Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
J Am Soc Echocardiogr ; 24(7): 720-8, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21439782

RESUMO

OBJECTIVE: The study objective was to evaluate whether a novel global position system (GPS)-like position-sensing technology will enable accurate co-registration of images between imaging modalities. Co-registration of images obtained by different imaging modalities will allow for comparison and fusion between imaging modalities, and therefore has significant clinical and research implications. We compared ultrasound (US) and magnetic resonance imaging (MRI) scans of carotid endarterectomy (CEA) specimens using a novel position-sensing technology that uses an electromagnetic (EM) transmitter and sensors mounted on a US transducer. We then evaluated in vivo US-US and US-MRI co-registration. METHODS: Thirteen CEA specimens underwent 3.0 Tesla MRI, after which images were uploaded to a LOGIQ E9 3D (GE Healthcare, Wauwatosa, WI) US system and registered by identifying two to three common points. A similar method was used to evaluate US-MRI co-registration in patients with carotid atherosclerosis. For carotid intima-media thickness (C-IMT) measurements, 10 volunteers underwent bilateral carotid US scans co-registered to three-dimensional US maps created on the initial visit, with a repeat scan 2 days later. RESULTS: For the CEA specimens, there was a mean of 20 (standard error [SE] 2.0) frames per MRI slice. The mean frame difference, over 33 registration markers, between MRI and US scans for readers 1 and 2 was -2.82 ± 19.32 and 2.09 ± 14.68 (mean ± 95% CI) frames, respectively. The US-MRI intraclass correlation coefficients (ICCs) for the first and second readers were 0.995 and 0.997, respectively. For patients with carotid atherosclerosis, the mean US frames per MRI slice (9 [SE 2.3]) was within range of that observed with CEA specimens. Inter-visit, intra-reader, and inter-reader reproducibility of C-IMT measurements were consistently high (side-averaged ICC >0.9). CONCLUSION: Accurate co-registration between US and other modalities is feasible with a GPS-like technology, which has significant clinical and research applicability.


Assuntos
Doenças das Artérias Carótidas/diagnóstico por imagem , Espessura Intima-Media Carotídea , Imagens de Fantasmas , Placa Aterosclerótica/diagnóstico por imagem , Ultrassonografia Doppler/métodos , Doenças das Artérias Carótidas/patologia , Humanos , Imageamento por Ressonância Magnética/métodos , Placa Aterosclerótica/patologia , Reprodutibilidade dos Testes
2.
J Vasc Surg ; 43(2): 259-64; discussion 264, 2006 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-16476596

RESUMO

INTRODUCTION: Currently, postoperative endoleak surveillance after endovascular aortic aneurysm repair (EVAR) is primarily done by computed tomography (CT). The purpose of this study was to determine the efficacy of contrast-enhanced ultrasonography scans to detect endoleaks by using a novel infusion method and compare these findings with those of CT angiography (CTA). METHODS: Twenty male patients (mean age, 70.4 years) underwent surveillance utilizing both CTA and contrast-enhanced color Duplex imaging. One 3-mL vial of Optison (Perfluten Protein A microspheres for injection) and 57 mL normal saline, for a total of 60 mL, were administered to each patient as a continuous infusion at 4 mL/min via a peripheral vein. Each study was optimized with harmonic imaging, and a reduced mechanical index of 0.4 to 0.5, compression of 1 to 3, and a focal zone below the aorta to minimize microsphere rupture. One minute was allowed from the time of infusion to the appearance of contrast in the endograft. Flow was evaluated within the lumen of the graft and its components, as was the presence or absence of endoleaks. Findings were compared with standard color-flow Duplex imaging and CT utilizing CTA reconstruction protocols. RESULTS: All patients evaluated had modular endografts implanted for elective aneurysm repair. Contrast-enhanced duplex scans identified nine endoleaks: one type I and eight type II. No additional endoleaks were seen on CTA. However, CTA failed to recognize three type II endoleaks seen by contrast-enhanced ultrasound. The continuous infusion method allowed for longer and more detailed imaging. An average of 46.8 mL of the contrast infusion solution was used per patient. CONCLUSIONS: Contrast enhanced Duplex ultrasonography accurately demonstrates endoleaks after EVAR and may be considered as a primary surveillance modality. Continuous infusion permits longer imaging time.


Assuntos
Albuminas/administração & dosagem , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Implante de Prótese Vascular/instrumentação , Meios de Contraste/administração & dosagem , Fluorocarbonos/administração & dosagem , Fluxometria por Laser-Doppler/métodos , Falha de Prótese , Tomografia Computadorizada por Raios X , Ultrassonografia Doppler em Cores , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/fisiopatologia , Aneurisma da Aorta Abdominal/cirurgia , Aortografia/métodos , Velocidade do Fluxo Sanguíneo , Humanos , Infusões Intravenosas , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...