Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
J Bone Joint Surg Br ; 92(4): 500-7, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20357325

RESUMO

Components from 73 failed knee replacements (TKRs) consisting of rotating-platform, mobile-bearing and fixed-bearing implants were examined to assess the patterns of wear. The patterns were divided into low-grade (burnishing, abrasion and cold flow) and high-grade (scratching, pitting/metal embedding and delamination) to assess the severity of the wear of polyethylene. The rotating-platform group had a higher incidence of low-grade wear on the upper surface compared with the fixed-bearing group. By contrast, high-grade wear comprising scratching, pitting and third-body embedding was seen on the lower surface. Linear regression analysis showed a significant correlation of the wear scores between the upper and lower surfaces of the tibial insert (R(2) = 0.29, p = 0.04) for the rotating-platform group, but no significant correlation was found for the fixed-bearing counterpart. This suggests that high-grade wear patterns on the upper surface are reduced with the rotating-platform design. However, the incidence of burnishing, pitting/third-body embedding and scratching wear patterns on the lower surface was higher compared with that in the fixed-bearing knee.


Assuntos
Prótese do Joelho , Falha de Prótese , Tíbia/cirurgia , Artroplastia do Joelho/instrumentação , Artroplastia do Joelho/métodos , Análise de Falha de Equipamento/métodos , Feminino , Humanos , Masculino , Desenho de Prótese , Reoperação , Estresse Mecânico
3.
J Bone Joint Surg Br ; 89(3): 408-12, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17356162

RESUMO

One of the most controversial issues in total knee replacement is whether or not to resurface the patella. In order to determine the effects of different designs of femoral component on the conformity of the patellofemoral joint, five different knee prostheses were investigated. These were Low Contact Stress, the Miller-Galante II, the NexGen, the Porous-Coated Anatomic, and the Total Condylar prostheses. Three-dimensional models of the prostheses and a native patella were developed and assessed by computer. The conformity of the curvature of the five different prosthetic femoral components to their corresponding patellar implants and to the native patella at different angles of flexion was assessed by measuring the angles of intersection of tangential lines. The Total Condylar prosthesis had the lowest conformity with the native patella (mean 8.58 degrees ; 0.14 degrees to 29.9 degrees ) and with its own patellar component (mean 11.36 degrees ; 0.55 degrees to 39.19 degrees ). In the other four prostheses, the conformity was better (mean 2.25 degrees ; 0.02 degrees to 10.52 degrees ) when articulated with the corresponding patellar component. The Porous-Coated Anatomic femoral component showed better conformity (mean 6.51 degrees ; 0.07 degrees to 9.89 degrees ) than the Miller-Galante II prosthesis (mean 11.20 degrees ; 5.80 degrees to 16.72 degrees ) when tested with the native patella. Although the Nexgen prosthesis had less conformity with the native patella at a low angle of flexion, this improved at mid (mean 3.57 degrees ; 1.40 degrees to 4.56 degrees ) or high angles of flexion (mean 4.54 degrees ; 0.91 degrees to 9.39 degrees ), respectively. The Low Contact Stress femoral component had the best conformity with the native patella (mean 2.39 degrees ; 0.04 degrees to 4.56 degrees ). There was no significant difference (p > 0.208) between the conformity when tested with the native patella or its own patellar component at any angle of flexion. The geometry of the anterior flange of a femoral component affects the conformity of the patellofemoral joint when articulating with the native patella. A more anatomical design of femoral component is preferable if the surgeon decides not to resurface the patella at the time of operation.


Assuntos
Artroplastia do Joelho/instrumentação , Fêmur , Articulação do Joelho/cirurgia , Prótese do Joelho , Patela , Artroplastia do Joelho/métodos , Fenômenos Biomecânicos , Simulação por Computador , Humanos , Imageamento Tridimensional/métodos , Modelos Teóricos , Desenho de Prótese , Estresse Mecânico
4.
Biochem Biophys Res Commun ; 345(3): 1131-7, 2006 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-16716256

RESUMO

Hypoxia/reoxygenation insult can be found in many tissues, including heart, brain, and tumor. It is believed that cell death may be resulted after cells were subjected to chronic hypoxia or reoxygenation after chronic hypoxia. The molecular mechanism for reoxygenation induced cell death is so far not clear and will require further study, in particular, to be distinguished from the pathways associated only with chronic hypoxia. In this study, the cell death mechanism in human squamous carcinoma A431 cells after hypoxia/reoxygenation insult is examined. It is demonstrated that although caspase-9 and -3 were activated during both hypoxia and reoxygenation, only those caspases activated during reoxygenation were responsible for reoxygenation induced apoptosis. Activation of caspase-9 and -3 during reoxygenation is believed to be triggered by the ROS formation at the time of reoxygenation. Addition of catalase during reoxygenation was found to attenuate reoxygenation induced apoptosis and caspase activation.


Assuntos
Apoptose , Caspases/metabolismo , Caspase 3 , Caspase 9 , Catalase/metabolismo , Linhagem Celular Tumoral , Fragmentação do DNA , Ativação Enzimática , Inibidores Enzimáticos/farmacologia , Humanos , Hipóxia , Oxigênio/metabolismo , Espécies Reativas de Oxigênio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...