Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 55
Filtrar
1.
Plast Reconstr Surg Glob Open ; 12(7): e5985, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39022529

RESUMO

Prior studies on contrast-enhanced ultrasound (CEUS) lymphography for preoperative mapping before lymphaticovenous anastomosis surgery in patients with extremity lymphedema have been limited to using only Lumason and Sonazoid as microbubble contrast agents. The purpose of this study was to determine the feasibility of using two other Food & Drug Administration-approved microbubble agents, Optison and Definity, for imaging lymphatic vessels in the upper extremities. Nine female adults with unilateral upper extremity lymphedema anticipating lymphaticovenous anastomosis surgery underwent CEUS lymphography of the unaffected upper extremity randomized to either Lumason, Definity, or Optison. Lymphatic vessels were visualized in all but one case when undilated Definity was used. In the eight upper extremities where lymphatic vessels were visualized, an average of eight intradermal injections of microbubbles were performed in the extremity. Lymphatic vessels could be identified in 57% (36 of 63) of the injections. The effective dilution for each of the microbubble agents is provided. This was the first successful demonstration of lymphatic vessel visualization using either Definity or Optison. Broadening the range of available microbubble agents for CEUS lymphography could improve accessibility to the procedure and provide potentially safer alternatives.

2.
Ultrasound Med Biol ; 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38849280

RESUMO

OBJECTIVE: Ultrasound beams sometimes need to be steered from the edge of linear array transducers to reach the sample volume with a desired Doppler angle in vascular exams. This phantom study aims to evaluate the impact of apertures located at the array edge on peak velocity (PV) measurements. METHODS: Three ultrasound scanner systems equipped with eight transducers from 3 major ultrasound vendors were tested using a flow phantom with a horizontal tube. Five spectral Doppler measurements with the aperture positioned at one edge of the array and 5 with the aperture at the center of the array were obtained using all available scanner-transducer combinations while maintaining all scan parameters and the sample volume in the same tube location. Differences in PVs between center and edge apertures were compared across 4 constant flow rates. RESULTS: The averaged PVs for all phantom flow rates ranged from 24.4 cm/s to 138.2 cm/s from the array center. The averaged PVs from the center aperture were significantly greater than the corresponding measurements from the edge aperture for each flow rate (all p < 0.001). The relative PV differences ranged from 6.7% to 19.4% across all transducers and flow rates. CONCLUSION: Significantly lower PVs were consistently shown with the Doppler beam aperture at the array edge compared to center among all tested systems. This may be due to a narrower aperture width, shifted central axis, and less intrinsic spectral broadening error at the array edge. Controlling variations in Doppler aperture location is important in clinical applications which depend on consistent velocity measurements.

3.
Plast Reconstr Surg Glob Open ; 12(6): e5908, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38911583

RESUMO

Lymphedema following oncologic intervention can cause significant lifelong morbidity for patients in whom conservative management fails. The associated swelling, discomfort, pain, and recurrent cellulitis greatly diminish quality of life. Surgical procedures, including suction-assisted lipectomy, lymphovenous anastomosis (LVA), and vascularized lymph node transfers, show effectiveness in both volume reduction in affected extremities and symptom relief. However, the success of procedures like LVA is dependent on effective preoperative lymphatic mapping to identify suitable vessels for anastomosis. Traditional superficial lymphatic mapping uses near infrared fluorescence indocyanine green (ICG) imaging. Moreover, recent advances in contrast-enhanced ultrasound (CEUS) lymphography increased lymphovenous bypass target identification for LVA in the extremities.7 CEUS lymphography uses microbubbles as a contrast-enhancing agent injected intradermally into the affected extremity with subsequent identification of superficial collecting lymphatic vessels using ultrasound. Although a recent report noted an uptick in severe and critical adverse drug reactions to an ultrasound contrast agent injected intravenously in stress echocardiography, adverse drug reactions associated with ultrasound contrast-enhancing agents in body ultrasound are rare. The safety profile and potential complications from CEUS lymphography in the lymphedema population have yet to be fully characterized. In this case report, the authors present the first cutaneous adverse drug event following a secondary exposure to the contrast used for CEUS imaging. Mechanisms and justifications for an immune-mediated process are explored, and a review of similar manifestations in other related contrast applications is discussed.

4.
Ultrasound Med Biol ; 50(7): 1001-1009, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38575416

RESUMO

OBJECTIVE: We have studied the use of polymethyl methacrylate (PMMA) as an alternative biopsy marker that is readily detectable with ultrasound Doppler twinkling in cases of in vitro, ex vivo, or limited duration in vivo settings. This study investigates the long-term safety and ultrasound Doppler twinkling detectability of a PMMA breast biopsy marker following local perturbations and different dwell times in a 6-mo animal experiment. METHODS: This study, which was approved by our Institutional Animal Care and Use Committee, involved three pigs and utilized various markers, including PMMA (Zimmer Biomet), 3D-printed, and Tumark Q markers. Markers were implanted at different times for each pig. Mesh material or ethanol was used to induce a local inflammatory reaction near certain markers. A semiquantitative twinkling score assessed twinkling for actionable localization during monthly ultrasounds. At the primary endpoint, ultrasound-guided localization of lymph nodes with detectable markers was performed. Following surgical resection of the localized nodes, histomorphometric analysis was conducted to evaluate for tissue ingrowth and the formation of a tissue rind around the markers. RESULTS: No adverse events occurred. Twinkling scores of all markers for all three pigs decreased gradually over time. The Q marker exhibited the highest mean twinkling score followed by the PMMA marker, PMMA with mesh, and Q with ethanol. The 3D-printed marker with mesh and PMMA with ethanol had the lowest scores. All wire-localized lymph nodes were successfully resected. Despite varying percentages of tissue rind around the markers and a significant reduction in overall twinkling (p < 0.001) over time, mean PMMA twinkling scores remained clinically actionable at 6 and 5 mo using a General Electric C1-6 probe and 9L-probe, respectively. CONCLUSIONS: In this porcine model, the PMMA marker demonstrates an acceptable safety profile. Clinically actionable twinkling aids PMMA marker detection even after 6 mo of dwell time in porcine lymph nodes. The Q marker maintained the greatest twinkling over time compared to all the other markers studied.


Assuntos
Polimetil Metacrilato , Animais , Suínos , Feminino , Mama/diagnóstico por imagem , Ultrassonografia Mamária/métodos , Modelos Animais , Biópsia/métodos
5.
Eur J Radiol ; 168: 111118, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37804652

RESUMO

PURPOSE: Literature on how to perform intralesional steroid injections, a valuable therapy for idiopathic granulomatous mastitis (IGM), is limited. This technical note offers a detailed technical guide on intralesional steroid injections for IGM and provides a framework for long-term follow-up. METHODS: Ultrasound characterization of IGM severity considering breadth, depth, and ancillary findings was used to guide steroid dosing and injection frequency. Clinical and sonographic breast diagrams were designed for accurate longitudinal tracking of IGM. A step-by-step guide for ultrasound-guided IGM aspirations and intralesional steroid injections was developed. RESULTS: A detailed approach for ultrasound-guided IGM interventions with clinical and sonographic breast diagrams for longitudinal follow-up is now in practice. CONCLUSIONS: The treatment approach described provides a framework for multidisciplinary treatment of IGM and offers insights that may contribute to the ongoing development and improvement of management strategies for this challenging disease.


Assuntos
Mastite Granulomatosa , Feminino , Humanos , Mastite Granulomatosa/diagnóstico por imagem , Mastite Granulomatosa/tratamento farmacológico , Esteroides/uso terapêutico , Injeções , Imunoglobulina M/uso terapêutico
6.
Plast Reconstr Surg Glob Open ; 11(10): e5328, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37842077

RESUMO

Lymphaticovenous anastomosis (LVA) surgery is an effective surgery for the treatment of lymphedema in the extremities. Indocyanine green lymphography is the reference standard for visualizing lymphatics for LVA surgery, but it has several limitations; most notably, superficial dermal congestion can mask deeper lymphatic vessels. To overcome the limitations, we add contrast-enhanced ultrasound (CEUS) lymphography. We have previously reported that CEUS lymphography can identify lymphatic vessels for LVA surgery that indocyanine green lymphography does not. Here, we describe how we perform CEUS lymphography, including workflow, technique, and documentation. Before informed consent, the patient must be screened for possible adverse reactions to microbubbles. The procedure involves multiple intradermal injections of the microbubble agent at various sites along the extremity. After each injection, imaging for microbubble uptake by lymphatic vessels is performed using an ultrasound scanner with contrast-specific software. We use sulfur hexafluoride lipid-type A microspheres (Lumason/SonoVue; Bracco Suisse SA), but we are investigating the performance of other Food & Drug Administration-approved microbubble agents for CEUS lymphography. Having a systematic approach to marking the skin can mitigate the hindrance of marking over ultrasound coupling gel. Another benefit of CEUS lymphography is the rapid identification of neighboring veins compatible in size and location for anastomosis. We hold regular scheduled multidisciplinary meetings for coordination of care, discussion of outcomes, quality assurance, and ongoing innovation.

7.
Eur Radiol ; 33(11): 7360-7370, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37553488

RESUMO

OBJECTIVE: To identify variables predictive of durable clinical success after MRI-guided focused ultrasound (MRgFUS) treatment of uterine fibroids. MATERIALS AND METHODS: In this prospective, multicenter trial, 99 women with symptomatic uterine fibroids were treated using MRgFUS. Pelvic MRI was obtained at baseline and treatment day. The Uterine Fibroid Symptom-Quality of Life questionnaire was used to calculate a symptom severity score (SSS) at baseline and 6, 12, 24, and 36 months following treatment. Clinical, imaging, and treatment variables were correlated with symptom reduction sustained through the 12- and 24-month time points using univariable and multivariable logistic regression analyses. A novel parameter, the ratio of non-perfused volume to total fibroid load (NPV/TFL), was developed to determine association with durable outcomes. RESULTS: Post-treatment, mean symptom severity decreased at the 6-, 12-, 24-, and 36-month follow-ups (p < 0.001, all time points). In univariable analysis, three variables predicted treatment success (defined by ≥ 30-point improvement in SSS) sustained at both the 12-month and 24-month time points: increasing ratio of NPV/TFL (p = 0.002), decreasing total fibroid load (p = 0.04), and the absence of T2-weighted Funaki type 2 fibroids (p = 0.02). In multivariable analysis, the NPV/TFL was the sole predictor of durable clinical success (p = 0.01). Patients with ratios below 30% had less improvement in SSS and lacked durable clinical response compared with those between 30-79 (p = 0.03) and ≥ 80% (p = 0.01). CONCLUSION: Increased non-perfused volume relative to total fibroid volume was significantly associated with durable reduction of symptoms of abnormal uterine bleeding and bulk bother. CLINICAL RELEVANCE STATEMENT: Patient selection for sustained clinical benefit should emphasize those with likelihood of achieving high ablation ratios, as determined by imaging (e.g., device access, Funaki type) and by considering the total fibroid load, not just the primary symptomatic fibroid. TRIAL REGISTRATION: Clinical trial ID: NCT01285960. KEY POINTS: • Patient selection/treatment approach associated with durable symptom relief in MRI-guided focused ultrasound ablation of uterine fibroids remains unclear. • The ablation ratio, non-perfused volume/total fibroid volume, was positively associated with sustained symptom relief in both bleeding and bulk bother at 1- and 2-year follow-ups. • Selecting patients with imaging features that favor a high ratio of ablation to total fibroid load (including non-targeted fibroids) is the main factor in predicting durability of symptom relief after uterine fibroid treatment.


Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade , Leiomioma , Neoplasias Uterinas , Feminino , Humanos , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Leiomioma/diagnóstico por imagem , Leiomioma/terapia , Imageamento por Ressonância Magnética , Estudos Prospectivos , Qualidade de Vida , Resultado do Tratamento , Neoplasias Uterinas/diagnóstico por imagem , Neoplasias Uterinas/terapia
8.
Pain Med ; 24(11): 1219-1223, 2023 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-37478345

RESUMO

OBJECTIVE: To evaluate the safety and tolerability of MRI-guided focused ultrasound (MRgFUS) for the treatment of facet joint-mediated pain in human subjects for whom conventional treatment had failed. Secondarily, to evaluate effectiveness of the procedure. METHODS: Consecutive patients who underwent MRgFUS at our institution were retrospectively identified. Chart review was performed to obtain relevant clinical and technical data. All patients had chronic low back pain and positive comparative medial branch blocks. RESULTS: Twenty-six MRgFUS treatments in 20 patients were included. Mean sonication energy was 1436.6 Joules. The procedure was technically successful in all patients. Of the treated patients, 29.6% experienced short-term worsening of low back pain immediately after the procedure, all by 1-4 points on a 0-10 scale. One patient (3.8%) reported temporary worsening of preexisting radicular symptoms after the procedure. Of 21 treatments with clinical follow-up of at least 3 months available, 12 (57.1%) had >3 months' pain relief, 2 (10%) had <3 months' benefit, 6 (30%) reported no benefit, and 1 (5%) patient was lost to follow-up. In patients who reported at least some benefit with prior conventional radiofrequency ablation, 8/10 (80%) benefited from the MRgFUS procedure. CONCLUSION: The present study demonstrates that MRgFUS ablation of the lumbar facet joints is a safe and tolerable procedure in human subjects and could provide another option for patients for whom radiofrequency ablation had failed. More than half of all patients received significant durable pain relief, which jumped to 80% for patients who had experienced at least some benefit from prior radiofrequency ablations.


Assuntos
Dor Lombar , Bloqueio Nervoso , Articulação Zigapofisária , Humanos , Dor Lombar/terapia , Bloqueio Nervoso/métodos , Estudos Retrospectivos , Imageamento por Ressonância Magnética , Resultado do Tratamento
9.
J Vasc Surg ; 78(5): 1162-1169.e2, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37453587

RESUMO

OBJECTIVE: Stenting of renal and mesenteric vessels may result in changes in velocity measurements due to arterial compliance, potentially giving rise to confusion about the presence of stenosis during follow-up. The aim of our study was to compare preoperative and postoperative changes in peak systolic velocity (PSV, cm/s) after placement of the celiac axis (CA), superior mesenteric artery (SMA) and renal artery (RAs) bridging stent grafts during fenestrated-branched endovascular aortic repair (FB-EVAR) for treatment of complex abdominal aortic aneurysms (AAA) and thoracoabdominal aortic aneurysms. METHODS: Patients were enrolled in a prospective, nonrandomized single-center study to evaluate FB-EVAR for treatment of complex AAA and thoracoabdominal aortic aneurysms between 2013 and 2020. Duplex ultrasound examination of renal-mesenteric vessels were obtained prospectively preoperatively and at 6 to 8 weeks after the procedure. Duplex ultrasound examination was performed by a single vascular laboratory team using a predefined protocol including PSV measurements obtained with <60° angles. All renal-mesenteric vessels incorporated by bridging stent grafts using fenestrations or directional branches were analyzed. Target vessels with significant stenosis in the preoperative exam were excluded from the analysis. The end point was variations in PSV poststent placement at the origin, proximal, and mid segments of the target vessels for fenestrations and branches. RESULTS: There were 419 patients (292 male; mean age, 74 ± 8 years) treated by FB-EVAR with 1411 renal-mesenteric targeted vessels, including 260 CAs, 409 SMAs, and 742 RAs. No significant variances in the mean PSVs of all segments of the CA, SMA, and RAs at 6 to 8 weeks after surgery were found as compared with the preoperative values (CA, 135 cm/s vs 141 cm/s [P = .06]; SMA, 128 cm/s vs 125 cm/s [P = .62]; RAs, 90 cm/s vs 83 cm/s [P = .65]). Compared with baseline preoperative values, the PSV of the targeted vessels showed no significant differences in the origin and proximal segment of all vessels. However, the PSV increased significantly in the mid segment of all target vessels after stent placement. CONCLUSIONS: Stent placement in nonstenotic renal and mesenteric vessels during FB-EVAR is not associated with a significant increase in PSVs at the origin and proximal segments of the target vessels. Although there is a modest but significant increase in velocity measurements in the mid segment of the stented vessel, this difference is not clinically significant. Furthermore, PSVs in stented renal and mesenteric arteries were well below the threshold for significant stenosis in native vessels. These values provide a baseline or benchmark for expected PSVs after renal-mesenteric stenting during FB-EVAR.

10.
Radiol Imaging Cancer ; 5(4): e220168, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37326508

RESUMO

Breast biopsy markers play an essential role in the surgical management of patients with clinically node-positive breast cancer. Marking a pathology-proven lymph node ensures accurate imaging assessment of response to neoadjuvant systemic therapy and decreased false-negative rates in sentinel lymph node biopsy. There is a clinically unmet need to make breast biopsy markers, particularly in the axilla, more sonographically visible or identifiable for preoperative localization purposes. Previously described color Doppler US twinkling artifact of some breast biopsy markers in in vitro gel phantoms and in ex vivo cadaveric breasts suggests that twinkling of such markers can be leveraged for improved in vivo detection. In this retrospective case series of eight female patients (mean age, 58.6 years ± 12.3 [SD]), conventional B-mode US imaging failed to identify the biopsy marker associated with a surgical target in the breast or in an axillary lymph node. However, in each patient, the marker was successfully identified with the help of color Doppler US twinkling. Keywords: Breast, Ultrasound, Color Doppler US, Lymphatic, Artifacts, Biopsy Marker Published under a CC BY 4.0 license.


Assuntos
Artefatos , Neoplasias da Mama , Humanos , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Biópsia de Linfonodo Sentinela/métodos , Neoplasias da Mama/diagnóstico por imagem , Linfonodos/diagnóstico por imagem
11.
AJR Am J Roentgenol ; 220(3): 358-370, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36043610

RESUMO

BACKGROUND. Targeted axillary lymph node dissection after neoadjuvant systemic therapy (NST) for breast cancer depends on identifying marked metastatic lymph nodes. However, ultrasound visualization of biopsy markers is challenging. OBJECTIVE. The purpose of our study was to identify biopsy markers that show actionable twinkling in cadaveric breast and to assess the association of actionable twinkling with markers' surface roughness. METHODS. Commercial breast biopsy markers were evaluated for twinkling artifact in various experimental conditions relating to scanning medium (solid gel phantom, ultrasound coupling gel, cadaveric breast), transducer (ML6-15, 9L, C1-6), and embedding material (present vs absent). Markers were assigned twinkling scores from 0 (confident in no twinkling) to 4 (confident in exuberant twinkling); a score of 3 or greater represented actionable twinkling (sufficient confidence to rely solely on twinkling for target localization). Markers were hierarchically advanced to evaluation with increasingly complex media if showing at least minimal twinkling for a given medium. A 3D coherence optical profiler measured marker surface roughness. Mixed-effects proportional odds regression models assessed associations between twinkling scores and transducer and embedding material; Wilcoxon rank sum test evaluated associations between actionable twinkling and surface roughness. RESULTS. Thirty-five markers (21 with embedding material) were evaluated. Ten markers without embedding material advanced to evaluation in cadaveric breast. Higher twinkling scores were associated with presence of embedding material (odds ratio [OR] = 5.05 in solid gel phantom, 9.84 in coupling gel) and transducer (using the C1-6 transducer as reference; 9L transducer: OR = 0.36, 0.83, and 0.04 in solid gel phantom, ultrasound coupling gel, and cadaveric breast; ML6-15 transducer: OR = 0.07, 0.18, and 0.00 respectively; post hoc p between 9L and ML6-15: p < .001, p = .02, and p = .04). In cadaveric breast, three markers (Cork, Professional Q, MRI [Flex]) exhibited actionable twinkling for two or more transducers; surface roughness was significantly higher for markers with than without actionable twinkling for C1-6 (median values: 0.97 vs 0.35, p = .02) and 9L (1.75 vs 0.36; p = .002) transducers. CONCLUSION. Certain breast biopsy markers exhibited actionable twinkling in cadaveric breast. Twinkling was observed with greater confidence for the C1-6 and 9L transducers than the ML6-15 transducer. Actionable twinkling was associated with higher marker surface roughness. CLINICAL IMPACT. Use of twinkling for marker detection could impact preoperative or intraoperative localization after NST.


Assuntos
Neoplasias da Mama , Ultrassonografia Doppler em Cores , Humanos , Feminino , Ultrassonografia Doppler em Cores/métodos , Ultrassonografia , Imagens de Fantasmas , Artefatos , Cadáver , Biópsia
12.
Radiol Imaging Cancer ; 4(6): e220053, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36367449

RESUMO

Purpose To evaluate the short-term safety of a nonmetallic twinkle marker and compare its conspicuity at color Doppler US with that of standard breast biopsy clips and radioactive seeds by using B-mode US in axillary lymph nodes. Materials and Methods This prospective study (November 2020-July 2021) of participants with node-positive breast cancer who completed chemotherapy involved placing a twinkle marker at the time of preoperative radioactive seed localization. A five-point scoring system (1 = easiest, 5 = most difficult) was used to rate the ease of identifying the clip, seed, and twinkle marker on postlocalization sonograms, mammograms, specimen radiographs, and gross pathologic specimens. Descriptive statistics were used. Results Eight women (mean age, 57 years ± 16 [SD]) were enrolled. The median scores for US conspicuity of each device were 3.9 (range, 3.7-5.0) for the radioactive seed, 2.4 (range, 1.0-5.0) for the clip, and 2.0 (range, 1.0-4.3) for the twinkle marker. In six of eight participants, the twinkle marker was the most identifiable at US. The seeds, clips, and twinkle markers were scored "very easy" to identify on seven of eight postlocalization mammograms. The surgeon retrieved all eight twinkle markers 1-3 days after localization. In all 16 interpretations, the seeds, clips, and twinkle markers were rated as very easy to identify on specimen radiographs. The clip was the most difficult device to identify at pathologic examination in all participants, and the twinkle marker was the easiest to identify in seven of eight participants. Conclusion This pilot study demonstrates that the safety and ease of US detection of a twinkling tissue marker may be comparable to a biopsy clip. Keywords: Ultrasonography, US-Doppler, Breast, Localization, Surgery Clinical trial registration no. NCT04674852 © RSNA, 2022.


Assuntos
Neoplasias da Mama , Feminino , Humanos , Pessoa de Meia-Idade , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/cirurgia , Neoplasias da Mama/tratamento farmacológico , Projetos Piloto , Terapia Neoadjuvante , Estudos Prospectivos , Axila/patologia
13.
J Thromb Thrombolysis ; 54(3): 492-499, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35932383

RESUMO

BACKGROUND: Popliteal cysts (PC) result from distension of the gastrocnemio-semimembranosous bursa. Published reports indicate coincident PC and deep vein thrombosis (DVT). Whether the presence of PC increase the risk of deep vein thrombosis (DVT) remains unclear. METHODS: Lower extremity venous Duplex ultrasound (DUS) reports were evaluated across the Mayo Clinic Enterprise (Rochester, Minnesota, Jacksonville, Florida, Scottsdale, Arizona, and the Mayo Clinic Health System) in patients ≥ 18 years of age. Natural language processing (NLP) algorithms were created and validated to identify acute lower extremity DVT and PC from these reports. To determine whether there is a link between PC and lower extremity DVT, the frequency of PC among cases (ultrasounds with acute DVT) were compared to controls (ultrasounds without acute DVT). RESULTS: A total of 357,703 lower extremities venous DUS were performed in 237,052 patients (mean age 63.3 ± 16.6, 54.4% were female) between 1992 and 2021. Acute DVT was identified in 32,572 (9.1%) DUS, and PC in 32,448 (9.1%). PC were seen in a lower frequency (8.0%) of ultrasounds with acute DVT than those without (9.2%) acute DVT (OR: 0.85, 95% CI: 0.82 to 0.89, p < 0.001). In a multivariate logistic regression model after adjusting for age, sex, and race, PCs were not positively associated with acute DVT (adjusted OR: 0.84, 95% CI: 0.81 to 0.88). CONCLUSIONS: PC are an incidental finding or an alternative diagnosis on lower extremity venous DUS, a finding that increases significantly with age. PC were not a risk factor in the development of lower extremity DVT.


Assuntos
Cisto Popliteal , Trombose Venosa , Doença Aguda , Feminino , Humanos , Extremidade Inferior/irrigação sanguínea , Masculino , Cisto Popliteal/complicações , Cisto Popliteal/diagnóstico por imagem , Veia Poplítea/diagnóstico por imagem , Estudos Retrospectivos , Fatores de Risco , Ultrassonografia Doppler Dupla , Trombose Venosa/complicações , Trombose Venosa/diagnóstico por imagem , Trombose Venosa/epidemiologia
14.
Australas J Ultrasound Med ; 25(2): 54-65, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35722051

RESUMO

There are very few true breast emergencies. While infrequent, women do present to emergency departments or urgent care centres with breast-related concerns. In this case-based review, both common and uncommon urgent and emergent breast lesions are presented, emphasising ultrasound characteristics and imaging optimisation to improve accurate diagnosis and appropriate recommendations.

15.
Eur Radiol Exp ; 6(1): 26, 2022 06 17.
Artigo em Inglês | MEDLINE | ID: mdl-35711010

RESUMO

Since its first description 25 years ago, color Doppler twinkling has been a compelling ultrasound feature in diagnosing urinary stones. While the fundamental cause of twinkling remains elusive, the distinctive twinkling signature is diagnostically valuable in clinical practice. It can be inferred that if an entity twinkles, it empirically has certain physical features. This work investigates a manipulable polymeric material, polymethyl methacrylate (PMMA), which twinkles and has measurable surface roughness and porosity that likely contribute to twinkling. Comparative investigation of these structural properties and of the twinkling signatures of breast biopsy markers made from PMMA and selected commercially available markers showed how twinkling can improve ultrasound detection of devices intentionally designed to twinkle. While this specific application of detecting breast biopsy markers by twinkling may provide a way to approach an unmet need in the care of patients with breast cancer, this work ultimately provides a platform from which the keys to unlocking the fundamental physics of twinkling can be rigorously explored.


Assuntos
Artefatos , Cálculos Renais , Biópsia , Humanos , Cálculos Renais/patologia , Polimetil Metacrilato , Ultrassonografia Doppler em Cores
16.
Radiology ; 304(1): 218-224, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35380494

RESUMO

Background Lymphaticovenous anastomosis (LVA) surgery is an effective surgical treatment of secondary lymphedema in the extremities, but indocyanine green (ICG) fluorescent lymphography, the reference standard for imaging target lymphatic vessels, has several limitations. More effective methods are needed for preoperative planning. Purpose To evaluate whether contrast-enhanced US (CEUS) can be used to identify target lymphatic vessels for LVA surgery in patients with secondary upper extremity lymphedema and compare the results with those from ICG fluorescent lymphography. Materials and Methods In this single-center retrospective review, CEUS with intradermal injection of microbubbles was performed in patients before LVA surgery in the upper extremities between October 2019 and September 2021. All patients had secondary upper extremity lymphedema from breast cancer treatment. Technical success rate was defined as lymphatic vessels identified with use of CEUS that led to successful LVAs. Descriptive statistics were used. Results All 11 patients were women (mean age, 56 years ± 8 [SD]). The median number of microbubble injection sites was 11 (range, 8-14). CEUS helped identify lymphatic vessels in all 11 women, including in six women in whom ICG fluorescent lymphography could not be performed or failed to help identify any targets. Thirty-five explorations (median, three per patient; range, two to four) were performed, and 24 LVAs (median, three per patient; range, zero to four) were created. Of the anastomoses, 33% (eight of 24) were mapped with use of both CEUS and ICG fluorescent lymphography, 58% (14 of 24) with CEUS only, and 8% (two of 24) with ICG fluorescent lymphography only. Among the 33 explorations on targets mapped with CEUS, an anastomosis could be made at 22 sites, for a technical success rate of 67%. Seven women had at least one additional LVA created from the use of CEUS. Conclusion Contrast-enhanced US is a promising tool for identifying lymphatic vessels in the upper extremities, especially when indocyanine green fluorescent lymphography fails to depict targets or cannot be used. Published under a CC BY 4.0 license.


Assuntos
Vasos Linfáticos , Linfedema , Anastomose Cirúrgica/métodos , Corantes , Feminino , Humanos , Verde de Indocianina , Vasos Linfáticos/diagnóstico por imagem , Vasos Linfáticos/cirurgia , Linfedema/diagnóstico por imagem , Linfedema/cirurgia , Linfografia/métodos , Masculino , Microbolhas , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X
17.
J Womens Health (Larchmt) ; 31(4): 546-554, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34242085

RESUMO

Background: Women with uterine fibroids often seek uterine-preserving treatments, rather than hysterectomy. Imaging-defined endpoints following nonsurgical treatments for fibroids are limited. Materials and Methods: Fibroid Interventions: Reducing Symptoms Today and Tomorrow (FIRSTT), a randomized controlled trial of uterine artery embolization (UAE) versus magnetic resonance imaging-guided focused ultrasound surgery (MRgFUS), enrolled premenopausal women with symptomatic uterine fibroids. In this subanalysis, we report imaging results up to 36 months after UAE or MRgFUS. Magnetic resonance imaging (MRI) was performed at baseline for all women and during the 36 months after treatment if they did not meet other study endpoints. The main outcome of this subanalysis was fibroid volume reduction (defined both in terms of total fibroid load and volume of the largest fibroid), uterine volume reduction, and nonperfused volume. Results: During 2010-2014, 25 of the 37 women who were randomized and treated at Mayo Clinic had a 24-month follow-up MRI (11 UAE; 14 MRgFUS); among these women, 15 (7 UAE and 8 MRgFUS) had a 36-month follow-up MRI. Average age for the cohort was 44.1 (standard deviation, SD = 4.4) years. Nine patients had a second fibroid procedure by 36 months (seven in the MRgFUS arm and two in UAE arm). Median total fibroid load reduction was ∼50% in both treatment arms at both 24- and 36-month follow-up. Volume of the largest fibroid decreased more in the MRgFUS arm, whereas uterine volume decreased more in the UAE arm (neither reached statistical significance). At 24 months, median nonperfused volume was higher in the UAE arm (92%) than the MRgFUS arm (10%). Conclusions: Similar fibroid volume reduction was seen for the MRgFUS and UAE treatments in this comparative effectiveness study. Nonperfused volume 24 months after the procedure was higher in the UAE arm than in the MRgFUS arm. Clinical Trial Registration Number: NCT00995878, clinicaltrials.gov.


Assuntos
Leiomioma , Embolização da Artéria Uterina , Neoplasias Uterinas , Adulto , Feminino , Humanos , Histerectomia , Leiomioma/diagnóstico por imagem , Leiomioma/patologia , Leiomioma/terapia , Masculino , Resultado do Tratamento , Embolização da Artéria Uterina/métodos , Neoplasias Uterinas/diagnóstico por imagem , Neoplasias Uterinas/patologia , Neoplasias Uterinas/terapia
18.
Ultrasound Med Biol ; 47(11): 3122-3134, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34412903

RESUMO

In breast radiology, ultrasound detection of biopsy markers or clips for localization purposes is often challenging, especially in the axilla. The purpose of this research was to test the hypothesis that the surface roughness of biopsy clips would elicit a twinkling signature on color Doppler, making them more readily identifiable by ultrasound. Ultrasound color Doppler imaging of 12 biopsy markers was performed and consensus scoring of the degree of twinkling (0 [no twinkling] to 4 [exuberant twinkling]) was obtained for each of the markers. The surface roughness characteristics of the markers were measured using 3-D coherence scanning interferometry. The 3 markers scoring at least 3 for twinkling in vitro were cork, Q and Vision. Of these 3 markers, only the cork marker scored a 4 ex vivo and in cadaveric tissue. Surface roughness metrics demonstrated a positive estimated correlation with the twinkling scores (rho = 0.33, 95% CI = [-0.48 to 0.84]). Of the 12 markers tested, the markers that twinkled corresponded to surface roughness measured with non-contact 3-D optical imaging. Qualitatively, lower color scales and color frequencies optimized twinkling, but the most specific qualitative predictor of confidence in twinkling was insensitivity to changes in color scale and color frequency values.


Assuntos
Artefatos , Ultrassonografia Doppler em Cores , Axila , Biópsia , Humanos , Ultrassonografia
19.
Thromb Haemost ; 121(2): 216-223, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32828073

RESUMO

BACKGROUND: The objective of this study was to characterize clinical features and outcomes among patients with calf deep vein thrombosis (DVT) limited to the muscular veins compared with axial veins. METHODS: Consecutive patients with ultrasound confirmed acute DVT involving the calf veins (January 1, 2016-August 1, 2018) were identified from the Gonda Vascular Center ultrasound database. Patients were divided into axial or muscular groups based on thrombus location. Demographics, management, and outcomes were compared. RESULTS: Over the study period, there were 647 patients with calf DVT equally distributed between axial (n = 321) and muscular (n = 326) locations. Within these groups, peroneal and soleal veins were most commonly involved. Nearly all cases were provoked (97%). Synchronous pulmonary embolism (PE) were more common for axial (30.8%) compared to muscular groups (20.2%; p = 0.001); nearly one-third had no pulmonary symptoms. Anticoagulation for a median of 3 months was initiated for 85.5% of both groups. Venous thromboembolism (VTE) recurrence was more common in the axial group (15.9% vs. 7.1%, p = 0.0015) including more frequent DVT propagation (9.4% vs. 3.1%; p = 0.0017) and PE (3.4% vs. 0.6%; p = 0.0168). Major bleeding, clinically relevant nonmajor bleeding, and mortality rates did not differ between groups. Withholding anticoagulation led to more frequent thrombus propagation in the axial group (3.4% vs. 0.9%; p = 0.029). CONCLUSION: Several important features distinguish muscular from axial DVT. Axial DVT are more likely to have an associated PE and are more likely to experience recurrent VTE, particularly if anticoagulation is withheld.


Assuntos
Anticoagulantes/uso terapêutico , Veias/patologia , Trombose Venosa/tratamento farmacológico , Trombose Venosa/patologia , Idoso , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Músculos/irrigação sanguínea , Embolia Pulmonar/etiologia , Embolia Pulmonar/patologia , Resultado do Tratamento , Veias/efeitos dos fármacos , Trombose Venosa/complicações
20.
Acad Radiol ; 28(10): 1361-1367, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-32631759

RESUMO

OBJECTIVES: The aim of this study was to evaluate the impact of technology improvements on the outcomes of magnetic resonance-guided focused ultrasound (MRgFUS) treatments of symptomatic uterine leiomyomas (uterine fibroids). The study compared ablation volumes and incidence of adverse events in patient groups treated with two generations of MRgFUS systems from a single vendor. METHODS: The present study describes the results of a retrospective comparative study of two groups of women with symptomatic uterine leiomyomas who were clinically treated with MRgFUS at a single institution. Group 1 (n = 130) was treated using the first-generation system between March 2005 and December 2009. Group 2 (n = 71) was treated using the second-generation between December 2013 and September 2019. RESULTS: The second-generation MRgFUS system resulted in significantly improved nonperfused volume ratios in both dark and bright T2 fibroid categories compared with the first-generation system (dark - 80% versus46 %, p = 0.00002 and bright - 46% versus 32%, p = 0.001). There have been no recorded hospital admissions, no skins burns, and no reported major adverse events since the introduction of this second-generation ExAblate 2100 system with advanced safety and treatment planning features. CONCLUSION: This study has demonstrated that improvements to current MRgFUS technology resulted in significantly increased efficacy and patient safety of clinical treatments of patients with symptomatic uterine leiomyomas.


Assuntos
Leiomioma , Humanos , Leiomioma/diagnóstico por imagem , Leiomioma/terapia , Espectroscopia de Ressonância Magnética , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...