Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Cureus ; 14(5): e25102, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35733454

RESUMO

Atrial fibrillation (AF), the most prevalent cardiac arrhythmia encountered in clinical practice, is linked with substantial morbidity and mortality due to accompanying risk of stroke and thromboembolism. Patients with AF are at a five-fold higher risk of suffering from a stroke. Anticoagulation therapy, with either vitamin K antagonists or novel oral anticoagulants (NOACs), is a standard approach to reduce the risk. Consultant physicians (CPs) in India are the primary point of contact for the majority of patients before they approach a specialist. The CPs may face challenges in screening and diagnosing AF patients. The apprehensions associated with managing AF patients with anticoagulants, further add to the challenges of a CP. This review aimed to identify the key decision points for the CPs to diagnose AF and initiate anticoagulation in patients with non-valvular AF (NVAF) and bring to the table a simplified recommendation supported by expert opinion and guidelines for stroke prevention in NVAF patients.

2.
JACC Cardiovasc Interv ; 15(1): 93-104, 2022 01 10.
Artigo em Inglês | MEDLINE | ID: mdl-34991828

RESUMO

OBJECTIVES: This study sought to evaluate the 30-day and 1-year safety and performance of the Hydra transcatheter aortic valve (THV) (in the treatment of symptomatic severe aortic stenosis in patients at high or extreme surgical risk. BACKGROUND: The Hydra THV is a novel repositionable self-expanding system with supra-annular bovine pericardial leaflets. METHODS: The Hydra CE study was a premarket, prospective, multicenter, single-arm study conducted across 18 study centers in Europe and Asia-Pacific countries. The primary endpoint was all-cause mortality at 30 days. All endpoints were adjudicated by an independent clinical events committee. RESULTS: A total of 157 patients (79.2 ± 7.1 years of age, 58.6% female; Society of Thoracic Surgeons score 4.7 ± 3.4%) were enrolled. Successful implantation was achieved in 94.3% cases. At 30 days, there were 11 (7.0%) deaths, including 9 (5.7%) cardiovascular deaths, of which 5 (3.2%) were device related. At 1 year, there were 23 (14.6%) deaths, including 13 (8.3%) cardiovascular deaths. At 30 days, there were significant improvement of effective orifice area (from 0.7 ± 0.2 cm2 to 1.9 ± 0.6 cm2) and mean aortic valve gradient (from 49.5 ± 18.5 mm Hg to 8.1 ± 3.7 mm Hg), which were sustained up to 1 year. Moderate or severe paravalvular leak was observed in 6.3% of patients at 30 days and 6.9% of patients at 1 year. The rate of new permanent pacemaker implantation was 11.7% at 30 days and 12.4% at 1 year. CONCLUSIONS: The Hydra CE study demonstrated that transcatheter aortic valve replacement with Hydra THV offered favorable efficacy at 1 year, providing large effective orifice area and low transvalvular gradient as well as acceptable complication rates with regard to new permanent pacemaker and paravalvular leak. (A Clinical Evaluation of the HYDRA Self Expanding Transcatheter Aortic Valve; NCT02434263).


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Animais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Bovinos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA