1.
Chemosphere ; 60(11): 1565-71, 2005 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16083762

RESUMO

Successful applications of different analytical procedures to determine quantitatively endosulfan and its metabolites in aqueous media can be found in recent literature. Fundamentally, they have made use of solid-phase extraction (SPE) and gas (GC) or liquid chromatography (LC), sometimes coupled to mass spectrometry (MS). In this paper, a new and alternative methodology to determine quantitatively endosulfan in aqueous media is reported. A C18-modified carbon-paste electrode has been used to determine voltammetrically endosulfan, despite its unfavourable electrochemical properties and behaviour. The methodology proposed is based on the decrease experienced by the peak intensity corresponding to voltammetric signals of Cu(II) when successive and constant additions of endosulfan are carried out. This decrease is directly proportional to the concentration of endosulfan what allows to perform an indirect quantification of the pesticide. The detection limit obtained is 40 ng l(-1), this value being under the limits specified by European norms and EPA reports.


Assuntos
Carbono , Eletrodos , Endossulfano/análise , Inseticidas/análise , Soluções/análise , Cobre/química , Eletroquímica , Concentração de Íons de Hidrogênio , Reprodutibilidade dos Testes , Água
2.
Anal Chem ; 74(10): 2423-7, 2002 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-12038770

RESUMO

In this work, a novel sol-gel-based procedure to obtain solid carbon composite electrodes is proposed. The procedure is based on the use of sonocatalysis to apply high-energy ultrasound directly to the precursors; this way, ultrasonic cavitation is achieved so that hydrolysis with acidic water is promoted in the absence of any additional solvent and the time needed to get a unique phase is reduced drastically. The mix of sonogel with spectroscopic grade graphite leads to a new type of sol-gel electrode: the Sonogel-Carbon electrode. The amount of water, necessary for hydrolysis to occur, has been studied, as well as the sol pH value and the electrochemical behavior of the Sonogel-Carbon electrode in Britton-Robinson buffer. Mechanical renewal of the electrodes surfaces and background signal stability for at least 42 days have been also tested. We have carried out some tests to check the ability of the synthesized material to give electrochemical response when redox species are present in the background electrolyte. Mechanical and electrochemical studies indicate that the Sonogel-Carbon electrode shows good properties for use as an electrochemical sensor.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...