Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
ACS Appl Nano Mater ; 5(11): 17087-17094, 2022 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-36466301

RESUMO

α-Fe2O3 (hematite) thin films have been shown to be a robust sensor substrate for photoelectrochemical imaging with good stability and high spatial resolution. Herein, one-dimensional (1D) hematite nanorods (NRs) synthesized via a simple hydrothermal method are proposed as a substrate which provides nanostructured surfaces with enhanced photocurrent responses compared to previously described hematite films, good stability, and excellent spatial resolution for potential imaging applications. The photoelectrochemical sensing capability of hematite NRs was demonstrated by a high pH sensitivity without modification. The modification of the hematite NRs with a thin poly(vinyl chloride) (PVC)-based ion-selective film allowed highly reversible amperometric detection of calcium ions with sensor materials traditionally employed in potentiometric devices.

2.
Biosens Bioelectron ; 180: 113121, 2021 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-33706156

RESUMO

Photoelectrochemical imaging has great potential in the label-free investigation of cellular processes. Herein, we report a new fast photoelectrochemical imaging system (PEIS) for DC photocurrent imaging of live cells, which combines high speed with excellent lateral resolution and high photocurrent stability, which are all crucial for studying dynamic cellular processes. An analog micromirror was adopted to raster the sensor substrate, enabling high-speed imaging. α-Fe2O3 (hematite) thin films synthesized via electrodeposition were used as a robust substrate with high photocurrent and good spatial resolution. The capabilities of this system were demonstrated by monitoring cell responses to permeabilization with Triton X-100. The ability to carry out dynamic functional imaging of multiple cells simultaneously provides improved confidence in the data than could be achieved with the slower electrochemical single-cell imaging techniques described previously. When monitoring pH changes, the PEIS can achieve frame rates of 8 frames per second.


Assuntos
Técnicas Biossensoriais , Técnicas Eletroquímicas
3.
Bone Joint Res ; 9(6): 293-301, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32728430

RESUMO

AIMS: To evaluate graft healing of decellularized porcine superflexor tendon (pSFT) xenograft in an ovine anterior cruciate ligament (ACL) reconstruction model using two femoral fixation devices. Also, to determine if pSFT allows functional recovery of gait as compared with the preoperative measurements. METHODS: A total of 12 sheep underwent unilateral single-bundle ACL reconstruction using pSFT. Two femoral fixation devices were investigated: Group 1 (n = 6) used cortical suspensory fixation (Endobutton CL) and Group 2 (n = 6) used cross-pin fixation (Stratis ST). A soft screw was used for tibial fixation. Functional recovery was quantified using force plate analysis at weeks 5, 8, and 11. The sheep were euthanized after 12 weeks and comprehensive histological analysis characterized graft healing at the graft-bone interface and the intra-articular graft (ligamentization). RESULTS: The pSFT remodelled into a ligament-like structure and no adverse inflammatory reaction was seen. The ground reaction force in the operated leg of the Endobutton group was higher at 11 weeks (p < 0.05). An indirect insertion was seen at the graft-bone interface characterized by Sharpey-like fibres. Qualitative differences in tendon remodelling were seen between the two groups, with greater crimp-like organization and more aligned collagen fibres seen with Endobutton fixation. One graft rupture occurred in the cross-pin group, which histologically showed low collagen organization. CONCLUSION: Decellularized pSFT xenograft remodels into a ligament-like structure after 12 weeks and regenerates an indirect-type insertion with Sharpey-like fibres. No adverse inflammatory reaction was observed. Cortical suspensory femoral fixation was associated with more enhanced graft remodelling and earlier functional recovery when compared with the stiffer cross-pin fixation.

4.
Mater Sci Eng C Mater Biol Appl ; 80: 207-212, 2017 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-28866158

RESUMO

A comparative investigation was undertaken on 1-2mm sized granules of two forms of synthetic bone graft substitute (SBG) with identical pore structure but varied bulk chemistry, stoichiometric hydroxyapatite (HA) and silicate substituted (0.8wt% Si) hydroxyapatite (SA), to assess the influence of SBG chemistry on the relative affinity of an osteogenic growth factor (GF), recombinant human bone morphogenetic protein-2 (rhBMP-2). A previously described novel fluorescent probe, fluoresceinthioureidoaminocaproic acid (FTCA), was covalently attached to rhBMP-2 to give FTCA-rhBMP-2 and facilitate the quantitative monitoring of GF uptake and release from the two chemistries of SBG. The relative affinity of rhBMP-2 for the HA and SA granules was assessed at a physiologically relevant concentration of 300ngmL-1 from three (increasingly complex) environments; phosphate buffered saline (PBS), minimum Eagles' medium (MEM) and serum supplemented MEM (SCEM) in order to closely mimic clinical bone repair procedures. The results demonstrated that rhBMP-2 affinity to SBGs was highly sensitive to both SBG chemistry and the composition of the local environment. Under the most physiologically relevant competitive conditions of SCEM, rhBMP-2 showed greater affinity to SA (P<0.05) such that 50% of the rhBMP-2 in solution was adsorbed to the SA granules after only 15min, as compared to 30% adsorbed to the HA granules. Subsequent investigation of the desorption of adsorbed GF from the SBGs demonstrated that a significantly higher percentage of the adsorbed rhBMP-2 was desorbed from HA as compared to SA granules. Together, these observations suggested that at physiologically relevant concentrations and conditions, rhBMP-2 has a greater affinity to silicate-substituted hydroxyapatite as compared to stoichiometric hydroxyapatite, which may in part explain the enhanced osteoconductivity and reported osteoinductivity for silicate-substituted hydroxyapatite based SBGs.


Assuntos
Proteína Morfogenética Óssea 2/análise , Fator de Crescimento Transformador beta/análise , Substitutos Ósseos , Fosfatos de Cálcio , Corantes Fluorescentes , Humanos , Proteínas Recombinantes/análise
5.
J Mater Sci Mater Med ; 27(1): 20, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26684617

RESUMO

A synthetic bone graft substitute consisting of silicate-substituted calcium phosphate with increased strut porosity (SiCaP EP) was evaluated in an ovine distal femoral critical sized metaphyseal defect as a standalone bone graft, as an autologous iliac crest bone graft (ICBG) extender (SiCaP EP/ICBG), and when mixed with bone marrow aspirate (SiCaP EP/BMA). Defects were evaluated after 4, 8, and 12 weeks with radiography, decalcified paraffin-embedded histopathology, non-decalcified resin-embedded histomorphometry, and mechanical indentation testing. All test groups exhibited excellent biocompatibility and osseous healing as evidenced by an initial mild inflammatory response followed by neovascularization, bone growth, and marrow infiltration throughout all SiCaP EP-treated defects. SiCaP EP/ICBG produced more bone at early time points, while all groups produced similar amounts of bone at later time points. SiCaP EP/ICBG likewise showed more favorable mechanical properties at early time points, but was equivalent to SiCaP EP and SiCaP EP/BMA at later time points. This study demonstrates that SiCaP EP is efficacious as a standalone bone graft substitute, mixed with BMA, and as an autograft extender.


Assuntos
Substitutos Ósseos , Fosfatos de Cálcio , Modelos Animais de Doenças , Fêmur/cirurgia , Silicatos , Animais , Feminino , Porosidade , Ovinos
6.
J Mater Sci Mater Med ; 27(2): 39, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26704556

RESUMO

Porous bioactive glasses are attractive for use as bone scaffolds. There is increasing interest in strontium containing bone grafts, since strontium ions are known to up-regulate osteoblasts and down regulate osteoclasts. This paper investigates the influence of partial to full substitution of strontium for calcium on the dissolution and phase formation of a multicomponent high phosphate content bioactive glass. The glasses were synthesised by a high temperature melt quench route and ground to a powder of <38 microns. The dissolution of this powder and its ability to form apatite like phases after immersion in Tris buffer (pH 7.4) and simulated body fluid (SBF) was followed by inductively coupled plasma optical emission spectroscopy (ICP), Fourier transform infra red spectroscopy (FTIR), X-ray powder diffraction (XRD) and (31)P solid state nuclear magnetic resonance spectroscopy up to 42 days of immersion. ICP indicated that all three glasses dissolved at approximately the same rate. The all calcium (SP-0Sr-35Ca) glass showed evidence of apatite like phase formation in both Tris buffer and SBF, as demonstrated after 3 days by FTIR and XRD analysis of the precipitate that formed during the acellular dissolution bioactivity studies. The strontium substituted SP-17Sr-17Ca glass showed no clear evidence of apatite like phase formation in Tris, but evidence of an apatite like phase was observed after 7 days incubation in SBF. The SP-35Sr-0Ca glass formed a new crystalline phase termed "X Phase" in Tris buffer which FTIR indicated was a form of crystalline orthophosphate. The SP-35Sr-0Ca glass appeared to support apatite like phase formation in SBF by 28 days incubation. The results indicate that strontium substitution for calcium in high phosphate content bioactive glasses can retard apatite like phase formation. It is proposed that apatite formation with high phosphate bioactive glasses occurs via an octacalcium phosphate (OCP) precursor phase that subsequently transforms to apatite. The equivalent octa-strontium phosphate does not exist and consequently in the absence of calcium, apatite formation does not occur. The amount of strontium that can be substituted for calcium in OCP probably determines the amount of strontium in the final apatite phase and the speed with which it forms.


Assuntos
Materiais Biocompatíveis/síntese química , Fosfatos de Cálcio/química , Vidro/química , Estrôncio/química , Alicerces Teciduais/química , Materiais Biocompatíveis/química , Líquidos Corporais/química , Fosfatos de Cálcio/farmacologia , Humanos , Espectroscopia de Ressonância Magnética , Pós , Espectroscopia de Infravermelho com Transformada de Fourier , Engenharia Tecidual , Difração de Raios X
7.
J Biomed Mater Res A ; 102(3): 647-54, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23554092

RESUMO

Bioactive glasses are used clinically for bone regeneration, and their bioactivity and cell compatibility are often characterized in vitro, using physiologically relevant test solutions. The aim of this study was to show the influence of varying medium characteristics (pH, composition, presence of proteins) on glass dissolution and apatite formation. The dissolution behavior of a fluoride-containing bioactive glass (BG) was investigated over a period of one week in Eagle's Minimal Essential Medium with Earle's Salts (MEM), supplemented with either, (a) acetate buffer, (b) 4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid (HEPES) buffer, (c) HEPES + carbonate, or (d) HEPES + carbonate + fetal bovine serum. Results show pronounced differences in pH, ion release, and apatite formation over 1 week: Despite its acidic pH (pH 5.8 after BG immersion, as compared to pH 7.4-8.3 for HEPES-containing media), apatite formation was fastest in acetate buffered (HEPES-free) MEM. Presence of carbonate resulted in formation of calcite (calcium carbonate). Presence of serum proteins, on the other hand, delayed apatite formation significantly. These results confirm that the composition and properties of a tissue culture medium are important factors during in vitro experiments and need to be taken into consideration when interpreting results from dissolution or cell culture studies.


Assuntos
Materiais Biocompatíveis/química , Meios de Cultura/química , Fluoretos/química , Vidro/química , Concentração de Íons de Hidrogênio , Solubilidade
9.
Langmuir ; 29(5): 1420-6, 2013 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-23259749

RESUMO

In this article, a method to analyze protein adsorption on porous, clinically relevant samples under physiologically relevant conditions is described. The use of fluorescent probes was identified as a methodology that would facilitate analysis under a range of conditions including fully competitive conditions where a protein of interest may be labeled in isolation and then allowed to compete with unlabeled proteins on samples that require no specialized surface pretreatment. As a first step, this article describes the covalent labeling of isolated bovine serum albumin (BSA) with fluorescent fluoresceinthioureidoaminocaproic acid, FTCA, giving FTCA-BSA. The fluorescence intensity of FTCA-BSA was then used to monitor the adsorption and desorption of the protein under noncompetitive conditions with two forms of hydroxyapatite discs (silicate-substituted, SA and stoichiometric, HA) in phosphate-buffered saline (PBS) and minimum essential Eagles' medium (MEM). Noncompetitive conditions were used to facilitate the validation of the technique in which data obtained from these experiments were corroborated against data obtained using an established total protein assay method (Quant-IT kit, Invitrogen). These experiments demonstrated that the FTCA-BSA probe had several advantages including a greater sensitivity at lower concentrations and a considerably longer lifetime. The results also demonstrated that the interaction of BSA with SA and HA was also highly temperature- and media-dependent. Under the most physiologically relevant conditions of MEM at 37 °C, BSA was more readily adsorbed to SA with significant differences between biomaterials, but no differences were observed during the desorption process. The use of this method to analyze adsorption under competitive conditions will be the subject of further investigations.


Assuntos
Equipamentos e Provisões , Corantes Fluorescentes/síntese química , Soroalbumina Bovina/análise , Adsorção , Animais , Bovinos , Físico-Química , Corantes Fluorescentes/química , Porosidade , Propriedades de Superfície
10.
J Mater Sci Mater Med ; 24(3): 597-610, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23242766

RESUMO

The bioactivity of calcium phosphate bone grafts of varying chemistry and strut-porosity was compared by determining the rate of formation of hydroxycarbonate apatite crystals on the material surface after being soaked in simulated body fluid for up to 30 days. Three groups of silicate-substituted hydroxyapatite material were tested, with each group comprising a different quantity of strut-porosity (23, 32, and 46 % volume). A commercially available porous ß-tricalcium phosphate bone graft substitute was tested for comparison. Results indicate that strut-porosity of a material affects the potential for formation of a precursor to bone-like apatite and further confirms previous findings that ß-tricalcium phosphate is less bioactive than hydroxyapatite.


Assuntos
Apatitas/química , Substitutos Ósseos , Fosfatos de Cálcio/química , Microscopia Eletrônica de Varredura , Difração de Raios X
11.
J Biomed Mater Res A ; 100(6): 1550-5, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22419568

RESUMO

The effect of increasing strut porosity on the osteoinductivity of porous calcium phosphate (CaP) and silicate-substituted calcium phosphate (SiCaP) bone substitute materials was investigated in an ovine ectopic model. One to two millimeter-sized granules or block implants with strut porosities of 10, 20, or 30% were inserted into the left and right paraspinalis muscle. At 12 weeks, histological sections were prepared through the center of each implant and bone contact, bone area and implant area quantified. Backscattered scanning electron microscopy (bSEM) was used to visualize bone within small pores in the struts of the scaffolds. Increased bone formation was measured in the SiCaP with 30% strut porosity (5.482% ± 1.546%) when compared with the nonsilicate CaP with the same morphology (1.160% ± 0.502%, p = 0.02), indicating that silicate substitution may increase osteoinduction. Greater bone formation was seen in scaffolds with increased strut porosity. No bone growth was found in any of the SiCaP scaffold with 10% porosity. There was no significant difference between block and granule specimens. Scanning electron microscopy and EDX in combination with histology demonstrated bone formation within pores <5 µm in size. The use of silicate-substituted CaP material with increased strut porosity may further augment repair and regeneration in bony sites.


Assuntos
Substitutos Ósseos/metabolismo , Fosfatos de Cálcio/metabolismo , Osteogênese , Animais , Substitutos Ósseos/química , Fosfatos de Cálcio/química , Porosidade , Ovinos , Silicatos/química , Silicatos/metabolismo , Alicerces Teciduais/química
12.
J Orthop Res ; 30(3): 356-63, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21901753

RESUMO

We hypothesized that the electrochemical deposition of hydroxyapatite (EHA) can be used to incorporate silver (Ag), providing a controlled and sustained release of Ag ions at a bactericidal concentration. Six groups were investigated: electrochemical co-precipitation of HA and Ag (EHA/Ag); EHA pre-coated discs treated in AgN0(3) (EHA/AgN0(3)); plasma sprayed HA (PHA) pre-coated discs treated in AgN0(3) (PHA/AgN0(3)); EHA with 2 "layers" of Ag (EHA/Ag/2 layers); EHA coating only; and PHA coating only. Scanning electron microscopy (SEM) and energy dispersive X-ray (EDX) and X-ray diffraction (XRD) analyses quantified coating thickness, calcium/phosphorous ratio, and % atomic silver content, respectively. Inductively coupled plasma-mass spectrometry quantified the amount of Ag released in phosphate-buffered saline, and zone of inhibition tests on agar plates using a lawn of Staph aureus were quantified in each group. XRD and EDX analysis confirmed the presence of Ag in all coatings. EHA coated discs with two layers of Ag and the EHA discs soaked in AgN0(3) showed significantly higher zones of inhibition at all time points when compared with all other groups (except PHA/AgN0(3) on day 0). This study demonstrated that Ag ions can be incorporated into a HA coating using an electrochemical technique.


Assuntos
Anti-Infecciosos Locais/administração & dosagem , Doenças Ósseas Infecciosas/prevenção & controle , Durapatita/química , Nitrato de Prata/administração & dosagem , Prata/administração & dosagem , Anti-Infecciosos Locais/química , Doenças Ósseas Infecciosas/etiologia , Fosfatos de Cálcio/análise , Técnicas Eletroquímicas , Prótese Articular/efeitos adversos , Espectrometria de Massas , Microscopia Eletrônica de Varredura , Prata/análise , Prata/química , Nitrato de Prata/química , Espectrometria por Raios X , Titânio , Difração de Raios X
13.
J Bone Joint Surg Am ; 93(23): 2219-26, 2011 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-22159858

RESUMO

BACKGROUND: The osteoinductivity of silicate-substituted calcium phosphate and stoichiometric calcium phosphate was investigated with use of ectopic implantation. Implants with a macroporosity of 80% and a strut porosity of 30% were inserted into sites located in the left and right paraspinal muscles of six female sheep. METHODS: After twelve weeks in vivo, a longitudinal thin section was prepared through the center of each implant. Bone formation within the implant, bone formation in contact with the implant surface, and implant resorption were quantified with use of a line intersection method. The specimens were also analyzed with use of backscattered scanning electron microscopy and energy-dispersive x-ray analysis. RESULTS: Silicate substitution had a significant effect on the formation of bone both within the implant and on the implant surface during the twelve-week period. Bone area within the implant was greater in the silicate-substituted calcium phosphate group (mean, 7.65% ± 3.2%) than in the stoichiometric calcium phosphate group (0.99% ± 0.9%, p = 0.01). The amount of bone formed at the surface of the implant was also significantly greater in the silicate-substituted calcium phosphate group (mean, 26.00% ± 7.8%) than in the stoichiometric calcium phosphate group (2.2% ± 2.0%, p = 0.01). Scanning electron microscopy demonstrated bone formation within pores that were <5 µm in size, and energy-dispersive x-ray analysis confirmed the presence of silicon within the new bone in the silicate-substituted calcium phosphate group. CONCLUSIONS: The formation of bone within muscle during the twelve-week period showed both silicate-substituted calcium phosphate and stoichiometric calcium phosphate to be osteoinductive in an ovine model. Silicate substitution significantly increased the amount of bone that formed and the amount of bone attached to the implant surface. New bone formation occurred through an intramembranous process within the implant structure.


Assuntos
Fosfatos de Cálcio/farmacologia , Osteogênese/efeitos dos fármacos , Próteses e Implantes , Silicatos/farmacologia , Animais , Osso e Ossos/ultraestrutura , Feminino , Microscopia Eletrônica de Varredura , Porosidade , Ovinos
14.
J Mater Sci Mater Med ; 22(10): 2155-64, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21858741

RESUMO

It has been proposed that one of the underlying mechanisms contributing to the bioactivity of osteoinductive or osteoconductive calcium phosphates involves the rapid dissolution and net release of calcium and phosphate ions from the matrix as alternatively a precursor to subsequent re-precipitation of a bone-like apatite at the surface and/or to facilitate ion exchange in biochemical processes. In order to confirm and evaluate ion release from sintered hydroxyapatite (HA) and to examine the effect of silicate substitution into the HA lattice on ion exchange under physiological conditions we monitored Ca(2+), PO(4)(3-) and SiO(4)(4-) levels in Earl's minimum essential medium (E-MEM) in the absence (serum-free medium, SFM) or presence (complete medium, C-MEM) of foetal calf serum (FCM), with both microporous HA or 2.6 wt% silicate-substituted HA (SA) sintered discs under both static and semi-dynamic (SD) conditions for up to 28 days. In SFM, variation in Ca(2+) ion concentration was not observed with either disc chemistry or culture conditions. In C-MEM, Ca(2+) ions were released from SA under static and SD conditions whereas with HA Ca(2+) was depleted under SD conditions. PO(4)(3-) depletion occurred in all cases, although it was greater in C-MEM, particularly under SD conditions. SiO(4)(4-) release occurred from SA irrespective of medium or culture conditions but a sustained release only occurred in C-MEM under SD conditions. In conclusion we showed that under physiological conditions the reservoir of exchangeable ions in both HA and SA in the absence of serum proteins is limited, but that the presence of serum proteins facilitated greater ionic exchange, particularly with SA. These observations support the hypothesis that silicate substitution into the HA lattice facilitates a number of ionic interactions between the material and the surrounding physiological environment, including but not limited to silicate ion release, which may play a key role in determining the overall bioactivity and osteoconductivity of the material. However, significant net release of Ca(2+) and PO(4)(3-) was not observed, thus rapid or significant net dissolution of the material is not necessarily a prerequisite for bioactivity in these materials.


Assuntos
Proteínas Sanguíneas/química , Meios de Cultura/química , Durapatita/química , Silicatos/química , Materiais Biocompatíveis/química , Cálcio/química , Concentração de Íons de Hidrogênio , Troca Iônica , Fosfatos/química
15.
Spine J ; 7(4): 475-90, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17630146

RESUMO

BACKGROUND CONTEXT: A number of different synthetic calcium-based bone graft substitutes (BGS) are currently available for clinical use. There is, however, a lack of comparative performance data regarding the relative efficacy of these materials when placed in an osseous defect site. PURPOSE: To compare the rate, quality, and extent of osseous healing in a standard rabbit defect model for three commercially available BGS materials by measuring early bone formation and completion of defect healing and to identify whether rapid scaffold resorption stimulated or impaired bone healing. STUDY DESIGN: Osteochondral defects, 4.8 mm in diameter and 6 to 7 mm deep, were made through the articular surface into the subchondral bone of the femoral condyle of New Zealand White rabbits and filled with cylindrical pellets of one of three commercially available BGS materials: dense calcium sulfate (DCaS), ultraporous tricalcium phosphate (beta-TCP), and porous silicated calcium phosphate (Si-CaP). The repair response was examined at 1, 3, 6, and 12 weeks after surgery (n=4 per BGS per time point). METHOD: Qualitative histological and quantitative histomorphometric (% new bone, % bone graft substitute, capillary index, and mineral apposition rates) analysis. RESULTS: Rapid resorption of D-CaS, primarily through dissolution, elicited a mild inflammatory response that left the defect site empty before significant quantities of new bone were formed. Both beta-TCP and Si-CaP scaffolds supported early bone apposition (<1 week). However, beta-TCP degradation products subsequently provoked an inflammatory response that impaired and reversed bone apposition within the defect site. The Si-CaP scaffolds appeared to be more stable and supported further bone apposition, with the development of an adaptive bone-scaffold composite; cell-mediated resorption of scaffold and new bone were observed in response to local load and contributed to the production of a functional repair within the defect site. CONCLUSIONS: Rapid BGS resorption impaired the regenerative ability of local bone via three pathways: 1) insufficient persistence of an osteoconductive scaffold to encourage bone apposition, 2) destabilization of early bony apposition through scaffold disintegration, and 3) stimulation of an inflammatory response by elevated levels of particulate degradation products. This had a significant impact on the ultimate rate of healing. D-CaS did not stimulate early bone apposition, but bone repair was more advanced in D-CaS-treated defects at 12 weeks as compared with those treated with beta-TCP, despite the beta-TCP supporting direct bone apposition at 1 week. Si-CaP appeared to provide a more stable osteoconductive scaffold, which supported faster angiogenesis and bone apposition throughout the defect site, with the development of a functionally adaptive trabecular structure through resorption/remodelling of both scaffold and new bone. There was rapid formation of mineralized tissue at week 1 within the center of the defect and complete infiltration with dense, predominantly mature bone by weeks 3 to 6. The progressive remodeling of bone ingrowth and scaffold to reflect the distribution of local host tissue, combined with histological evidence of targeted osteoclastic resorption of both scaffold and bone, suggest that bone adaptation within the scaffold could be in response to Wolff's law. Although this model may not directly translate to a spinal fusion model and the products may vary according to the environment, these results suggest that, in patients in whom bone regeneration may be compromised, the degradation observed with some resorbable bone grafts may contribute to the decoupling of bone regeneration and resorbtion within the graft site, which may ultimately lead to incomplete bone repair.


Assuntos
Doenças Ósseas/cirurgia , Substitutos Ósseos , Fosfatos de Cálcio , Sulfato de Cálcio , Cerâmica , Absorção , Animais , Materiais Biocompatíveis , Doenças Ósseas/fisiopatologia , Substitutos Ósseos/normas , Osso e Ossos/irrigação sanguínea , Calcificação Fisiológica , Fosfatos de Cálcio/efeitos adversos , Fosfatos de Cálcio/metabolismo , Sulfato de Cálcio/efeitos adversos , Sulfato de Cálcio/farmacocinética , Neovascularização Fisiológica , Porosidade , Coelhos , Silicatos , Fatores de Tempo , Cicatrização
16.
Biomaterials ; 27(29): 5014-26, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16790272

RESUMO

The osseous response to silicon (Si) level (0, 0.2, 0.4, 0.8 and 1.5 wt% Si) within 5 batches of matched porosity silicate-substituted hydroxyapatite (SA) scaffold was assessed by implantation of 4.6 mm diameter cylinders in the femoral intercondylar notch of New Zealand White rabbits for periods of 1, 3, 6 and 12 weeks. Histological evaluation and histomorphometric quantification of bone ingrowth and mineral apposition rate (MAR) demonstrated the benefits to early (<1 week) bone ingrowth and repair through incorporation of Si, at all levels, in porous hydroxyapatite (HA) lattices as compared to stoichiometric (0 wt% Si) HA. The group containing 0.8 wt% Si supported significantly more bone ingrowth than all other groups at 3 and 6 weeks (P<0.05), initially through its elevated MAR between weeks 1 and 2, which was significantly higher than that of all other Si-containing groups (P<0.05). The level of silicate substitution also influenced the morphology and stability of the repair, with elevated levels of bone resorption and apposition apparent within other Si-containing groups at timepoints >3 weeks as compared to the 0 and 0.8 wt% Si groups. At 12 weeks, the net amount of bone ingrowth continued to rise in the 0, 0.8 and 1.5 wt% groups, apparently as a result of adaptive remodelling throughout the scaffold. Ingrowth levels remained highest in the 0.8 wt% Si group, was characterised by a dense trabecular morphology in the superficial region graduating to a more open network in the deep zone. These results highlight the sensitivity of healing response to Si level and suggest that an optimal response is obtained when SA is substituted with 0.8 wt% Si through its effect on the activity of both bone forming and bone resorbing cells.


Assuntos
Regeneração Óssea/fisiologia , Substitutos Ósseos , Durapatita , Silicatos , Silício , Animais , Feminino , Coelhos
17.
Philos Trans A Math Phys Eng Sci ; 362(1825): 2821-50, 2004 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-15539372

RESUMO

Increases in reconstructive orthopaedic surgery, such as total hip replacement and spinal fusion, resulting from advances in surgical practice and the ageing population, have lead to a demand for bone graft that far exceeds supply. Consequently, a number of synthetic bone-graft substitutes (BGSs) have been developed with mixed success and surgical acceptance. Skeletal tissue regeneration requires the interaction of three basic elements: cells, growth factors (GFs) and a permissive scaffold. This can be achieved by pre-loading a synthetic scaffold with GFs or pre-expanded cells; however, a 'simpler' approach is to design intrinsic 'osteoinductivity' into your BGS, i.e. the capability to recruit and stimulate the patient's own GFs and stem cells. Through investigation of the mechanisms controlling bone repair in BGSs, linking interactions between the local chemical and physical environment, scientists are currently developing osteoinductive materials that can stimulate bone regeneration through control of the scaffold chemistry and structure. Moreover, this body of research is providing the foundations for future generations of BGSs and bone-repair therapies and may ultimately contribute towards improving the quality of life through maintenance of the skeleton and reversal of disease states, as opposed to the mending of broken bones that we currently practice. Will we be able to grow our own bones in a bioreactor for use as autologous graft materials in the future? Could surgery be limited to accidental trauma cases, with greater restoration of function through biochemical or gene therapies? The technology and research probes necessary to this task are currently being developed with the advent of nanotechnology, genomics and proteomics: are we about to embark on a chemical revolution in medicine? This paper aims to discuss some of the current thinking on the mechanisms behind bioactivity and biocompatibility in bone and how a fuller understanding of the interactions between cells and the materials used today could bring about completely new approaches for the treatment of bone fracture and disease tomorrow.


Assuntos
Materiais Biocompatíveis/uso terapêutico , Regeneração Óssea/fisiologia , Substitutos Ósseos/uso terapêutico , Transplante Ósseo/métodos , Transplante Ósseo/tendências , Engenharia Tecidual/métodos , Engenharia Tecidual/tendências , Animais , Doenças Ósseas/cirurgia , Técnicas de Cultura de Células/métodos , Técnicas de Cultura de Células/tendências , Previsões , Humanos
18.
J Biomed Mater Res A ; 68(1): 187-200, 2004 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-14661264

RESUMO

Previous investigations have shown that both the early biological response and the mechanical properties of a porous hydroxyapatite bone graft substitute are highly sensitive to its pore structure. The objective of this study was to evaluate whether the pore structure continued to influence bone integration in the medium to long term. Two screened batches of porous hydroxyapatite (PHA) designated as batch A and batch B, with porosities of approximately 60 and 80%, respectively, were selected for this study and implanted for periods of 5, 13, and 26 weeks into the lower femur of New Zealand White rabbits. Histomorphometric analysis of the absolute volume of bone ingrowth within batch A and B implants from 5 to 26 weeks showed that the absolute volume of bone ingrowth was consistently lower in batch A (10-21%), compared to batch B implants (24-31%). However, when the volume of bone ingrowth was normalised for the available pore space, this difference was reduced (23-47% and 32-42% for batches A and B, respectively). These observations suggest that differences in the volume of bone ingrowth initially depended on pore interconnectivity rather than pore size, whereas the volume or morphology of the PHA influenced the volume and morphology of bone ingrowth at later time points. Compression testing showed that bone ingrowth had a strong reinforcing effect on PHA bone graft substitutes, and a strong correlation was identified between mechanical properties and the absolute volume of ingrowth for both batches A and B. Furthermore, at 13 and 26 weeks, there was no significant variation in the ultimate compressive strength of integrated batch A and B implants. This similarity in ultimate mechanical properties indicated that the absolute volume of ingrowth may be mediated by the PHA structure through its impact on the dynamics of the local biomechanical environment. The results of push-out testing showed that fixation of PHA bone graft substitutes was independent of density within the range studied, with no significant difference in the interfacial shear stress between batches A and B at each time point throughout the study.


Assuntos
Substitutos Ósseos , Durapatita , Animais , Substitutos Ósseos/química , Transplante Ósseo , Osso e Ossos/ultraestrutura , Fêmur , Osteogênese , Coelhos , Estresse Mecânico , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...