Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 152
Filtrar
1.
Br J Anaesth ; 2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38862381

RESUMO

BACKGROUND: Recommendations suggest favouring regional over general anaesthesia to reduce impact on postoperative sleep apnoea severity, but there is currently no evidence to support this. We compared the impact of general vs spinal anaesthesia on postoperative sleep apnoea severity and assessed the evolution of sleep apnoea severity up to the third postoperative night. METHODS: This post hoc analysis used pooled data from two previous randomised controlled trials in patients undergoing total hip arthroplasty under general or spinal anaesthesia (n=96), without performing a preliminary power analysis. All participants underwent respiratory polygraphy before surgery and on the first and third postoperative nights. The primary outcomes were the supine apnoea-hypopnea index on the first postoperative night and the evolution of the supine apnoea-hypopnea index up to the third postoperative night. Secondary outcomes included the oxygen desaturation index on the first and third postoperative nights. RESULTS: In the general and spinal anaesthesia groups, mean (95% confidence interval) values for the supine apnoea-hypopnoea index on the first postoperative night were 20 (16-25) and 21 (16-26) events h-1 (P=0.82), respectively; corresponding values on the third postoperative night were 34 (22-45) and 35 (20-49) events h-1 (P=0.91). The generalised estimating equations model showed a significant time effect. Secondary outcomes were similar in the two groups. CONCLUSIONS: Use of spinal anaesthesia compared with general anaesthesia was not associated with a reduction in postoperative sleep apnoea severity, which was worse on the third postoperative night. CLINICAL TRIAL REGISTRATION: NCT02717780 and NCT02566226.

2.
Psychiatry Res ; 338: 115934, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38833937

RESUMO

Sleep disturbances are well-known symptoms of major depressive disorder (MDD). However, the prospective risk of MDD in the presence of sleep disturbances in a general population-based cohort is not well known. This study investigated associations between both polysomnography (PSG)-based or subjective sleep features and incident MDD. Participants representative of the general population who had never had MDD completed sleep questionnaires (n = 2000) and/or underwent PSG (n = 717). Over 8 years' follow-up, participants completed psychiatric interviews enabling the diagnosis of MDD. Survival Cox models were used to analyze associations between sleep features and MDD incidence. A higher Epworth Sleepiness Scale and presence of insomnia symptoms were significantly associated with a higher incidence of MDD (hazard ratio [HR] [95 % confidence interval (CI)]: 1.062 [1.022-1.103], p = 0.002 and 1.437 [1.064-1.940], p = 0.018, respectively). Higher density of rapid eye movements in rapid eye movement (REM) sleep was associated with a higher incidence of MDD in men (HR 1.270 [95 % CI 1.064-1.516], p = 0.008). In women, higher delta power spectral density was associated with a lower MDD incidence (HR 0.674 [95 % CI 0.463-0.981], p = 0.039). This study confirmed the associations between subjective and objective sleep features and the incidence of MDD in a large community dwelling cohort.


Assuntos
Transtorno Depressivo Maior , Polissonografia , Transtornos do Sono-Vigília , Humanos , Masculino , Transtorno Depressivo Maior/epidemiologia , Feminino , Adulto , Pessoa de Meia-Idade , Incidência , Transtornos do Sono-Vigília/epidemiologia , Estudos de Coortes , Distúrbios do Início e da Manutenção do Sono/epidemiologia , Modelos de Riscos Proporcionais , Inquéritos e Questionários , Fatores de Risco
4.
Ann Am Thorac Soc ; 21(4): 651-657, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38241012

RESUMO

Rationale: Adaptive servo-ventilation (ASV) effectively treats sleep-disordered breathing, including central sleep apnea (CSA) and coexisting obstructive sleep apnea (OSA).Objectives: The prospective, multicenter European READ-ASV (Registry on the Treatment of Central and Complex Sleep-Disordered Breathing with Adaptive Servo-Ventilation) registry investigated the effects of first-time ASV therapy on disease-specific quality of life (QoL).Methods: The registry enrolled adults with CSA with or without OSA who had ASV therapy prescribed between September 2017 and March 2021. The primary endpoint was change in disease-specific QoL (Functional Outcomes of Sleep Questionnaire [FOSQ]) score between baseline and 12-month follow-up. Sleepiness determined using the Epworth Sleepiness Scale (ESS) score was a key secondary outcome. For subgroup analysis, participants were classified as symptomatic (FOSQ score < 17.9 and/or ESS score > 10) or asymptomatic (FOSQ score ⩾ 17.9 and/or ESS score ⩽ 10).Results: A total of 801 individuals (age, 67 ± 12 yr; 14% female; body mass index, 31 ± 5 kg/m2; apnea-hypopnea index, 48 ± 22/h) were enrolled; analyses include those with paired baseline and follow-up data. After 12 ± 3 months on ASV, median (interquartile range) FOSQ score had increased significantly from baseline (+0.8 [-0.2 to 2.2]; P < 0.001; n = 499). This was due to a significantly increased FOSQ score in symptomatic participants (+1.69 [0.38 to 3.05]), with little change in asymptomatic individuals (+0.11 [-0.39 to 0.54]). The median ESS score also improved significantly from baseline during ASV (-2.0 [-5.0 to 0.0]; P < 0.001).Conclusions: ASV treatment of CSA with or without coexisting OSA was associated with improvements in disease-specific QoL and daytime sleepiness, especially in individuals with sleep-disordered breathing symptoms before therapy initiation. These improvements in patient-reported outcomes support the use of ASV in this population.


Assuntos
Insuficiência Cardíaca , Síndromes da Apneia do Sono , Apneia do Sono Tipo Central , Apneia Obstrutiva do Sono , Adulto , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Qualidade de Vida , Estudos Prospectivos , Sonolência , Síndromes da Apneia do Sono/terapia , Síndromes da Apneia do Sono/complicações , Apneia Obstrutiva do Sono/complicações , Resultado do Tratamento
5.
J Sleep Res ; 33(1): e13938, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37309703

RESUMO

Research on the relationship between obstructive sleep apnea and cognitive functioning has yielded conflicting results, particularly in the older population, and moderators of this association have rarely been studied. Here we investigated the cross-sectional association between obstructive sleep apnea and cognitive functioning as well as the moderating effect of age, sex, apolipoprotein E4, and obesity on this association among community-dwelling older people. We analysed data from 496 participants (71.4 ± 4.4 years; 45.6% men) of the HypnoLaus study who underwent polysomnography and a battery of neuropsychological tests. The sample was categorised as no-to-mild obstructive sleep apnea (apnea-hypopnea index 0-14.9/h; reference), moderate obstructive sleep apnea (apnea-hypopnea index 15.0-29.9/h), or severe obstructive sleep apnea (apnea-hypopnea index ≥30/h). Regression and moderation analyses were performed with adjustment for confounders. Apolipoprotein E4 and obesity moderated the association between severe obstructive sleep apnea and processing speed, whereas no moderating effects were found for age and sex. In apolipoprotein E4 carriers only, severe obstructive sleep apnea was associated with lower performance in Stroop condition 1 (B = 3.13, p = 0.024). In obese participants only, severe obstructive sleep apnea was associated with lower performance in Stroop condition 1 (B = 3.02, p = 0.025) and Stroop condition 2 (B = 3.30, p = 0.034). Severe obstructive sleep apnea was also associated with lower executive function in the whole sample according to Stroop condition 3 (B = 3.44, p = 0.020) and Stroop interference score (B = 0.24, p = 0.006). Our findings support associations of severe obstructive sleep apnea (but not moderate obstructive sleep apnea) with lower performance in processing speed and executive function in the older general population. Apolipoprotein E4 and obesity appear to be vulnerability factors that strengthen the association between severe obstructive sleep apnea and lower performance in processing speed.


Assuntos
Apolipoproteína E4 , Apneia Obstrutiva do Sono , Masculino , Humanos , Idoso , Feminino , Apolipoproteína E4/genética , Estudos Transversais , Apneia Obstrutiva do Sono/complicações , Apneia Obstrutiva do Sono/epidemiologia , Cognição , Obesidade/complicações , Obesidade/epidemiologia
6.
Eur Heart J ; 44(47): 4968-4978, 2023 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-37860848

RESUMO

BACKGROUND AND AIMS: Evidence on the link between sleep patterns and cardiovascular diseases (CVDs) in the community essentially relies on studies that investigated one single sleep pattern at one point in time. This study examined the joint effect of five sleep patterns at two time points with incident CVD events. METHODS: By combining the data from two prospective studies, the Paris Prospective Study III (Paris, France) and the CoLaus|PsyCoLaus study (Lausanne, Switzerland), a healthy sleep score (HSS, range 0-5) combining five sleep patterns (early chronotype, sleep duration of 7-8 h/day, never/rarely insomnia, no sleep apnoea, and no excessive daytime sleepiness) was calculated at baseline and follow-up. RESULTS: The study sample included 11 347 CVD-free participants aged 53-64 years (44.6% women). During a median follow-up of 8.9 years [interquartile range (IQR): 8.0-10.0], 499 first CVD events occurred (339 coronary heart disease (CHD) and 175 stroke). In multivariate Cox analysis, the risk of CVD decreased by 18% [hazard ratio (HR) 0.82, 95% confidence interval (CI) 0.76-0.89] per one-point increment in the HSS. After a median follow-up of 6.0 years (IQR: 4.0-8.0) after the second follow-up, 262 first CVD events occurred including 194 CHD and 72 stroke. After adjusting for baseline HSS and covariates, the risk of CVD decreased by 16% (HR 0.84, 95% CI 0.73-0.97) per unit higher in the follow-up HSS over 2-5 years. CONCLUSIONS: Higher HSS and HSS improvement over time are associated with a lower risk of CHD and stroke in the community.


Assuntos
Doenças Cardiovasculares , Doença das Coronárias , Acidente Vascular Cerebral , Humanos , Feminino , Masculino , Doenças Cardiovasculares/epidemiologia , Estudos Prospectivos , Fatores de Risco , Acidente Vascular Cerebral/epidemiologia , Doença das Coronárias/epidemiologia , Sono
8.
Sleep Med ; 109: 197-201, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37473717

RESUMO

OBJECTIVE: The current evidence of a relationship between periodic leg movements during sleep (PLMS) and cognitive functioning is limited and inconsistent. This cross-sectional study assessed associations between PLMS and cognitive functioning among community-dwelling older adults. METHODS: We included community-dwelling older adults who underwent a polysomnography and a cognitive assessment. The PLMS index (PLMI) and PLMS arousal index (PLMAI) were categorized into tertiles: PLMI <5/h (reference), 5-29.9/h, ≥30/h; and PLMAI <1/h (reference), 1-4.9/h, ≥5/h. The cognitive assessment consisted of ten scores covering the main cognitive domains: global cognition, processing speed, executive function, language, episodic verbal memory, and visuospatial function. Associations between PLMI, PLMAI, and cognitive scores were assessed using regression unadjusted and adjusted models. RESULTS: A total of 579 individuals without dementia were included (mean age: 71.5 ± 4.4 years; men 45.4%). The number of participants in the high-PLMI categories, 5-29.9/h and ≥30/h, was 185 (32.0%) and 171 (29.5%), respectively. Participants in the high-PLMI categories showed no significant difference compared to the reference group regarding their cognitive performance according to the unadjusted and adjusted models. Similarly, we found no association between PLMAI severity and cognitive functioning. CONCLUSIONS: This study shows no cross-sectional association between PLMS severity and cognitive functioning among community-dwelling older adults. However, given the paucity of data in this field, further studies are needed to clarify the relationship between PLMS and cognitive functioning.


Assuntos
Síndrome da Mioclonia Noturna , Masculino , Humanos , Idoso , Síndrome da Mioclonia Noturna/epidemiologia , Perna (Membro) , Estudos Transversais , Sono , Cognição
10.
Pharmacy (Basel) ; 11(3)2023 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-37368431

RESUMO

(1) Introduction: Chronic insomnia (CI) reduces quality of life and may trigger depression and cardiovascular diseases. The European Sleep Research Society recommends cognitive behavioural therapy (CBT-I) as the first-line treatment. Because a recent study in Switzerland demonstrated that this recommendation was inconsistently followed by primary care physicians, we hypothesised that pharmacists also deviate from these guidelines. The aim of this study is to describe current treatment practices for CI recommended by pharmacists in Switzerland, compare them to guidelines and examine their attitudes towards CBT-I. (2) Methods: A structured survey was sent to all the members of the Swiss Pharmacists Association, containing three clinical vignettes describing typical CI pharmacy clients. Treatments had to be prioritised. The prevalence of CI, and the pharmacists' knowledge and interest in CBT-I were assessed. (3) Results: Of 1523 pharmacies, 123 pharmacists (8%) completed the survey. Despite large variations, valerian (96%), relaxation therapy (94%) and other phytotherapies (85%) were most recommended. Although most pharmacists did not know about CBT-I (72%) and only 10% had recommended it, most were very interested (64%) in education. Missing financial compensation hampers the recommendation of CBT-I. (4) Conclusions: Contrary to existing European guidelines, community pharmacists in Switzerland mostly recommended valerian, relaxation therapy and other phytotherapies for treating CI. This might be connected to the client's expectation of pharmacy services, e.g., medication dispensing. While pharmacists recommend sleep hygiene regularly, most did not know of CBT-I as an overarching concept but were willing to learn. Future studies should test the effects of dedicated training about CI and changes in the financial compensation for counselling for CI in pharmacies.

11.
BMC Psychol ; 11(1): 145, 2023 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-37138296

RESUMO

BACKGROUND: The daily working life of many employees requires the use of modern information and communication technology (ICT) devices such as computers, tablets, and smartphones. The double-edged nature of digital work environments has been increasingly highlighted. Benefits such as increased flexibility come at a personal cost. One of the potential downsides is workplace telepressure, i.e., the experience of urge and preoccupation to quickly reply to work-related messages and demands using ICT. There is initial - mainly survey-based-evidence that workplace telepressure may have negative effects on a variety of wellbeing and health outcomes. AIMS AND HYPOTHESES: Adopting the Effort-Recovery Model and the concept of allostatic load as theoretical frameworks, the present study aims to investigate the hypothesis that workplace telepressure is significantly associated with increased "wear and tear", in the form of more psychosomatic complaints, worse sleep quality (self-reported and actigraphy-based), worse mood, and biological alterations (lower cardiac vagal tone, lower anabolic balance defined as the ratio of salivary dehydroepiandrosterone to salivary cortisol, and higher salivary alpha-amylase). Additionally, the study aims to investigate the hypothesis that connection to work defined as work-related workload and work-related perseverative cognition plays a significant role in the mediation of these relationships. METHODS: To test our hypotheses, we will conduct an ambulatory assessment study with a convenience sample of 120 healthy workers regularly using ICTs for job communication. For one week, participants will be asked to complete electronic diaries assessing their level of workplace telepressure, psychosomatic complaints, sleep quality, mood, work-related workload, and work-related perseverative cognition. They will also continuously wear the Bittium Faros 180L ECG monitor, the wrist-worn actigraph MotionWatch 8, and perform saliva sampling five times per day. DISCUSSION: This study will be the most comprehensive ambulatory investigation of workplace telepressure and its psychophysiological concomitants to date and constitutes an important step towards understanding how high levels of workplace telepressure may lead in the long term to secondary alterations (e.g., hypertension, chronic inflammation) and disease (e.g., heart disease). The findings of this study are also anticipated to contribute to guiding the development and implementation of interventions, programs, and policies relevant to employees' digital wellbeing.


Assuntos
Comunicação , Local de Trabalho , Humanos , Local de Trabalho/psicologia , Inquéritos e Questionários , Autorrelato , Psicofisiologia
12.
Am J Respir Crit Care Med ; 207(12): 1620-1632, 2023 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-37017487

RESUMO

Rationale: It is currently unclear which patients with obstructive sleep apnea (OSA) are at increased cardiovascular risk. Objective: To investigate the value of pulse wave amplitude drops (PWADs), reflecting sympathetic activations and vasoreactivity, as a biomarker of cardiovascular risk in OSA. Methods: PWADs were derived from pulse oximetry-based photoplethysmography signals in three prospective cohorts: HypnoLaus (N = 1,941), the Pays-de-la-Loire Sleep Cohort (PLSC; N = 6,367), and "Impact of Sleep Apnea syndrome in the evolution of Acute Coronary syndrome. Effect of intervention with CPAP" (ISAACC) (N = 692). The PWAD index was the number of PWADs (>30%) per hour during sleep. All participants were divided into subgroups according to the presence or absence of OSA (defined as ⩾15 or more events per hour or <15/h, respectively, on the apnea-hypopnea index) and the median PWAD index. Primary outcome was the incidence of composite cardiovascular events. Measurements and Main Results: Using Cox models adjusted for cardiovascular risk factors (hazard ratio; HR [95% confidence interval]), patients with a low PWAD index and OSA had a higher incidence of cardiovascular events compared with the high-PWAD and OSA group and those without OSA in the HypnoLaus cohort (HR, 2.16 [1.07-4.34], P = 0.031; and 2.35 [1.12-4.93], P = 0.024) and in the PLSC (1.36 [1.13-1.63], P = 0.001; and 1.44 [1.06-1.94], P = 0.019), respectively. In the ISAACC cohort, the low-PWAD and OSA untreated group had a higher cardiovascular event recurrence rate than that of the no-OSA group (2.03 [1.08-3.81], P = 0.028). In the PLSC and HypnoLaus cohorts, every increase of 10 events per hour in the continuous PWAD index was negatively associated with incident cardiovascular events exclusively in patients with OSA (HR, 0.85 [0.73-0.99], P = 0.031; and HR, 0.91 [0.86-0.96], P < 0.001, respectively). This association was not significant in the no-OSA group and the ISAACC cohort. Conclusions: In patients with OSA, a low PWAD index reflecting poor autonomic and vascular reactivity was independently associated with a higher cardiovascular risk.


Assuntos
Doenças Cardiovasculares , Apneia Obstrutiva do Sono , Humanos , Doenças Cardiovasculares/etiologia , Doenças Cardiovasculares/complicações , Estudos Prospectivos , Fatores de Risco , Apneia Obstrutiva do Sono/complicações , Fatores de Risco de Doenças Cardíacas , Biomarcadores
13.
ERJ Open Res ; 9(2)2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37077553

RESUMO

Background: Although adaptive servo-ventilation (ASV) effectively supresses central sleep apnoea (CSA), little is known about real-world indications of ASV therapy and its effects on quality of life (QoL). Methods: This report details the design, baseline characteristics, indications for ASV and symptom burden in patients enrolled in the Registry on the Treatment of Central and Complex Sleep-Disordered Breathing with Adaptive Servo-Ventilation (READ-ASV). This multicentre, European, non-interventional trial enrolled participants prescribed ASV in clinical practice between September 2017 and March 2021. An expert review board assigned participants to ASV indications using a guideline-based semi-automated algorithm. The primary end-point was change in disease-specific QoL based on the Functional Outcomes of Sleep Questionnaire (FOSQ) from baseline to 12-month follow-up. Results: The registry population includes 801 participants (age 67±12 years, 14% female). Indications for ASV were treatment-emergent or persistent CSA (56%), CSA in cardiovascular disease (31%), unclassified CSA (2%), coexisting obstructive sleep apnoea and CSA (4%), obstructive sleep apnoea (3%), CSA in stroke (2%) and opioid-induced CSA (1%). Baseline mean apnoea--hypopnoea index was 48±23 events·h-1 (≥30 events·h-1 in 78%), FOSQ score was 16.7±3.0 (<17.9 in 54%) and Epworth Sleepiness Scale (ESS) score was 8.8±4.9 (>10 in 34%); 62% of patients were symptomatic (FOSQ score <17.9 or ESS score >10). Conclusion: The most common indications for ASV were treatment-emergent or persistent CSA or CSA in cardiovascular disease (excluding systolic heart failure). Patients using ASV in clinical practice had severe sleep-disordered breathing and were often symptomatic. One-year follow-up will provide data on the effects of ASV on QoL, respiratory parameters and clinical outcomes in these patients.

14.
Psychiatry Res ; 324: 115213, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37098299

RESUMO

Insomnia and its opposite hypersomnia are part of the diagnostic criteria for major depressive disorder (MDD). However, no study has investigated whether the postulated sleep alterations in clinical subtypes of MDD are reflected in polysomnography (PSG)-derived objective sleep measures. The objective of this study was to establish associations between the melancholic, atypical and unspecified subtypes of MDD and objective PSG-based sleep features. This cross-sectional analysis included 1820 community-dwelling individuals who underwent PSG and a semi-structured psychiatric interview to elicit diagnostic criteria for MDD and its subtypes. Adjusted robust linear regression was used to assess associations between MDD subtypes and PSG-derived objective sleep measures. Current melancholic MDD was significantly associated with decreased absolute delta power and sleep efficiency and with increased wake after sleep onset. Remitted unspecified MDD was significantly associated with increased rapid eye movements density. No other significant associations were identified. Our findings reflect that some PSG-based sleep features differed in MDD subtypes compared with no MDD. The largest number of significant differences were observed for current melancholic MDD, whereas only rapid eye movements density could represent a risk factor for MDD as it was the only sleep measure that was also associated with MDD in remitted participants.


Assuntos
Transtorno Depressivo Maior , Humanos , Transtorno Depressivo Maior/psicologia , Polissonografia , Estudos Transversais , Sono , Depressão
15.
Sleep ; 46(7)2023 07 11.
Artigo em Inglês | MEDLINE | ID: mdl-36861433

RESUMO

STUDY OBJECTIVES: Although recent investigations combining noradrenergic and antimuscarinic drugs have shown promising short-term results to treat obstructive sleep apnea (OSA), the mid-term effect and optimal dosage remain uncertain. The present study aimed to evaluate the effect of 1 week of 5 mg oxybutynin and 6 mg reboxetine (oxy-reb) on OSA versus placebo. METHODS: We performed a randomized, placebo-controlled, double-blind, crossover trial comparing the effect of 1 week of oxy-reb versus 1 week of placebo on OSA severity. At-home polysomnography was performed at baseline and after each week of intervention. RESULTS: Fifteen participants (male 66.7%) aged 59 [44-62] years (median [interquartile range]) with a mean body mass index of 33.1 ± 6.6 kg/m2 were included. No significant difference in apnea-hypopnea index (AHI) was observed between conditions (estimated marginal means [95% confidence interval] at baseline: 39.7 [28.5-55.3]; oxy-reb: 34.5 [22.7-52.3]; placebo: 37.9 [27.1-52.9]; p = 0.652), but oxy-reb improved average oxygen desaturation (p = 0.016) and hypoxic burden (p = 0.011) and lowered sleep efficiency (p = 0.019) and rapid eye movement sleep (p = 0.002). Moreover, participants reported reduced sleep quality during the week of oxy-reb compared to the week of placebo (4.7 [3.5; 5.9] vs. 6.5 [5.5; 7.5] on a 0-10 visual analogic scale, respectively; p = 0.001). No significant differences in sleepiness, vigilance, and fatigue were observed. No serious adverse events occurred. CONCLUSIONS: Administration of oxybutynin 5 mg and reboxetine 6 mg did not improve OSA severity assessed by AHI, but did alter sleep architecture and sleep quality. Reduced average oxygen desaturation and hypoxic burden were also observed. CLINICAL TRIAL: ClinicalTrials.gov, https://clinicaltrials.gov, NCT04394143.


Assuntos
Apneia Obstrutiva do Sono , Humanos , Masculino , Reboxetina , Estudos Cross-Over , Apneia Obstrutiva do Sono/tratamento farmacológico , Oxigênio , Método Duplo-Cego
17.
Respiration ; 102(5): 341-350, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36724753

RESUMO

BACKGROUND: Mechanical insufflation/exsufflation (MI-E) devices are often prescribed to patients with inefficient cough and recurrent infections, but their use in the home setting is not well characterized. OBJECTIVE: The objective of this study was to report a real-life experience and identify factors that are associated with home MI-E use in adult patients. METHODS: This is a cross-sectional observational study of adult subjects with neurological disease using MI-E at home for more than 3 months. RESULTS: A total of 43 patients were included. Median age (interquartile range) was 48 (31-64) years. The most common diagnosis was muscular dystrophy (n = 15), followed by multiple sclerosis (n = 7) and amyotrophic lateral sclerosis (n = 7). 24 subjects (56%) reported using the MI-E at least once weekly. Based on device data downloads, the median objective use was 23% of days analysed (approximately 2 times per week). The vast majority (94%) of all participants reported using the device at least daily during an infectious episode, while 62% reported having used the device in emergency situations such as bronchoaspiration. Reported use correlated well with objective use (r = 0.82). Most subjects reported an improvement in their respiratory health (64%) and were satisfied with the device (78%). Higher reported and objective use were associated with increased symptoms (p = 0.001) and higher satisfaction with the device (p = 0.008). We found no association between frequency of use and baseline cough peak flow (CPF), bulbar impairment, non-invasive ventilation use, living environment, or supervised administration. CONCLUSION: Regular home MI-E use was associated with greater symptom burden and overall satisfaction with the device and was not influenced by baseline CPF. Patients without substantial bronchorrhea might not use the MI-E regularly but might still need to use the device at home during acute events. Therefore, familiarity with the MI-E via appropriate and repeated practical training is crucial.


Assuntos
Tosse , Insuflação , Humanos , Adulto , Pessoa de Meia-Idade , Estudos Transversais , Suíça , Respiração Artificial
18.
Eur Respir J ; 61(4)2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36796834

RESUMO

BACKGROUND: The relationship between obstructive sleep apnoea (OSA) and cognitive decline remains controversial, especially in the elderly population. We used data from the HypnoLaus study to assess associations between OSA and longitudinal cognitive changes in a sample of community-dwelling elderly individuals. METHODS: We studied associations between polysomnographic OSA parameters (of breathing/hypoxaemia and sleep fragmentation) and cognitive changes over a 5-year period, after adjustment for potential confounders. The primary outcome was the annual change in cognitive scores. The moderating effects of age, sex and apolipoprotein E4 (ApoE4) status were also examined. RESULTS: 358 elderly individuals without dementia were included (mean±sd age 71.0±4.2 years; 42.5% males). A lower mean peripheral oxygen saturation (S pO2 ) during sleep was associated with a steeper decline in Mini-Mental State Examination (B= -0.12, p=0.004), Stroop test condition 1 (B=0.53, p=0.002) and Free and Cued Selective Reminding Test delayed free recall (B= -0.05, p=0.008). A longer time spent asleep with S pO2 <90% was associated with a steeper decline in Stroop test condition 1 (B=0.47, p=0.006). Moderation analysis showed that apnoea-hypopnoea index and oxygen desaturation index were associated with a steeper decline in global cognitive function, processing speed and executive function only in older participants, men and ApoE4 carriers. CONCLUSIONS: Our results provide evidence of the contribution of OSA and nocturnal hypoxaemia to cognitive decline in the elderly population.


Assuntos
Disfunção Cognitiva , Apneia Obstrutiva do Sono , Masculino , Humanos , Idoso , Feminino , Apolipoproteína E4/genética , Disfunção Cognitiva/complicações , Sono , Hipóxia/complicações
19.
Sleep ; 46(4)2023 04 12.
Artigo em Inglês | MEDLINE | ID: mdl-35670608

RESUMO

STUDY OBJECTIVES: Periodic limb movement in sleep is a common sleep phenotype characterized by repetitive leg movements that occur during or before sleep. We conducted a genome-wide association study (GWAS) of periodic limb movements in sleep (PLMS) using a joint analysis (i.e., discovery, replication, and joint meta-analysis) of four cohorts (MrOS, the Wisconsin Sleep Cohort Study, HypnoLaus, and MESA), comprised of 6843 total subjects. METHODS: The MrOS study and Wisconsin Sleep Cohort Study (N = 1745 cases) were used for discovery. Replication in the HypnoLaus and MESA cohorts (1002 cases) preceded joint meta-analysis. We also performed LD score regression, estimated heritability, and computed genetic correlations between potentially associated traits such as restless leg syndrome (RLS) and insomnia. The causality and direction of the relationships between PLMS and RLS was evaluated using Mendelian randomization. RESULTS: We found 2 independent loci were significantly associated with PLMS: rs113851554 (p = 3.51 × 10-12, ß = 0.486), an SNP located in a putative regulatory element of intron eight of MEIS1 (2p14); and rs9369062 (p = 3.06 × 10-22, ß = 0.2093), a SNP located in the intron region of BTBD9 (6p12); both of which were also lead signals in RLS GWAS. PLMS is genetically correlated with insomnia, risk of stroke, and RLS, but not with iron deficiency. Pleiotropy adjusted Mendelian randomization analysis identified a causal effect of RLS on PLMS. CONCLUSIONS: Because PLMS is more common than RLS, PLMS may have multiple causes and additional studies are needed to further validate these findings.


Assuntos
Síndrome das Pernas Inquietas , Distúrbios do Início e da Manutenção do Sono , Humanos , Estudos de Coortes , Estudo de Associação Genômica Ampla , Sono , Movimento , Síndrome das Pernas Inquietas/genética
20.
BMC Psychiatry ; 22(1): 758, 2022 12 03.
Artigo em Inglês | MEDLINE | ID: mdl-36463186

RESUMO

BACKGROUND: Sleep spindles have been involved in sleep stabilization and sleep-related memory mechanisms and their deficit emerged as possible biomarker in schizophrenia. However, whether this sleep phenotype is also present in other disorders that share psychotic symptoms remains unclear. To address this gap, we assessed sleep spindles in participants of a prospective population-based cohort who underwent psychiatric assessment (CoLaus|PsyCoLaus) and polysomnographic recording (HypnoLaus). METHODS: Sleep was recorded using ambulatory polysomnography in participants (N = 1037) to the PsyCoLaus study. Sleep spindle parameters were measured in people with a lifelong diagnosis of schizophrenia (SZ), schizoaffective depressive (SAD), schizoaffective manic (SAM), bipolar disorder type I (BP-I) and type II (BP-II). The associations between lifetime diagnostic status (independent variables, SZ, SAD, SAM, BPD-I, BPD-II, controls) and spindle parameters (dependent variables) including density, duration, frequency and maximum amplitude, for all (slow and fast), slow- and fast-spindle were assessed using linear mixed models. Pairwise comparisons of the different spindle parameters between the SZ group and each of the other psychiatric groups was performed using a contrast testing framework from our multiple linear mixed models. RESULTS: Our results showed a deficit in the density and duration of sleep spindles in people with SZ. They also indicated that participants with a diagnosis of SAD, SAM, BP-I and BP-II exhibited different sleep spindle phenotypes. Interestingly, spindle densities and frequencies were different in people with a history of manic symptoms (SAM, BP-I, and BP-II) from those without (SZ, SAD). CONCLUSIONS: Although carried out on a very small number of participants due to the low prevalence of these disorders in general population, this pilot study brought new elements that argued in favor of a deficit of sleep spindles density and duration in people with schizophrenia. In addition, while we could expect a gradual change in intensity of the same sleep spindle parameters through psychotic diagnoses, our results seem to indicate a more complex situation in which the frequency of sleep spindles might be more impacted by diagnoses including a history of mania or hypomania. Further studies with a larger number of participants are required to confirm these effects.


Assuntos
Transtorno Bipolar , Transtornos Psicóticos , Esquizofrenia , Humanos , Transtorno Bipolar/complicações , Transtorno Bipolar/diagnóstico , Esquizofrenia/complicações , Esquizofrenia/diagnóstico , Projetos Piloto , Estudos Prospectivos , Transtornos Psicóticos/complicações , Transtornos Psicóticos/diagnóstico , Sono
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...