1.
Heart Vessels ; 36(3): 408-413, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32951086

RESUMO

Rates of permanent pacemaker (PPM) implantation following transcatheter aortic valve implantation (TAVI) are higher than following surgery and are dependent on patient factors and valve type. There is an increasing trend towards pre-emptive PPM insertion in patients with significant conduction disease prior to TAVI. We report results from the British Cardiovascular Intervention Society (BCIS) on pre- and post-procedural PPM implantation in the TAVI population. All centres in the United Kingdom performing TAVI are required to submit data on all TAVI procedures to the National database which are then reported annually. During 2015, there were 2373 TAVI procedures in the UK. 22.4% of TAVI patients had a PPM implanted either pre-procedure (including the distant past), or during the in-hospital procedural episode. Of these, 7.9% were pre-procedure and 14.5% post-procedure. Overall PPM rates were Edwards Sapien (13.5%), Medtronic CoreValve (28.2%) and Boston Lotus (42.1%; p < 0.01). Pre-procedure pacing rates were Edwards Sapien (6.0%), Medtronic CoreValve (9.1%) and Boston Lotus (12.3%; p < 0.01). Pre-procedural pacing rates for the Boston Lotus valve have risen year-on-year from 5.8% (2013) to 8.6% (2014) to 12.3% (2015). The UK TAVI Registry demonstrates a pre-procedural permanent pacing bias amongst patients receiving transcatheter valves with higher post-procedure pacing rates. Pre-emptive permanent pacing is likely to be responsible for this difference.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bloqueio de Ramo/terapia , Eletrocardiografia , Cuidados Pré-Operatórios/métodos , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico , Bloqueio de Ramo/complicações , Bloqueio de Ramo/fisiopatologia , Estimulação Cardíaca Artificial , Feminino , Seguimentos , Humanos , Masculino , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Reino Unido
2.
Catheter Cardiovasc Interv ; 90(2): E62-E67, 2017 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-27084789

RESUMO

Percutaneous closure of paravalvular leaks is becoming a more widely practiced technique. We describe the technique we used to deploy an Amplatzer PFO closure device to treat a prosthetic mitral paravalvular leak. The procedure was performed under real time 3D trans-oesophageal echo and fluoroscopic guidance requiring a trans-septal puncture and utilising an 035″ Safari wire which was developed for TAVR implantation. An excellent result was achieved acutely and at 4 month follow-up. © 2016 Wiley Periodicals, Inc.


Assuntos
Cateterismo Cardíaco/instrumentação , Insuficiência da Valva Mitral/terapia , Valva Mitral/fisiopatologia , Dispositivo para Oclusão Septal , Idoso de 80 Anos ou mais , Ecocardiografia Doppler em Cores , Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Hemodinâmica , Humanos , Masculino , Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/fisiopatologia , Desenho de Prótese , Radiografia Intervencionista , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS