and 95.2% for reader B, and negative predictive value of 97.0% for reader A and 96.0% for reader B. Reader performance for image set 2 was nearly identical, with only one of 298 examinations scored differently on image set 2 compared with set 1. CONCLUSION. An abbreviated MRI protocol consisting of T2-weighted SSFSE and gadoxetic acid-enhanced hepatobiliary phase has high negative predictive value and may be an acceptable method for HCC surveillance. The inclusion of a DWI sequence did not significantly alter the diagnostic performance of the abbreviated protocol.


Assuntos
Carcinoma Hepatocelular/diagnóstico , Meios de Contraste , Gadolínio DTPA , Neoplasias Hepáticas/diagnóstico , Imageamento por Ressonância Magnética , Idoso , Estudos Transversais , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Vigilância da População , Reprodutibilidade dos Testes , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...