Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int J Radiat Oncol Biol Phys ; 65(3): 907-16, 2006 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-16751073

RESUMO

PURPOSE: To investigate the potential for intensity-modulated radiotherapy (IMRT) to spare the bowel in rectal tumors. METHODS AND MATERIALS: The targets (pelvic nodal and rectal volumes), bowel, and bladder were outlined in 5 patients. All had conventional, three-dimensional conformal RT and forward-planned multisegment three-field IMRT plans compared with inverse-planned simultaneous integrated boost nine-field equally spaced IMRT plans. Equally spaced seven-field and five-field and five-field, customized, segmented IMRT plans were also evaluated. RESULTS: Ninety-five percent of the prescribed dose covered at least 95% of both planning target volumes using all but the conventional plan (mean primary and pelvic planning target volume receiving 95% of the prescribed dose was 32.8 +/- 13.7 Gy and 23.7 +/- 4.87 Gy, respectively), reflecting a significant lack of coverage. The three-field forward planned IMRT plans reduced the volume of bowel irradiated to 45 Gy and 50 Gy by 26% +/- 16% and 42% +/- 27% compared with three-dimensional conformal RT. Additional reductions to 69 +/- 51 cm(3) to 45 Gy and 20 +/- 21 cm(3) to 50 Gy were obtained with the nine-field equally spaced IMRT plans-64% +/- 11% and 64% +/- 20% reductions compared with three-dimensional conformal RT. Reducing the number of beams and customizing the angles for the five-field equally spaced IMRT plan did not significantly reduce bowel sparing. CONCLUSION: The bowel volume irradiated to 45 Gy and 50 Gy was significantly reduced with IMRT, which could potentially lead to less bowel toxicity. Reducing the number of beams did not reduce bowel sparing and the five-field customized segmented IMRT plan is a reasonable technique to be tested in clinical trials.


Assuntos
Intestinos/efeitos da radiação , Lesões por Radiação/prevenção & controle , Radioterapia de Intensidade Modulada/métodos , Neoplasias Retais/radioterapia , Bexiga Urinária/efeitos da radiação , Humanos , Dosagem Radioterapêutica , Radioterapia Conformacional/métodos , Neoplasias Retais/patologia , Estudos Retrospectivos
2.
Radiother Oncol ; 78(3): 322-5, 2006 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16564591

RESUMO

The forward and inverse treatment plans of 10 patients with lung cancer were compared in terms of PTV coverage, sparing of normal lung and time required to generate a plan. The inverse planning produced as good treatment plans as an experienced dosimetrist with considerable reduction in staff time. When translated to other complex sites, inverse non-IMRT planning may have considerable impact on manpower requirements.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/radioterapia , Imageamento Tridimensional/métodos , Neoplasias Pulmonares/radioterapia , Modelos Biológicos , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Algoritmos , Carga Corporal (Radioterapia) , Carcinoma Pulmonar de Células não Pequenas/fisiopatologia , Simulação por Computador , Humanos , Neoplasias Pulmonares/fisiopatologia , Dosagem Radioterapêutica , Eficiência Biológica Relativa , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
Radiother Oncol ; 75(3): 287-92, 2005 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15885830

RESUMO

BACKGROUND AND PURPOSE: To evaluate the benefit of using non-coplanar treatment plans for irradiation of two different clinical treatment volumes: prostate only (PO) and the prostate plus seminal vesicles (PSV). MATERIAL AND METHODS: An inverse planning algorithm was used to produce three-field, four-field, five-field and six-field non-coplanar treatment plans without intensity-modulation in ten patients. These were compared against a three-field coplanar plan. A dose of 74 Gy was prescribed to the isocentre. Plans were compared using the minimum dose to the planning target volume (PTV), maximum dose to the small bowel, and irradiated volumes of rectum, bladder and femoral head. Biological indices were also evaluated. RESULTS: For the PO group, volume of rectum irradiated to 60 Gy (V(60)) was 22.5+/-3.7% for the coplanar plan, and 21.5+/-5.3% for the five-field non-coplanar plan, which was the most beneficial (p=0.3). For the PSV group, the five-field non-coplanar plan was again the most beneficial. Rectal V(60) was in this case reduced from 41.5+/-10.4% for the coplanar plan to 35.2+/-9.3% for the non-coplanar plan (p=0.02). CONCLUSIONS: The use of non-coplanar beams in conformal prostate radiotherapy provides a small increase in rectal sparing, more significantly with PSV volumes than for PO volumes.


Assuntos
Neoplasias da Próstata/radioterapia , Planejamento da Radioterapia Assistida por Computador , Radioterapia Conformacional/métodos , Idoso , Humanos , Masculino , Pessoa de Meia-Idade , Radioterapia Conformacional/efeitos adversos , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...