Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Infect Control Hosp Epidemiol ; 41(1): 120-123, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31694732

RESUMO

In a crossover study, 30 stethoscopes were assessed and disinfected using 3 protocols: isopropyl alcohol, a quaternary ammonia or biguanide disinfectant, and ultraviolet germicidal irradiation (UVGI). All protocols effectively reduced bacterial loads, but UVGI was less effective at higher contamination levels (P = .0004). The effectiveness of each intervention was short in duration.


Assuntos
Infecção Hospitalar/prevenção & controle , Desinfecção/métodos , Estetoscópios/microbiologia , 2-Propanol , Amônia , Animais , Bactérias/classificação , Bactérias/efeitos dos fármacos , Bactérias/isolamento & purificação , Contagem de Colônia Microbiana , Estudos Cross-Over , Contaminação de Equipamentos/prevenção & controle , Hospitais Veterinários , Humanos , Estudos Prospectivos , Raios Ultravioleta , Reino Unido
2.
Vet Immunol Immunopathol ; 148(3-4): 267-75, 2012 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-22682231

RESUMO

The purpose of this study was to evaluate the reproducibility of results yielded using a monoclonal antibody based ELISA for detection of allergen specific IgE when run in six separate affiliated laboratories. On two separate occasions, duplicate samples of 15 different sera pools were independently evaluated by each laboratory in a single blinded fashion. The average intra-assay variance among reactive assay calibrators in all laboratories was 6.2% (range 2.6-18.2%), while the average intra-laboratory inter-assay variance was 12.1% (range 8.0-17.1%). The overall inter-assay inter-laboratory variance was consistent among laboratories and averaged 15.6% (range 15.1-16.6%). All laboratories yielded similar profiles and magnitudes of responses for replicate unknown samples; dose-response profiles observed in each of the laboratories were indistinguishable. Considering positive/negative results, inter-assay inter-laboratory concordance of results exceeded 95%. Correlation of OD values between and among all laboratories was strong (r>0.9, p<0.001). Correlation of OD values between the two separate evaluations was also high for all allergens except olive, which was attributed to lot-to-lot differences of allergen coated wells. Collectively, the results demonstrated that the monoclonal antibody based ELISA for measuring allergen specific canine IgE is reproducible, and documents that consistency of results can be achieved not only in an individual laboratory, but between laboratories using the same monoclonal-based ELISA.


Assuntos
Anticorpos Monoclonais , Ensaio de Imunoadsorção Enzimática/veterinária , Imunoglobulina E/imunologia , Alérgenos/imunologia , Animais , Doenças do Cão/sangue , Doenças do Cão/imunologia , Cães/sangue , Cães/imunologia , Relação Dose-Resposta Imunológica , Ensaio de Imunoadsorção Enzimática/métodos , Hipersensibilidade/sangue , Hipersensibilidade/imunologia , Hipersensibilidade/veterinária , Imunoglobulina E/sangue , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...