Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Imaging ; 30(4): 248-53, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16814140

RESUMO

PURPOSE: Retrospectively, magnetic resonance (MR) colonography images obtained from a colon model and in routine examinations of patients screened for polyps were compared in terms of whether, and to what degree, image quality improved at a higher field strength of 3.0 T compared to 1.5 T. MATERIALS AND METHODS: One hundred twenty-eight MR colonography images from 40 patients, of whom 20 had each been scanned at 1.5 and 3.0 T, respectively, using a four-element phased-array torso coil, were compared. At both field strengths, imaging included T1-weighted fat-suppressed spoiled gradient-echo (T1-fs-GE), T2/T1-weighted fast imaging employing steady-state acquisition (FIESTA), and T2-weighted single-shot fast spin-echo (T2-SSFSE), with breath-hold technique. Using receiver operating characteristic analysis performed by seven readers, the three types of images from the colon model and from 20 patients each at 1.5 and 3.0 T were compared. While a time window of 20 s was allowed for picture assessment in a chance-generated succession of images on a monitor, image quality was rated with a score of 1-5 (1=very good; 5=very bad). Statistical significance was calculated with Mann-Whitney U test. RESULTS: At both field strengths, T2-SSFSE images received the best ratings, followed by FIESTA images (P=.001). Although, overall, the 3.0-T images obtained scores worse than those of the 1.5-T images, a better detection of phantom polyps was noted in the colon model (P=.001). CONCLUSION: Although MR colonography with the breath-hold technique using the same four-element phased-array coil at 3.0 and 1.5 T does not perform better at a higher field strength in general, an improved detection of small polyps may be obtained.


Assuntos
Colo/patologia , Pólipos do Colo/diagnóstico , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Colonoscopia/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Doses de Radiação , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
2.
Clin Imaging ; 30(1): 27-31, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16377481

RESUMO

BACKGROUND: This study focuses on the correlation of the signal intensity (SI) of the bowel wall in magnetic resonance (MR) colonography with the inflammation activity in Crohn's disease. MATERIAL AND METHODS: We performed MR colonography in 42 patients and compared the change of the SI of the bowel wall (T1-weighted/paramagnetic contrast medium) with colonoscopic findings. RESULTS: Change of the SI and colonoscopically assessed inflammatory activity are significantly correlated (r=.676, P

Assuntos
Colo/patologia , Doença de Crohn/patologia , Imageamento por Ressonância Magnética , Adulto , Colo/fisiopatologia , Colonoscopia , Meios de Contraste , Doença de Crohn/fisiopatologia , Feminino , Humanos , Aumento da Imagem , Inflamação/patologia , Masculino , Pessoa de Meia-Idade
4.
Stroke ; 34(6): 1382-8, 2003 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12750537

RESUMO

BACKGROUND AND PURPOSE: We sought (1) to identify early metabolic markers for the development of (ir)reversible neurological deficits and cerebral infarction in subarachnoid hemorrhage (SAH) patients by using the microdialysis technique and (2) to evaluate the influence of intracerebral hemorrhage (ICH) on microdialysis parameters. METHODS: We performed a prospective study of 44 SAH patients with acute focal neurological deficits (AFND) occurring acutely with SAH (due to ICH) or directly after surgery (due to clip stenosis, thromboembolism, or early edema). Fifty-one nonischemic SAH patients served as a control group. A microdialysis catheter was inserted into the vascular territory of the aneurysm after clipping. The microdialysates were analyzed hourly for extracellular glucose, lactate, lactate/pyruvate ratio, glutamate, and glycerol with a bedside analyzer. Microdialysis-related CT findings were evaluated for the presence of ICH and cerebral infarction. Reversibility of neurological symptoms after 4 weeks and 6- and 12-month outcomes were assessed. RESULTS: In patients with AFND, cerebral metabolism was severely disturbed when microdialysis started compared with controls (P<0.005). Infarction on CT was associated with pathological microdialysis parameters (P<0.002) and development of a fixed deficit (P<0.003), while the presence of ICH alone was not. A secondary neurological deterioration of AFND patients (n=11) was reflected by preceding (0 to 20 hours) changes of microdialysate concentrations. CONCLUSIONS: In the presence of ICH, pathological microdialysis values may indicate reversible tissue damage. Extreme microdialysis values and pathological microdialysis concentrations that further deteriorate 2-fold are highly indicative of the development of cerebral infarction and permanent neurological deficits. Therefore, the analysis of relative changes of microdialysis parameters is crucial for the detection of ischemia in SAH patients.


Assuntos
Doenças do Sistema Nervoso/diagnóstico , Doenças do Sistema Nervoso/fisiopatologia , Hemorragia Subaracnóidea/diagnóstico , Hemorragia Subaracnóidea/fisiopatologia , Doença Aguda , Biomarcadores/análise , Encéfalo/irrigação sanguínea , Encéfalo/diagnóstico por imagem , Encéfalo/fisiopatologia , Angiografia Cerebral , Demografia , Progressão da Doença , Feminino , Glucose/análise , Ácido Glutâmico/análise , Glicerol/análise , Humanos , Lactose/análise , Masculino , Microdiálise , Pessoa de Meia-Idade , Monitorização Fisiológica , Doenças do Sistema Nervoso/complicações , Paresia/etiologia , Valor Preditivo dos Testes , Estudos Prospectivos , Hemorragia Subaracnóidea/complicações , Tomografia Computadorizada por Raios X , Vasoespasmo Intracraniano/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...