Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 64
Filtrar
1.
PLoS One ; 12(6): e0179024, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28640847

RESUMO

OBJECTIVE: To investigate the effect of a heart rate (HR) lowering agent (Ivabradine) on features of atherosclerotic plaque vulnerability with magnetic resonance imaging (MRI), ultrasound imaging, and histology. APPROACH AND RESULTS: Atherosclerosis was induced in the abdominal aorta of 19 rabbits. Nine rabbits were treated with Ivabradine (17 mg/kg/day) during the entire study period. At week 14, imaging was performed. Plaque size was quantified on contrast-enhanced T1-weighted MR images. Microvascular flow, density, and permeability was studied with dynamic contrast-enhanced MRI. Plaque biomechanics was studied by measuring the aortic distension with ultrasound. After, animals were sacrificed and histology was performed. HR was reduced by 16% (p = 0.026) in Ivabradine-treated animals. No differences in absolute and relative vessel wall beat-to-beat distension were found, but due to the reduction in HR, the frequency of the biomechanical load on the plaque was reduced. Plaque size (MR and histology) was similar between groups. Although microvessel density (histology) was similar between groups, AUC and Ktrans, indicative for plaque microvasculature flow, density, and permeability, were decreased by 24% (p = 0.029) and 32% (p = 0.037), respectively. Macrophage content (relative RAM11 positive area) was reduced by 44% (p<0.001) on histology in Ivabradine-treated animals. CONCLUSIONS: HR lowering treatment with Ivabradine in an atherosclerotic rabbit model is associated with a reduction in vulnerable plaque features. The current study suggests that HR reduction may be beneficial for inducing or maintaining a more stable plaque phenotype.


Assuntos
Frequência Cardíaca/efeitos dos fármacos , Placa Aterosclerótica/diagnóstico por imagem , Placa Aterosclerótica/fisiopatologia , Animais , Benzazepinas/farmacologia , Benzazepinas/uso terapêutico , Fenômenos Biomecânicos/efeitos dos fármacos , Pressão Sanguínea/efeitos dos fármacos , Ivabradina , Macrófagos/efeitos dos fármacos , Macrófagos/metabolismo , Masculino , Microvasos/efeitos dos fármacos , Microvasos/metabolismo , Necrose/induzido quimicamente , Neovascularização Patológica/complicações , Placa Aterosclerótica/tratamento farmacológico , Placa Aterosclerótica/patologia , Coelhos
2.
Ultraschall Med ; 38(5): 523-529, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27486794

RESUMO

Purpose Inhomogeneity of arterial wall thickness may be indicative of distal plaques. This study investigates the intra-subject association between relative spatial intima-media thickness (IMT) inhomogeneity of the common carotid artery (CCA) and the degree of stenosis of plaques in the internal carotid artery (ICA). Materials and Methods We included 240 patients with a recent ischemic stroke or transient ischemic attack and mild-to-moderate stenosis in the ipsilateral ICA. IMT inhomogeneity was extracted from B-mode ultrasound recordings. The degree of ICA stenosis was assessed on CT angiography according to the European Carotid Surgery Trial method. Patients were divided into groups with a low (≤ 2 %) and a high (> 2 %) IMT inhomogeneity scaled with respect to the local end-diastolic diameter. Results 182 patients had suitable CT and ultrasound measurements. Relative CCA-IMT inhomogeneity was similar for the symptomatic and asymptomatic side (difference: 0.02 %, p = 0.85). High relative IMT inhomogeneity was associated with a larger IMT (difference: 235 µm, p < 0.001) and larger degree of ICA stenosis (difference: 5 %, p = 0.023) which remained significant (p = 0.016) after adjustment for common risk factors. Conclusion Regardless of common risk factors, high relative CCA-IMT inhomogeneity is associated with a greater degree of ICA stenosis and is therefore indicative of atherosclerotic disease. The predictive value of CCA-IMT inhomogeneity for plaque progression and recurrence of cerebrovascular symptoms will be determined in the follow-up phase of PARISK.


Assuntos
Artéria Carótida Interna , Espessura Intima-Media Carotídea , Estenose das Carótidas , Artéria Carótida Primitiva , Artéria Carótida Interna/diagnóstico por imagem , Estenose das Carótidas/diagnóstico por imagem , Constrição Patológica , Humanos , Fatores de Risco , Túnica Média
3.
Ultrasound Med Biol ; 42(2): 586-95, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26525651

RESUMO

Local arterial stiffness can be assessed with high accuracy and precision by measuring arterial distension on the basis of phase tracking of radiofrequency ultrasound signals acquired at a high frame rate. However, in clinical practice, B-mode ultrasound registrations are made at a low frame rate (20-50 Hz). We compared the accuracy and intra-subject precision of edge tracking and phase tracking distension in symptomatic carotid artery patients. B-mode ultrasound recordings (40 mm, 37 fps) and radiofrequency recordings (31 lines covering 29 mm, 300 fps) were acquired from the left common carotid artery of 30 patients (aged 45-88 y) with recent cerebrovascular events. To extract the distension, semi-automatic echo edge and phase tracking algorithms were applied to B-mode and radiofrequency recordings, respectively. Both methods exhibited a similar intra-subject precision for distension (standard deviation = 44 µm and 47 µm, p = 0.66) and mean distension (difference: -6 ± 69 µm, p = 0.67). Intra-subject distension inhomogeneity tends to be larger for edge tracking (difference: 15 ± 35 µm, p = 0.04). Standard B-mode scanners are suitable for measuring local artery characteristics in symptomatic carotid artery patients with good precision and accuracy.


Assuntos
Artérias Carótidas/diagnóstico por imagem , Artérias Carótidas/fisiopatologia , Doenças das Artérias Carótidas/diagnóstico por imagem , Doenças das Artérias Carótidas/fisiopatologia , Interpretação de Imagem Assistida por Computador/métodos , Rigidez Vascular , Idoso , Algoritmos , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ultrassonografia
4.
Thromb Haemost ; 113(5): 1135-44, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25694037

RESUMO

Observational data suggest a link between menaquinone (MK, vitamin K2) intake and cardiovascular (CV) health. However, MK intervention trials with vascular endpoints are lacking. We investigated long-term effects of MK-7 (180 µg MenaQ7/day) supplementation on arterial stiffness in a double-blind, placebo-controlled trial. Healthy postmenopausal women (n=244) received either placebo (n=124) or MK-7 (n=120) for three years. Indices of local carotid stiffness (intima-media thickness IMT, Diameter end-diastole and Distension) were measured by echotracking. Regional aortic stiffness (carotid-femoral and carotid-radial Pulse Wave Velocity, cfPWV and crPWV, respectively) was measured using mechanotransducers. Circulating desphospho-uncarboxylated matrix Gla-protein (dp-ucMGP) as well as acute phase markers Interleukin-6 (IL-6), high-sensitive C-reactive protein (hsCRP), tumour necrosis factor-α (TNF-α) and markers for endothelial dysfunction Vascular Cell Adhesion Molecule (VCAM), E-selectin, and Advanced Glycation Endproducts (AGEs) were measured. At baseline dp-ucMGP was associated with IMT, Diameter, cfPWV and with the mean z-scores of acute phase markers (APMscore) and of markers for endothelial dysfunction (EDFscore). After three year MK-7 supplementation cfPWV and the Stiffness Index ßsignificantly decreased in the total group, whereas distension, compliance, distensibility, Young's Modulus, and the local carotid PWV (cPWV) improved in women having a baseline Stiffness Index ß above the median of 10.8. MK-7 decreased dp-ucMGP by 50 % compared to placebo, but did not influence the markers for acute phase and endothelial dysfunction. In conclusion, long-term use of MK-7 supplements improves arterial stiffness in healthy postmenopausal women, especially in women having a high arterial stiffness.


Assuntos
Hemostáticos/uso terapêutico , Rigidez Vascular/efeitos dos fármacos , Vitamina K 2/análogos & derivados , Idoso , Proteína C-Reativa/metabolismo , Artérias Carótidas/patologia , Espessura Intima-Media Carotídea , Suplementos Nutricionais , Método Duplo-Cego , Selectina E/sangue , Feminino , Artéria Femoral/patologia , Produtos Finais de Glicação Avançada/sangue , Voluntários Saudáveis , Humanos , Interleucina-6/sangue , Pessoa de Meia-Idade , Pós-Menopausa , Análise de Onda de Pulso , Fator de Necrose Tumoral alfa/sangue , Molécula 1 de Adesão de Célula Vascular/sangue , Vitamina K 2/uso terapêutico
5.
PLoS One ; 10(2): e0115977, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25693114

RESUMO

Flow-mediated dilation is aimed at normalization of local wall shear stress under varying blood flow conditions. Blood flow velocity and vessel diameter are continuous and opposing influences that modulate wall shear stress. We derived an index FMDv to quantify wall shear stress normalization performance by flow-mediated dilation in the brachial artery. In 22 fasting presumed healthy men, we first assessed intra- and inter-session reproducibilities of two indices pFMDv and mFMDv, which consider the relative peak and relative mean hyperemic change in flow velocity, respectively. Second, utilizing oral glucose loading, we evaluated the tracking performance of both FMDv indices, in comparison with existing indices [i.e., the relative peak diameter increase (%FMD), the peak to baseline diameter ratio (Dpeak/Dbase), and the relative peak diameter increase normalized to the full area under the curve of blood flow velocity with hyperemia (FMD/shearAUC) or with area integrated to peak hyperemia (FMD/shearAUC_peak)]. Inter-session and intra-session reproducibilities for pFMDv, mFMDv and %FMD were comparable (intra-class correlation coefficients within 0.521-0.677 range). Both pFMDv and mFMDv showed more clearly a reduction after glucose loading (reduction of ~45%, p≤0.001) than the other indices (% given are relative reductions): %FMD (~11%, p≥0.074); Dpeak/Dbase (~11%, p≥0.074); FMD/shearAUC_peak (~20%, p≥0.016) and FMD/shearAUC (~38%, p≤0.038). Further analysis indicated that wall shear stress normalization under normal (fasting) conditions is already far from ideal (FMDv << 1), which (therefore) does not materially change with glucose loading. Our approach might be useful in intervention studies to detect intrinsic changes in shear stress normalization performance in conduit arteries.


Assuntos
Circulação Sanguínea/fisiologia , Artéria Braquial/fisiologia , Estresse Mecânico , Vasodilatação , Adolescente , Adulto , Velocidade do Fluxo Sanguíneo , Glicemia/metabolismo , Jejum , Teste de Tolerância a Glucose , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
6.
Cardiovasc Ultrasound ; 13: 1, 2015 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-25567641

RESUMO

BACKGROUND: Macrophages may concentrate ultrasound contrast agents and exhibit selective adhesion to activated endothelium. The present study investigates in mice the potential of perfluorohexane (PFH) loaded macrophages to act as ultrasound contrast agent with high reflectivity and specifically targeted at (atherosclerotic) vascular lesions. METHODS: Lung passage was evaluated with a mouse echo scanner after injection, at a slow pace or as a bolus, of varying doses of PFH-loaded and unloaded bone marrow macrophages (BMM) into the jugular vein. The interaction of PFH-loaded and unloaded BMM with TNF-α stimulated carotid artery endothelium after tail vein injection was assessed by means of intravital microscopy. RESULTS: High doses of jugular vein injected PFH-loaded BMM were visible with ultrasound in the pulmonary artery and detectable in the carotid artery. At intravital microscopy, tail vein injected BMM exhibited rolling and adhesion behavior at the TNF-α stimulated carotid endothelium, similar to that of native blood leukocytes. Rolling behavior was not different between PFH-loaded and unloaded BMM (p = 0.38). CONCLUSION: In vivo, perfluorohexane loaded macrophages pass the pulmonary circulation and appear on the arterial side. Moreover, they roll and adhere selectively to activated endothelium under physiological flow conditions. These findings indicate that perfluorohexane loaded BMM could be used to study processes in vivo where endothelial activation plays a role, such as atherosclerosis.


Assuntos
Endotélio Vascular/diagnóstico por imagem , Fluorocarbonos/administração & dosagem , Leucócitos/fisiologia , Macrófagos/fisiologia , Artéria Pulmonar/diagnóstico por imagem , Animais , Adesão Celular/fisiologia , Comunicação Celular/fisiologia , Meios de Contraste , Portadores de Fármacos , Feminino , Injeções Intravenosas , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Ultrassonografia
7.
J Hypertens ; 32(8): 1606-12; discussion 1612, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24886821

RESUMO

OBJECTIVE: We studied whether arterial stiffness measured as aortic pulse wave velocity (aPWV) and carotid distensibility was associated with different subtypes of hypertension in a large population of untreated middle-aged and elderly men and women. METHODS: The study was conducted within the framework of the population-based Rotterdam Study. We included 4088 individuals with information on aPWV, with 3554 individuals with carotid distensibility measurements without use of antihypertensive medication. Isolated systolic hypertension (ISH) was defined as SBP at least 140 mmHg and DBP less than 90 mmHg. Combined systolic and diastolic hypertension (Sys/Dia hypertension) was defined as SBP at least 140 mmHg and DBP at least 90 mmHg. Analysis of covariance was used to compare means of arterial stiffness for the different subtypes of hypertension. Multinomial logistic regression analysis was performed to investigate the association of arterial stiffness and the subtypes of hypertension in models adjusted for age, sex, mean arterial pressure, heart rate and cardiovascular risk factors. RESULTS: The mean age of the individuals was 68 years: 45.3% were men, 1597 individuals had ISH and 441 individuals had Sys/Dia hypertension. aPWV was higher (13.2 vs. 12.9 m/s; P = 0.008) in individuals with ISH compared to those with Sys/Dia hypertension. Multivariate odds ratios and corresponding 95% confidence interval of aPWV for ISH were 1.53 (1.38-1.71) and 1.28 (1.09-1.53) for Sys/Dia hypertension. Corresponding odds ratios associated with carotid distensibility were 0.84 (0.75-0.94) and 0.66 (0.54-0.81), respectively. Age significantly modified the association of aPWV with subtypes of hypertension (P < 0.001). CONCLUSION: In a large untreated population, we found significant associations of both aPWV and carotid distensibility with ISH and Sys/Dia hypertension. individuals with ISH had higher values of aortic stiffness when compared to individuals with Sys/Dia hypertension, a difference that was most pronounced at older age. The results suggest that aortic stiffness contributes to ISH in older individuals without treatment for hypertension.


Assuntos
Hipertensão/fisiopatologia , Rigidez Vascular , Idoso , Artérias Carótidas/fisiopatologia , Diástole/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise de Onda de Pulso , Sístole/fisiologia
8.
Am J Physiol Heart Circ Physiol ; 305(12): H1790-7, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24124184

RESUMO

Recently, the ventilatory variation in pre-ejection period (ΔPEP) was found to be useful in the prediction of fluid-responsiveness of patients in shock. In the present study we investigated the behavior of the ventilation-induced variations in the systolic timing intervals in response to a graded hemorrhage protocol. The timing intervals studied included the ventilatory variation in ventricular electromechanical delay (ΔEMD), isovolumic contraction period (determined from the arterial pressure waveform, ΔAIC), pulse travel time (ΔPTT), and ΔPEP. ΔAIC and ΔPEP were evaluated in the aorta and carotid artery (annotated by subscripts Ao and CA) and were compared with the responses of pulse pressure variation (ΔPPAo) and stroke volume variation (ΔSV). The graded hemorrhage protocol, followed by resuscitation using norepinephrine and autologous blood transfusion, was performed in eight anesthetized Yorkshire X Landrace swine. ΔAICAo, ΔAICCA, ΔPEPAo, ΔPEPCA, ΔPPAo, ΔPPCA, and ΔSV showed significant increases during the graded hemorrhage and significant decreases during the subsequent resuscitation. ΔAICAo, ΔAICCA, ΔPEPAo, and ΔPEPCA all correlated well with ΔPPAo and ΔSV (all r ≥ 0.8, all P < 0.001). ΔEMD and ΔPTT did not significantly change throughout the protocol. In contrast with ΔPEPAo, which was significantly higher than ΔPEPCA (P < 0.01), ΔAICAo was not different from ΔAICCA. In conclusion, ventilation-induced preload variation principally affects the arterially determined isovolumic contraction period (AIC). Moreover, ΔAIC can be determined solely from the arterial pressure waveform, whereas ΔPEP also requires ECG measurement. Importantly, ΔAIC determined from either the carotid or aortic pressure waveform are interchangeable, suggesting that, in contrast with ΔPEP, ΔAIC may be site independent.


Assuntos
Pressão Sanguínea/fisiologia , Frequência Cardíaca/fisiologia , Contração Miocárdica/fisiologia , Choque Hemorrágico/diagnóstico , Volume Sistólico/fisiologia , Animais , Feminino , Ressuscitação , Índice de Gravidade de Doença , Choque Hemorrágico/fisiopatologia , Suínos
10.
Physiol Meas ; 33(4): 557-69, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22415053

RESUMO

Prior to aortic valve opening, aortic pressure is perturbed by ventricular contraction. The onset of this pressure perturbation coincides with the onset of the left ventricular (LV) isovolumic contraction, and hence will be referred to as the start of the arterially detected isovolumic contraction (AIC(start)). In the present study we test the hypothesis that the pressure perturbation indeed has a cardiac origin. In ten Yorkshire-Landrace swine, waveform intensity analysis demonstrated that AIC(start) was followed by a positive intensity wave (0.3 × 10(5) ± 0.3 × 10(5) W (m(2) s(2))(-1)). Timing analysis of LV and aortic pressure waveform showed that AIC(start) was preceded by a LV pressure perturbation (3.8 ± 1.8 ms, p < 0.001). These novel cardiac timing and aortic wave intensity findings reveal the cardiac origin of the pressure perturbation. In 15 Yorkshire-Landrace swine, myocardial motion analysis showed a significantly higher rate of segment shortening during the first part of the LV pressure perturbation. Therefore, both the LV and aortic pressure perturbation are most likely caused by the early phase of myocardial contraction, which also causes mitral valve closure. Consequently, AIC(start) is useful in the determination of the isovolumic contraction period, a well-known marker to quantify cardiac dysfunction.


Assuntos
Aorta/fisiologia , Pressão Sanguínea/fisiologia , Contração Miocárdica/fisiologia , Função Ventricular Esquerda/fisiologia , Análise de Ondaletas , Animais , Velocidade do Fluxo Sanguíneo/fisiologia , Eletrocardiografia , Feminino , Frequência Cardíaca/fisiologia , Humanos , Suínos , Fatores de Tempo
11.
Eur J Prev Cardiol ; 19(4): 698-705, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21697209

RESUMO

AIM: Non-invasive measures of atherosclerosis, such as carotid intima-media thickness (cIMT), may improve global cardiovascular risk prediction. The aim of this study was to determine whether common carotid IMT in addition to traditional risk factors improves risk classification in a general population of older people. METHODS AND RESULTS: A group of 3580 non-diabetic people aged 55-75 years and free of cardiovascular disease at baseline were followed for a median time of 12.2 years. Compared to models based on Framingham risk factors, we studied the ability of common cIMT measurement to better classify people into categories of low (<10%), intermediate (10-20%) and high (>20%) 10-year risk of hard coronary heart disease (CHD) and stroke. In older men, addition of cIMT to Framingham risk factors did not improve prediction of hard CHD or stroke. In older women, addition of cIMT to Framingham risk factors significantly improved risk classification. cIMT improved the C-statistic of the model for hard CHD from 0.711 to 0.719 and for stroke from 0.712 to 0.721, at good calibration. Reclassification was least in the majority of women classified as low risk (4% (n = 76) for hard CHD and 3% (n = 62) for stroke) and most substantial in women at intermediate risk (43% (n = 70) for hard CHD and 28% (n = 76) for stroke). The net reclassification improvement in women was 8.2% (p = 0.03) for hard CHD and 8.0% (p = 0.06) for stroke. CONCLUSION: cIMT had some additional value beyond traditional risk factors in the cardiovascular risk stratification of older women, but not of older men.


Assuntos
Envelhecimento , Doenças das Artérias Carótidas/diagnóstico por imagem , Artéria Carótida Primitiva/diagnóstico por imagem , Espessura Intima-Media Carotídea , Doença das Coronárias/epidemiologia , Acidente Vascular Cerebral/epidemiologia , Fatores Etários , Idoso , Doenças das Artérias Carótidas/epidemiologia , Técnicas de Apoio para a Decisão , Progressão da Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Países Baixos/epidemiologia , Valor Preditivo dos Testes , Prognóstico , Modelos de Riscos Proporcionais , Estudos Prospectivos , Medição de Risco , Fatores de Risco , Fatores Sexuais , Fatores de Tempo
13.
Med Biol Eng Comput ; 49(8): 917-24, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21487819

RESUMO

In earlier work, we suggested that the start of the isovolumic contraction period could be detected in arterial pressure waveforms as the start of a temporary pre-systolic pressure perturbation (AIC(start), start of the Arterially detected Isovolumic Contraction), and proposed the retrograde coronary blood volume flow in combination with a backwards traveling pressure wave as its most likely origin. In this study, we tested this hypothesis by means of a coronary artery occlusion protocol. In six Yorkshire × Landrace swine, we simultaneously occluded the left anterior descending (LAD) and left circumflex (LCx) artery for 5 s followed by a 20-s reperfusion period and repeated this sequence at least two more times. A similar procedure was used to occlude only the right coronary artery (RCA) and finally all three main coronary arteries simultaneously. None of the occlusion protocols caused a decrease in the arterial pressure perturbation in the aorta during occlusion (P > 0.20) nor an increase during reactive hyperemia (P > 0.22), despite a higher deceleration of coronary blood volume flow (P = 0.03) or increased coronary conductance (P = 0.04) during hyperemia. These results show that the pre-systolic aortic pressure perturbation does not originate from the coronary arteries.


Assuntos
Aorta/fisiopatologia , Estenose Coronária/fisiopatologia , Vasos Coronários/fisiopatologia , Contração Miocárdica/fisiologia , Animais , Eletrocardiografia , Feminino , Hemodinâmica/fisiologia , Hiperemia/fisiopatologia , Sus scrofa
15.
Ultrasound Med Biol ; 36(3): 467-79, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20172448

RESUMO

Transcutaneous ultrasound measurements of common carotid artery (CCA) diameter and intima-media thickness (IMT) give insight on arterial dynamics and anatomy, both correlating well with atherosclerosis and risk of cardiovascular disease. We propose a novel automatic algorithm to estimate CCA diameter and IMT in ultrasound (US) images, based on separate analysis of anterior and posterior CCA walls and able to distinguish internal (intima-intima) and external (adventitia-adventitia) diameter. The method combines off-line signal- and image-processing techniques to accommodate echo images acquired at a frame rate of 30 Hz and composed directly from RF data, circumventing digital video-grabbing. Segmentation consists of automatic CCA recognition, followed by adventitial delineation performed with a sustain-attack filter with exponentially decaying reference functions. Intimal delineation is then based on the multiscale anisotropic barycenter (MAB), which is an extension of a known delineation method involving the "first order absolute central moment" of the echo amplitude. An automatic measure of the quality of the US beam incidence for each wall is superimosed on the CCA contour overlays for visual feedback. Validation is carried out on 36 US CCA acquisitions from 12 healthy volunteers, as well as on synthetic US images. Results indicate good accuracy on synthetic US images (within 1.3% for diameter and 3% for IMT). The in vivo intra-recording beat-to-beat variations are on average lower than 50 microm for external diameter and IMT, and lower than 100 microm for internal diameter. A comparison with a commercial device (ART.LAB system) shows that the proposed algorithm performs better in terms of inter-recording precision. The beam incidence control significantly improves the repeatability of IMT estimates, and motivates sonographers actively to maintain a proper scan plane throughout the acquisition to minimize the incidence of confounding factors. The method is clinically viable, providing robust estimates of CCA internal and external diameter and IMT waveforms for both CCA walls, even at a low B-mode update rate of 30 Hz.


Assuntos
Algoritmos , Artérias Carótidas/diagnóstico por imagem , Ultrassonografia/normas , Adolescente , Adulto , Automação , Feminino , Humanos , Masculino , Controle de Qualidade , Padrões de Referência , Software , Adulto Jovem
16.
Hypertension ; 55(1): 124-30, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19933922

RESUMO

Arterial stiffening plays an important role in the development of hypertension and cardiovascular diseases. The intrinsically nonlinear (ie, pressure-dependent) elastic behavior of arteries may have serious consequences for the accuracy and interpretation of arterial stiffness measurements and, ultimately, for individual patient management. We determined aortic pressure and common carotid artery diameter waveforms in 21 patients undergoing cardiac catheterization. The individual pressure-area curves were described using a dual exponential analytic model facilitating noise-free calculation of incremental pulse wave velocity. In addition, compliance coefficients were calculated separately in the diastolic and systolic pressure ranges, only using diastolic, dicrotic notch, and systolic data points, which can be determined noninvasively. Pulse wave velocity at systolic pressure exhibited a much stronger positive correlation with pulse pressure (P<0.001) and age (P=0.012) than pulse wave velocity at diastolic pressure. Patients with an elevated systolic blood pressure (>140 mm Hg) had a 2.5-times lower compliance coefficient in the systolic pressure range than patients with systolic blood pressures <140 mm Hg (P=0.002). Most importantly, some individuals, with comparable age or pulse pressure, had similar diastolic but discriminately different systolic pulse wave velocities and compliance coefficients. We conclude that noninvasive assessment of arterial stiffness could and should discriminate between systolic and diastolic pressure ranges to more precisely characterize arterial function in individual patients.


Assuntos
Artérias/patologia , Artérias/fisiopatologia , Pressão Sanguínea/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco , Doenças Cardiovasculares/diagnóstico , Doenças Cardiovasculares/fisiopatologia , Artérias Carótidas/patologia , Artérias Carótidas/fisiopatologia , Elasticidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fluxo Pulsátil , Pulso Arterial , Sístole
17.
Ultrasound Med Biol ; 36(2): 181-91, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20018434

RESUMO

Molecular imaging may provide new insights into the early detection and development of atherosclerosis before first symptoms occur. One of the techniques in use employs noninvasive ultrasound. In the past decade, experimental and clinical validation studies showed that for the microcirculation targeted ultrasound contrast agents, such as echogenic liposomes, microbubbles and perfluorocarbon emulsions, do improve visualization of specific structures. For large arteries, however, successful application is less obvious. In this review, we will address the challenges for molecular imaging of large arteries. We will discuss the problems encountered in the use of targeted ultrasound contrast agents presently available, mainly based on data obtained in flow chambers and animal studies because clinical studies are lacking. We conclude that molecular imaging of activated endothelium in large- and middle-sized arteries by site-specific accumulation of contrast material is still difficult to achieve due to wall shear stress conditions in these vessels.


Assuntos
Artérias/diagnóstico por imagem , Meios de Contraste/química , Diagnóstico por Imagem , Animais , Diagnóstico por Imagem/métodos , Humanos , Ultrassonografia
18.
Cerebrovasc Dis ; 29(2): 199-205, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20029190

RESUMO

BACKGROUND: Alterations in arterial absolute distension (AD) and relative distension (RD) in the common carotid artery (CCA), as observed by ultrasound, may relate to atherosclerotic processes in a nearby vascular segment. The main objective of the study was to establish to what extent these mechanical vascular alterations relate to carotid bulb stenosis. METHODS: The AD, RD and their interrecording variation (Delta AD and Delta RD), representing the spatial inhomogeneity of AD and RD, were evaluated in 308 CCA and associated with the degree of bulb stenosis. RESULTS: The mechanical CCA parameters were marginally correlated to the degree of ipsilateral (r = -0.14 for AD and r = -0.28 for RD) and contralateral stenosis (r = -0.21 for AD and r = -0.27 for RD). However, Delta AD (r = 0.54; p < 0.001) and Delta RD (r = 0.59; p < 0.001) were significantly correlated to ipsilateral stenosis, independent of age, gender and pulse pressure. CONCLUSIONS: The indices of CCA arterial stiffness are weakly associated with ipsilateral bulb stenosis, but their interrecording variation is a good indicator for atherosclerotic alterations in the carotid bulb. The results indicate that a focal atherosclerotic lesion is associated with modifications in the dynamic characteristics of a nearby vascular segment.


Assuntos
Artéria Carótida Primitiva/diagnóstico por imagem , Estenose das Carótidas/diagnóstico por imagem , Ultrassonografia Doppler Dupla , Idoso , Artéria Carótida Primitiva/fisiopatologia , Estenose das Carótidas/fisiopatologia , Complacência (Medida de Distensibilidade) , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Índice de Gravidade de Doença , Ultrassonografia Doppler em Cores
20.
Clin Exp Hypertens ; 31(5): 389-99, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19811349

RESUMO

We studied the associations of three renin-angiotensin system polymorphisms, angiotensin-converting enzyme (ACE) I/D, angiotensinogen 235 M/T, and angiotensin II receptor type I 573 C/T, with arterial stiffness. The study was embedded in the Rotterdam Study, a population-based study older adults. The association of the polymorphisms with pulse wave velocity, the carotid distensibility, and pulse pressure was investigated in 3706 subjects. We found no association of the ACE I/D polymorphism with pulse wave velocity, but the D-allele was associated with a lower distensibility coefficient (p = 0.05) and higher pulse pressure (p = 0.01). For the angiotensinogen 235 M/T polymorphism, no significant associations with either pulse wave velocity (p = 0.71), the distensibility coefficient (p = 0.16) or pulse pressure (p = 0.34) were found. Also, we found no significant associations of pulse wave velocity (PWV) (p = 0.32), the distensibility coefficient (p = 0.08), and pulse pressure (p = 0.09) with the angiotensin II receptor type 1 573 C/T polymorphism. No epistatic effects were observed between the three renin-angiotensin system (RAS) genes with arterial stiffness. Our findings suggest that genetic variation in the renin-angiotensin system may play a role in determining carotid distensibility and pulse pressure.


Assuntos
Angiotensinogênio/genética , Artérias/fisiopatologia , Elasticidade/fisiologia , Peptidil Dipeptidase A/genética , Polimorfismo Genético/genética , Receptor Tipo 1 de Angiotensina/genética , Sistema Renina-Angiotensina/genética , Idoso , Pressão Sanguínea/genética , Pressão Sanguínea/fisiologia , Estudos de Coortes , Feminino , Humanos , Masculino , Países Baixos , Estudos Prospectivos , Fluxo Pulsátil/genética , Fluxo Pulsátil/fisiologia , Fluxo Sanguíneo Regional/genética , Fluxo Sanguíneo Regional/fisiologia , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...