1.
Phys Imaging Radiat Oncol ; 29: 100558, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38405429

RESUMO

We characterized the on-board megavoltage imager (MVI) of a magnetic resonance-guided radiotherapy machine for beam output checks. Linearity and repeatability of its dose response were investigated. Alignment relative to the beam under clinical circumstances was evaluated for a year using daily measurements. Linearity and short-term repeatability were excellent. Long-term repeatability drifted 0.8 % per year, which can be overcome by monthly cross calibrations. Long-term alignment was stable. Thus, the MVI has suitable characteristics for beam output checks.

2.
Phys Med Biol ; 69(7)2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38412538

RESUMO

Objective.The Elekta unity MR-linac delivers step-and-shoot intensity modulated radiotherapy plans using a multileaf collimator (MLC) based on the Agility MLC used on conventional Elekta linacs. Currently, details of the physical Unity MLC and the computational model within its treatment planning system (TPS)Monacoare lacking in published literature. Recently, a novel approach to characterize the physical properties of MLCs was introduced using dynamic synchronous and asynchronous sweeping gap (aSG) tests. Our objective was to develop a step-and-shoot version of the dynamic aSG test to characterize the Unity MLC and the computational MLC models in theMonacoandRayStationTPSs.Approach.Dynamic aSG were discretized into a step-and-shoot aSG by investigating the number of segments/sweep and the minimal number of monitor units (MU) per segment. The step-and-shoot aSG tests were compared to the dynamic aSG tests on a conventional linac at a source-to-detector distance of 143.5 cm, mimicking the Unity configuration. the step-and-shoot aSG tests were used to characterize the Unity MLC through measurements and dose calculations in both TPSs.Main results.The step-and-shoot aSGs tests with 100 segments and 5 MU/segment gave results very similar to the dynamic aSG experiments. The effective tongue-and-groove width of the Unity gradually increased up to 1.4 cm from the leaf tip end. The MLC models inRayStationandMonacoagreed with experimental data within 2.0% and 10%, respectively. The largest discrepancies inMonacowere found for aSG tests with >10 mm leaf interdigitation, which are non-typical for clinical plans.Significance.The step-and-shoot aSG tests accurately characterize the MLC in step-and-shoot delivery mode. The MLC model inRayStation2023B accurately describes the tongue-and-groove and leaf tip effects whereasMonacooverestimates the tongue-and-groove shadowing further away from the leaf tip end.


Assuntos
Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Aceleradores de Partículas , Radiometria/métodos
3.
Phys Imaging Radiat Oncol ; 29: 100523, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38187170

RESUMO

Background and purpose: This work reports on the results of a survey performed on the use of computed tomography (CT) imaging for motion management, surface guidance devices, and their quality assurance (QA). Additionally, it details the collected user insights regarding professional needs in CT for radiotherapy. The purpose of the survey is to understand current practice, professional needs and future directions in the field of fan-beam CT in radiation therapy (RT). Materials and methods: An online institutional survey was conducted between 1-Sep-2022 and 10-Oct-2022 among medical physics experts at Belgian and Dutch radiotherapy institutions, to assess the current status, challenges, and future directions of motion management and surface image-guided radiotherapy. The survey consisted of a maximum of 143 questions, with the exact number depending on participants' responses. Results: The response rate was 66 % (31/47). Respiratory management was reported as standard practice in all but one institution; surface imaging during CT-simulation was reported in ten institutions. QA procedures are applied with varying frequencies and methodologies, primarily with commercial anatomy-like phantoms. Surface guidance users report employing commercial static and dynamic phantoms. Four main subjects are considered clinically important by the respondents: surface guidance, CT protocol optimisation, implementing gated imaging (4DCT, breath-hold), and a tattoo-less workflow. Conclusions: The survey highlights the scattered pattern of QA procedures for respiratory motion management, indicating the need for well-defined, unambiguous, and practicable guidelines. Surface guidance is considered one of the most important techniques that should be implemented in the clinical radiotherapy simulation workflow.

4.
Phys Imaging Radiat Oncol ; 29: 100522, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38152701

RESUMO

Background and purpose: To obtain an understanding of current practice, professional needs and future directions in the field of fan-beam CT in RT, a survey was conducted. This work presents the collected information regarding the use of CT imaging for dose calculation and structure delineation. Materials and methods: An online institutional survey was distributed to medical physics experts employed at Belgian and Dutch radiotherapy institutions to assess the status, challenges, and future directions of QA practices for fan-beam CT. A maximum of 143 questions covered topics such as CT scanner availability, CT scanner specifications, QA protocols, treatment simulation workflow, and radiotherapy dose calculation. Answer forms were collected between 1-Sep-2022 and 10-Oct-2022. Results: A 66 % response rate was achieved, yielding data on a total of 58 CT scanners. For MV photon therapy, all single-energy CT scans are reconstructed in Hounsfield Units for delineation or dose calculation, and a direct- or stoichiometric method was used to convert CT numbers for dose calculation. Limited use of dual-energy CT is reported for photon (N = 3) and proton dose calculations (N = 1). For brachytherapy, most institutions adopt water-based dose calculation, while approximately 26 % of the institutions take tissue heterogeneity into account. Commissioning and regular QA include eleven tasks, which are performed by two or more professions (29/31) with varying frequencies. Conclusions: Dual usage of a planning CT limits protocol optimization for both tissue characterization and delineation. DECT has been implemented only gradually. A variation of QA testing frequencies and tests are reported.

5.
Phys Imaging Radiat Oncol ; 25: 100411, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36687506

RESUMO

Beam output checks of a commercial high-field magnetic resonance-guided radiotherapy machine can be performed with its on-board megavoltage imager (MVI). This is a fast and efficient method, but only recommended for daily checks. The aim of our study was to show its suitability for weekly checks by investigating its long-term agreement with the golden standard: ionization chamber measurements in a water tank. For one year, the output deviations obtained with both methods were compared. The difference was 0.1 ± 0.3 (1SD) percentage point. This indicated an excellent agreement, and translated into a tolerance level of ± 2 %.

6.
Brachytherapy ; 21(2): 208-215, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35090830

RESUMO

PURPOSE: To accurately quantify local seed displacement from Day 0 to Day 30 for our brachytherapy procedure. To quantify seed loss/migration and to identify the locations from where seeds are missing. METHODS AND MATERIALS: Seed displacements were analyzed in 62 consecutive patients, who received brachytherapy with stranded I-125 seeds. At the start of the procedure, four fiducial gold markers were implanted. At the end of the implantation procedure an in-room 3D CBCT scan (Day 0) was acquired for accurate seed localization. At Day 30 a regular CT scan was acquired. This CT scan was rigidly registered to the CBCT scan using the fiducials. Subsequently, the Hungarian method was used to find pairs of corresponding seeds. Displacements were calculated and missing seeds were identified. RESULTS: Local seed displacements are smaller than 5 mm for 76.3% of the seeds; 2.3% show displacements larger than 10 mm. The largest seed displacements are seen along the inferior-superior axis: on average 1.0 ± 3.2 mm in superior direction with respect to the intraprostatic fiducials. Largest displacements are seen at the inferior-lateral sides of the prostate. On average, the inferior seeds move 1.0 ± 2.8 mm in anterior and 1.8 ± 3.3 mm in superior direction. The percentage of missing seeds is 0.2% (8 out of 3893 seeds for 5 patients). Most of the missing seeds were also originally implanted at the inferior-lateral sides of the prostate. CONCLUSIONS: Local seed displacements and number of missing seeds are small, and predominantly occur around the apex.


Assuntos
Braquiterapia , Neoplasias da Próstata , Braquiterapia/métodos , Humanos , Radioisótopos do Iodo/uso terapêutico , Masculino , Próstata , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Radiometria/métodos , Tomografia Computadorizada por Raios X
7.
J Appl Clin Med Phys ; 16(3): 5111, 2015 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-26103476

RESUMO

In external beam radiotherapy treatment planning for patients with thoracic malignancies, respiratory-correlated CT (4D CT) is used to obtain high quality studies in the presence of respiratory motion. When helical 4D CT scans are acquired with a Brilliance CT Big Bore, the pitch must meet two conditions. It must be low enough to avoid motion artifacts, and high enough to cover the entire scan length within 120 s to prevent overheating of the X-ray tube. We developed a nomogram that can be used to obtain a suitable pitch satisfying both requirements. We also assessed the effects on the image quality of a pitch that exceeds the maximum pitch, and of a field of view (FOV) reduction. It was shown that, for AVG and MIP reconstructions, the manufacturer's maximum pitch equation yields an underestimation due to its FOV term.


Assuntos
Algoritmos , Tomografia Computadorizada Quadridimensional/métodos , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Tomografia Computadorizada Espiral/métodos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
J Appl Clin Med Phys ; 15(1): 4597, 2014 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-24423859

RESUMO

Philips Healthcare released a novel metal artifact reduction algorithm for large orthopedic implants (O-MAR). Little information was available about its CT number accuracy. Since CT numbers are used for tissue heterogeneity corrections in external beam radiotherapy treatment planning, we performed a phantom study to assess the CT number accuracy of O-MAR. Two situations were simulated: a patient with a unilateral metallic hip prosthesis and a patient with bilateral metallic hip prostheses. We compared the CT numbers in the O-MAR reconstructions of the simulations to those in the nonO-MAR reconstruction and to those in a metal-free baseline reconstruction. In both simulations, the CT number accuracy of the O-MAR reconstruction was better than the CT number accuracy of the nonO- MAR reconstruction. In the O-MAR reconstruction of the unilateral simulation, all CT numbers were accurate within ± 5 HU (AAPM criterion). In the O-MAR reconstruction of the bilateral simulation, CT numbers were found that differed more than ± 5 HU from the metal-free baseline values. However, none of these differences were clinically relevant.


Assuntos
Algoritmos , Prótese de Quadril , Metais , Próteses e Implantes , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Artefatos , Simulação por Computador , Humanos , Imagens de Fantasmas