Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Toxicol Appl Pharmacol ; 276(1): 1-20, 2014 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-24382512

RESUMO

The applicability of rat precision-cut lung slices (PCLuS) in detecting nanomaterial (NM) toxicity to the respiratory tract was investigated evaluating sixteen OECD reference NMs (TiO2, ZnO, CeO2, SiO2, Ag, multi-walled carbon nanotubes (MWCNTs)). Upon 24-hour test substance exposure, the PCLuS system was able to detect early events of NM toxicity: total protein, reduction in mitochondrial activity, caspase-3/-7 activation, glutathione depletion/increase, cytokine induction, and histopathological evaluation. Ion shedding NMS (ZnO and Ag) induced severe tissue destruction detected by the loss of total protein. Two anatase TiO2 NMs, CeO2 NMs, and two MWCNT caused significant (determined by trend analysis) cytotoxicity in the WST-1 assay. At non-cytotoxic concentrations, different TiO2 NMs and one MWCNT increased GSH levels, presumably a defense response to reactive oxygen species, and these substances further induced a variety of cytokines. One of the SiO2 NMs increased caspase-3/-7 activities at non-cytotoxic levels, and one rutile TiO2 only induced cytokines. Investigating these effects is, however, not sufficient to predict apical effects found in vivo. Reproducibility of test substance measurements was not fully satisfactory, especially in the GSH and cytokine assays. Effects were frequently observed in negative controls pointing to tissue slice vulnerability even though prepared and handled with utmost care. Comparisons of the effects observed in the PCLuS to in vivo effects reveal some concordances for the metal oxide NMs, but less so for the MWCNT. The highest effective dosages, however, exceeded those reported for rat short-term inhalation studies. To become applicable for NM testing, the PCLuS system requires test protocol optimization.


Assuntos
Apoptose/efeitos dos fármacos , Pulmão/efeitos dos fármacos , Nanotubos/toxicidade , Estresse Oxidativo/efeitos dos fármacos , Alternativas ao Uso de Animais , Animais , Sobrevivência Celular , Fenômenos Químicos , Cruzamentos Genéticos , Citocinas/metabolismo , Emulsificantes/química , Feminino , Glutationa/agonistas , Glutationa/metabolismo , Técnicas In Vitro , Pulmão/citologia , Pulmão/imunologia , Pulmão/metabolismo , Teste de Materiais/métodos , Nanopartículas Metálicas/química , Nanopartículas Metálicas/toxicidade , Nanopartículas Metálicas/ultraestrutura , Nanotubos/química , Nanotubos/ultraestrutura , Nanotubos de Carbono/química , Nanotubos de Carbono/toxicidade , Nanotubos de Carbono/ultraestrutura , Ratos , Ratos Wistar , Reprodutibilidade dos Testes , Soroalbumina Bovina/química , Sonicação , Regulação para Cima/efeitos dos fármacos
2.
Toxicol In Vitro ; 27(1): 174-90, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23085368

RESUMO

The usefulness of in vitro systems to predict acute inhalation toxicity was investigated. Nineteen substances were tested in three-dimensional human airway epithelial models, EpiAirway™ and MucilAir™, and in A549 and 3T3 monolayer cell cultures. IC(50) values were compared to rat four-hour LC(50) values classified according to EPA and GHS hazard categories. Best results were achieved with a prediction model distinguishing toxic from non-toxic substances, with satisfactory specificities and sensitivities. Using a self-made four-level prediction model to classify substances into four in vitro hazard categories, in vivo-in vitro concordance was mediocre, but could be improved by excluding substances causing pulmonary edema and emphysema in vivo. None of the test systems was outstanding, and there was no evidence that tissue or monolayer systems using respiratory tract cells provide an added value. However, the test systems only reflected bronchiole epithelia and alveolar cells and investigated cytotoxicity. Effects occurring in other cells by other mechanisms could not be recognised. Further work should optimise test protocols and expand the set of substances tested to define applicability domains. In vivo respiratory toxicity data for in vitro comparisons should distinguish different modes of action, and their relevance for human health effects should be ensured.


Assuntos
Alternativas aos Testes com Animais/métodos , Técnicas de Cultura de Células/métodos , Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos , Pulmão/efeitos dos fármacos , Células 3T3 , Administração por Inalação , Animais , Linhagem Celular Tumoral , Humanos , Dose Letal Mediana , Camundongos , Modelos Biológicos , Ratos , Testes de Toxicidade Aguda
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...