Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
Int J Mol Sci ; 24(7)2023 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-37047137

RESUMO

Lens epithelium-derived growth factor splice variant of 75 kDa (LEDGF/p75) is an autoantigen over-expressed in solid tumors and acts as a stress-related transcriptional co-activator. Participation of autoimmune responses in the pathophysiology of benign prostatic hyperplasia (PBH) and a corresponding immunosuppressive therapy by TNFalpha antagonists has been recently suggested. Thus, autoAb testing could aid in the diagnosis of BPH patients profiting from such therapy. We generated CRISPR/Cas9 modified HEp-2 LEDGF knock-out (KO) and HEp-2 LEDGF/p75 over-expressing (OE) cells and examined IgG autoantibody reactivity to LEDGF/p75 in patients with prostate cancer (PCa, n = 89), bladder cancer (BCa, n = 116), benign prostatic hyperplasia (BPH, n = 103), and blood donors (BD, n = 60) by indirect immunofluorescence assay (IFA). Surprisingly, we could not detect elevated binding of autoAbs against LEDGF/p75 in cancer patients, but autoAb reactivity to LEDGF/p75 OE cells in about 50% of patients with BPH was unexpectedly significantly increased. Furthermore, a line immunoassay enabling the detection of 18 different autoAbs revealed a significantly increased occurrence of anti-dsDNA autoAbs in 34% of BPH patients in contrast to tumor patients and BD. This finding was confirmed by anti-mitochondrial (mDNA) autoAb detection with the Crithidia luciliae immunofluorescence test, which also showed a significantly higher prevalence (34%) of anti-mDNA autoAbs in BPH. In summary, our study provided further evidence for the occurrence of autoimmune responses in BPH. Furthermore, LEDGF/p75 over-expression renders HEp-2 cells more autoantigenic and an ideal target for autoAb analysis in BPH with a potential therapy consequence.


Assuntos
Hiperplasia Prostática , Masculino , Humanos , Hiperplasia Prostática/diagnóstico , Hiperplasia Prostática/genética , Linhagem Celular Tumoral , Peptídeos e Proteínas de Sinalização Intercelular/genética , Imunoglobulina G
2.
Clin Chem Lab Med ; 56(6): 919-926, 2018 05 24.
Artigo em Inglês | MEDLINE | ID: mdl-29329103

RESUMO

BACKGROUND: Unlike for acute immune-mediated neuropathies (IN), anti-ganglioside autoantibody (aGAAb) testing has been recommended for only a minority of chronic IN yet. Thus, we used a multiplex semi-quantitative line immunoassay (LIA) to search for aGAAb in chronic-inflammatory demyelinating polyneuropathy (CIDP) and its clinical variants. METHODS: Anti-GAAb to 11 gangliosides and sulfatide (SF) were investigated by LIA in 61 patients with IN (27 typical CIDP, 12 distal-acquired demyelinating polyneuropathy, 6 multifocal-acquired demyelinating sensory/motor polyneuropathy, 10 sensory CIDP, 1 focal CIDP and 5 multifocal-motoric neuropathy), 40 with other neuromuscular disorders (OND) (15 non-immune polyneuropathies, 25 myasthenia gravis), 29 with multiple sclerosis (MS) and 54 healthy controls (HC). RESULTS: In contrast to IgG, positive anti-GAAB IgM against at least one ganglioside/SF was found in 17/61 (27.9%) IN compared to 2/40 (5%) in OND, 2/29 MS (6.9%) and 4/54 (7.4%) in HC (p=0.001). There was a statistically higher prevalence of anti-sulfatide (aSF) IgM in IN compared to OND (p=0.008). Further, aGM1 IgM was more prevalent in IN compared to OND and HC (p=0.009) as well as GD1b in IN compared to HC (p<0.04). The prevalence of aGM1 IgM in CIDP was lower compared to in multifocal motor neuropathy (MMN) (12% vs. 60%, p=0.027). Patients showing aSF, aGM1 and aGM2 IgM were younger compared to aGAAb negatives (p<0.05). Patients with aSF IgM positivity presented more frequently typical CIDP and MMN phenotypes (p<0.05, respectively). CONCLUSIONS: The aGAAb LIA revealed an elevated frequency of at least one aGAAb IgM in CIDP/MMN patients. Anti-SF, aGM1 and aGM2 IgM were associated with younger age and anti-SF with IN phenotypes.


Assuntos
Autoanticorpos/sangue , Gangliosídeos/imunologia , Técnicas Imunoenzimáticas/métodos , Polirradiculoneuropatia Desmielinizante Inflamatória Crônica/diagnóstico , Polirradiculoneuropatia Desmielinizante Inflamatória Crônica/imunologia , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polirradiculoneuropatia Desmielinizante Inflamatória Crônica/sangue , Reprodutibilidade dos Testes
3.
Clin Rev Allergy Immunol ; 53(1): 87-104, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27368807

RESUMO

Occurrence of autoantibodies (autoAbs) is a hallmark of autoimmune diseases, and the analysis thereof is an essential part in the diagnosis of organ-specific autoimmune and systemic autoimmune rheumatic diseases (SARD), especially connective tissue diseases (CTDs). Due to the appearance of autoAb profiles in SARD patients and the complexity of the corresponding serological diagnosis, different diagnostic strategies have been suggested for appropriate autoAb testing. Thus, evolving assay techniques and the continuous discovery of novel autoantigens have greatly influenced the development of these strategies. Antinuclear antibody (ANA) analysis by indirect immunofluorescence (IIF) on tissue and later cellular substrates was one of the first tests introduced into clinical routine and is still an indispensable tool for CTD serology. Thus, screening for ANA by IIF is recommended to be followed by confirmatory testing of positive findings employing different assay techniques. Given the continuous growth in the demand for autoAb testing, IIF has been challenged as the standard method for ANA and other autoAb analyses due to lacking automation, standardization, modern data management, and human bias in IIF pattern interpretation. To address these limitations of autoAb testing, the CytoBead® technique has been introduced recently which enables automated interpretation of cell-based IIF and quantitative autoAb multiplexing by addressable microbead immunoassays in one reaction environment. Thus, autoAb screening and confirmatory testing can be combined for the first time. The present review discusses the history of autoAb assay techniques in this context and gives an overview and outlook of the recent progress in emerging technologies.


Assuntos
Autoanticorpos/imunologia , Técnica Indireta de Fluorescência para Anticorpo/métodos , Anticorpos Antinucleares/sangue , Anticorpos Antinucleares/imunologia , Autoanticorpos/sangue , Doenças Autoimunes/sangue , Doenças Autoimunes/diagnóstico , Doenças Autoimunes/imunologia , Autoimunidade , Biomarcadores , Humanos
4.
Medicine (Baltimore) ; 95(44): e5225, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27858870

RESUMO

Rapidly progressive glomerulonephritis (RPGN) is mainly caused by anti-glomerular basement membrane (GBM) antibody-mediated glomerulonephritis, immune-complex or anti-neutrophil cytoplasmic antibody (ANCA)-associated vasculitides and leads to rapid loss of renal function. Detection of ANCA and autoantibodies (autoAbs) to GBM and dsDNA enables early diagnosis and appropriate treatment of RPGN aiding in preventing end-stage renal disease.Determination of ANCA on neutrophils (ANCA) as well as autoAbs to myeloperoxidase (MPO-ANCA), proteinase 3 (PR3-ANCA), GBM, and dsDNA was performed by the novel multiplex CytoBead technology combining cell- and microbead-based autoAb analyses by automated indirect immunofluorescence (IIF). Forty patients with granulomatosis with polyangiitis (GPA), 48 with microscopic polyangiitis (MPA), 2 with eosinophilic GPA, 42 with systemic lupus erythematosus (SLE), 43 with Goodpasture syndrome (GPS), 57 with infectious diseases (INF), and 55 healthy subjects (HS) were analyzed and findings compared with classical single testing.The CytoBead assay revealed for GPA, MPA, GPS, and SLE the following diagnostic sensitivities and for HS and INF the corresponding specificities: PR3-ANCA, 85.0% and 100.0%; MPO-ANCA, 77.1% and 99.1%; anti-GBM autoAb, 88.4% and 96.4%; anti-dsDNA autoAb, 83.3% and 97.3%; ANCA, 91.1% and 99.1%, respectively. Agreement with classical enzyme-linked immunosorbent assay and IIF was very good for anti-GBM autoAb, MPO-ANCA, PR3-ANCA, and ANCA, respectively. Anti-dsDNA autoAb comparative analysis demonstrated fair agreement only and a significant difference (P = 0.0001).The CytoBead technology provides a unique multiplex reaction environment for simultaneous RPGN-specific autoAb testing. CytoBead RPGN assay is a promising alternative to time-consuming single parameter analysis and, thus, is well suited for emergency situations.


Assuntos
Anticorpos Anticitoplasma de Neutrófilos/análise , Glomerulonefrite/sangue , Glomerulonefrite/imunologia , Neutrófilos/química , Adulto , Idoso , Estudos de Casos e Controles , Pré-Escolar , Progressão da Doença , Feminino , Técnica Indireta de Fluorescência para Anticorpo , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo
5.
J Immunol Methods ; 433: 17-22, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-26921629

RESUMO

INTRODUCTION: NOVA View is a computer aided fluorescence microscope that is used for the automated reading and interpretation of indirect immunofluorescent tests in diagnostic immunology. The objective of the present study was to evaluate the performance of the NOVA View® system for the measurement of anti-dsDNA antibodies using the Crithidia luciliae indirect immunofluorescence test (CLIFT) technology. METHODS: Analytical performance of NOVA View CLIFT was assessed in repeatability (within run) and reproducibility (between runs and instruments) studies. Two hundred-fifty patient samples (N=200 consecutive samples and N=50 samples from systemic lupus erythematosus patients) were tested to evaluate the agreement between results generated with NOVA View CLIFT, and those obtained with manual microscopic reading of the same slides. Positivity rate in SLE was assessed on the 50 SLE samples. RESULTS: The NOVA View system showed high level of repeatability and reproducibility within runs, between runs, and between instruments. Agreement of NOVA View software interpretation and digital image reading results with manual microscopic reading results was 96.0%, and the same positivity rate was obtained on SLE samples by NOVA View digital image reading as that of manual microscopic reading (36.0% vs. 38.0%, respectively). CONCLUSION: Results generated by NOVA View CLIFT were equivalent to those obtained by manual microscopic reading on a large routine sample set. NOVA View demonstrated consistency within and between runs, and between instruments. Automation of CLIFT provides reliability and is a suitable alternative for routine clinical laboratories.


Assuntos
Anticorpos Antinucleares/análise , Técnica Indireta de Fluorescência para Anticorpo/métodos , Interpretação de Imagem Assistida por Computador , Microscopia de Fluorescência/métodos , Software , Ensaio de Imunoadsorção Enzimática , Humanos , Lúpus Eritematoso Sistêmico/diagnóstico , Kit de Reagentes para Diagnóstico , Reprodutibilidade dos Testes
6.
Auto Immun Highlights ; 7(1): 2, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26831868

RESUMO

PURPOSE: Celiac disease (CD) serology requires analysis of tissue transglutaminase type-2 (TG2autoAbs), deamidated gliadin (DGAbs), and as reference endomysial autoantibodies (EmA). Total IgA assessment helps to determine IgA-deficient CD patients. The novel multiplex indirect immunofluorescence (IIF) technique CytoBead was used to develop the first quantitative one-step serological CD assay comprising both simultaneous IgA autoAb and total IgA testing. METHODS: CytoBead CeliAK detecting TG2autoAb, DGAb, EmA, and simultaneously total IgA uses fluorescent microparticles for antigen and antibody immobilization along with monkey-esophagus tissue sections on glass slides. The assay was interpreted visually by classical fluorescent microscopy and digital IIF using AKLIDES(®). Overall, 380 samples (155 CD patients, 5 with IgA deficiency, 68 with cystic fibrosis, 59 with eye disease, 93 blood donors) were run for performance analysis. Data were compared with classical IgA autoAb analysis by ELISA and IIF. RESULTS: Comparing CD-specific IgA autoAb testing by CytoBead with classical IIF and ELISA, very good agreements for EmA, TG2autoAb, and DGAb were determined (Cohen's κ = 0.98, 0.96, 0.85, respectively). The difference between multiplex and single testing revealed a significant difference for TG2autoAb testing only (McNemar, p = 0.0078). Four CD patients and 4 controls demonstrated TG2autoAb positivity by ELISA but were negative by CytoBead. Further, 140/155 (90.9 %) CD patients demonstrated TG2autoAb levels above ten times the upper normal and all five IgA-deficient samples IgA levels <0.2 g/L by CytoBead. CONCLUSIONS: The novel multiplex CytoBead CeliAK enables simultaneous CD-specific autoAb and IgA deficiency analyses comparable with classical testing by single-parameter assays. Thus, comprehensive CD serology by CytoBead can alleviate the workload in routine laboratories.

7.
Clin Chem Lab Med ; 53(12): 1991-2002, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26020561

RESUMO

BACKGROUND: For the serological diagnosis of systemic autoimmune rheumatic diseases, a two-tier approach starting with sensitive antinuclear antibody (ANA) detection by indirect immunofluorescence (IIF) on HEp-2 cells followed by characterization of positive findings with different immunoassays is recommended. To overcome drawbacks of this approach, we developed a novel technique allowing the combination of screening and simultaneous confirmatory testing. For the first time, this creates the basis for second generation ANA testing. METHODS: ANA and autoantibodies (autoAbs) to double-stranded DNA (dsDNA), CENP-B, SS-A/Ro52, SS-A/Ro60, SS-B/La, RNP-Sm, Sm, and Scl-70 were determined by IIF and enzyme-linked immunosorbent assay (ELISA), respectively, and compared to simultaneous analysis thereof by second generation ANA analysis in patients with systemic lupus erythematosus (n=174), systemic sclerosis (n=103), Sjögren's syndrome (n=46), rheumatoid arthritis (n=36), mixed and undetermined connective tissue diseases (n=13), myositis (n=21), infectious disease (n=21), autoimmune liver disease (n=93), inflammatory bowel disease (n=78), paraproteinemia (n=11), and blood donors (n=101). RESULTS: There was very good agreement of second generation ANA testing with classical one by IIF and ELISA regarding testing for ANA and autoAbs to dsDNA, CENP-B, SS-B, RNP-Sm, Scl-70, SS-A/Ro52, and SS-A/Ro60 (Cohen's κ>0.8). The agreement for anti-Sm autoAb was good (κ=0.77). The differences of both approaches were not significant for autoAbs to SS-B/La, RNP-Sm, Scl-70, SS-A/Ro60, and SS-A/Ro52 (McNemar's test, p>0.05, respectively). CONCLUSIONS: Second generation ANA testing can replace the two-tier analysis by combining IIF screening with multiplex confirmative testing. This addresses shortcomings of classical ANA analysis like false-negative ANA findings and lack of laboratory efficiency and standardization.


Assuntos
Anticorpos Antinucleares/sangue , Doenças Autoimunes/diagnóstico , Imunoensaio , Doenças Reumáticas/diagnóstico , Doenças Autoimunes/sangue , Doenças Autoimunes/imunologia , Técnica Indireta de Fluorescência para Anticorpo , Células Hep G2 , Humanos , Doenças Reumáticas/sangue , Doenças Reumáticas/imunologia
9.
Cytometry A ; 87(8): 724-32, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25845327

RESUMO

The efficacy of many chemotherapeutic agents relies on the preferential destruction of rapidly dividing cancer cells by inducing various kinds of DNA damage. The most deleterious type of DNA lesions are DNA double-strand breaks (DSB), which can be detected by immunofluorescence staining of phosphorylated histone protein H2AX (γH2AX). Furthermore, γH2AX has been suggested as clinical pharmacodynamic biomarker in chemotherapeutic cancer treatment. A great challenge in treating neoplastic diseases is the varying response behavior among cancer patients. Thus, intrinsic or drug-induced overexpression of efflux pumps often leads to multiple drug resistance (MDR) and treatment failure. In particular, inter-individual differences in expression levels of efflux pumps, such as the permeability glycoprotein (P-gp), were shown to correlate with cancer progression. Several efficient cytostatic drugs, including the DSB-inducing agent etoposide (ETP) are known P-gp substrates. In this respect, modulation of MDR by P-gp inhibitors, like the immunosuppressives cyclosporine A (CsA) and rapamycin (Rapa) have been described. Here, we investigated the application of γH2AX focus assay to monitor the impact of CsA and Rapa on ETP-induced cytotoxicity in human peripheral blood mononuclear cells. Evaluation of γH2AX foci was performed by the automated fluorescence microscopy and interpretation system AKLIDES. Compared to ETP treatment alone, our results revealed a significant rise in γH2AX focus number and percentage of DSB-positive cells after cells have been treated with ETP in the presence of either CsA or Rapa. In contrast, DSB levels of cells incubated with CsA or Rapa alone were comparable to focus number of untreated cells. Our results successfully demonstrated how automated γH2AX analysis can be used as fast and reliable approach to monitor drug resistance and the impact of MDR modulators during treatment with DSB-inducing cytostatics..


Assuntos
Citostáticos/farmacologia , Quebras de DNA de Cadeia Dupla/efeitos dos fármacos , DNA/efeitos dos fármacos , Resistência a Múltiplos Medicamentos/efeitos dos fármacos , Histonas/genética , Adulto , Ciclosporina/farmacologia , DNA/genética , Resistência a Múltiplos Medicamentos/genética , Etoposídeo/farmacologia , Feminino , Humanos , Leucócitos Mononucleares/efeitos dos fármacos , Masculino , Microscopia de Fluorescência/métodos , Sirolimo/farmacologia , Adulto Jovem
11.
PLoS One ; 9(9): e107743, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25225805

RESUMO

Anti-neutrophil cytoplasmic antibodies (ANCA) are the serological hallmark of small vessel vasculitis, so called ANCA-associated vasculitis. The international consensus requires testing by indirect immunofluorescence (IIF) on human ethanol-fixed neutrophils (ethN) as screening followed by confirmation with enzyme-linked immunosorbent assays (ELISAs). This study evaluates the combination of cell- and microbead-based digital IIF analysis of ANCA in one reaction environment by the novel multiplexing CytoBead technology for simultaneous screening and confirmatory ANCA testing. Sera of 592 individuals including 118 patients with ANCA-associated vasculitis, 133 with rheumatoid arthritis, 49 with infectious diseases, 77 with inflammatory bowel syndrome, 20 with autoimmune liver diseases, 70 with primary sclerosing cholangitis and 125 blood donors were tested for cytoplasmic ANCA (C-ANCA) and perinuclear ANCA (P-ANCA) by classical IIF and ANCA to proteinase 3 (PR3) and myeloperoxidase (MPO) by ELISA. These findings were compared to respective ANCA results determined by automated multiplex CytoBead technology using ethN and antigen-coated microbeads for microbead immunoassays. There was a good agreement for PR3- and MPO-ANCA and a very good one for P-ANCA and C-ANCA by classical and multiplex analysis (Cohen's kappa [κ] = 0.775, 0.720, 0.876, 0.820, respectively). The differences between classical testing and CytoBead analysis were not significant for PR3-ANCA, P-ANCA, and C-ANCA (p<0.05, respectively). The prevalence of confirmed positive ANCA findings by classical testing (IIF and ELISA) compared with multiplex CytoBead analysis (IIF and microbead immunoassay positive) resulted in a very good agreement (κ = 0.831) with no significant difference of both methods (p = 0.735). Automated endpoint-ANCA titer detection in one dilution demonstrated a very good agreement with classical analysis requiring dilution of samples (κ = 0.985). Multiplexing by CytoBead technology can be employed for simultaneous screening and quantitative confirmation of ANCA. This novel technique provides fast and cost-effective ANCA analysis by automated digital IIF for the first time.


Assuntos
Anticorpos Anticitoplasma de Neutrófilos/imunologia , Vasculite/diagnóstico , Vasculite/imunologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Ensaio de Imunoadsorção Enzimática/métodos , Ensaio de Imunoadsorção Enzimática/normas , Feminino , Técnica Indireta de Fluorescência para Anticorpo/métodos , Técnica Indireta de Fluorescência para Anticorpo/normas , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Valores de Referência , Reprodutibilidade dos Testes , Adulto Jovem
12.
PLoS One ; 9(1): e83924, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24416182

RESUMO

Muscle-specific kinase (MuSK) belongs to the nicotinic acetylcholine receptor complex which is targeted by pathogenic autoantibodies causing Myasthenia gravis. While up to 95% of patients with generalized Myasthenia gravis were shown to be positive for acetylcholine receptor-specific autoantibodies, up to 70% of the remaining patients develop autoantibodies against MuSK. Discrimination of the autoantibody specificity is important for therapy of Myasthenia gravis. Recently, the new automatic fluorescence assessment platform AKLIDES has been developed for immunofluorescence-based diagnostics of autoimmune diseases. In order to establish an AKLIDES procedure for the detection of MuSK-specific autoantibodies (anti-MuSK), we developed a recombinant HEp-2 cell clone expressing the human MuSK cDNA. Here we show at the mRNA and protein level that the cell clone HEp-2 M4 stably expresses human MuSK. We provide evidence for a localization of MuSK at the cell membrane. Using cell clone HEp-2 M4 on the AKLIDES system, we investigated 34 patient sera that were previously tested anti-MuSK positive by radioimmunoassay as positive controls. As negative controls, we tested 29 acetylcholine receptor-positive but MuSK-negative patient sera, 30 amytrophic lateral sclerosis (ALS) patient sera and 45 blood donors. HEp-2 M4 cells revealed a high specificity for the detection of MuSK autoantibodies from 25 patient sera assessed by a specific pattern on HEp-2 M4 cells. By using appropriate cell culture additives, the fraction of cells stained positive with anti-MuSK containing sera can be increased from 2-16% to 10-48%, depending on the serum. In conclusion, we provide data showing that the novel recombinant cell line HEp-2 M4 can be used to screen for anti-MuSK with the automatic AKLIDES system.


Assuntos
Miastenia Gravis/diagnóstico , Miastenia Gravis/enzimologia , Receptores Proteína Tirosina Quinases/metabolismo , Receptores Colinérgicos/metabolismo , Autoanticorpos/sangue , Autoanticorpos/imunologia , Automação , Linhagem Celular , Proliferação de Células , Forma Celular , Imunofluorescência , Humanos , Miastenia Gravis/sangue , Miastenia Gravis/imunologia , Especificidade de Órgãos
14.
Cytometry A ; 83(11): 1017-26, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24009179

RESUMO

Analysis of phosphorylated histone protein H2AX (γH2AX) foci is currently the most sensitive method to detect DNA double-strand breaks (DSB). This protein modification has the potential to become an individual biomarker of cellular stress, especially in the diagnosis and monitoring of neoplastic diseases. To make γH2AX foci analysis available as a routine screening method, different software approaches for automated immunofluorescence pattern evaluation have recently been developed. In this study, we used novel pattern recognition algorithms on the AKLIDES® platform to automatically analyze immunofluorescence images of γH2AX foci and compared the results with visual assessments. Dose- and time-dependent γH2AX foci formation was investigated in human peripheral blood mononuclear cells (PBMCs) treated with the chemotherapeutic drug etoposide (ETP). Moreover, the AKLIDES system was used to analyze the impact of different immunomodulatory reagents on γH2AX foci formation in PBMCs. Apart from γH2AX foci counting the use of novel pattern recognition algorithms allowed the measurement of their fluorescence intensity and size, as well as the analysis of overlapping γH2AX foci. The comparison of automated and manual foci quantification showed overall a good correlation. After ETP exposure, a clear dose-dependent increase of γH2AX foci formation was evident using the AKLIDES as well as Western blot analysis. Kinetic experiments on PBMCs incubated with 5 µM ETP demonstrated a peak in γH2AX foci formation after 4 to 8 h, while a removal of ETP resulted in a strong reduction of γH2AX foci after 1 to 4 h. In summary, this study demonstrated that the AKLIDES system can be used as an efficient automatic screening tool for γH2AX foci analysis by providing new evaluation features and facilitating the identification of drugs which induce or modulate DNA damage.


Assuntos
Técnica Indireta de Fluorescência para Anticorpo , Histonas/isolamento & purificação , Leucócitos Mononucleares/efeitos dos fármacos , Quebras de DNA de Cadeia Dupla/efeitos dos fármacos , Dano ao DNA/efeitos dos fármacos , Dano ao DNA/genética , Etoposídeo/farmacologia , Histonas/sangue , Humanos , Leucócitos Mononucleares/imunologia
15.
PLoS One ; 8(4): e59242, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23658605

RESUMO

We established an automated screening method to characterize adhesion of Escherichia coli to intestinal porcine epithelial cells (IPEC-J2) and their probiotic activity against infection by enteropathogenic E. coli (EPEC). 104 intestinal E. coli isolates from domestic pigs were tested by PCR for the occurrence of virulence-associated genes, genes coding for resistances to antimicrobial agents and metals, and for phylogenetic origin by PCR. Adhesion rates and probiotic activity were examined for correlation with the presence of these genes. Finally, data were compared with those from 93 E. coli isolates from wild boars. Isolates from domestic pigs carried a broad variety of all tested genes and showed great diversity in gene patterns. Adhesions varied with a maximum of 18.3 or 24.2 mean bacteria adherence per epithelial cell after 2 or 6 hours respectively. Most isolates from domestic pigs and wild boars showed low adherence, with no correlation between adhesion/probiotic activity and E. coli genes or gene clusters. The gene sfa/foc, encoding for a subunit of F1C fimbriae did show a positive correlative association with adherence and probiotic activity; however E. coli isolates from wild boars with the sfa/foc gene showed less adhesion and probiotic activity than E. coli with the sfa/foc gene isolated from domestic pigs after 6 hour incubation. In conclusion, screening porcine E. coli for virulence associated genes genes, adhesion to intestinal epithelial cells, and probiotic activity revealed a single important adhesion factor, several probiotic candidates, and showed important differences between E. coli of domestic pigs and wild boars.


Assuntos
Antibiose/genética , Escherichia coli Enteropatogênica/genética , Escherichia coli Enteropatogênica/patogenicidade , Proteínas de Escherichia coli/genética , Escherichia coli/genética , Regulação Bacteriana da Expressão Gênica , Genes Bacterianos , Animais , Animais Selvagens , Aderência Bacteriana/genética , Farmacorresistência Bacteriana/genética , Escherichia coli Enteropatogênica/classificação , Células Epiteliais/citologia , Células Epiteliais/microbiologia , Escherichia coli/classificação , Proteínas de Escherichia coli/classificação , Variação Genética , Ensaios de Triagem em Larga Escala , Mucosa Intestinal/citologia , Mucosa Intestinal/microbiologia , Família Multigênica , Filogenia , Sus scrofa , Suínos , Virulência
17.
Arthritis Res Ther ; 14(6): R271, 2012 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-23241527

RESUMO

INTRODUCTION: Indirect immunofluorescence (IIF) employing ethanol-fixed neutrophils (ethN) is still the method of choice for assessing antineutrophil cytoplasmic antibodies (ANCA) in ANCA-associated vasculitides (AAV). However, conventional fluorescence microscopy is subjective and prone to high variability. The objective of this study was to evaluate novel pattern recognition algorithms for the standardized automated interpretation of ANCA patterns. METHODS: Seventy ANCA-positive samples (20 antimyeloperoxidase ANCA, 50 antiproteinase3 ANCA) and 100 controls from healthy individuals analyzed on ethN and formalin-fixed neutrophils (formN) by IIF were used as a 'training set' for the development of pattern recognition algorithms. Sera from 342 patients ('test set') with AAV and other systemic rheumatic and infectious diseases were tested for ANCA patterns using the novel pattern recognition algorithms and conventional fluorescence microscopy. RESULTS: Interpretation software employing pattern recognition algorithms was developed enabling positive/negative discrimination and classification of cytoplasmic ANCA (C-ANCA) and perinuclear ANCA (P-ANCA). Comparison of visual reading of the 'test set' samples with automated interpretation revealed Cohen's kappa (κ) values of 0.955 on ethN and 0.929 on formN for positive/negative discrimination. Analysis of the 'test set' with regard to the discrimination between C-ANCA and P-ANCA patterns showed a high agreement for ethN (κ = 0.746) and formN (κ = 0.847). There was no significant difference between visual and automated interpretation regarding positive/negative discrimination on ethN and formN, as well as ANCA pattern recognition (P > 0.05, respectively). CONCLUSIONS: Pattern recognition algorithms can assist in the automated interpretation of ANCA IIF. Automated reading of ethN and formN IIF patterns demonstrated high consistency with visual ANCA assessment.


Assuntos
Vasculite Associada a Anticorpo Anticitoplasma de Neutrófilos/sangue , Vasculite Associada a Anticorpo Anticitoplasma de Neutrófilos/diagnóstico , Anticorpos Anticitoplasma de Neutrófilos/sangue , Técnica Indireta de Fluorescência para Anticorpo/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Processamento Eletrônico de Dados , Feminino , Humanos , Masculino , Microscopia de Fluorescência , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Software , Adulto Jovem
18.
Autoimmun Rev ; 11(11): 821-6, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23006529

RESUMO

Detection of anti-phospholipid (aPL) antibodies for state-of-the art diagnosis of antiphospholipid syndrome(APS) still remains a laboratory challenge due to the great diversity of aPL antibodies and their relevance with regard to the diagnostic criteria. According to the recently revised classification criteria for APS, several enzyme-linked immunosorbent assays (ELISAs) should be performed simultaneously in routine laboratories for the detection of aPL antibodies. Therefore, new approaches to aPL profiling have been proposed recently to provide information regarding diagnosis and eventually outcome in APS patients. Multiplex analysis could meet the increasing demand for cost-efficient detection and profiling of aPL antibodies. Multi-line immunodot assays or bead-based multiplex techniques candidate as alternatives to assess several aPL antibodies simultaneously employing different solid-phases for bound/free separation of reactants. Particularly, multi-line immunodot assays present an alternative to ELISA for aPL antibody detection and profiling in APS patients. The use of hydrophobic membranes as solid-surface by this technique appears to offer a distinct solid-phase reaction environment for the assessment of aPL antibodies. This article reviews novel developments in the field of laboratory diagnostics of APS with special emphasis on multiplex assays.


Assuntos
Anticorpos Antifosfolipídeos/sangue , Síndrome Antifosfolipídica/diagnóstico , Anticorpos Antifosfolipídeos/imunologia , Síndrome Antifosfolipídica/classificação , Síndrome Antifosfolipídica/imunologia , Humanos , Testes Imunológicos/métodos , Testes Imunológicos/normas
19.
Int J Radiat Biol ; 88(5): 439-47, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22280362

RESUMO

PURPOSE: Assessment of phosphorylated histone H2AX (γH2AX) foci as a measure for double-strand breaks (DSB) is a common technique. Since visual interpretation is time-consuming and influenced by subjective factors, we adapted the pattern recognition algorithms of autoantibodies to automated reading of γH2AX foci. MATERIALS AND METHODS: DSB formation was assessed by detection of γH2AX foci after exposition of thyreocyte rat cell line to (188)Re. We used pattern recognition algorithms of the automated fluorescence interpretation system AKLIDES(®) for evaluation of γH2AX foci. Manual investigation was performed by three laboratories involving five observers. The results were compared by determining correlation and inter-laboratory variability. RESULTS: The study confirmed the adaptation of automated interpretation system AKLIDES® to automated assessment of γH2AX foci in irradiated cells. Both manual and automated quantification resulted in increasing focus numbers depending on dose. Comparison of automated reading with visual assessment for five manual observers resulted in a determination coefficient of R(2) = 0.889. The inter-laboratory variability for five manual investigators of three laboratories was 38.4 %. CONCLUSION: The interpretation system AKLIDES(®) demonstrated a high correlation with visually observed results. High inter-laboratory variability found for manual investigations revealed the usefulness for a standardized technique for evaluation of γH2AX foci.


Assuntos
Quebras de DNA de Cadeia Dupla/efeitos da radiação , Histonas/metabolismo , Processamento de Imagem Assistida por Computador/métodos , Reconhecimento Automatizado de Padrão/métodos , Animais , Automação , Partículas beta/efeitos adversos , Linhagem Celular , Ratos , Glândula Tireoide/citologia , Glândula Tireoide/metabolismo , Glândula Tireoide/efeitos da radiação
20.
Clin Dev Immunol ; 2012: 284740, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23316252

RESUMO

Antibody assessment is an essential part in the serological diagnosis of autoimmune diseases. However, different diagnostic strategies have been proposed for the work up of sera in particular from patients with systemic autoimmune rheumatic disease (SARD). In general, screening for SARD-associated antibodies by indirect immunofluorescence (IIF) is followed by confirmatory testing covering different assay techniques. Due to lacking automation, standardization, modern data management, and human bias in IIF screening, this two-stage approach has recently been challenged by multiplex techniques particularly in laboratories with high workload. However, detection of antinuclear antibodies by IIF is still recommended to be the gold standard method for antibody screening in sera from patients with suspected SARD. To address the limitations of IIF and to meet the demand for cost-efficient autoantibody screening, automated IIF methods employing novel pattern recognition algorithms for image analysis have been introduced recently. In this respect, the AKLIDES technology has been the first commercially available platform for automated interpretation of cell-based IIF testing and provides multiplexing by addressable microbead immunoassays for confirmatory testing. This paper gives an overview of recently published studies demonstrating the advantages of this new technology for SARD serology.


Assuntos
Autoanticorpos/química , Autoanticorpos/imunologia , Doenças Autoimunes/diagnóstico , Doenças Autoimunes/imunologia , Técnica Indireta de Fluorescência para Anticorpo/métodos , Testes Sorológicos/métodos , Técnica Indireta de Fluorescência para Anticorpo/instrumentação , Humanos , Testes Sorológicos/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...