1.
J Neuroimaging ; 32(2): 292-299, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34964194

RESUMO

BACKGROUND AND PURPOSE: MRI has a crucial role in presurgical evaluation of drug-resistant focal epilepsy patients. Whether and how much 7T MRI further improves presurgical diagnosis compared to standard of care 3T MRI remains to be established. We investigate the added value 7T MRI offers in surgical candidates with remaining clinical uncertainty after 3T MRI. METHODS: 7T brain MRI was obtained on sequential patients with drug-resistant focal epilepsy undergoing presurgical evaluation at a comprehensive epilepsy center, including patients with and without suspected lesions on standard 3T MRI. Clinical information and 3T images informed the interpretation of 7T images. Detection of a new lesion on 7T or better characterization of a suspected lesion was considered to add value to the presurgical workup. RESULTS: Interpretable 7T MRI was acquired in 19 patients. 7T MRI identified a lesion relevant to the seizures in three of eight patients (38%) without a lesion on 3T MRI; no lesion in 7/11 patients (64%) with at least one suspected lesion on 3T MRI, contributing to the final classification of all seven as nonlesional; and confirmed and better characterized the lesion suspected at 3T MR in the remaining 4/11 patients. CONCLUSIONS: 7T MRI detected new lesions in over a third of 3T MRI nonlesional patients, confirmed and better characterized a 3T suspected lesion in one third of patients, and helped exclude a 3T suspected lesion in the remainder. Our initial experience suggests that 7T MRI adds value to surgical planning by improving detection and characterization of suspected brain lesions in drug-resistant focal epilepsy patients.


Assuntos
Epilepsia Resistente a Medicamentos , Epilepsia , Tomada de Decisão Clínica , Epilepsia Resistente a Medicamentos/diagnóstico por imagem , Epilepsia Resistente a Medicamentos/cirurgia , Humanos , Imageamento por Ressonância Magnética/métodos , Incerteza
2.
Nat Commun ; 10(1): 2945, 2019 07 03.
Artigo em Inglês | MEDLINE | ID: mdl-31270332

RESUMO

Age- and sex-related alterations in gene transcription have been demonstrated, however the underlying mechanisms are unresolved. Neuroepigenetic pathways regulate gene transcription in the brain. Here, we measure in vivo expression of the epigenetic enzymes, histone deacetylases (HDACs), across healthy human aging and between sexes using [11C]Martinostat positron emission tomography (PET) neuroimaging (n = 41). Relative HDAC expression increases with age in cerebral white matter, and correlates with age-associated disruptions in white matter microstructure. A post mortem study confirmed that HDAC1 and HDAC2 paralogs are elevated in white matter tissue from elderly donors. There are also sex-specific in vivo HDAC expression differences in brain regions associated with emotion and memory, including the amygdala and hippocampus. Hippocampus and white matter HDAC expression negatively correlates with emotion regulation skills (n = 23). Age and sex are associated with HDAC expression in vivo, which could drive age- and sex-related transcriptional changes and impact human behavior.


Assuntos
Encéfalo/fisiologia , Epigênese Genética , Caracteres Sexuais , Adamantano/análogos & derivados , Adamantano/farmacocinética , Adolescente , Adulto , Fatores Etários , Idoso , Encéfalo/diagnóstico por imagem , Radioisótopos de Carbono/farmacocinética , Emoções , Feminino , Histona Desacetilase 1/metabolismo , Histona Desacetilase 2/metabolismo , Humanos , Ácidos Hidroxâmicos/farmacocinética , Masculino , Pessoa de Meia-Idade , Doadores de Tecidos , Substância Branca/anatomia & histologia , Substância Branca/diagnóstico por imagem , Adulto Jovem
3.
Eur J Nucl Med Mol Imaging ; 45(12): 2147-2154, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-29998420

RESUMO

PURPOSE: To compare the clinical performance of upper abdominal PET/DCE-MRI with and without concurrent respiratory motion correction (MoCo). METHODS: MoCo PET/DCE-MRI of the upper abdomen was acquired in 44 consecutive oncologic patients and compared with non-MoCo PET/MRI. SUVmax and MTV of FDG-avid upper abdominal malignant lesions were assessed on MoCo and non-MoCo PET images. Image quality was compared between MoCo DCE-MRI and non-MoCo CE-MRI, and between fused MoCo PET/MRI and fused non-MoCo PET/MRI images. RESULTS: MoCo PET resulted in higher SUVmax (10.8 ± 5.45) than non-MoCo PET (9.62 ± 5.42) and lower MTV (35.55 ± 141.95 cm3) than non-MoCo PET (38.11 ± 198.14 cm3; p < 0.005 for both). The quality of MoCo DCE-MRI images (4.73 ± 0.5) was higher than that of non-MoCo CE-MRI images (4.53±0.71; p = 0.037). The quality of fused MoCo-PET/MRI images (4.96 ± 0.16) was higher than that of fused non-MoCo PET/MRI images (4.39 ± 0.66; p < 0.005). CONCLUSION: MoCo PET/MRI provided qualitatively better images than non-MoCo PET/MRI, and upper abdominal malignant lesions demonstrated higher SUVmax and lower MTV on MoCo PET/MRI.


Assuntos
Neoplasias Abdominais/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Imagem Multimodal/métodos , Tomografia por Emissão de Pósitrons/métodos , Técnicas de Imagem de Sincronização Respiratória/métodos , Abdome/diagnóstico por imagem , Adulto , Feminino , Humanos , Masculino , Movimento (Física)
4.
Lasers Surg Med ; 48(5): 555-61, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-26842919

RESUMO

BACKGROUND AND OBJECTIVE: Fractional Photothermolysis (FP) is a method of skin treatment that generates a thermal damage pattern consisting of multiple columns of thermal damage, also known as microscopic treatment zones (MTZs). They are very small in diameter and are generated by application of highly focused laser beams. In order to obtain the smallest spot size, the treatment should be performed in the focal plane. Any deviation from the focal plane (DFP) results in an increase of spot size. FP devices typically utilize distance holders in order to facilitate exposures at this specific location. In spite of the use of distance holders, DFP can occur. In particular, variations of contact pressure to the skin surface and anatomical treatment areas of high surface curvature may be prone to DFP during FP treatments. The impact of such distance variation on lesion geometry, such as depth and diameter of the thermal injury, has not previously been evaluated. The objective of this study was to investigate the relation between DFP and the resulting lesion geometry for a selected ablative fractional device. MATERIAL AND METHODS: A handpiece of an ablative fractional laser (DeepFX, UltraPulse Encore, Lumenis, Yokneam, Israel) was mounted to a rigid stand. Full thickness human skin obtained from abdominoplasty was mounted to a separate stand perpendicular to the handpiece. The tissue stand allowed the distance between the handpiece and the tissue to be adjusted to produce a variation up to ±3 mm from the focal plane. A 1 × 1 cm(2) scanning area of 169 MTZs, 50 mJ energy per MTZ, 120 µm nominal spot size, was applied at -3, -2, -1, 0, +1, +2, and +3 mm deviated from the focal plane. Minus (-) and plus (+) signs indicate decreasing and increasing distance between the handpiece and the tissue, respectively. Depth and diameter of the laser induced tissue lesions were assessed and quantified. RESULTS: DFPs produced a significant alteration of the lesion geometry. DFPs of -3, -2, -1, 0, +1, +2, +3 mm resulted in average lesion depths of 1,020 (-40%), 1,180 (-31%), 1,400 (-18%), 1,700 (0%), 1,620 (-5%), 780 (-55%), 680 (-60%) µm, and average lesion diameters of 314 (+26%), 311 (+25%), 273 (+10%), 248 (0%), 256 (+3%), 316 (+27%), 359 (+44%) µm, respectively. The underlined values represent the focal plane. The percentage changes relative to values at focal plane are in parentheses. CONCLUSIONS: A relatively minor DFP has a marked impact on the thermal injury profile, including lesion depth and diameter, of the laser-exposed tissue. Such marked changes of the thermal injury profile might affect the wound healing, safety, and efficacy of ablative fractional resurfacing procedures. Clinicians should carefully maintain the focal plane during ablative fractional treatment for reproducible results. The presented data are device specific and the clinical impact of such alteration of thermal injury profile warrants further investigation. Lasers Surg. Med. 48:555-561, 2016. © 2016 Wiley Periodicals, Inc.


Assuntos
Queimaduras/etiologia , Terapia a Laser/efeitos adversos , Pele/lesões , Queimaduras/diagnóstico , Queimaduras/patologia , Humanos , Técnicas In Vitro , Terapia a Laser/instrumentação , Terapia a Laser/métodos , Pele/patologia