Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ophthalmic Epidemiol ; : 1-18, 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38635869

RESUMO

PURPOSE: Strabismus is more frequent in cerebral palsy (CP) than in the normal population, but reports differ how much it is increased. We here examined the global prevalence and types of strabismus in CP, whether esotropia or exotropia is more frequent, and whether the prevalence differs between ethnicities and/or country income levels, and between generations. METHODS: We compiled in a systematic review and meta-analysis the results of 147 CP studies that report the prevalence of strabismus or the ratio of esotropia to exotropia, and we conducted subgroup analyses for region (income level) and ethnicity. We performed a pooled analysis for the CP strabismus prevalence, and estimated the global number of CP cases with strabismus. RESULTS: The pooled prevalence of strabismus in CP is 49.8% in high-income countries and 39.8% in lower-income countries. We estimate the global number of strabismus cases in CP as 12.2 million, with 7.6 million males and 4.6 million females, based on current estimates of 29.6 million global CP cases. Esotropia is more frequent than exotropia in Caucasians, while exotropia is more frequent than esotropia in Hispanic and in some Asian and African populations. The strabismus prevalence in CP increases with increasing country income levels. CONCLUSION: Generational changes in strabismus prevalence appear to reflect a transition of CP types and an increase in prevalence as countries attain higher income and more effective maternal health care. The distribution of esotropia and exotropia in CP patients largely reflects the horizontal strabismus type that is predominant in the subject's ethnicity.

2.
Cornea ; 43(8): 950-954, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38561842

RESUMO

PURPOSE: The purpose of this study was to compare changes in the posterior curvature and the posterior-anterior radii ratio of the cornea, 1 year postoperatively in laser in situ keratomileusis (LASIK), photorefractive keratectomy (PRK), and small incision lenticule extraction (SMILE). METHODS: This retrospective study was performed at a single surgical center. 199 eyes were included in the study from 119 patients with manifest refraction spherical equivalents from -7.61 to -2.54 D. 67 eyes underwent LASIK, 89 underwent PRK, and 43 underwent SMILE. Both preoperative and 1-year postoperative front and back sagittal keratometry were measured at 4- to 6-mm zones around the corneal vertex. Corneal asphericity (Q-value) was measured at an 8-mm zone around the corneal vertex. RESULTS: The average change in the posterior-anterior radii ratio after LASIK, PRK, and SMILE did not differ between surgery groups at 4 mm (LASIK: -0.075, PRK: -0.073, SMILE: -0.072, P = 0.720), 5 mm (LASIK: -0.072, PRK: -0.068, SMILE: -0.068, P = 0.531), or 6 mm (LASIK: -0.075, PRK: -0.071, SMILE: -0.072, P = 0.456) zones. Anterior Q-value significantly positively increased after all 3 surgeries ( P < 0.001). The posterior Q-value also significantly positively increased after LASIK ( P < 0.001) and SMILE ( P < 0.001), but not after PRK ( P = 0.227). Both anterior and posterior keratometric power decreased significantly after LASIK, PRK, and SMILE for all diameters. CONCLUSIONS: The change in the posterior-anterior radii ratio was not influenced by the type of refractive surgery performed, as indicated by statistically identical preoperative, postoperative, and delta values. In addition, the posterior cornea exhibited paracentral flattening after LASIK, SMILE, and PRK and increased oblateness after LASIK and SMILE.


Assuntos
Córnea , Topografia da Córnea , Ceratomileuse Assistida por Excimer Laser In Situ , Lasers de Excimer , Miopia , Ceratectomia Fotorrefrativa , Refração Ocular , Acuidade Visual , Humanos , Miopia/cirurgia , Miopia/fisiopatologia , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Estudos Retrospectivos , Ceratectomia Fotorrefrativa/métodos , Adulto , Feminino , Masculino , Refração Ocular/fisiologia , Acuidade Visual/fisiologia , Lasers de Excimer/uso terapêutico , Córnea/cirurgia , Córnea/patologia , Adulto Jovem , Cirurgia da Córnea a Laser/métodos , Substância Própria/cirurgia , Substância Própria/patologia , Seguimentos , Período Pós-Operatório
3.
Clin Ophthalmol ; 18: 377-392, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38343904

RESUMO

Purpose: We assess the relationship between preoperative myopic sphere, astigmatism, and spherical equivalent and effective optical zone (EOZ) size, shape, and decentration within individual populations of post-LASIK, PRK, and SMILE patients. Patients and Methods: A retrospective chart review was conducted with 118 LASIK, 144 PRK, and 41 SMILE eyes from 179 total patients that underwent compound myopic ablation. One-year postoperative Pentacam tangential difference maps were used for EOZ data measurements. Correlational analysis between compound myopic measures [sphere, cylinder, manifest refractive spherical equivalent (MRSE)] and EOZ parameters was performed, and differences between groups of myopic sphere and cylinder within each surgery type were assessed. Results: An increase in absolute myopic sphere (and subsequent MRSE) is associated with a smaller EOZ area in SMILE (r=0.454, p=0.003) and a more circular EOZ shape in LASIK (r=0.396, p<0.001) and PRK (r=0.563, p<0.001). An increase in absolute myopic cylinder is associated with an increased EOZ area in all three surgery types [LASIK (r=-0.459, p<0.001), PRK (r=-0.716, p<0.001), SMILE (r=-0.429, p=0.005)] and a more elliptical EOZ in LASIK (r=-0.491, p<0.001) and PRK (r=-0.538, p<0.001). Conclusion: While astigmatism may be correlated to EOZ size within all three refractive surgery types, myopic sphere alone is insufficient to estimate EOZ size differences for procedures with a large blend zone of ablation like LASIK or PRK. Shape is just as important a factor as size to consider when examining corneal EOZ differences; reported correlative findings likely result from inherent differences in surgical technique and abruptness of planned surgical ablation borders.

4.
medRxiv ; 2024 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-38343841

RESUMO

Purpose: Strabismus is more frequent in cerebral palsy (CP) than in the normal population, but reports differ how much it is increased. We here examined the global prevalence and types of strabismus in CP, whether esotropia or exotropia is more frequent, and whether the prevalence differs between ethnicities and/or country income levels, and between generations. Methods: We compiled in a systematic review and meta-analysis the results of 147 CP studies that report the prevalence of strabismus or the ratio of esotropia to exotropia, and we conducted subgroup analyses for region (income level) and ethnicity. We performed a pooled analysis for the CP strabismus prevalence, and estimated the global number of CP cases with strabismus. Results: The pooled prevalence of strabismus in CP is 49.8% in high-income countries and 39.8% in lower-income countries. We estimate the global number of strabismus cases in CP as 12.2 million, with 7.6 million males and 4.6 million females, based on current estimates of 29.6 million global CP cases. Esotropia is more frequent than exotropia in Caucasians, while exotropia is more frequent than esotropia in Hispanic and in some Asian and African populations. The strabismus prevalence in CP increases with increasing country income levels. Conclusion: Generational changes in strabismus prevalence appear to reflect a transition of CP types and an increase in prevalence as countries attain higher income and more effective maternal health care. The distribution of esotropia and exotropia in CP patients largely reflects the horizontal strabismus type that is predominant in the subject's ethnicity.

5.
J Refract Surg ; 39(11): 741-750, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37937754

RESUMO

PURPOSE: To explore size, decentration, and eccentricity of effective optical zones (EOZs) in laser in situ keratomileusis (LASIK), photorefractive keratectomy (PRK), and small incision lenticule extraction (SMILE) and correlate them to higher order aberrations (HOAs). METHODS: This was a retrospective chart review of 188 eyes that underwent refractive surgery for compound myopia (61 LASIK, 84 PRK, 43 SMILE). EOZ measurements were determined using 1-year postoperative Pentacam (Oculus Optikgeräte GmbH) tangential difference maps. HOA data were measured using Pentacam wavefront aberration Zernike polynomials. Correlations between EOZs and HOAs were analyzed. RESULTS: The EOZs of LASIK and PRK are smaller than SMILE at 19.54 ± 1.44, 19.39 ± 1.66, and 22.18 ± 2.61 mm2, respectively (P < .001). No difference existed in absolute decentration from corneal vertex (P = .078) or pupil center (P = .131), but horizontal and vertical components differed significantly (P < .001). Smaller EOZ areas were correlated with greater spherical aberration induction (rLASIK = -0.378, rPRK = -0.555, rSMILE = -0.501) and total HOA induction in all groups. Absolute decentration from corneal vertex positively correlated with total HOA (rLASIK = 0.396, rPRK = 0.463, rSMILE = 0.399) and directional vertical coma induction negatively correlated with vertical decentration from the corneal vertex (rLASIK = -0.776, rPRK = -0.665, rSMILE = -0.576) in all groups. CONCLUSIONS: SMILE results in a larger EOZ than LASIK and PRK, and absolute decentration remains comparable regardless of surgical reference center, despite horizontal/vertical differences. Surgical planning to ensure adequate EOZ size and centration may reduce induction of HOAs, including spherical aberrations and vertical coma. [J Refract Surg. 2023;39(11):741-750.].


Assuntos
Aberrações de Frente de Onda da Córnea , Ceratomileuse Assistida por Excimer Laser In Situ , Miopia , Ceratectomia Fotorrefrativa , Humanos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Acuidade Visual , Estudos Retrospectivos , Coma/cirurgia , Topografia da Córnea , Aberrações de Frente de Onda da Córnea/cirurgia , Lasers de Excimer/uso terapêutico , Miopia/cirurgia
6.
J Clin Med ; 12(13)2023 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-37445571

RESUMO

The ratio of posterior-to-anterior curvature radii of the cornea (P/A ratio) is an important element in determining corneal refractive power. P/A ratio has been well studied in patients prior to undergoing refractive surgery, but its postoperative value remains less so. We aimed to examine the value of preoperative characteristics of refractive surgery patients in predicting the 1-year postoperative P/A ratio in LASIK, PRK, and SMILE using both linear and multivariate regression analyses. This was a retrospective study that included patients with manifest refraction spherical equivalents (MRSE) from -7.71D to -0.25D. In total, 164 eyes underwent LASIK, 183 underwent PRK, and 46 underwent SMILE. All patients had preoperative and 1-year postoperative front sagittal and back sagittal keratometry measurements at 4, 5, and 6 mm around the corneal vertex. Postoperative P/A after LASIK, PRK, and SMILE was found to be significantly correlated with MRSE and preoperative P/A. Stepwise variable selection in multivariate regression revealed that spherical equivalent was the most significant predictor of postoperative P/A. When coupled with other preoperative characteristics, including P/A, age, asphericity, and keratometry, the multivariate regressions were able to produce models with high predictive value in LASIK (adjusted R2: 0.957), PRK (adjusted R2: 0.934), and SMILE (adjusted R2: 0.894).

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...