Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38950655

RESUMO

BACKGROUND: Catheter ablation is a first-line treatment for symptomatic, recurrent supraventricular tachycardia (SVT). This study aims to demonstrate if 3D-electroanatomic mapping (EAM) during SVT ablation reduces fluoroscopy time (FT) and determine if further reductions in FT are observed longitudinally. METHODS: All cases of SVT ablation between May 2011-May 2022 at a single tertiary centre were prospectively recruited. FT between the cohorts with and without EAM were compared. Within the EAM subset, the trend of FT across the years was analysed. RESULTS: There were 1758 cases included, 563 without EAM, 1195 with EAM. EAM was associated with a longer procedure time (mean + 8.8 min, p = 0.001), but with mean reductions in FT and dose area product (DAP) by 19.6 min and 18 621 mGy*cm2 respectively (p < 0.001). There was comparable efficacy without any increase in complication rates. Over time (2011-2022), further reduction in FT of 0.9 min year on year was observed (p = 0.001). Between 2011 and 2017, there was a significant reduction in FT of 1.1 min year on year (p = 0.019), which was not observed from 2017 onwards (p = 0.061). The greatest reduction in FT was after the first year of adoption. CONCLUSION: EAM in SVT ablation reduces fluoroscopy use. FT was initially observed to reduce further over time before plateauing, likely due to increased operator experience. While there is increased interest in zero fluoroscopy SVT ablation, complementary use of fluoroscopy may still be necessary in complex cases.

2.
J Electrocardiol ; 81: 230-236, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37844372

RESUMO

BACKGROUND: Atrial fibrillation (AF) is a cause of serious morbidity such as stroke. Early detection and treatment of AF is important. Current guidelines recommend screening via opportunistic pulse taking or 12­lead electrocardiogram. Mid-term ECG patch monitors increases the sensitivity of AF detection. METHODS: The Singapore Atrial Fibrillation Study is a prospective multi-centre study aiming to study the incidence of AF in patients with no prior AF and a CHA2DS2-VASc score of at least 1, with the use of a mid-term continuous ECG monitoring device (Spyder ECG). Consecutive patients from both inpatient and outpatient settings were recruited from 3 major hospitals from May 2016 to December 2019. RESULTS: Three hundred and fifty-five patients were monitored. 6 patients (1.7%) were diagnosed with AF. There were no significant differences in total duration of monitoring between the AF and non-AF group (6.39 ± 3.19 vs 5.42 ± 2.46 days, p = 0.340). Patients with newly detected AF were more likely to have palpitations (50.0% vs 11.8%, p = 0.027). Half of the patients (n = 3, 50.0%) were diagnosed on the first day of monitoring and the rest were diagnosed after 24 h. On univariate analysis, only hyperlipidemia was associated with reduced odds of being diagnosed with AF (OR HR 0.08 CI 0.01-0.74, p = 0.025). In a group of 128 patients who underwent coronary artery bypass grafting and had post-operative ECG monitoring, 9 patients (7.0%) were diagnosed with post-operative AF. CONCLUSIONS: The use of non-invasive mid-term patch-based ECG monitoring is an effective modality for AF screening.


Assuntos
Fibrilação Atrial , Acidente Vascular Cerebral , Humanos , Eletrocardiografia , Estudos Prospectivos , Programas de Rastreamento
3.
J Arrhythm ; 38(5): 827-830, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36226093

RESUMO

Palpitations is one of the most common side effects experienced post-messenger-RNA COVID-19 vaccines. However, some patients experience significant symptoms and further workup needs to be considered. We present an interesting case of inappropriate sinus tachycardia in a fit gentleman who presented with worsening palpitations and elevated heart rate post-first and -second dose of the Pfizer/BioNTech vaccine.

4.
Pacing Clin Electrophysiol ; 45(5): 666-673, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35417608

RESUMO

AIMS: Conduction system pacing has gained steady interest over recent years. While the majority of tools and delivery techniques were developed for His bundle pacing (HBP), the feasibility and reproducibility of using these similar tools for left bundle branch pacing (LBBP) has yet to be determined. We describe our technique for performing LBBP using the Abbott Agilis HisPro™ Steerable Catheter. METHODS AND RESULTS: A series of 22 patients with a mean age of 71.7 years (16 males, 72.7%), underwent LBBP procedure with this catheter between May and October 2021. Nineteen patients (86%) had successful LBBP lead implantation. There were no major complications or mortality. CONCLUSION: The Agilis HisPro™ catheter along with the stylet driven Tendril STS Model 2088TC lead is a safe and feasible delivery system for LBBP.


Assuntos
Fascículo Atrioventricular , Terapia de Ressincronização Cardíaca , Idoso , Estimulação Cardíaca Artificial/métodos , Terapia de Ressincronização Cardíaca/métodos , Catéteres , Eletrocardiografia , Sistema de Condução Cardíaco , Humanos , Masculino , Reprodutibilidade dos Testes
7.
J Electrocardiol ; 51(4): 667-673, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29997009

RESUMO

INTRODUCTION: Mutations within SCN5A are found in a significant proportion (15-30%) of Brugada syndrome (BrS) cases and impair sodium transport across excitable cardiac cells that mediate ventricular contractions. Genetic testing offers a means to clinically assess and manage affected individuals and their family members. METHODS AND RESULTS: The proband at age 44 years old exhibited a syncopal event during exercise, and presented later with a spontaneous type-I BrS pattern on 12­lead resting electrocardiogram (ECG). Mutational analysis performed across all SCN5A exons revealed a unique three base-pair deletion p.M741_T742delinsI (c.2223_2225delGAC), in a heterozygous state in the proband and 2 siblings. This mutation was not seen in a cohort of 105 ethnicity-matched controls or in public genome databases. Patch clamp electrophysiology study conducted in TSA201 cells showed an abolishment of sodium current (INa). The proband, and several relatives, also harboured a known SCN5A variant, p.R1193Q (c.3578G>A). CONCLUSION: Our study has demonstrated the deleterious effect of a novel SCN5A mutation p.M741_T742delinsI (c.2223_2225delGAC). The findings highlight the complex effects of gender and age in phenotype manifestation. It also offers insights into improving the long-term management of BrS, and the utility of cascade genetic screening for risk stratification.


Assuntos
Síndrome de Brugada/genética , Canal de Sódio Disparado por Voltagem NAV1.5/genética , Deleção de Sequência , Adulto , Síndrome de Brugada/complicações , Feminino , Humanos , Masculino , Linhagem , Fenótipo , Síncope/etiologia
8.
Sci Rep ; 8(1): 11246, 2018 07 26.
Artigo em Inglês | MEDLINE | ID: mdl-30050137

RESUMO

Brugada syndrome (BrS) is an inherited cardiac arrhythmia commonly associated with SCN5A mutations, yet its ionic mechanisms remain unclear due to a lack of cellular models. Here, we used human induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs) from a BrS patient (BrS1) to evaluate the roles of Na+ currents (INa) and transient outward K+ currents (Ito) in BrS induced action potential (AP) changes. To understand the role of these current changes in repolarization we employed dynamic clamp to "electronically express" IK1 and restore normal resting membrane potentials and allow normal recovery of the inactivating currents, INa, ICa and Ito. HiPSC-CMs were generated from BrS1 with a compound SCN5A mutation (p. A226V & p. R1629X) and a healthy sibling control (CON1). Genome edited hiPSC-CMs (BrS2) with a milder p. T1620M mutation and a commercial control (CON2) were also studied. CON1, CON2 and BrS2, had unaltered peak INa amplitudes, and normal APs whereas BrS1, with over 75% loss of INa, displayed a loss-of-INa basal AP morphology (at 1.0 Hz) manifested by a reduced maximum upstroke velocity (by ~80%, p < 0.001) and AP amplitude (p < 0.001), and an increased phase-1 repolarization pro-arrhythmic AP morphology (at 0.1 Hz) in ~25% of cells characterized by marked APD shortening (~65% shortening, p < 0.001). Moreover, Ito densities of BrS1 and CON1 were comparable and increased from 1.0 Hz to 0.1 Hz by ~ 100%. These data indicate that a repolarization deficit could be a mechanism underlying BrS.


Assuntos
Síndrome de Brugada/fisiopatologia , Potenciais da Membrana , Miócitos Cardíacos/patologia , Potássio/metabolismo , Sódio/metabolismo , Diferenciação Celular , Humanos , Mutação , Canal de Sódio Disparado por Voltagem NAV1.5/genética , Técnicas de Patch-Clamp , Células-Tronco Pluripotentes/fisiologia
10.
J Clin Sleep Med ; 13(11): 1265-1271, 2017 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-28992834

RESUMO

STUDY OBJECTIVES: Obstructive sleep apnea (OSA) is associated with increased cardiovascular morbidity and mortality. Cardiac arrhythmias are common in patients with OSA. However, the prevalence and significance of cardiac arrhythmias in Asian patients with OSA are not well studied. The aim of this study is to determine the prevalence of cardiac arrhythmias in patients with OSA in Singapore and to evaluate possible factors that may predispose patients with OSA to arrhythmias. METHODS: A retrospective study of 2,019 patients was carried out from January 2011 to December 2012 at a sleep center in a tertiary medical center. Of the population, 1,457 patients were found to have OSA and 144 patients were found to have cardiac arrhythmias. Data collected included patient demographics, comorbidities, and polysomnogram parameters. RESULTS: The prevalence of cardiac arrhythmias in our OSA population is 8.0%, compared to that of primary snorers at 4.8% (P = .015). The univariate analysis revealed that older age, higher body mass index, comorbidities, and severity of OSA, including apnea-hypopnea index (AHI), lowest oxygen saturation (LSAT) and hypoxic time were correlated with a higher prevalence of cardiac arrhythmias (P < .05). However, the multivariate analysis showed that only age and body mass index were significantly correlated with arrhythmias. AHI, LSAT, and hypoxic time were no longer statistically significant. CONCLUSIONS: Our study demonstrated that cardiac arrhythmias are common in patients with OSA in Singapore. It also suggests that given the different demographics of our population, ethnicity may play a significant role in the development of cardiovascular disease among patients with OSA. COMMENTARY: A commentary on this article appears in this issue on page 1229.


Assuntos
Arritmias Cardíacas/epidemiologia , Apneia Obstrutiva do Sono/epidemiologia , Adulto , Comorbidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polissonografia/estatística & dados numéricos , Prevalência , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Singapura/epidemiologia
11.
J Arrhythm ; 33(3): 167-171, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28607610

RESUMO

BACKGROUND: Percutaneous transcatheter radiofrequency ablation of atrial fibrillation with remote controlled magnetic navigation (RMN) has been shown to reduce radiation exposure to patients and physicians compared with conventional manual (MAN) ablation techniques. METHODS: Catheter ablation for atrial fibrillation was performed utilizing RMN in 214 consecutive patients and MAN ablation techniques in 229 patients. We compared the fluoroscopy and procedural times between RMN and MAN catheter ablation of atrial fibrillation. Secondary objectives included comparing acute procedural success and short-term complication rates between both ablation strategies. RESULTS: Fluoroscopy time was significantly shorter in the RMN group than the MAN group (53.5±30.1 vs 68.1±27.6 min, respectively; p<0.01); however, the total procedural time was longer in the RMN group (280.2±74.4 min vs 213.1±64.75, respectively; p>0.001). Further subgroup analysis of the most recent 50 ablations each from the RMN and MAN groups, to attenuate the RMN learning curve effect, showed an even greater difference in fluoroscopy time (RMN vs MAN: 53.5±30.1 vs 68.1±27.6 min), though a consistently longer procedure time with RMN (249.5±65.5 vs 186.3±65.6 min, respectively). The acute procedural success rate was comparable between the groups (98.6% vs 95.6%, respectively; p=0.07). The rates of acute complications were similar in both groups (2.3% vs 4.8%, respectively; p=0.16). CONCLUSIONS: In radiofrequency ablation of atrial fibrillation, RMN appears to significantly reduce fluoroscopy time compared with conventional MAN ablation, though at a cost of increased total procedural time, with comparable acute success rates and safety profile. A reduction in procedure and fluoroscopy times is possible with gaining experience.

13.
Singapore Med J ; 57(7): 372-7, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27439396

RESUMO

INTRODUCTION: Remote monitoring of cardiac implantable electronic devices (CIED) has been shown to improve patient safety and reduce in-office visits. We report our experience with remote monitoring via the Medtronic CareLink(®) network. METHODS: Patients were followed up for six months with scheduled monthly remote monitoring transmissions in addition to routine in-office checks. The efficacy of remote monitoring was evaluated by recording compliance to transmissions, number of device alerts requiring intervention and time from transmission to review. Questionnaires were administered to evaluate the experiences of patients, physicians and medical technicians. RESULTS: A total of 57 patients were enrolled; 16 (28.1%) had permanent pacemakers, 34 (59.6%) had implantable cardioverter defibrillators and 7 (12.3%) had cardiac resynchronisation therapy defibrillators. Overall, of 334 remote transmissions scheduled, 73.7% were on time, 14.5% were overdue and 11.8% were missed. 84.6% of wireless transmissions were on time, compared to 53.8% of non-wireless transmissions. Among all transmissions, 4.4% contained alerts for which physicians were informed and only 1.8% required intervention. 98.6% of remote transmissions were reviewed by the second working day. 73.2% of patients preferred remote monitoring. Physicians agreed that remote transmissions provided information equivalent to in-office checks 97.1% of the time. 77.8% of medical technicians felt that remote monitoring would help the hospital improve patient management. No adverse events were reported. CONCLUSION: Remote monitoring of CIED is safe and feasible. It has possible benefits to patient safety through earlier detection of arrhythmias or device malfunction, permitting earlier intervention. Wireless remote monitoring, in particular, may improve compliance to device monitoring. Patients may prefer remote monitoring due to possible improvements in quality of life.


Assuntos
Arritmias Cardíacas/diagnóstico , Desfibriladores Implantáveis , Consulta Remota/métodos , Idoso , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica/métodos , Marca-Passo Artificial , Segurança do Paciente , Projetos Piloto , Estudos Prospectivos , Qualidade de Vida , Singapura , Inquéritos e Questionários
14.
Singapore Med J ; 57(4): 182-7, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27075476

RESUMO

INTRODUCTION: Device therapy is efficacious in preventing sudden cardiac death (SCD) in patients with reduced ejection fraction. However, few who need the device eventually opt to undergo implantation and even fewer reconsider their decisions after deliberation. This is due to many factors, including unresolved patient barriers. This study identified the factors that influenced patients' decision to decline implantable cardioverter defibrillator (ICD) implantation, and those that influenced patients who initially declined an implant to reconsider having one. METHODS: A single-centre survey was conducted among 240 patients who had heart failure with reduced ejection fraction and met the ICD implantation criteria, but had declined ICD implantation. RESULTS: Participants who refused ICD implantation were mostly male (84%), Chinese (71%), married (72%), currently employed (54%), and had up to primary or secondary education (78%) and monthly income of < SGD 3,000 (51%). Those who were more likely to reconsider their decision were aware that SCD was a consequence of heart failure with reduced ejection fraction, knowledgeable of the preventive role of ICDs, currently employed and aware that their doctor strongly recommended the implant. Based on multivariate analysis, knowledge of the role of ICDs for primary prophylaxis was the most important factor influencing patient decision. CONCLUSION: This study identified the demographic and social factors of patients who refused ICD therapy. Knowledge of the role of ICDs in preventing SCD was found to be the strongest marker for reconsidering ICD implantation. Measures to address this information gap may lead to higher rates of ICD implantation.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Insuficiência Cardíaca/terapia , Prevenção Primária/métodos , Volume Sistólico/fisiologia , Estudos Transversais , Feminino , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Singapura/epidemiologia , Taxa de Sobrevida/tendências
15.
Singapore Med J ; 57(7): 390-5, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26805664

RESUMO

INTRODUCTION: The use of non-fluoroscopic systems (NFS) to guide radiofrequency catheter ablation (RFCA) for the treatment of supraventricular tachycardia (SVT) is associated with lower radiation exposure. This study aimed to determine if NFS reduces fluoroscopy time, radiation dose and procedure time. METHODS: We prospectively enrolled patients undergoing RFCA for SVT. NFS included EnSiteTM NavXTM or CARTO® mapping. We compared procedure and fluoroscopy times, and radiation exposure between NFS and conventional fluoroscopy (CF) cohorts. Procedural success, complications and one-year success rates were reported. RESULTS: A total of 200 patients over 27 months were included and RFCA was guided by NFS for 79 patients; those with atrioventricular nodal reentrant tachycardia (AVNRT), left-sided atrioventricular reentrant tachycardia (AVRT) and right-sided AVRT were included (n = 101, 63 and 36, respectively). Fluoroscopy times were significantly lower with NFS than with CF (10.8 ± 11.1 minutes vs. 32.0 ± 27.5 minutes; p < 0.001). The mean fluoroscopic dose area product was also significantly reduced with NFS (NSF: 5,382 ± 5,768 mGy*cm2 vs. CF: 21,070 ± 23,311 mGy*cm2; p < 0.001); for all SVT subtypes. There was no significant reduction in procedure time, except for left-sided AVRT ablation (NFS: 79.2 minutes vs. CF: 116.4 minutes; p = 0.001). Procedural success rates were comparable (NFS: 97.5% vs. CF: 98.3%) and at one-year follow-up, there was no significant difference in the recurrence rates (NFS: 5.2% vs. CF: 4.2%). No clinically significant complications were observed in both groups. CONCLUSION: The use of NFS for RFCA for SVT is safe, with significantly reduced radiation dose and fluoroscopy time.


Assuntos
Ablação por Cateter/métodos , Taquicardia Supraventricular/terapia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Doses de Radiação , Radiação Ionizante , Taquicardia por Reentrada no Nó Atrioventricular/terapia , Resultado do Tratamento , Adulto Jovem
17.
Europace ; 18(6): 897-904, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25829473

RESUMO

AIMS: Brugada syndrome (BrS) is a rare heritable ventricular arrhythmia. Genetic defects in SCN5A, a gene that encodes the α-subunit of the sodium ion channel Nav1.5, are present in 15-30% of BrS cases. SCN5A remains by far, the highest yielding gene for BrS. We studied a young male who presented with syncope at age 11. This proband was screened for possible disease causing SCN5A mutations. The inheritance pattern was also examined amongst his first-degree family members. METHODS AND RESULTS: The proband had a baseline electrocardiogram that showed Type 2 BrS changes, which escalated to a characteristic Type I BrS pattern during a treadmill test before polymorphic ventricular tachycardia onset at a cycle length of 250 ms. Mutational analysis across all 29 exons in SCN5A of the proband and first-degree relatives of the family revealed that the proband inherited a compound heterozygote mutation in SCN5A, specifically p.A226V and p.R1629X from each parent. To further elucidate the functional changes arising through these mutations, patch-clamp electrophysiology was performed in TSA201 cells expressing the mutated SCN5A channels. The p.A226V mutation significantly reduced peak sodium current (INa) to 24% of wild type (WT) whereas the p.R1629X mutation abolished the current. To mimic the functional state in our proband, functional expression of the compound variants A226V + R1629X resulted in overall peak INa of only 13% of WT (P < 0.01). CONCLUSION: Our study is the first to report a SCN5A compound heterozygote in a Singaporean Chinese family. Only the proband carrying both mutations displayed the BrS phenotype, thus providing insights into the expression and penetrance of BrS in an Asian setting.


Assuntos
Síndrome de Brugada/genética , Heterozigoto , Canal de Sódio Disparado por Voltagem NAV1.5/genética , Taquicardia Ventricular/genética , Adolescente , Adulto , Povo Asiático , Linhagem Celular , Análise Mutacional de DNA , Eletrocardiografia , Éxons , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Mutação de Sentido Incorreto , Linhagem , Fenótipo , Singapura , Adulto Jovem
18.
Singapore Med J ; 56(10): 580-5, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26512151

RESUMO

Transvenous implantable cardioverter defibrillators are a type of implantable cardiac device. They are effective at reducing total and arrhythmic mortality in patients at risk of sudden cardiac death. Subcutaneous implantable cardioverter defibrillators (S-ICDs) are a new alternative that avoids the disadvantages of transvenous lead placement. In this case series, we report on the initial feasibility and safety of S-ICD implantation in Singapore.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/estatística & dados numéricos , Adulto , Eletrofisiologia , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Segurança do Paciente , Implantação de Prótese , Singapura , Taquicardia Ventricular , Fibrilação Ventricular
19.
Singapore Med J ; 56(1): e10-3, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25640105

RESUMO

A patient with non-ischaemic cardiomyopathy, and pre-existing atypical atrial flutter and left bundle branch block, developed broad complex tachycardia. In this unique and uncommon case of double tachycardia, we discuss the diagnostic approach of ventricular tachycardia in patients with broad complex tachycardia, and the use of different contemporary algorithms to help diagnose ventricular tachycardia and differentiate it from supraventricular tachycardia with aberrant conduction.


Assuntos
Taquicardia Supraventricular/diagnóstico , Taquicardia Ventricular/diagnóstico , Algoritmos , Flutter Atrial/complicações , Flutter Atrial/diagnóstico , Bloqueio de Ramo/fisiopatologia , Cardiomiopatias/complicações , Cardiomiopatias/diagnóstico , Diagnóstico Diferencial , Ecocardiografia , Eletrocardiografia , Humanos , Masculino , Pessoa de Meia-Idade , Taquicardia Supraventricular/fisiopatologia , Taquicardia Ventricular/fisiopatologia
20.
Europace ; 17 Suppl 2: ii63-8, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26842117

RESUMO

AIMS: The safety and feasibility of a subcutaneous implantable cardioverter-defibrillator (S-ICD) has been demonstrated in the treatment of life-threatening ventricular tachyarrhythmias (VT). Nonetheless, its safety and feasibility in an Asian population with smaller body-build is unclear. METHODS AND RESULTS: Twenty-one Asian patients who underwent S-ICD from 1 April 2014 to 2 February 2015 in five institutions in Hong Kong and Singapore were retrospectively reviewed. Twenty-one patients with a mean age of 50.0 ± 14.1 years (range 29-77 years, 82.6% male) were included. Among them, 17 (81.0%) were Chinese, 3 (14.3%) were Malay, and 1 (4.8%) was Indian. Their mean body mass index was 23.0 ± 4.0 kg/m(2). An S-ICD was implanted for primary and secondary prevention in 13 (61.9%) and 8 (38.1%) patients, respectively. The indications included Brugada syndrome (n = 6, 28.6%), ischaemic cardiomyopathy (CMP, n = 6, 28.6%), dilated CMP (n = 4, 19.0%), hypertrophic CMP (n = 2, 9.5%), and idiopathic ventricular fibrillation (n = 2, 9.5%). Three patients (14.3%) had prior infected transvenous ICD. There were no acute complications but eight wound complications (persistent wound bleeding requiring intervention = 2; delayed wound healing: upper sternal wound = 3; generator site = 1; local wound infection = 2) were observed in six (28.2%) patients. After a mean follow-up of 107.2 ± 81.3 days (range of 14-254 days), one patient underwent three successful appropriate shocks for treatment of VTs. No inappropriate therapy was documented. CONCLUSION: Our initial experience shows that S-ICD is a feasible treatment for VT among an Asian population with smaller body-build. There was nonetheless a relatively high rate of wound complications.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/efeitos adversos , Falha de Equipamento , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/prevenção & controle , Infecções Relacionadas à Prótese/etiologia , Desenho de Equipamento , Análise de Falha de Equipamento , Estudos de Viabilidade , Feminino , Hong Kong , Humanos , Masculino , Segurança do Paciente , Projetos Piloto , Infecções Relacionadas à Prótese/diagnóstico , Estudos Retrospectivos , Singapura , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...