Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Bone Joint Res ; 7(6): 406-413, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30034794

RESUMO

OBJECTIVES: Little is known about tissue changes underlying bone marrow lesions (BMLs) in non-weight-bearing joints with osteoarthritis (OA). Our aim was to characterize BMLs in OA of the hand using dynamic histomorphometry. We therefore quantified bone turnover and angiogenesis in subchondral bone at the base of the thumb, and compared the findings with control bone from hip OA. METHODS: Patients with OA at the base of the thumb, or the hip, underwent preoperative MRI to assess BMLs, and tetracycline labelling to determine bone turnover. Three groups were compared: trapezium bones removed by trapeziectomy from patients with thumb base OA (n = 20); femoral heads with (n = 24); and those without (n = 9) BMLs obtained from patients with hip OA who underwent total hip arthroplasty. RESULTS: All trapezium bones demonstrated MRI-defined BMLs. Compared with femoral heads without BMLs, the trapezia demonstrated significantly higher bone turnover (mean sd 0.2 (0.1) versus 0.01 (0.01) µm3/µm2/day), mineralizing surface (18.5% (13.1) versus 1.4% (1.3)) and vascularity (5.2% (1.1) versus 1.2% (0.6)). Femoral heads with BMLs exhibited higher bone turnover (0.3 (0.2) versus 0.2 (0.1) µm3/µm2/day), a higher mineralization rate (26.6% (10.6) versus 18.6% (11.9)) and greater trabecular thickness (301.3 µm (108) versus 163.6 µm (24.8)) than the trapezia. CONCLUSION: Bone turnover and angiogenesis were enhanced in BMLs of both the thumb base and hip OA, of which the latter exhibited the highest bone turnover. Thus, the increase in bone turnover in weight-bearing joints like the hip may be more pronounced than less mechanically loaded osteoarthritic joints demonstrating BMLs. The histological changes observed may explain the water signal from BMLs on MRI.Cite this article: M. Shabestari, N. J. Kise, M. A. Landin, S. Sesseng, J. C. Hellund, J. E. Reseland, E. F. Eriksen, I. K. Haugen. Enhanced angiogenesis and increased bone turnover characterize bone marrow lesions in osteoarthritis at the base of the thumb. Bone Joint Res 2018;7:406-413. DOI: 10.1302/2046-3758.76.BJR-2017-0083.R3.

2.
Scand J Rheumatol ; 47(4): 325-330, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29239667

RESUMO

OBJECTIVES: This study compares the prevalence of radiological osteoarthritis (OA) in patients with type 1 diabetes mellitus (DM1) for > 45 years and controls, and explores the association with shoulder pain and glycaemic burden in patients with DM1. METHOD: The Dialong study is a cross-sectional, observational study with 30 years of historical data on long-term glycaemic control. We included 102 patients with DM1 and 73 diabetes-free controls. Demographic data, worst shoulder pain last week [numeric rating scale (NRS) 0-10], pain on abduction at examination (NRS 0-10), and current and historical glycosylated haemoglobin (HbA1c) levels were collected. Standardized shoulder X-rays were taken and interpreted for OA applying the Kellgren-Lawrence classification. RESULTS: In the diabetes group (49% women), the mean ± sd duration of DM1 was 50.6 ± 4.8 years, mean 30 year HbA1c 7.4%, and age 61.9 ± 7.1 years. The mean age of controls (57% women) was 62.6 ± 7.0 years. Radiological glenohumeral OA was found in 36 diabetes patients (35%) and 10 controls (14%) [odds ratio (OR) 3.4, 95% confidence interval (CI) 1.6 to 7.5; p = 0.002]. Few persons had moderate and severe OA [6.9% vs 1.3%, OR 5.3 (95% Cl 0.6 to 44.1); p = 0.1]. Fifteen diabetes patients had painful OA versus two controls (adjusted OR 5.4, 95% CI 0.6 to 47.9; p = 0.13). There was no association between OA and long-term glycaemic burden (mean 30 year HbA1c) in the diabetes group (p > 0.2). CONCLUSIONS: Radiological glenohumeral OA was more common in patients with DM1 than in controls for mild, but not moderate and severe OA. The radiological findings were not associated with shoulder pain or long-term glycaemic burden.


Assuntos
Diabetes Mellitus Tipo 1/epidemiologia , Osteoartrite/epidemiologia , Articulação do Ombro/diagnóstico por imagem , Idoso , Estudos de Casos e Controles , Estudos Transversais , Diabetes Mellitus Tipo 1/metabolismo , Feminino , Hemoglobinas Glicadas/metabolismo , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite/diagnóstico por imagem , Prevalência , Radiografia , Fatores de Tempo
3.
J Hand Surg Eur Vol ; 40(1): 76-83, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25427553

RESUMO

Current literature gives few guidelines regarding indication for operative treatment of little finger metacarpal neck fractures, and some surgeons choose operative treatment when the palmar angulation exceeds 30°. The objective of this study was to determine whether conservative treatment produces comparable outcomes with bouquet pinning in a randomized, controlled trial. Eighty-five patients with little finger metacarpal neck fractures with ≥30° palmar angulation in the lateral view were included. Patients were randomized to two groups: conservative treatment without reduction of the fracture (43 patients); and closed reduction and bouquet pinning (42 patients). After 1 year, there were no statistical differences between the groups in QuickDASH score, pain, satisfaction, finger range of motion, grip strength, or quality of life. There was a trend versus better satisfaction with hand appearance (p = 0.06), but longer sick leave (p < 0.001) and more complications (p = 0.02) in the operative group.


Assuntos
Pinos Ortopédicos , Moldes Cirúrgicos , Fixação Interna de Fraturas , Fraturas Ósseas/terapia , Ossos Metacarpais/lesões , Adolescente , Adulto , Idoso , Feminino , Seguimentos , Força da Mão , Humanos , Masculino , Pessoa de Meia-Idade , Amplitude de Movimento Articular , Recuperação de Função Fisiológica , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
4.
J Hand Surg Eur Vol ; 38(6): 658-66, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23060463

RESUMO

Four methods for measuring volar angulation in 5th metacarpal neck fractures were tested for validity and reliability. Mid-medullary canal measurement in the lateral view (method MC-90) has previously been proven valid in a cadaveric study, hence used as a reference to test validity of the latter three. These three yielded a significant different mean fracture angle compared with MC-90, with only minor enhancement in reliability. Therefore, none of these three methods is recommended as a better standard method than the MC-90, where reliability was found to be substantial (intraclass correlation coefficient 0.53-0.81). Two methods for measuring shortening in 5th metacarpal neck fractures were compared, and stipulation of shortening by drawing a line through the most distal point of the heads of the neighbouring 3rd and 4th metacarpals (method SH-Stip) is a simple method with excellent reliability (intraclass correlation coefficient 0.81-0.96) for estimating shortening, requiring only radiological examination of the injured hand.


Assuntos
Fraturas Ósseas/diagnóstico por imagem , Ossos Metacarpais/diagnóstico por imagem , Ossos Metacarpais/lesões , Humanos , Modelos Lineares , Variações Dependentes do Observador , Interpretação de Imagem Radiográfica Assistida por Computador , Reprodutibilidade dos Testes
5.
J Hand Surg Eur Vol ; 37(5): 387-95, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22170245

RESUMO

Although extra-articular metacarpal fractures are common, there is no consensus on the mode of treatment. We evaluated the outcome in 67 patients operated for isolated, extra-articular fractures in the neck or shaft of the ulnar two metacarpals 28 months post-operatively. There were 22 bouquet (intra-medullary) pinnings and 45 transverse pinnings; 11 were lost to follow-up. Overall, hand function was good, and no difference was detected between the two methods (QuickDASH, grip strength, range of motion, VAS pain and VAS satisfaction). Many patients suffered complications: 12% had a superficial infection (all treated with transverse pinning with wires left exposed); 39% had some impairment in skin sensation; 29% reported cold intolerance; and 10% had other complications. Due to the potential risk of a secondary fracture of the neighbouring metacarpal after transverse pinning, we recommend bouquet (intra-medullary) pinning. We also recommend burying wires beneath the skin surface to avoid infection.


Assuntos
Fixação Interna de Fraturas/métodos , Fraturas Ósseas/cirurgia , Ossos Metacarpais/lesões , Adulto , Pinos Ortopédicos , Feminino , Fixação Intramedular de Fraturas , Fraturas Ósseas/diagnóstico por imagem , Traumatismos da Mão/cirurgia , Força da Mão , Humanos , Masculino , Ossos Metacarpais/cirurgia , Medição da Dor , Radiografia , Amplitude de Movimento Articular , Adulto Jovem
6.
Acta Radiol ; 48(9): 943-7, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17957507

RESUMO

BACKGROUND: Magnetic resonance cholangiopancreaticography (MRCP) is commonly used to evaluate the pancreatic (PD) and common bile duct (CBD), and the addition of secretin is used to obtain functional information (S-MRCP). Neither method gives any information on flow velocities within the ducts. PURPOSE: To evaluate a new, MRI diffusion-based, slow-flow-sensitive sequence for the detection of slow flow changes in the PD and CBD. MATERIAL AND METHODS: Seven healthy volunteers were examined. A modified single-shot turbo spin-echo sequence was used to detect slow flow changes. Three b factors (0, 6, and 12 s/mm(2)) were used. The flow sensitivity was applied in two directions, vertically and horizontally. Scanning was performed before and after glucagon was given, and again after an intravenous injection of secretin. The sequence gives signal loss from a duct when flow increases, and such changes were recorded. RESULTS: All images showed the PD with b = 0 (no flow sensitization). After administration of glucagon, artifacts from bowel movements were reduced and visibility of the PD was improved at both b = 6 and b = 12. Significant reduction of the visibility of the PD, indicating increased flow, was recorded both at b = 6 and b = 12 after the administration of secretin. There were no changes in the visibility of the CBD. CONCLUSION: This study shows that MRI-based detection of slow flow changes inside the PD is possible. Due to the sequence's high sensitivity to any motion, further studies are required before adopting the method for clinical use.


Assuntos
Ductos Biliares/fisiologia , Colangiopancreatografia por Ressonância Magnética , Ductos Pancreáticos/fisiologia , Adulto , Artefatos , Feminino , Glucagon , Humanos , Aumento da Imagem/métodos , Masculino , Secretina , Sensibilidade e Especificidade
7.
Acta Radiol ; 48(2): 135-41, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17354131

RESUMO

PURPOSE: To explore the usefulness of secretin-stimulated magnetic resonance cholangiopancreatography (S-MRCP) on different pathological entities in the pancreaticobiliary tract (PBT) MATERIAL AND METHODS: Sixty-two patients with unclear disease in the PBT were examined with S-MRCP as the final radiological procedure. Nine groups of referral diagnoses were identified, and clinical outcome was evaluated. RESULTS: In five patients with suspected pancreatic duct injury after blunt abdominal trauma, a negative predictive value of 100% was found after a median of 3.5 months of follow-up. In 22 patients with residual pain after cholecystectomy, investigated for sphincter of Oddi dysfunction (SOD), delayed dilatation of the PD and pain were documented in four patients. Three of these were treated with endoscopic papillotomy (EPT), and no recurrences were found during an average of 13.6 months of follow-up. Five cases of pancreas divisum not previously seen were identified, and of 12 patients with suspected postoperative stenosis, five were successfully treated after being identified with S-MRCP. Useful information was obtained in most of the patients, i.e., findings not observed in previous radiological examinations or clarifying uncertain previous findings. Nine patients were referred to other non-radiological examinations, identifying that the origin of disease was outside the PBT. CONCLUSION: S-MRCP has the potential to become the final part of diagnostic workup in difficult PBT diseases, but further investigation of usefulness regarding different referral reasons is mandatory.


Assuntos
Doenças dos Ductos Biliares/diagnóstico , Colangiopancreatografia por Ressonância Magnética , Pancreatopatias/diagnóstico , Secretina/administração & dosagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Ductos Biliares/lesões , Meios de Contraste/administração & dosagem , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pâncreas/lesões , Valor Preditivo dos Testes , Ferimentos não Penetrantes/diagnóstico
8.
MAGMA ; 17(2): 68-73, 2004 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-15340857

RESUMO

The purpose of this paper is to present a new pulse sequence for visualizing slow flow. The new sequence consists of an initial Stejskal-Tanner flow sensitization part followed by a DEFT pulse and a spoiler gradient. A single-shot TSE readout train is then applied to sample the NMR signal. The sequence was initially tested using a simple flow phantom. To verify potential clinical use, both flow-sensitive MRCP and cerebrospinal fluid (CSF) images were produced. The phantom study proved the sequence sensitivity to flow in the range 0-1 cm/s. bVE-factors 1.5, 3, 6 and 12 were chosen. Within this flow velocity range, the signal dropped as predicted theoretically. This indicates that the method can be used to quantify flow. All anatomical features seen in a standard MRCP sequence were identified and the methods sensitivity to CSF flow was demonstrated by sagital images of the head. A new pulse sequence sensitive to slow flow has been developed.


Assuntos
Ventrículos Cerebrais/anatomia & histologia , Ventrículos Cerebrais/fisiologia , Líquido Cefalorraquidiano/fisiologia , Imagem de Difusão por Ressonância Magnética/métodos , Aumento da Imagem/métodos , Reologia/métodos , Processamento de Sinais Assistido por Computador , Imagem de Difusão por Ressonância Magnética/instrumentação , Humanos , Imagens de Fantasmas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...