Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Contraception ; 80(1): 84-9, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19501221

RESUMO

BACKGROUND: The levonorgestrel-releasing intrauterine system (LNG-IUS) is a contraceptive method approved for five years of use. However, there is some evidence that its life span may be longer. The aim of the study was to evaluate serum levonorgestrel (LNG) and estradiol (E(2)) levels and endometrial thickness every 6 months from 7 to 8 1/2 years after insertion. STUDY DESIGN: At the end of the approved 5-year life span, no replacement devices were available; therefore, 86 women were allowed to retain the same device for a further 2 years. At the 7-year follow-up visit, the women who consented were again allowed to retain the same device for a further 18 months and were followed-up at six-monthly intervals. At each visit, vaginal sonography was performed to measure endometrial thickness, and a blood sample was taken to measure LNG and E(2). RESULTS: Eighty-four months after insertion, 67 women aged 34.3+/-0.8 years (mean+/-SEM) (range, 25-49 years) returned for follow-up. Mean+/-SEM LNG levels decreased from an initial 253+/-27 pg/mL (range, 86-760) during the first 2 months following insertion to 137+/-12 (range, 23-393) at 84 months and 119+/-9 pg/mL (range, 110-129) at 102 months of use (+/-SEM). At 84 months of use, mean+/-SEM endometrial thickness was 2.8+/-0.1 mm, increasing to 3.8+/-0.5 mm at 102 months of use. The incidence of amenorrhea decreased from 41.8% at 84 months to 31.5% at 102 months of use. No correlation was found between LNG levels and bleeding patterns; however, a weak correlation was found between high body mass index (kg/m(2)), high weight, and low serum LNG levels. E(2) levels were similar to those of the follicular phase of the menstrual cycle of regularly menstruating women. CONCLUSIONS: During extended use of the LNG-IUS, serum LNG levels were nearly half those found in the first 2 months of use (Wilcoxon signed rank test); serum E(2) levels were normal. Despite the very thin endometrium, menstrual bleeding was reinstated in many cases. At the end of its 5-year life span, there is a window for changing the LNG-IUS, and physicians and users should not be concerned about delaying replacement of the device for a short time beyond the approved life span; however, maintaining the same device long after its approved life span cannot be recommended.


Assuntos
Anticoncepcionais Femininos/sangue , Endométrio/efeitos dos fármacos , Estradiol/sangue , Dispositivos Intrauterinos Medicados , Levanogestrel/sangue , Adulto , Anticoncepcionais Femininos/administração & dosagem , Estradiol/administração & dosagem , Feminino , Humanos , Levanogestrel/administração & dosagem , Pessoa de Meia-Idade , Fatores de Tempo
2.
Hum Reprod ; 21(5): 1316-9, 2006 May.
Artigo em Inglês | MEDLINE | ID: mdl-16373404

RESUMO

BACKGROUND: There are concerns about the effect of hormonal contraceptives on bone mineral density (BMD), but there is currently no information available on the effect of the levonorgestrel-releasing intrauterine system (LNG-IUS) on BMD. The objective of this study was to compare the BMD of LNG-IUS users with that of controls using the TCu380A intrauterine device (IUD). MATERIALS AND METHODS: A cross-sectional study paired 53 women, aged 25-51 years, who had been using the LNG-IUS for 7 years, with 53 IUD users, according to age (+/-1 year) and body mass index (BMI; kg/m2) (+/-1). BMD was evaluated at the midshaft of the ulna and the distal radius of the nondominant forearm using double X-ray absorptiometry. RESULTS: Mean age of women was 34 years. BMI was slightly over 25 in both groups. Estradiol was normal. Mean BMD was 0.469 +/- 0.008 and 0.467 +/- 0.009 and 0.409 +/- 0.009 and 0.411 +/- 0.009 at the midshaft of the ulna and distal radius in LNG-IUS and IUD users, respectively, without significant differences. CONCLUSIONS: Women aged 25-51 years, using the LNG-IUS for 7 years, had a mean BMD similar to that of the control group of TCu380A IUD users.


Assuntos
Densidade Óssea/efeitos dos fármacos , Anticoncepcionais Femininos/administração & dosagem , Dispositivos Intrauterinos Medicados , Levanogestrel/administração & dosagem , Rádio (Anatomia)/efeitos da radiação , Ulna/efeitos da radiação , Absorciometria de Fóton , Adulto , Estudos Transversais , Estradiol/sangue , Feminino , Antebraço/diagnóstico por imagem , Humanos , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...