Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Ultrasound Q ; 37(3): 272-277, 2021 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-34478427

RESUMO

ABSTRACT: To determine if lung to liver MR T2 signal ratio is predictive of neonatal outcome in fetuses with congenital diaphragmatic hernia (CDH).After Interal Review Board approval, the PACS systems at the University of Washington and University of Utah were searched for cases having an in utero fetal MR examination diagnostic of CDH. Inclusion criteria were at least 1 prior ultrasound demonstrating a CDH and an MR obtained within 1 week of that prior ultrasound.A total of 69 patients from the University of Utah and 13 from the University of Washington satisfied the inclusion criteria for a total of 82. After adjusting for gestational age and contralateral lung volume, there was little apparent association between contralateral lung to liver MR T2 signal and 5-minute Apgar score and neonatal mortality When considering neonatal Apgar and mortality, increasing contralateral lung volume was significantly associated with lower risk (hazard ratio, 0.40 per doubling; 95% confidence interval, 0.24-0.69; P = 0.001) as expected.Our data demonstrate that the lung to liver MR signal ratio was not predictive of outcome. The measurement of contralateral lung area, and gestational age at the time of the examination (time of diagnosis) are still the best predictors of poor neonatal outcome.


Assuntos
Hérnias Diafragmáticas Congênitas , Feminino , Feto , Idade Gestacional , Hérnias Diafragmáticas Congênitas/diagnóstico por imagem , Humanos , Recém-Nascido , Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Gravidez , Ultrassonografia Pré-Natal
2.
J Burn Care Res ; 42(6): 1227-1231, 2021 11 24.
Artigo em Inglês | MEDLINE | ID: mdl-34105730

RESUMO

Stevens-Johnson syndrome (SJS) and toxic epidermal necrolysis (TEN) are acute, life-threatening diseases that cause sloughing of the skin and mucous membranes. Despite improved survival rates, few studies focus on long-term outcomes. We conducted a single-center review of all patients with SJS/TEN admitted from January 2008 to 2014. SJS/TEN survivors were invited to participate in the validated Veterans RAND 12-Item Health Survey (VR-12) to assess health-related quality of life using a mental health composite score and physical health component score (PCS). The sample was compared to U.S. norms using one-sample two-tailed t tests. A second questionnaire addressed potential long-term medical complications related to SJS/TEN. Of 81 treated subjects, 24 (30%) long-term survivors responded. Participants identified cutaneous sequelae most frequently (79%), followed by nail problems (70%), oral (62%), and ocular (58%) sequalae. Thirty-eight percent rated their quality of life to be "unchanged" to "much better" since their episode of SJS/TEN. The average PCS was lower than U.S. population norms (mean: 36 vs 50, P = .006), indicating persistent physical sequelae from SJS/TEN. These results suggest that SJS/TEN survivors continue to suffer from long-term complications that impair their quality of life and warrant ongoing follow-up by a multidisciplinary care team.


Assuntos
Queimaduras/psicologia , Nível de Saúde , Qualidade de Vida/psicologia , Índice de Gravidade de Doença , Síndrome de Stevens-Johnson/psicologia , Sobreviventes/psicologia , Adulto , Atitude Frente a Saúde , Queimaduras/reabilitação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Exame Físico/métodos , Estudos Retrospectivos , Síndrome de Stevens-Johnson/reabilitação
3.
Ultrasound Q ; 35(1): 30-34, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30724866

RESUMO

OBJECTIVES: The objective of this study is to establish a nomogram of fetal abdominal wall fat thickness in fetuses with known normal neonatal outcomes. METHODS: After IRB approval (HSD-49496), 157 ultrasound examinations in 100 patients, 41 of whom had multiple examinations during the same pregnancy were reviewed. The thickness of the fetal lateral abdominal wall fat Interreader agreement was summarized using the intraclass correlation coefficient (ICC). Fat thickness growth curve equations were estimated to quantify the relationship between fat thickness and gestational age. RESULTS: The abdominal wall fat had an intraclass correlation coefficient of 0.93 (95% confidence interval, 0.90-0.96) for 2 readers. Fat thickness increased in all 41 fetuses with multiple examinations (P < 0.001). Fat thickness increased 0.19 mm per week on average (95% confidence interval, 0.17-0.21 mm; P < 0.001) from an average of 1.7 mm at 22 weeks and 4.3 mm at 36 weeks. CONCLUSIONS: Lateral wall abdominal fat can be reproducibly measured with good inter observer correlation, and fat does increase with increasing gestational age in normal fetuses. We believe the utility of fetal fat is the documentation of its presence as a reassuring finding indicative of normal fetal health, particularly when prior dating is discrepant or not available during the third trimester.


Assuntos
Gordura Abdominal/diagnóstico por imagem , Parede Abdominal/diagnóstico por imagem , Nomogramas , Ultrassonografia Pré-Natal/métodos , Ultrassonografia Pré-Natal/estatística & dados numéricos , Gordura Abdominal/embriologia , Músculos Abdominais/diagnóstico por imagem , Músculos Abdominais/embriologia , Parede Abdominal/embriologia , Adulto , Feminino , Humanos , Gravidez , Terceiro Trimestre da Gravidez
4.
J Comput Assist Tomogr ; 40(5): 746-51, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27560011

RESUMO

OBJECTIVE: It is known that atelectasis demonstrates greater contrast enhancement than pneumonia on computed tomography (CT). However, the effectiveness of using a Hounsfield unit (HU) threshold to distinguish pneumonia from atelectasis has never been shown. The objective of the study is to demonstrate that an HU threshold can be quantitatively used to effectively distinguish pneumonia from atelectasis. METHODS: Retrospectively identified CT pulmonary angiogram examinations that did not show pulmonary embolism but contained nonaerated lungs were classified as atelectasis or pneumonia based on established clinical criteria. The HU attenuation was measured in these nonaerated lungs. Receiver operating characteristic (ROC) analysis was performed to determine the area under the ROC curve, sensitivity, and specificity of using the attenuation to distinguish pneumonia from atelectasis. RESULTS: Sixty-eight nonaerated lungs were measured in 55 patients. The mean (SD) enhancement was 62 (18) HU in pneumonia and 119 (24) HU in atelectasis (P < 0.001). A threshold of 92 HU diagnosed pneumonia with 97% sensitivity (confidence interval [CI], 80%-99%) and 85% specificity (CI, 70-93). Accuracy, measured as area under the ROC curve, was 0.97 (CI, 0.89-0.99). CONCLUSIONS: We have established that a threshold HU value can be used to confidently distinguish pneumonia from atelectasis with our standard CT pulmonary angiogram imaging protocol and patient population. This suggests that a similar threshold HU value may be determined for other scanning protocols, and application of this threshold may facilitate a more confident diagnosis of pneumonia and thus speed treatment.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Pulmão/diagnóstico por imagem , Reconhecimento Automatizado de Padrão/métodos , Pneumonia/diagnóstico por imagem , Atelectasia Pulmonar/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
5.
Abdom Imaging ; 39(5): 1127-33, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25237003

RESUMO

PURPOSE: To determine the most common errors of epinephrine administration during severe allergic-like contrast reaction management using high-fidelity simulation surrogates. MATERIALS AND METHODS: IRB approval and informed consent were obtained for this HIPAA-compliant bi-institutional prospective study of 40 radiology residents, fellows, and faculty who were asked to manage a structured high-fidelity severe allergic-like contrast reaction scenario (i.e., mild hives progressing to mild bronchospasm, then bronchospasm unresponsive to bronchodilators, and finally anaphylactic shock) on an interactive manikin. Intravenous (IV) and intramuscular epinephrine ampules were available to all participants, and the manikin had a functioning intravenous catheter for all scenarios. Video recordings of their performance were reviewed by experts in contrast reaction management, and errors in epinephrine administration were recorded and characterized. RESULTS: No participant (0/40) failed to give indicated epinephrine, but more than half (58% [23/40]) committed an error while doing so. The most common mistake was to administer epinephrine as the first-line treatment for mild bronchospasm (33% [13/40]). Other common errors were to administer IV epinephrine without a subsequent IV saline flush or concomitant IV fluids (25% [10/40]), administer an overdose of epinephrine (8% [3/40]), and administer epinephrine 1:1000 intravenously (8% [3/40]). CONCLUSION: Epinephrine administration errors are common. Many radiologists fail to administer albuterol as the first-line treatment for mild bronchospasm and fail to flush the IV catheter when administering IV epinephrine. High-fidelity contrast reaction scenarios can be used to identify areas for training improvement.


Assuntos
Meios de Contraste/efeitos adversos , Epinefrina/uso terapêutico , Hipersensibilidade Imediata/tratamento farmacológico , Manequins , Erros de Medicação/estatística & dados numéricos , Radiologia/educação , Administração Intravenosa , Agonistas alfa-Adrenérgicos/uso terapêutico , Epinefrina/administração & dosagem , Humanos , Hipersensibilidade Imediata/induzido quimicamente , Estudos Prospectivos
6.
Eur J Radiol ; 82(12): 2247-52, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24041436

RESUMO

PURPOSE: We developed a computer-based interactive simulation program for teaching contrast reaction management to radiology trainees and compared its effectiveness to high-fidelity hands-on simulation training. MATERIALS AND METHODS: IRB approved HIPAA compliant prospective study of 44 radiology residents, fellows and faculty who were randomized into either the high-fidelity hands-on simulation group or computer-based simulation group. All participants took separate written tests prior to and immediately after their intervention. Four months later participants took a delayed written test and a hands-on high-fidelity severe contrast reaction scenario performance test graded on predefined critical actions. RESULTS: There was no statistically significant difference between the computer and hands-on groups' written pretest, immediate post-test, or delayed post-test scores (p>0.6 for all). Both groups' scores improved immediately following the intervention (p<0.001). The delayed test scores 4 months later were still significantly higher than the pre-test scores (p ≤ 0.02). The computer group's performance was similar to the hands-on group on the severe contrast reaction simulation scenario test (p = 0.7). There were also no significant differences between the computer and hands-on groups in performance on the individual core competencies of contrast reaction management during the contrast reaction scenario. CONCLUSION: It is feasible to develop a computer-based interactive simulation program to teach contrast reaction management. Trainees that underwent computer-based simulation training scored similarly on written tests and on a hands-on high-fidelity severe contrast reaction scenario performance test as those trained with hands-on high-fidelity simulation.


Assuntos
Instrução por Computador/estatística & dados numéricos , Meios de Contraste/efeitos adversos , Currículo , Hipersensibilidade a Drogas/etiologia , Hipersensibilidade a Drogas/prevenção & controle , Radiologia/educação , Interface Usuário-Computador , Adulto , Hipersensibilidade a Drogas/diagnóstico , Avaliação Educacional/estatística & dados numéricos , Feminino , Humanos , Internato e Residência/organização & administração , Masculino , Washington , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...