Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Med Phys ; 23(6): 871-6, 1996 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-8798172

RESUMO

We have developed a method for correcting for the scatter produced by the computed radiography plates in single-shot dual-energy imaging. In our technique, which uses a series of four computed radiography plates (the middle two plates act as a filter), the back plate can have scatter fractions as high as 30% due to the scatter from the first three plates. We use the deconvolution method to correct for this scatter, as the scatter medium is uniform and isotropic with a constant air gap. The ratio of the modulation transfer function (MTF) of a standard computed radiography plate to that of a dual-energy plate gives us the correction factor we need to scale the Fourier transforms of our images, thus compensating for the reduced response of the system due to scatter. We also investigated the effect of having an air gap between the back dual-energy plate and the first three plates. Our measurements show that this degrades the signal-to-noise response of the back plate slightly at low spatial frequencies. We also used independent scatter fraction measurements to verify the validity of our MTF measurements. Applying the correction to a back plate image improves the fine detail contrast by approximately 30%.


Assuntos
Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Ar , Fenômenos Biofísicos , Biofísica , Humanos , Modelos Teóricos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/instrumentação , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/estatística & dados numéricos , Espalhamento de Radiação
2.
Med Phys ; 22(10): 1581-93, 1995 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-8551982

RESUMO

Measurements were made of the MTF(f), NPS(f), and DQE(f) of four generations of computed radiography (CR) imaging plates and three generations of CR image readers. The MTF generally showed only a minor change between generations of plates and readers, but the DQE(f) has improved substantially from a very early plate/reader combination to a more recent one. The DQE in the more recent plate/reader combination is 1.3X greater at low frequencies and about 3X greater at high frequencies than the much earlier versions. Thus there has been substantial improvement in the imaging performance obtainable with CR since some of the early observer studies which indicated poorer performance with CR than with screen-film.


Assuntos
Interpretação de Imagem Radiográfica Assistida por Computador/instrumentação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Humanos , Matemática , Radiografia Torácica , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...