Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Environ Health Prev Med ; 23(1): 53, 2018 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-30360764

RESUMO

BACKGROUND: Airborne particulate pollution is more critical in the developing world than in the developed countries in which industrialization and urbanization are rapidly increased. Yangon, a second capital of Myanmar, is a highly congested and densely populated city. Yet, there is limited study which assesses particulate matter (PM2.5) in Yangon currently. Few previous local studies were performed to assess particulate air pollution but most results were concerned PM10 alone using fixed monitoring. Therefore, the present study aimed to assess distribution of PM2.5 in different townships of Yangon, Myanmar. This is the first study to quantify the regional distribution of PM2.5 in Yangon City. METHODS: The concentration of PM2.5 was measured using Pocket PM2.5 Sensor (Yaguchi Electric Co., Ltd., Miyagi, Japan) three times (7:00 h, 13:00 h, 19:00 h) for 15 min per day for 5 days from January 25th to 29th in seven townships. Detailed information of eight tracks for PM2.5 pollution status in different areas with different conditions within Kamayut Township were also collected. RESULTS: The results showed that in all townships, the highest PM2.5 concentrations in the morning followed by the evening and the lowest concentrations in the afternoon were observed. Among the seven townships, Hlaingtharyar Township had the highest concentrations (164 ± 52 µg/m3) in the morning and (100 ± 35 µg/m3) in the evening. Data from eight tracks in Kamayut Township also indicated that PM2.5 concentrations varied between different areas and conditions of the same township at the same time. CONCLUSION: Myanmar is one of the few countries that still have to establish national air quality standards. The results obtained from this study are useful for the better understanding of the nature of air pollution linked to PM2.5. Moreover, the sensor which was used in this study can provide real-time exposure, and this could give more accurate exposure data of the population especially those subpopulations that are highly exposed than fixed station monitoring.


Assuntos
Poluentes Atmosféricos/análise , Monitoramento Ambiental , Material Particulado/análise , Cidades , Mianmar
2.
Phys Med Biol ; 62(2): 501-516, 2017 01 21.
Artigo em Inglês | MEDLINE | ID: mdl-28000617

RESUMO

Macrophages are excellent imaging targets for detecting atherosclerotic plaques as they are involved in all the developmental stages of atherosclerosis. However, no imaging technique is currently capable of visualizing macrophages inside blood vessel walls. The current study develops an intravascular ultrasonic-photoacoustic (IVUP) imaging system combined with indocyanine green (ICG) as a contrast agent to provide morphological and compositional information about the targeted samples. Both tissue-mimicking vessel phantoms and atherosclerotic plaque-mimicking porcine arterial tissues are used to demonstrate the feasibility of mapping macrophages labeled with ICG by endoscopically applying the proposed hybrid technique. A delay pulse triggering technique is able to sequentially acquire photoacoustic (PA) and ultrasound (US) signals from a single scan without using any external devices. The acquired PA and US signals are used to reconstruct 2D cross-sectional and 3D volumetric images of the entire tissue with the ICG-loaded macrophages injected. Due to high imaging contrast and sensitivity, the IVUP imaging vividly reveals structural information and detects the spatial distribution of the ICG-labeled macrophages inside the samples. ICG-assisted IVUP imaging can be a feasible imaging modality for the endoscopic detection of atherosclerotic plaques.


Assuntos
Vasos Sanguíneos/diagnóstico por imagem , Macrófagos/patologia , Microscopia Acústica/instrumentação , Imagens de Fantasmas , Placa Aterosclerótica/diagnóstico , Ultrassonografia/instrumentação , Angiografia , Animais , Vasos Sanguíneos/patologia , Estudos Transversais , Humanos , Imageamento Tridimensional , Verde de Indocianina , Microscopia Acústica/métodos , Imagem Multimodal/métodos , Placa Aterosclerótica/diagnóstico por imagem , Suínos , Ultrassonografia/métodos
3.
Biomed Opt Express ; 7(5): 1932-47, 2016 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-27231632

RESUMO

To minimize thermal injury, the current study evaluated the real-time temperature monitoring with a proportional-integrative-derivative (PID) controller during 980-nm photothermal treatment with a radially-diffusing applicator. Both simulations and experiments demonstrated comparable thermal behaviors in temperature distribution and the degree of irreversible tissue denaturation. The PID-controlled application constantly maintained the pre-determined temperature of 353 K (steady-state error = < 1 K). Due to constant energy delivery, coagulation volumes linearly increased up to 1.04 ± 0.02 cm(3) with irradiation time. Integration of temperature feedback with diffuser-assisted photothermal treatments can provide a feasible therapeutic modality to treat pancreatic tumors in an effective manner.

4.
Comput Med Imaging Graph ; 45: 57-62, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26258625

RESUMO

Intravascular ultrasound (IVUS) imaging is extremely important for detection and characterization of high-risk atherosclerotic plaques as well as gastrointestinal diseases. Recently, intravascular photoacoustic (IVPA) imaging has been used to differentiate the composition of biological tissues with high optical contrast and ultrasonic resolution. The combination of these imaging techniques could provide morphological information and molecular screening to characterize abnormal tissues, which would help physicians to ensure vital therapeutic value and prognostic significance for patients before commencing therapy. In this study, integration of a high-frequency IVUS imaging catheter (45MHz, single-element, unfocused, 0.7mm in diameter) with a multi-mode optical fiber (0.6mm in core diameter, 0.22 NA), an integrated intravascular ultrasonic-photoacoustic (IVUP) imaging catheter, was developed to provide spatial and functional information on light distribution in a turbid sample. Simultaneously, IVUS imaging was co-registered to IVPA imaging to construct 3D volumetric sample images. In a phantom study, a polyvinyl alcohol (PVA) tissue-mimicking arterial vessel phantom with indocyanine green (ICG) and methylene blue (MB) inclusion was used to demonstrate the feasibility of mapping the biological dyes, which are used in cardiovascular and cancer diagnostics. For the ex vivo study, an excised sample of pig intestine with ICG was utilized to target the biomarkers present in the gastrointestinal tumors or the atherosclerotic plaques with the proposed hybrid technique. The results indicated that IVUP endoscope with the 2.2-mm diameter catheter could be a useful tool for medical imaging.


Assuntos
Catéteres , Técnicas de Imagem por Elasticidade/instrumentação , Endossonografia/instrumentação , Imageamento Tridimensional/instrumentação , Técnica de Subtração/instrumentação , Ultrassonografia de Intervenção/instrumentação , Animais , Desenho de Equipamento , Análise de Falha de Equipamento , Miniaturização , Imagem Multimodal/instrumentação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...