Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Optom Vis Sci ; 89(11): 1590-600, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23080060

RESUMO

PURPOSE: We examined the spatial correlation between tear breakup (TBU) and the associated optical anomalies on multiple spatial scales. METHODS: Five subjects refrained from blinking while the time course and patterns of TBU were sequentially observed using fluorescein, retroillumination, and Shack-Hartmann (SH) aberrometry. Wavefront error maps were developed using Zernike polynomials, as well as local zonal analysis of measured wavefront slopes. The difference between these maps reveals the presence of very high-order aberrations missed by standard modal fitting methods. Size of SH spots was also quantified to estimate optical perturbations on a microscopic scale. The spatial correlation between TBU and optical aberrations was also computed. RESULTS: Degradation of the tear film increased wavefront aberrations over all spatial scales measured. Consistent with tear thinning, blink suppression induced an irregular pattern of phase advances in regions of TBU. SH spot size also increased in regions of TBU, which indicates the presence of optical aberrations on a scale smaller than individual lenslets. CONCLUSIONS: The optical signature of TBU caused by blink suppression is a combination of wavefront aberrations on macroscopic and microscopic scales due to non-uniform tear film thinning and possible exposure of a rough epithelial surface. Localized optical defects correspond temporally and spatially with TBU revealed by fluorescein and retroillumination. In addition to gross wavefront aberrations, scatter develops in areas of TBU that will further contribute to image degradation and visual disturbances after TBU.


Assuntos
Aberrometria/métodos , Piscadela/fisiologia , Córnea/metabolismo , Aberrações de Frente de Onda da Córnea/diagnóstico , Lágrimas/metabolismo , Adulto , Córnea/patologia , Topografia da Córnea , Aberrações de Frente de Onda da Córnea/metabolismo , Aberrações de Frente de Onda da Córnea/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
2.
Vision Res ; 51(17): 1932-40, 2011 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-21777601

RESUMO

We seek unbiased methods for estimating the target vergence required to maximize visual acuity based on wavefront aberration measurements. Experiments were designed to minimize the impact of confounding factors that have hampered previous research. Objective wavefront refractions and subjective acuity refractions were obtained for the same monochromatic wavelength. Accommodation and pupil fluctuations were eliminated by cycloplegia. Unbiased subjective refractions that maximize visual acuity for high contrast letters were performed with a computer controlled forced choice staircase procedure, using 0.125 diopter steps of defocus. All experiments were performed for two pupil diameters (3mm and 6mm). As reported in the literature, subjective refractive error does not change appreciably when the pupil dilates. For 3mm pupils most metrics yielded objective refractions that were about 0.1D more hyperopic than subjective acuity refractions. When pupil diameter increased to 6mm, this bias changed in the myopic direction and the variability between metrics also increased. These inaccuracies were small compared to the precision of the measurements, which implies that most metrics provided unbiased estimates of refractive state for medium and large pupils. Thus a variety of image quality metrics may be used to determine ocular refractive state for monochromatic (635nm) light, thereby achieving accurate results without the need for empirical correction factors.


Assuntos
Aberrações de Frente de Onda da Córnea/fisiopatologia , Refração Ocular/fisiologia , Aberrometria/métodos , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Acuidade Visual/fisiologia , Adulto Jovem
3.
Opt Express ; 19(8): 7417-38, 2011 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-21503052

RESUMO

An optical analysis is developed to separate forward light scatter of the human eye from the conventional wavefront aberrations in a double pass optical system. To quantify the separate contributions made by these micro- and macro-aberrations, respectively, to the spot image blur in the Shark-Hartmann aberrometer, we develop a metric called radial variance for spot blur. We prove an additivity property for radial variance that allows us to distinguish between spot blurs from macro-aberrations and micro-aberrations. When the method is applied to tear break-up in the human eye, we find that micro-aberrations in the second pass accounts for about 87% of the double pass image blur in the Shack-Hartmann wavefront aberrometer under our experimental conditions.


Assuntos
Luz , Fenômenos Fisiológicos Oculares , Óptica e Fotônica , Espalhamento de Radiação , Algoritmos , Simulação por Computador , Desenho de Equipamento , Humanos , Modelos Estatísticos , Dispositivos Ópticos , Lágrimas , Visão Ocular
4.
Optom Vis Sci ; 87(5): 350-7, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20351601

RESUMO

PURPOSE: To study the effect of extrinsic controls on blinking by examining blink parameters and tear stability among adapted soft contact lens (CL) wearers performing tasks that require varying amounts of visual concentration. METHODS: The Demographic Questionnaire, Contact Lens Dry Eye Questionnaire, and Current Symptoms Questionnaire were completed by 15 adapted soft CL wearers (nine females). Three 55 s simultaneous measurements of tear film stability via retroillumination and blinking were obtained with a slit-lamp biomicroscope and 200 Hz video camera while subjects listened to music and played a video game with and without their habitual CLs. Interblink interval (IBI) and blink amplitude (BA) were calculated. The area of break-up (AB) was calculated for the retroillumination image before each blink. The Current Symptoms Questionnaire was completed four times throughout testing. RESULTS: With the game compared to music, IBI was significantly longer and BA significantly decreased without CLs (p < or = 0.001). With CLs, the IBI did not significantly change between tasks but the BA significantly decreased (p = 0.100). The AB significantly increased with CL and the game (paired t-test, p < or = 0.001). The BA was significantly correlated with self-reported severity of dry eye for all testing scenarios (Spearman r > or = 0.5579, p < 0.0001) and several symptom measures (Spearman r > or = 0.6262, p < 0.0001). The AB was significantly correlated with symptom measures including bothersome discomfort for the game with and without CLs (Spearman r > or = 0.5064, p < 0.0001). CONCLUSIONS: During tasks requiring concentration, the IBI increased (blink rate decreased) and many blinks were incomplete without CLs. With CLs, tear film instability increased. Blinking frequency also increased, but it remained high when subjects played the game, and symptoms of ocular irritation increased. This suggests that wearing soft CLs, even when fully adapted, provides enough extrinsic ocular surface stimulation to override internal controls and affect blink parameters.


Assuntos
Piscadela/fisiologia , Lentes de Contato Hidrofílicas , Síndromes do Olho Seco/reabilitação , Análise e Desempenho de Tarefas , Lágrimas/metabolismo , Testes Visuais/métodos , Percepção Visual/fisiologia , Adolescente , Adulto , Síndromes do Olho Seco/metabolismo , Síndromes do Olho Seco/fisiopatologia , Feminino , Seguimentos , Humanos , Masculino , Microscopia Acústica , Estimulação Luminosa , Inquéritos e Questionários , Gravação em Vídeo , Adulto Jovem
5.
Optom Vis Sci ; 86(2): E106-14, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19156014

RESUMO

PURPOSE: This study investigates the relationship between blinking, tear film break-up, and ocular symptoms for normal and dry eye subjects performing four different visual tasks. METHODS: Sixteen control and sixteen dry eye subjects performed four visual tasks (looking straight ahead, watching a movie, identifying rapidly changing letters, and playing a computer game) while blink patterns and fluorescein images of the tear film were videotaped. Pre and posttesting symptom questionnaires, querying the intensity of nine symptoms of ocular irritation, were completed by all subjects. Blink rate and blink amplitude were computed from digitized videos. The percentage of tear film break-up before the blink was calculated. RESULTS: Dry eye subjects had a significantly higher blink rate (p = 0.017, t-test). Both groups blinked significantly less during the game and letter tasks (p < 0.04, t-test). Partial blinks were common as were clusters or "flurries" of rapid blinks, but there was no significant difference in blink amplitude for control and dry eye subjects. Tear film break-up in normal subjects was typically inferior; whereas dry eye subjects showed more tear break-up centrally and superiorly. Real-time video recording of tear break-up and blink behavior pointed to complex interaction between the two. Dry eye subjects shifted more toward intense ocular symptoms at posttesting (p < 0.05, Wilcoxon signed rank) than controls. Both groups showed a shift toward more corneal staining at posttesting (p < 0.05, Wilcoxon signed rank), which was typically inferior. CONCLUSIONS: Reduced and incomplete blinking along with increased tear film break-up during normal visual tasks may explain the increased level of ocular discomfort symptoms reported at the end of the day, particularly in dry eye patients.


Assuntos
Piscadela/fisiologia , Síndromes do Olho Seco/fisiopatologia , Lágrimas/metabolismo , Testes Visuais/métodos , Adolescente , Adulto , Idoso , Síndromes do Olho Seco/diagnóstico , Síndromes do Olho Seco/metabolismo , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Gravação em Vídeo , Adulto Jovem
6.
Optom Vis Sci ; 83(1): 15-21, 2006 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-16432468

RESUMO

PURPOSE: The purpose of this study was to develop a novel, quantitative measurement of tear film breakup dynamics (TBUD) to study the phenomenon of tear breakup in dry eye and control subjects and its impact on dry eye symptoms. METHODS: Ten control and 10 dry eye subjects completed the Dry Eye (DEQ) and other questionnaires. After the instillation of sodium fluorescein, subjects kept the tested eye open for as long as possible, similar to a staring contest, while tear film breakup was videotaped (S-TBUD). The maximum blink interval (MBI) and tear breakup time (TBUT) were measured from digital movies by a masked observer. Individual frames of movies were converted to gray-scale images, maps of relative tear film fluorescence were generated, and the total area of tear breakup (AB) of the exposed cornea was quantified. RESULTS: On average, dry eye subjects demonstrated a higher AB and shorter TBUT and MBI, but only the AB was significantly different (p = 0.023). Subjects most often used the descriptors stinging and burning to describe their sensations during staring trials. The AB showed a high correlation between eyes and with some DEQ symptom measures. CONCLUSIONS: These methods allow objective quantification and tracking of the phenomenon of tear breakup. Our results suggest that tear breakup stresses the corneal surface, resulting in stimulation of underlying nociceptors. The tear film of dry eye subjects was less stable than controls. They had a larger AB measured from the last video frame before MBI (i.e., just before blinking) than did controls. This perhaps reflects adaptation to the repeated stress of tear instability in dry eye.


Assuntos
Síndromes do Olho Seco/metabolismo , Lágrimas/fisiologia , Adulto , Piscadela/fisiologia , Meios de Contraste/administração & dosagem , Córnea/metabolismo , Síndromes do Olho Seco/fisiopatologia , Feminino , Fluoresceína/administração & dosagem , Humanos , Masculino , Pessoa de Meia-Idade , Soluções Oftálmicas , Inquéritos e Questionários , Gravação em Vídeo
7.
Invest Ophthalmol Vis Sci ; 45(1): 351-60, 2004 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-14691194

RESUMO

PURPOSE: To evaluate the stability of clinical monochromatic aberrometry measurements over a wide range of time scales. METHODS: Monochromatic aberrations in four normal eyes were measured with a clinical Shack-Hartmann aberrometer. A chin rest or a supplemental bite bar attachment was used to stabilize head and eye position. Five repeated measurements were taken within one test (5 frames, t < 1 second) without realignment. With realignment between each measurement, aberration measurements were repeated five times (t < 1 hour) on each day, at the same time of day on five consecutive days, and again on 5 days at monthly intervals. A control experiment studied the effect of systematically misaligning the eye to determine whether fixation errors can account for the variation in the repeated measurements. RESULTS: Variability of wavefront root mean square (RMS) error (excluding defocus and astigmatism) was tracked across repeated measurements. Variances for different time scales were: 8.10 x 10(-5) microm2 (t < 1 second), 3.24 x 10(-4) microm2 (t < 1 hour), 4.41 x 10(-4) microm2 (t < 1 week), 9.73 x 10(-4) microm2 (t < 1 year). Bite bar and chin rest data were almost identical. Rotational fixation error up to 3 degrees accounts for only part of the variability. CONCLUSIONS: Increased variability in aberration maps between days and months indicates biological fluctuations that are large enough to prevent achievement of "perfect vision," even in the unlikely event that spherical and astigmatic refractive errors are corrected perfectly. However, lack of stability does not justify withholding treatment. A lasting benefit of aberration correction is expected despite temporal variability.


Assuntos
Erros de Refração/diagnóstico , Transtornos da Visão/diagnóstico , Seleção Visual/instrumentação , Adolescente , Adulto , Fixação Ocular , Humanos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
8.
Optom Vis Sci ; 80(8): 587-95, 2003 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-12917578

RESUMO

PURPOSE: To validate the accuracy, tolerance, and repeatability of the complete ophthalmic analysis system aberrometer (COAS, Wavefront Sciences Inc.) with model eyes and normal human eyes. METHOD: Model eyes were constructed from six polymethyl methacrylate, single-surface lenses with known characteristics. Accuracy of second-order aberrations was verified by measuring defocus and astigmatism induced by series of spherical and cylindrical trial lenses. Accuracy of higher-order aberrations was evaluated by comparing ray-tracing predictions with measured spherical aberration and coma of the aspheric model eyes. Tolerance to axial and lateral misalignment was measured by controlled displacements of the model eye relative to the aberrometer. Repeatability was tested on the same model eyes with repeated measurements taken within 1 s or within half an hour with realignment between each trial. Analyses were based on a 5-mm pupil diameter. RESULTS: Defocus and astigmatism were accurately measured within the working range of the instrument automatic focus adjustment (e.g., measured defocus was within +/-0.25 diopters over a -6.50 to +3.00 D range of refractive error). Accuracy of spherical aberration and coma agreed closely with theoretical predictions (e.g., for all six aspheric models, the mean absolute difference between predicted and measured Z(4)0 was 0.007 microm). Axial displacements over the range +/-2.5 mm had little effect on measurements for myopic and emmetropic model eyes. Also, lateral displacements over the range +/-1.5 mm did not produce significant coma. The standard deviations of repeated measurements of higher-order root mean square on model eyes were <1% of the mean with repeated measures within 1 s and 10% of the mean for five individual measurements with realignment in between each. Tolerance to small lateral displacements was also observed for human eyes. CONCLUSION: The complete ophthalmic analysis system aberrometer can measure second-, third-, and fourth-order aberrations accurately and repeatedly on model eyes.


Assuntos
Erros de Refração/diagnóstico , Seleção Visual/instrumentação , Astigmatismo/diagnóstico , Fixação Ocular , Humanos , Modelos Teóricos , Reprodutibilidade dos Testes
9.
Optom Vis Sci ; 80(1): 69-78, 2003 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-12553546

RESUMO

PURPOSE: The aim of the current study was to develop quantitative methods to assess optical aberrations caused by tear film disruption. METHODS: We used standard fluorescein imaging (FL) and a novel retroillumination (RI) method to image tear film disruption in 12 eyes. Using a clinical slit lamp biomicroscope, we alternated between widefield blue and narrow-beam white light to obtain an interleaved series of FL and RI images of the time course and pattern of tear film break-up. We developed an optical analysis that indicates that the RI image should be proportional to the spatial derivative of the FL image. Intensity fluctuations in the RI images are due to thickness changes in the tear film, whereas intensity fluctuations in FL images are directly determined by tear film thickness. RESULTS: As predicted by optical analysis of RI, the spatial distribution of gaps in the tear film seen with fluorescein appeared as pairs of light and dark contours in the RI images, and a precise correspondence between the spatial derivative of the FL image (slope) and the RI image was found. Both methods showed a gradual spreading of the tear disruption during blink suppression that varied tremendously among eyes in both time and spatial pattern. Resumption of normal blinking did not produce an immediate reconstitution of the normal tear film, and areas of tear break-up created during blink suppression remained abnormal for up to several minutes of normal blinking. CONCLUSIONS: Our analysis indicates that both FL and RI have the potential to quantify optical changes occurring during tear break-up. These results support an interpretation of RI as an intensity-based method for mapping the highly irregular optical aberrations of the eye produced by tear film disruption.


Assuntos
Erros de Refração/diagnóstico , Erros de Refração/metabolismo , Lágrimas/metabolismo , Adulto , Feminino , Fluorofotometria/métodos , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...