1.
BMC Anesthesiol ; 19(1): 240, 2019 12 27.
Artigo em Inglês | MEDLINE | ID: mdl-31881989

RESUMO

BACKGROUND: Point-of-care (POC) hemoglobin testing has the potential to revolutionize massive transfusion strategies. No prior studies have compared POC and central laboratory testing of hemoglobin in patients undergoing massive transfusions. METHODS: We retrospectively compared the results of our point-of-care hemoglobin test (EPOC®) to our core laboratory complete blood count (CBC) hemoglobin test (Sysmex XE-5000™) in patients undergoing massive transfusion protocols (MTP) for hemorrhage. One hundred seventy paired samples from 90 patients for whom MTP was activated were collected at a single, tertiary care hospital between 10/2011 and 10/2017. Patients had both an EPOC® and CBC hemoglobin performed within 30 min of each other during the MTP. We assessed the accuracy of EPOC® hemoglobin testing using two variables: interchangeability and clinically significant differences from the CBC. The Clinical Laboratory Improvement Amendments (CLIA) proficiency testing criteria defined interchangeability for measurements. Clinically significant differences between the tests were defined by an expert panel. We examined whether these relationships changed as a function of the hemoglobin measured by the EPOC® and specific patient characteristics. RESULTS: Fifty one percent (86 of 170) of paired samples' hemoglobin results had an absolute difference of ≤7 and 73% (124 of 170) fell within ±1 g/dL of each other. The mean difference between EPOC® and CBC hemoglobin had a bias of - 0.268 g/dL (p = 0.002). When the EPOC® hemoglobin was < 7 g/dL, 30% of the hemoglobin values were within ±7, and 57% were within ±1 g/dL. When the measured EPOC® hemoglobin was ≥7 g/dL, 55% of the EPOC® and CBC hemoglobin values were within ±7, and 76% were within ±1 g/dL. EPOC® and CBC hemoglobin values that were within ±1 g/dL varied by patient population: 77% for cardiac surgery, 58% for general surgery, and 72% for non-surgical patients. CONCLUSIONS: The EPOC® device had minor negative bias, was not interchangeable with the CBC hemoglobin, and was less reliable when the EPOC® value was < 7 g/dL. Clinicians must consider speed versus accuracy, and should check a CBC within 30 min as confirmation when the EPOC® hemoglobin is < 7 g/dL until further prospective trials are performed in this population.


Assuntos
Transfusão de Sangue/métodos , Hemoglobinas/análise , Sistemas Automatizados de Assistência Junto ao Leito , Técnicas de Laboratório Clínico , Hemorragia/terapia , Humanos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores de Tempo
2.
Crit Care Clin ; 33(4): 795-811, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28887928

RESUMO

Pulmonary and critical care physicians must be facile in recognition and management of patients with acute respiratory distress syndrome (ARDS). Part of the current critical care knowledge base must include an understanding of how extracorporeal membrane oxygenation fits into the paradigm of ARDS management without using it as a "salvage therapy." This article provides a basic understanding of the evolution of ARDS to multiple organ dysfunction syndrome, recognizing benefits and limits of rescue therapies, indications and contraindications of extracorporeal membrane oxygenation, and coordination of care for severe respiratory failure.


Assuntos
Oxigenação por Membrana Extracorpórea/métodos , Insuficiência de Múltiplos Órgãos/terapia , Síndrome do Desconforto Respiratório/terapia , Insuficiência Respiratória/terapia , Cuidados Críticos , Humanos , Terapia de Salvação/métodos
4.
Pancreatology ; 16(2): 278-83, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26774205

RESUMO

BACKGROUND AND STUDY AIMS: Pancreatic duct (PD) disruptions occur as a result of different etiologies and can be managed medically, endoscopically, or surgically. The aim of this study was to provide an evaluation on the efficacy of endotherapy for treatment of PD disruption in a large cohort of patients and identify factors that predict successful treatment outcome. PATIENTS AND METHODS: We retrospectively evaluated consecutive patients who underwent endoscopic retrograde pancreatography (ERP) for transpapillary pancreatic stent placement for PD disruption from 2008 to 2013 at two tertiary referral institutions. PD disruption was defined as extravasation of contrast from the pancreatic duct as seen on ERP. Therapeutic success was defined by resolution of PD leak on ERP, clinical, and/or imaging evaluation. RESULTS: We evaluated 107 patients (58% male, mean age 53 years) with PD disruption. Etiologies of PD disruption were acute pancreatitis (36%), post-operative (31%), chronic pancreatitis (29%), and trauma (4%). PD disruption was successfully bridged by a stent in 45 (44%) patients. Two patients developed post-sphincterotomy bleeding, two had stent migration, and two patients died as a result of post-ERP related complications. Placement of a PD stent was successful in 103/107 (96%) patients. Therapeutic success was achieved in 80/107 (75%) patients. Non-acute pancreatitis etiologies and absence of complete duct disruption were independent predictors of therapeutic success. CONCLUSIONS: Endoscopic therapy using a transpapillary stent for PD disruption is safe and effective. Absence of complete duct disruption and non-AP etiologies determine a favorable endoscopic outcome.


Assuntos
Endoscopia Gastrointestinal/métodos , Ductos Pancreáticos/lesões , Ductos Pancreáticos/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pancreatite/complicações , Ferimentos e Lesões/complicações
SELEÇÃO DE REFERÊNCIAS