Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 66
Filtrar
1.
Bioengineering (Basel) ; 11(3)2024 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-38534507

RESUMO

Medical response to military conflicts, natural disasters, and humanitarian crises are challenged by operational logistics with unreliable supply chains, delayed medical evacuation, and compatibility of the disparate medical equipment and consumables. In these environments, stocks of supplies will become more quickly depleted and the need for equipment parts increases secondary to their higher likelihood for failure from overuse. Additive Manufacturing (AM), or 3D printing, at or closer to the point-of-need provides potential solutions to mitigate these logistics challenges. AM's ability to tailor the resultant product through computer design enables real-time modification of a product to meet a specific situation. In this study, we deployed two different 3D printers to an arctic locale to demonstrate the utility of 3D printing and bioprinting in austere environments. Deployment of AM solutions in austere environments will likely impact medical care following natural disasters and conflicts with contested logistics. The work presented here furthers the readiness status of AM for use in austere environments to manufacture medical equipment parts and demonstrates its potential use for tissue engineering and advanced medical treatments in remote environments.

2.
Pharmaceuticals (Basel) ; 16(12)2023 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-38139845

RESUMO

Micro-computed tomography (microCT) is a common tool for the visualization of the internal composition of organic tissues. Collagen comprises approximately 25-35% of the whole-body protein content in mammals, and the structure and arrangement of collagen fibers contribute significantly to the integrity of tissues. Collagen type I is also frequently used as a key structural component in tissue-engineered and bioprinted tissues. However, the imaging of collagenous tissues is limited by their inherently low X-ray attenuation, which makes them indistinguishable from most other soft tissues. An imaging contrast agent that selectively alters X-ray attenuation is thus essential to properly visualize collagenous tissue using a standard X-ray tube microCT scanner. This review compares various contrast-enhanced techniques reported in the literature for MicroCT visualization of collagen-based tissues. An ideal microCT contrast agent would meet the following criteria: (1) it diffuses through the tissue quickly; (2) it does not deform or impair the object being imaged; and (3) it provides sufficient image contrast for reliable visualization of the orientation of individual fibers within the collagen network. The relative benefits and disadvantages of each method are discussed. Lugol's solution (I3K), phosphotungstic acid (H3PW12O40), mercury(II) chloride (HgCl2), and Wells-Dawson polyoxometalates came closest to fitting the criteria. While none of the contrast agents discussed in the literature met all criteria, each one has advantages to consider in the context of specific lab capabilities and imaging priorities.

3.
Transl Psychiatry ; 13(1): 289, 2023 08 31.
Artigo em Inglês | MEDLINE | ID: mdl-37652994

RESUMO

Mild traumatic brain injury (mTBI) is a significant health burden among military service members. Although mTBI was once considered relatively benign compared to more severe TBIs, a growing body of evidence has demonstrated the devastating neurological consequences of mTBI, including chronic post-concussion symptoms and deficits in cognition, memory, sleep, vision, and hearing. The discovery of reliable biomarkers for mTBI has been challenging due to under-reporting and heterogeneity of military-related mTBI, unpredictability of pathological changes, and delay of post-injury clinical evaluations. Moreover, compared to more severe TBI, mTBI is especially difficult to diagnose due to the lack of overt clinical neuroimaging findings. Yet, advanced neuroimaging techniques using magnetic resonance imaging (MRI) hold promise in detecting microstructural aberrations following mTBI. Using different pulse sequences, MRI enables the evaluation of different tissue characteristics without risks associated with ionizing radiation inherent to other imaging modalities, such as X-ray-based studies or computerized tomography (CT). Accordingly, considering the high morbidity of mTBI in military populations, debilitating post-injury symptoms, and lack of robust neuroimaging biomarkers, this review (1) summarizes the nature and mechanisms of mTBI in military settings, (2) describes clinical characteristics of military-related mTBI and associated comorbidities, such as post-traumatic stress disorder (PTSD), (3) highlights advanced neuroimaging techniques used to study mTBI and the molecular mechanisms that can be inferred, and (4) discusses emerging frontiers in advanced neuroimaging for mTBI. We encourage multi-modal approaches combining neuropsychiatric, blood-based, and genetic data as well as the discovery and employment of new imaging techniques with big data analytics that enable accurate detection of post-injury pathologic aberrations related to tissue microstructure, glymphatic function, and neurodegeneration. Ultimately, this review provides a foundational overview of military-related mTBI and advanced neuroimaging techniques that merit further study for mTBI diagnosis, prognosis, and treatment monitoring.


Assuntos
Concussão Encefálica , Lesões Encefálicas Traumáticas , Militares , Humanos , Concussão Encefálica/complicações , Concussão Encefálica/diagnóstico por imagem , Neuroimagem , Cognição
4.
HardwareX ; 14: e00433, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37424929

RESUMO

Injuries to the meniscus are common and can impair physical activities. Bioprinted meniscal tissue offers an attractive alternative to donor tissue for meniscal repair but achieving the strength of native tissue is a challenge. Here we report the development of a tissue engineering bioreactor designed to apply repetitive force which may lead to an increase in the compressive modulus and durability of bioprinted meniscal tissues. The modular bioreactor system is composed of a sterilizable tissue culture vessel together with a dock that applies and measures mechanical force. The culture vessel allows for simultaneous compression cycling of two anatomically sized menisci. Using a hybrid linear actuator with a stepper motor, the dock can apply up to 300 N of force at speeds up to 20 mm/s, corresponding to the upper limits of anatomical force and motion in the knee. An interchangeable 22 N load cell was mated between the culture vessel and the dock to log changes in force. Both the culture vessel and dock are maintained in a standard cell culture incubator to provide heat and CO2, while the dock is powered and controlled externally using a step motor drive and customized software.

5.
Magn Reson Med ; 90(5): 1789-1801, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37335831

RESUMO

PURPOSE: We hypothesized that the time-dependent diffusivity at short diffusion times, as measured by oscillating gradient spin echo (OGSE) diffusion MRI, can characterize tissue microstructures in glioma patients. THEORY AND METHODS: Five adult patients with known diffuse glioma, including two pre-surgical and three with new enhancing lesions after treatment for high-grade glioma, were scanned in an ultra-high-performance gradient 3.0T MRI system. OGSE diffusion MRI at 30-100 Hz and pulsed gradient spin echo diffusion imaging (approximated as 0 Hz) were obtained. The ADC and trace-diffusion-weighted image at each acquired frequency were calculated, that is, ADC (f) and TraceDWI (f). RESULTS: In pre-surgical patients, biopsy-confirmed solid enhancing tumor in a high-grade glioblastoma showed higher ADC ( f ) ADC ( 0 Hz ) $$ \frac{\mathrm{ADC}\ (f)}{\mathrm{ADC}\ \left(0\ \mathrm{Hz}\right)} $$ and lower TraceDWI ( f ) TraceDWI ( 0 Hz ) $$ \frac{\mathrm{TraceDWI}\ (f)}{\mathrm{TraceDWI}\ \left(0\ \mathrm{Hz}\right)} $$ , compared to that at same OGSE frequency in a low-grade astrocytoma. In post-treatment patients, the enhancing lesions of two patients who were diagnosed with tumor progression contained more voxels with high ADC ( f ) ADC ( 0 Hz ) $$ \frac{\mathrm{ADC}\ (f)}{\mathrm{ADC}\ \left(0\ \mathrm{Hz}\right)} $$ and low TraceDWI ( f ) TraceDWI ( 0 Hz ) $$ \frac{\mathrm{TraceDWI}\left(\mathrm{f}\right)}{\mathrm{TraceDWI}\left(0\ \mathrm{Hz}\right)} $$ , compared to the enhancing lesions of a patient who was diagnosed with treatment effect. Non-enhancing T2 signal abnormality lesions in both the pre-surgical high-grade glioblastoma and post-treatment tumor progressions showed regions with high ADC ( f ) ADC ( 0 Hz ) $$ \frac{\mathrm{ADC}\ (f)}{\mathrm{ADC}\ \left(0\ \mathrm{Hz}\right)} $$ and low TraceDWI ( f ) TraceDWI ( 0 Hz ) $$ \frac{\mathrm{TraceDWI}\ \left(\mathrm{f}\right)}{\mathrm{TraceDWI}\ \left(0\ \mathrm{Hz}\right)} $$ , consistent with infiltrative tumor. The solid tumor of the glioblastoma, the enhancing lesions of post-treatment tumor progressions, and the suspected infiltrative tumors showed high diffusion time-dependency from 30 to 100 Hz, consistent with high intra-tumoral volume fraction (cellular density). CONCLUSION: Different characteristics of OGSE-based time-dependent diffusivity can reveal heterogenous tissue microstructures that indicate cellular density in glioma patients.


Assuntos
Glioblastoma , Glioma , Adulto , Humanos , Glioblastoma/diagnóstico por imagem , Glioblastoma/cirurgia , Imagem de Difusão por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/métodos , Glioma/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Difusão
6.
Toxins (Basel) ; 15(3)2023 03 09.
Artigo em Inglês | MEDLINE | ID: mdl-36977098

RESUMO

Shiga toxins (Stxs) produced by ingested E. coli can induce hemolytic uremic syndrome after crossing the intact intestinal barrier, entering the bloodstream, and targeting endothelial cells in the kidney. The method(s) by which the toxins reach the bloodstream are not fully defined. Here, we used two polarized cell models to evaluate Stx translocation: (i) a single-layer primary colonic epithelial cell model and (ii) a three-cell-layer model with colonic epithelial cells, myofibroblasts, and colonic endothelial cells. We traced the movement of Stx types 1a and 2a across the barrier models by measuring the toxicity of apical and basolateral media on Vero cells. We found that Stx1a and Stx2a crossed both models in either direction. However, approximately 10-fold more Stx translocated in the three-layer model as compared to the single-layer model. Overall, the percentage of toxin that translocated was about 0.01% in the epithelial-cell-only model but up to 0.09% in the three-cell-layer model. In both models, approximately 3- to 4-fold more Stx2a translocated than Stx1a. Infection of the three-cell-layer model with Stx-producing Escherichia coli (STEC) strains showed that serotype O157:H7 STEC reduced barrier function in the model and that the damage was not dependent on the presence of the eae gene. Infection of the three-layer model with O26:H11 STEC strain TW08571 (Stx1a+ and Stx2a+), however, allowed translocation of modest amounts of Stx without reducing barrier function. Deletion of stx2a from TW08571 or the use of anti-Stx1 antibody prevented translocation of toxin. Our results suggest that single-cell models may underestimate the amount of Stx translocation and that the more biomimetic three-layer model is suited for Stx translocation inhibitor studies.


Assuntos
Infecções por Escherichia coli , Escherichia coli Shiga Toxigênica , Animais , Chlorocebus aethiops , Toxina Shiga/metabolismo , Células Vero , Células Endoteliais/metabolismo , Escherichia coli Shiga Toxigênica/metabolismo , Toxinas Shiga/metabolismo
7.
Mil Med ; 2023 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-36734042

RESUMO

INTRODUCTION: Known as the "golden hour," survival of most critically injured patients is highly dependent on providing the required treatment within the first hour of injury. Recent technological advances in additive manufacturing (also known as three-dimensional [3D] printing) allow for austere deployment and point-of-care rapid fabrication of a variety of medical supplies, including human tissues and bioactive bandages, in prolonged field care scenarios. In this pilot project, our aim was to investigate the ability to 3D print a range of potential biomedical supplies and solutions in an austere field environment. MATERIALS AND METHODS: We specifically designed and fabricated novel surgical tools, bioactive bandages, objects (screw and anatomic models), and human meniscal tissue in an austere African desert environment. A total of seven packages were sent using a commercial carrier directly to the end destination. A multi-tool ruggedized 3D printer was used as the manufacturing platform for all objects fabricated downrange. Human mesenchymal stem cells were shipped for 3D bioprinting of human menisci and bioactive bandages. Design and fabrication for all 3D-printed products utilized computer-aided design (CAD) tools. RESULTS: Initial shipment from a single U.S. site to the sub-Saharan Africa location was relatively prompt, taking an average of 4.7 days to deliver three test packages. However, the actual delivery of the seven packages from Orlando, FL, to the same sub-Saharan Africa site took an average of 16 days (range 7-23 days). The ruggedized printer successfully fabricated relevant medical supplies using biocompatible filament, bioink hydrogels, and stem cell-loaded bioinks. This prototype did not, however, have the capacity to provide a sterile environment. A multi-material complete bandage was 3D printed using polyamide polyolefin and cellulose, live cells, neomycin salve, and adhesive. The bandage, wound covering backing, and adhesive backing print took under 2 min to 3D print. Surgical instrument CAD files were based on commercially available medical-grade stainless-steel instruments. The screw CAD file was downloaded from the NIH 3D Print Exchange website. The prints of the two surgical tools and screw using thermoplastic material were successful. Menisci, relatively complex forms of the cartilage, were 3D bioprinted with a gel that held their form well after printing and were then solidified slightly using a cross-linking solution. After 2 min of solidification, it was possible to remove and handle the menisci. CONCLUSION: The current and future challenges of prolonged field care need to be addressed with new techniques, training, and technology. Ruggedized, deployable 3D printers allow for the direct fabrication of medical tools, supplies, and biological solutions for austere use. Delivery of packages can vary, and attention to routes and location is key, especially for transit of time-sensitive perishable supplies such as live cells. The significance of this study provides the real possibility to 3D print "just-in-time" medical solutions tailored to the need of an individual service member in any environment. This is a potentially exciting opportunity to bring critical products to the war front.

8.
Magn Reson Med ; 89(1): 262-275, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36129000

RESUMO

PURPOSE: Asymmetric gradient coils introduce zeroth- and first-order concomitant field terms, in addition to higher-order terms common to both asymmetric and symmetric gradients. Salient to compensation strategies is the accurate calibration of the concomitant field spatial offset parameters for asymmetric coils. A method that allows for one-time calibration of the offset parameters is described. THEORY AND METHODS: A modified phase contrast pulse sequence with single-sided bipolar flow encoding is proposed to calibrate the offsets for asymmetric, transverse gradient coils. By fitting the measured phase offsets to different gradient amplitudes, the spatial offsets were calculated by fitting the phase variation. This was used for calibrating real-time pre-emphasis compensation of the zeroth- and first-order concomitant fields. RESULTS: Image quality improvement with the proposed corrections was demonstrated in phantom and healthy volunteers with non-Cartesian and Cartesian trajectory acquisitions. Concomitant field compensation using the calibrated offsets resulted in a residual phase error <3% at the highest gradient amplitude and demonstrated substantial reduction of image blur and slice position/selection artifacts. CONCLUSIONS: The proposed implementation provides an accurate method for calibrating spatial offsets that can be used for real-time concomitant field compensation of zeroth and first-order terms, substantially reducing artifacts without retrospective correction or sequence specific waveform modifications.


Assuntos
Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Humanos , Processamento de Imagem Assistida por Computador/métodos , Calibragem , Estudos Retrospectivos , Imageamento por Ressonância Magnética/métodos , Artefatos , Imagens de Fantasmas
9.
Health Sci Rep ; 4(4): e406, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34761123

RESUMO

BACKGROUND AND AIMS: Sleepiness influences alertness and cognitive functioning and impacts many aspects of medical care, including clinical reasoning. However, dual processing theory suggests that sleepiness will impact clinical reasoning differently in different individual, depending on their level of experience with the given condition. Our aim, therefore, was to examine the association between clinical reasoning, neuroanatomical activation, and sleepiness in senior medical students. METHODS: Our methodology replicated an earlier study but with novices rather than board-certified physicians. Eighteen final-year medical students answered validated multiple-choice questions (MCQs) during an fMRI scan. Each MCQ was projected in three phases: reading, answering, and reflection (modified think aloud). Echo-planar imaging (EPI) scans gave a time series that reflected blood oxygenation level dependent (BOLD) signal in each location (voxel) within the brain. Sleep data were collected via self-report (Epworth Sleepiness Scale) and actigraphy. These data were correlated with answer accuracy using Pearson correlation. RESULTS: Analysis revealed an increased BOLD signal in the right dorsomedial prefrontal cortex (P < .05) during reflection (Phase 3) associated with increased self-reported sleepiness (ESS) immediately before scanning. Covariate analysis also revealed that increased BOLD signal in the right supramarginal gyrus (P < .05) when reflecting (Phase 3) was associated with increased correct answer response time. Both patterns indicate effortful analytic (System 2) reasoning. CONCLUSION: Our findings that novices use System 2 thinking for clinical reasoning and even a little (perceived) sleepiness influences their clinical reasoning ability to suggest that the parameters for safe working may be different for novices (eg, junior doctors) and experienced physicians.

10.
Biomater Biosyst ; 4: 100026, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36824574

RESUMO

The meniscus is a key stabilizing tissue of the knee that facilitates proper tracking and movement of the knee joint and absorbs stresses related to physical activity. This review article describes the biology, structure, and functions of the human knee meniscus, common tears and repair approaches, and current research and development approaches using modern methods to fabricate a scaffold or tissue engineered meniscal replacement. Meniscal tears are quite common, often resulting from sports or physical training, though injury can result without specific contact during normal physical activity such as bending or squatting. Meniscal injuries often require surgical intervention to repair, restore basic functionality and relieve pain, and severe damage may warrant reconstruction using allograft transplants or commercial implant devices. Ongoing research is attempting to develop alternative scaffold and tissue engineered devices using modern fabrication techniques including three-dimensional (3D) printing which can fabricate a patient-specific meniscus replacement. An ideal meniscal substitute should have mechanical properties that are close to that of natural human meniscus, and also be easily adapted for surgical procedures and fixation. A better understanding of the organization and structure of the meniscus as well as its potential points of failure will lead to improved design approaches to generate a suitable and functional replacement.

11.
Mil Med ; 185(9-10): e1510-e1519, 2020 09 18.
Artigo em Inglês | MEDLINE | ID: mdl-32514549

RESUMO

INTRODUCTION: Traditionally, tissue engineering techniques have largely focused on 2D cell culture models-monolayers of immortalized or primary cells growing on tissue culture plastic. Although these techniques have proven useful in research, they often lack physiological validity, because of the absence of fundamental tissue properties, such as multicellular organization, specialized extracellular matrix structures, and molecular or force gradients essential to proper physiological function. More recent advances in 3D cell culture methods have facilitated the development of more complex physiological models and tissue constructs; however, these often rely on self-organization of cells (bottom-up design), and the range of tissue construct size and complexity generated by these methods remains relatively limited. By borrowing from advances in the additive manufacturing field, 3D bioprinting techniques are enabling top-down design and fabrication of cellular constructs with controlled sizing, spacing, and chemical functionality. The high degree of control over engineered tissue architecture, previously unavailable to researchers, enables the generation of more complex, physiologically relevant 3D tissue constructs. Three main 3D bioprinting techniques are reviewed-extrusion, droplet-based, and laser-assisted bioprinting techniques are among the more robust 3D bioprinting techniques, each with its own strengths and weaknesses. High complexity tissue constructs created through 3D bioprinting are opening up new avenues in tissue engineering, regenerative medicine, and physiological model systems for researchers in the military medicine community. MATERIALS AND METHODS: Recent primary literature and reviews were selected to provide a broad overview of the field of 3D bioprinting and illustrate techniques and examples of 3D bioprinting relevant to military medicine. References were selected to illustrate specific examples of advances and potential military medicine applications in the 3D bioprinting field, rather than to serve as a comprehensive review. RESULTS: Three classes of 3D bioprinting techniques were reviewed: extrusion, droplet-based, and laser-assisted bioprinting. Advantages, disadvantages, important considerations, and constraints of each technique were discussed. Examples from the primary literature were given to illustrate the techniques. Relevant applications of 3D bioprinting to military medicine, namely tissue engineering/regenerative medicine and new models of physiological systems, are discussed in the context of advancing military medicine. CONCLUSIONS: 3D bioprinting is a rapidly evolving field that provides researchers the ability to build tissue constructs that are more complex and physiologically relevant than traditional 2D culture methods. Advances in bioprinting techniques, bioink formulation, and cell culture methods are being translated into new paradigms in tissue engineering and physiological system modeling, advancing the state of the art, and increasing construct availability to the military medicine research community.


Assuntos
Bioimpressão , Medicina Militar , Impressão Tridimensional , Medicina Regenerativa , Engenharia Tecidual
12.
Magn Reson Med ; 84(2): 950-965, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32011027

RESUMO

PURPOSE: We investigate the importance of high gradient-amplitude and high slew-rate on oscillating gradient spin echo (OGSE) diffusion imaging for human brain imaging and evaluate human brain imaging with OGSE on the MAGNUS head-gradient insert (200 mT/m amplitude and 500 T/m/s slew rate). METHODS: Simulations with cosine-modulated and trapezoidal-cosine OGSE at various gradient amplitudes and slew rates were performed. Six healthy subjects were imaged with the MAGNUS gradient at 3T with OGSE at frequencies up to 100 Hz and b = 450 s/mm2 . Comparisons were made against standard pulsed gradient spin echo (PGSE) diffusion in vivo and in an isotropic diffusion phantom. RESULTS: Simulations show that to achieve high frequency and b-value simultaneously for OGSE, high gradient amplitude, high slew rates, and high peripheral nerve stimulation limits are required. A strong linear trend for increased diffusivity (mean: 8-19%, radial: 9-27%, parallel: 8-15%) was observed in normal white matter with OGSE (20 Hz to 100 Hz) as compared to PGSE. Linear fitting to frequency provided excellent correlation, and using a short-range disorder model provided radial long-term diffusivities of D∞,MD = 911 ± 72 µm2 /s, D∞,PD = 1519 ± 164 µm2 /s, and D∞,RD = 640 ± 111 µm2 /s and correlation lengths of lc,MD = 0.802 ± 0.156 µm, lc,PD = 0.837 ± 0.172 µm, and lc,RD = 0.780 ± 0.174 µm. Diffusivity changes with OGSE frequency were negligible in the phantom, as expected. CONCLUSION: The high gradient amplitude, high slew rate, and high peripheral nerve stimulation thresholds of the MAGNUS head-gradient enables OGSE acquisition for in vivo human brain imaging.


Assuntos
Encéfalo , Imagem de Difusão por Ressonância Magnética , Encéfalo/diagnóstico por imagem , Difusão , Humanos , Neuroimagem , Imagens de Fantasmas
13.
Magn Reson Med ; 83(1): 352-366, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31385628

RESUMO

PURPOSE: To establish peripheral nerve stimulation (PNS) thresholds for an ultra-high performance magnetic field gradient subsystem (simultaneous 200-mT/m gradient amplitude and 500-T/m/s gradient slew rate; 1 MVA per axis [MAGNUS]) designed for neuroimaging with asymmetric transverse gradients and 42-cm inner diameter, and to determine PNS threshold dependencies on gender, age, patient positioning within the gradient subsystem, and anatomical landmarks. METHODS: The MAGNUS head gradient was installed in a whole-body 3T scanner with a custom 16-rung bird-cage transmit/receive RF coil compatible with phased-array receiver brain coils. Twenty adult subjects (10 male, mean ± SD age = 40.4 ± 11.1 years) underwent the imaging and PNS study. The tests were repeated by displacing subject positions by 2-4 cm in the superior-inferior and anterior-posterior directions. RESULTS: The x-axis (left-right) yielded mostly facial stimulation, with mean ΔGmin = 111 ± 6 mT/m, chronaxie = 766 ± 76 µsec. The z-axis (superior-inferior) yielded mostly chest/shoulder stimulation (123 ± 7 mT/m, 620 ± 62 µsec). Y-axis (anterior-posterior) stimulation was negligible. X-axis and z-axis thresholds tended to increase with age, and there was negligible dependency with gender. Translation in the inferior and posterior directions tended to increase the x-axis and z-axis thresholds, respectively. Electric field simulations showed good agreement with the PNS results. Imaging at MAGNUS gradient performance with increased PNS threshold provided a 35% reduction in noise-to-diffusion contrast as compared with whole-body performance (80 mT/m gradient amplitude, 200 T/m/sec gradient slew rate). CONCLUSION: The PNS threshold of MAGNUS is significantly higher than that for whole-body gradients, which allows for diffusion gradients with short rise times (under 1 msec), important for interrogating brain microstructure length scales.


Assuntos
Encéfalo/diagnóstico por imagem , Estimulação Elétrica , Campos Magnéticos , Neuroimagem/instrumentação , Neuroimagem/métodos , Nervos Periféricos/diagnóstico por imagem , Sistema Nervoso Periférico/diagnóstico por imagem , Adulto , Algoritmos , Desenho de Equipamento , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Nervos Periféricos/fisiologia , Imagens de Fantasmas , Reprodutibilidade dos Testes , Imagem Corporal Total
14.
Magn Reson Med ; 83(6): 2356-2369, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31763726

RESUMO

PURPOSE: To develop a highly efficient magnetic field gradient coil for head imaging that achieves 200 mT/m and 500 T/m/s on each axis using a standard 1 MVA gradient driver in clinical whole-body 3.0T MR magnet. METHODS: A 42-cm inner diameter head-gradient used the available 89- to 91-cm warm bore space in a whole-body 3.0T magnet by increasing the radial separation between the primary and the shield coil windings to 18.6 cm. This required the removal of the standard whole-body gradient and radiofrequency coils. To achieve a coil efficiency ~4× that of whole-body gradients, a double-layer primary coil design with asymmetric x-y axes, and symmetric z-axis was used. The use of all-hollow conductor with direct fluid cooling of the gradient coil enabled ≥50 kW of total heat dissipation. RESULTS: This design achieved a coil efficiency of 0.32 mT/m/A, allowing 200 mT/m and 500 T/m/s for a 620 A/1500 V driver. The gradient coil yielded substantially reduced echo spacing, and minimum repetition time and echo time. In high b = 10,000 s/mm2 diffusion, echo time (TE) < 50 ms was achieved (>50% reduction compared with whole-body gradients). The gradient coil passed the American College of Radiology tests for gradient linearity and distortion, and met acoustic requirements for nonsignificant risk operation. CONCLUSIONS: Ultra-high gradient coil performance was achieved for head imaging without substantial increases in gradient driver power in a whole-body 3.0T magnet after removing the standard gradient coil. As such, any clinical whole-body 3.0T MR system could be upgraded with 3-4× improvement in gradient performance for brain imaging.


Assuntos
Encéfalo , Imageamento por Ressonância Magnética , Acústica , Encéfalo/diagnóstico por imagem , Desenho de Equipamento , Cabeça/diagnóstico por imagem , Humanos , Campos Magnéticos
15.
Mil Med ; 183(suppl_1): 73-77, 2018 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-29635555

RESUMO

Objectives: This work describes customized, task-specific simulation models derived from 3D printing in clinical settings and medical professional training programs. Methods: Simulation models/task trainers have an array of purposes and desired achievements for the trainee, defining that these are the first step in the production process. After this purpose is defined, computer-aided design and 3D printing (additive manufacturing) are used to create a customized anatomical model. Simulation models then undergo initial in-house testing by medical specialists followed by a larger scale beta testing. Feedback is acquired, via surveys, to validate effectiveness and to guide or determine if any future modifications and/or improvements are necessary. Results: Numerous custom simulation models have been successfully completed with resulting task trainers designed for procedures, including removal of ocular foreign bodies, ultrasound-guided joint injections, nerve block injections, and various suturing and reconstruction procedures. These task trainers have been frequently utilized in the delivery of simulation-based training with increasing demand. Conclusions: 3D printing has been integral to the production of limited-quantity, low-cost simulation models across a variety of medical specialties. In general, production cost is a small fraction of a commercial, generic simulation model, if available. These simulation and training models are customized to the educational need and serve an integral role in the education of our military health professionals.


Assuntos
Educação Médica/métodos , Corpos Estranhos/cirurgia , Treinamento por Simulação/métodos , Competência Clínica/normas , Educação Médica/economia , Olho/anatomia & histologia , Corpos Estranhos/diagnóstico , Humanos , Modelos Educacionais , Impressão Tridimensional/economia , Treinamento por Simulação/economia
16.
Prim Care ; 45(1): 155-168, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29406941

RESUMO

Cardiovascular imaging with calcium scoring computed tomography (CT), coronary CT angiography (CCTA), and cardiac MRI (CMR) have advanced rapidly over recent years. These imaging modalities have increased in availability, accessibility, and clinical practicality due to technological advances allowing for significant radiation dose reduction for high-quality CCTA and for rapid and reliable imaging techniques in CMR. Hardware and software developments are continually increasing efficiency and accuracy of postprocessing. In the context of these rapidly developing imaging modalities, it is critical for ordering physicians and providers to be aware of the fundamentals of each modality, imaging challenges and appropriate use criteria.


Assuntos
Coração/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Teste de Esforço , Humanos , Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X , Calcificação Vascular/diagnóstico por imagem
17.
J Am Coll Radiol ; 14(5S): S166-S176, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28473073

RESUMO

The incidence of congenital heart disease (CHD) has been increasing in the adult patient population in part as a result of better patient survival. Patients with more severe CHD are living longer. Nearly all adults with known CHD require periodic imaging as a means of monitoring their disease process. Furthermore, adult patients with suspected CHD require imaging as a means of definitive diagnosis. As a result, it is important for both the referring clinician and the imager to be aware of the most appropriate imaging modality needed to obtain the data most needed to direct the next steps in patient care. Imaging procedures for the diagnosis of known or suspected CHD in the adult include chest radiography, fluoroscopy, echocardiography, nuclear scintigraphy, cardiac-gated CT, MRI, and cardiac catheterization/angiography. The physician trying to diagnose these often complex conditions needs complete and reliable information that includes details about intracardiac and vascular anatomy, hemodynamics, and function. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision include an extensive analysis of current medical literature from peer-reviewed journals and the application of well-established methodologies (RAND/UCLA Appropriateness Method and Grading of Recommendations Assessment, Development, and Evaluation or GRADE) to rate the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where evidence is lacking or equivocal, expert opinion may supplement the available evidence to recommend imaging or treatment.


Assuntos
Cardiopatias/congênito , Cardiopatias/diagnóstico por imagem , Adulto , Diagnóstico por Imagem/métodos , Humanos , Radiologia , Sociedades Médicas , Sobrevivência , Estados Unidos
18.
J Am Coll Radiol ; 14(5S): S71-S80, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28473096

RESUMO

In patients with chronic chest pain in the setting of high probability of coronary artery disease (CAD), imaging has major and diverse roles. First, imaging is valuable in determining and documenting the presence, extent, and severity of myocardial ischemia, hibernation, scarring, and/or the presence, site, and severity of obstructive coronary lesions. Second, imaging findings are important in determining the course of management of patients with suspected chronic myocardial ischemia and better defining those patients best suited for medical therapy, angioplasty/stenting, or surgery. Third, imaging is also necessary to determine the long-term prognosis and likely benefit from various therapeutic options by evaluating ventricular function, diastolic relaxation, and end-systolic volume. Imaging studies are also required to demonstrate other abnormalities, such as congenital/acquired coronary anomalies and severe left ventricular hypertrophy, that can produce angina in the absence of symptomatic coronary obstructive disease due to atherosclerosis. Clinical risk assessment is necessary to determine the pretest probability of CAD. Multiple methods are available to categorize patients as low, medium, or high risk for developing CAD. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision include an extensive analysis of current medical literature from peer reviewed journals and the application of well-established methodologies (RAND/UCLA Appropriateness Method and Grading of Recommendations Assessment, Development, and Evaluation or GRADE) to rate the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where evidence is lacking or equivocal, expert opinion may supplement the available evidence to recommend imaging or treatment.


Assuntos
Dor no Peito/diagnóstico por imagem , Dor Crônica/diagnóstico por imagem , Doença da Artéria Coronariana/diagnóstico por imagem , Dor no Peito/etiologia , Dor Crônica/etiologia , Doença da Artéria Coronariana/complicações , Diagnóstico por Imagem/métodos , Humanos , Probabilidade , Radiologia , Medição de Risco , Sociedades Médicas , Estados Unidos
19.
3D Print Med ; 3(1): 8, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29782612

RESUMO

BACKGROUND: The prosthetic devices the military uses to restore function and mobility to our wounded warriors are highly advanced, and in many instances not publically available. There is considerable research aimed at this population of young patients who are extremely active and desire to take part in numerous complex activities. While prosthetists design and manufacture numerous devices with standard materials and limb assemblies, patients often require individualized prosthetic design and/or modifications to enable them to participate fully in complex activities. METHODS: Prosthetists and engineers perform research and implement digitally designs in collaboration to generate equipment for their patient's rehabilitation needs. 3D printing allows for these devices to be manufactured from an array of materials ranging from plastic to titanium alloy. Many designs require form fitting to a prosthetic socket or a complex surface geometry. Specialty items can be scanned using computed tomography and digitally reconstructed to produce a virtual 3D model the engineer can use to design the necessary features of the desired prosthetic, device, or attachment. Completed devices are tested for fit and function. RESULTS: Numerous custom prostheses and attachments have been successfully translated from the research domain to clinical reality, in particular, those that feature the use of computed tomography (CT) reconstructions. The purpose of this project is to describe the research pathways to implementation for the following clinical designs: sets of bilateral hockey skates; custom weightlifting prosthetic hands; and a wine glass holder. CONCLUSION: This article will demonstrate how to incorporate CT imaging and 3D printing in the design and manufacturing process of custom attachments and assistive technology devices. Even though some of these prosthesis attachments may be relatively simple in design to an engineer, they have an enormous impact on the lives of our wounded warriors.

20.
J Am Coll Radiol ; 12(12 Pt A): 1266-71, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26653833

RESUMO

Primary imaging options in patients at low risk for coronary artery disease (CAD) who present with undifferentiated chest pain and without signs of ischemia are functional testing with exercise or pharmacologic stress-based electrocardiography, echocardiography, or myocardial perfusion imaging to exclude myocardial ischemia after rule-out of myocardial infarction and early cardiac CT because of its high negative predictive value to exclude CAD. Although possible, is not conclusive whether triple-rule-out CT (CAD, pulmonary embolism, and aortic dissection) might improve the efficiency of patient management. More advanced noninvasive tests such as cardiac MRI and invasive imaging with transesophageal echocardiography or coronary angiography are rarely indicated. With increased likelihood of noncardiac causes, a number of diagnostic tests, among them ultrasound of the abdomen, MR angiography of the aorta with or without contrast, x-ray rib views, x-ray barium swallow, and upper gastrointestinal series, can also be appropriate. The ACR Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed every three years by a multidisciplinary expert panel. The guideline development and review include an extensive analysis of current medical literature from peer-reviewed journals and the application of a well-established consensus methodology (modified Delphi) to rate the appropriateness of imaging and treatment procedures by the panel. In those instances in which evidence is lacking or not definitive, expert opinion may be used to recommend imaging or treatment. This recommendation is based on excellent evidence, including several randomized comparative effectiveness trials and blinded observational cohort studies.


Assuntos
Dor no Peito/diagnóstico , Doença da Artéria Coronariana/diagnóstico , Diagnóstico por Imagem/métodos , Guias de Prática Clínica como Assunto , Doença Aguda , Estudos de Coortes , Angiografia Coronária/métodos , Diagnóstico Diferencial , Ecocardiografia/métodos , Ecocardiografia Transesofagiana/métodos , Medicina Baseada em Evidências , Feminino , Humanos , Angiografia por Ressonância Magnética/métodos , Masculino , Estudos Observacionais como Assunto , Radiografia Torácica/métodos , Ensaios Clínicos Controlados Aleatórios como Assunto , Sensibilidade e Especificidade , Sociedades Médicas/normas , Tomografia Computadorizada por Raios X/métodos , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...