Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 104(1): 92-96, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38686525

RESUMO

The double-kiss mini-crush (DKMC) technique has been successfully deployed in the past for the treatment of complex coronary lesions even for left main lesions. Our case report consists of a proof-of-principle that the DKMC technique can be successfully translated as well to the field of complex renal artery lesions. Insightful thinking out-of-the "coronary" box in concert with skillful off-label application of coronary stenting procedures may open the gate for unprecedented opportunities for the treatment of difficult-to-tackle in-stent restenosis in the renal circulation.


Assuntos
Recidiva , Obstrução da Artéria Renal , Stents , Humanos , Obstrução da Artéria Renal/diagnóstico por imagem , Obstrução da Artéria Renal/terapia , Obstrução da Artéria Renal/fisiopatologia , Obstrução da Artéria Renal/etiologia , Resultado do Tratamento , Masculino , Angioplastia com Balão/instrumentação , Grau de Desobstrução Vascular , Idoso , Artéria Renal/diagnóstico por imagem , Artéria Renal/fisiopatologia
2.
Am J Cardiovasc Dis ; 12(1): 42-52, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35291508

RESUMO

BACKGROUND: This study aimed to assess the stability of pressure derived fractional flow reserve (FFR) measurement and the handling performance of the OptoWire Deux with an optical pressure sensor relative to the PressureWire X with piezo resistive pressure sensors. METHODS: This multicenter centre observational study included 50 patients between June 2017 and November 2018 undergoing a diagnostic coronary angiography with FFR measurement of moderate to severe lesions. The reliability of FFR measurement measured with the OptoWire Deux relative to the PressureWire X in each lesion was assessed by the presence of drift. Handling characteristics for both pressure wires were assessed by a 5-point scale and by comparing the time between equalization and crossing the distal target lesion. RESULTS: Hundred and sixteen measurements in 50 patients were performed. Very stable and reliable FFR measurements with the optical sensors were registered, relative to the piezo resistive pressure sensors. There is statistically significant difference in favor of the OptoWire Deux over the PressureWire X (P=0.001). However, the differences are small, when drift values were compared as continuous variables, no statistically significant difference was found for both directional (P=0.435) as for absolute drift (P=0.058). CONCLUSIONS: In patients undergoing FFR measurement, both optical sensor pressure wires (Optowire Deux) as piezo resistive sensor pressure wires (PressureWire X) generate stable and reliable pressure and thus FFR measurement. The optical pressure sensor is less susceptible for drift relative to the piezo resistive pressure sensor, but the difference is within an acceptable range.

3.
J Interv Cardiol ; 2021: 8042633, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34949966

RESUMO

BACKGROUND: The field of CTO PCI is expanding, but successful and safe percutaneous coronary intervention (PCI) of coronary chronic total occlusions (CTO) requires a substantial resource and experience investment. We aimed to assess temporal trends in strategies and outcomes of 2 dedicated programs for CTO PCI. METHODS: Between 2011 and 2020, 920 CTO PCI procedures were prospectively included at 2 referral centres in Belgium. Temporal trends were assessed, and logistic regression models were built to identify predictors of outcome. RESULTS: Despite an increase in lesion complexity (the J-CTO score increased from 1.3 in year 1 to 1.7-2.0 in years 8-9, p < 0.001), technical success improved from 70.0% to 85.6% in year 9 (p value for trend <0.001). We observed the most significant improvement starting at years 3-4 (OR 2.3 in year 4 versus year 1, p=0.018). Together with an increase in success rates and lesions complexity, there was an increase in the use of dual injections, retrograde approaches, the number of balloons and stents, and the use of microcatheters. Conversely, there was a decrease in large bore access, an increase in radial approach, and a shift towards contemporary dissection/reentry techniques. This strategy resulted in a stable major complication rate of 4.7% (p value for trend 0.33). The rate of coronary procedure-related myocardial injury was high (71.0%) and was associated with the use of more intracoronary devices. CONCLUSIONS: Three to four years after initiation of a dedicated CTO PCI program with 50 CTO PCIs per year, consistent high technical success and low complication rates are achieved using contemporary strategies.


Assuntos
Oclusão Coronária , Intervenção Coronária Percutânea , Doença Crônica , Angiografia Coronária , Oclusão Coronária/cirurgia , Humanos , Estudos Prospectivos , Sistema de Registros , Fatores de Risco , Resultado do Tratamento
4.
Acta Cardiol ; 76(4): 353-358, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32138629

RESUMO

BACKGROUND: The impact of revascularisation of chronic total occlusions (CTO) on the incidence of ventricular arrhythmias (VA) remains to be elucidated. METHODS: Based on prospectively gathered data, the recurrence rate of VAs following CTO treatment was retrospectively investigated. Patients presenting with VAs as clinical indication for CTO revascularisation were retrospectively selected out of three Belgian CTO registries (i.e. Ziekenhuis Oost-Limburg, UZ Leuven and CHR de la Citadelle). Freedom of VAs was defined as absence of non-sustained or sustained tachycardias (VT), ventricular fibrillations (Vfib) and ventricular extrasystoles (VES; <2500 VES/24 h). Long-term outcome in terms of reoccurrence of VAs was evaluated by reviewing patient records. RESULTS: Between 2011 and 2019, 912 patients underwent a CTO-PCI across three Belgian centres. In total 43 patients (5%) presented with VAs as clinical indication for CTO revascularisation. Overall follow-up was 723 (391 - 1144) days. Fourteen (33%), 18 (42%), 5 (11%) and 6 (14%) presented with >2500 VES/24 hrs, non-sustained VT, sustained VT and Vfib, respectively. In those patients with a one-year follow-up available (n = 34), overall recurrence rate of VAs was 38% (within VA group: VES: 25%, non-sustained VT: 46%; sustained VT: 25% and Vfib: 60%). CONCLUSION: Based on this retrospective data analysis, CTO revascularisation, in patients presenting with VAs as the main clinical indication, seems to beneficially impact the incidence of VAs, which ultimately might result in improved patients' outcome.


Assuntos
Oclusão Coronária , Intervenção Coronária Percutânea , Taquicardia Ventricular , Arritmias Cardíacas/epidemiologia , Bélgica , Doença Crônica , Oclusão Coronária/diagnóstico , Oclusão Coronária/epidemiologia , Oclusão Coronária/cirurgia , Humanos , Recidiva , Estudos Retrospectivos , Fatores de Risco , Taquicardia Ventricular/epidemiologia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...