Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Neth Heart J ; 32(3): 143-145, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38180688
2.
Neth Heart J ; 32(3): 140, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38227098
3.
Artigo em Inglês | MEDLINE | ID: mdl-37897538

RESUMO

BACKGROUND AND AIMS: One third of patients with atrial fibrillation (AF) suffer from high levels of anxiety and depression, which may significantly impair quality of life (QoL). The purpose of this study was to assess whether depressive and anxiety symptoms before ablation affect the QoL in patients with AF one year after cryoballoon ablation (CBA). METHODS: This single-center retrospective study investigated whether the AF patients with a high Hospital Anxiety and Depression Scale (HADS) score (≥ 8) had worse outcomes than patients with a low pre-ablation HADS score (< 8). The primary outcome was the difference in post-ablation QoL, and the secondary outcome included the difference in pre-ablative QoL, QoL improvement, and self-reported AF. RESULTS: Two hundred ninety-five patients were stratified according to their HADS scores (total, depression, and anxiety). Patients with an elevated HADS total, depression, or anxiety score (≥ 8), had a significantly lower QoL before and 12 months after CBA than patients with a HADS score < 8 (p-value < 0.001 for all groups). All groups improved significantly in QoL after CBA ablation and to a similar extent. Sixty-three percent of the patients reported AF symptoms after the procedure, which was comparable between the cohorts of patients. CONCLUSION: Patients with elevated HADS scores reported a lower QoL compared to participants with low HADS scores at baseline and 12 months after CBA. However, both groups improved in QoL after CBA, irrespective of their depressive and anxiety symptoms.

4.
J Cardiovasc Electrophysiol ; 33(5): 885-896, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35257441

RESUMO

INTRODUCTION: Approximately 18% of patients with atrial fibrillation (AF) undergo a repeat ablation within 12 months after their index ablation. Despite the high prevalence, comparative studies on nonpulmonary vein (PV) target strategies in repeat AF ablation are scarce. Here, we describe 12 months efficacy of non-PV and PV target ablations as a repeat ablation strategy. METHODS: A multicentre retrospective, descriptive study was conducted with data of 280 patients who underwent repeat AF ablation. The ablation strategy for repeat ablation was at the operators' discretion. Non-PV target ablation (n = 140) included PV reisolation, posterior wall isolation, mitral line, roofline, and/or complex fractionated atrial electrogram ablation. PV target ablation (n = 140), included reisolation and/or wide atrium circumferential ablation. Patients' demographics and rhythm outcomes during 12 months follow-up were analyzed. RESULTS: At 12 months, more atrial tachyarrhythmias were observed in the non-PV target group (48.6%) compared to the PV target group (29.3%, p = .001). Similarly, a significantly higher AF and atrial tachycardia (AT) recurrence rate was observed after non-PV target ablation compared to PV target ablation (36.4% vs. 22.1% and 22.9% vs. 10.7%). After adjustment, a significantly higher risk of AT recurrence remained in the non-PV target group. Both groups significantly de-escalated antiarrhythmic drug use; de-escalation was more profound after PV target ablation. Patients with isolated PVs during non-PV target ablation had a significantly higher risk for AF recurrence than those with reconnected PVs. CONCLUSION: Compared to PV target ablation, non-PV target repeat ablation did not improve outcomes after 12 months and was independently associated with an increased risk for AT recurrences.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/etiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Humanos , Veias Pulmonares/cirurgia , Recidiva , Estudos Retrospectivos , Resultado do Tratamento
5.
J Am Heart Assoc ; 9(10): e015138, 2020 05 18.
Artigo em Inglês | MEDLINE | ID: mdl-32406296

RESUMO

BACKGROUND The correct interpretation of the ECG is pivotal for the accurate diagnosis of many cardiac abnormalities, and conventional computerized interpretation has not been able to reach physician-level accuracy in detecting (acute) cardiac abnormalities. This study aims to develop and validate a deep neural network for comprehensive automated ECG triage in daily practice. METHODS AND RESULTS We developed a 37-layer convolutional residual deep neural network on a data set of free-text physician-annotated 12-lead ECGs. The deep neural network was trained on a data set with 336.835 recordings from 142.040 patients and validated on an independent validation data set (n=984), annotated by a panel of 5 cardiologists electrophysiologists. The 12-lead ECGs were acquired in all noncardiology departments of the University Medical Center Utrecht. The algorithm learned to classify these ECGs into the following 4 triage categories: normal, abnormal not acute, subacute, and acute. Discriminative performance is presented with overall and category-specific concordance statistics, polytomous discrimination indexes, sensitivities, specificities, and positive and negative predictive values. The patients in the validation data set had a mean age of 60.4 years and 54.3% were men. The deep neural network showed excellent overall discrimination with an overall concordance statistic of 0.93 (95% CI, 0.92-0.95) and a polytomous discriminatory index of 0.83 (95% CI, 0.79-0.87). CONCLUSIONS This study demonstrates that an end-to-end deep neural network can be accurately trained on unstructured free-text physician annotations and used to consistently triage 12-lead ECGs. When further fine-tuned with other clinical outcomes and externally validated in clinical practice, the demonstrated deep learning-based ECG interpretation can potentially improve time to treatment and decrease healthcare burden.


Assuntos
Aprendizado Profundo , Eletrocardiografia , Cardiopatias/diagnóstico , Processamento de Sinais Assistido por Computador , Triagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Automação , Tomada de Decisão Clínica , Feminino , Cardiopatias/fisiopatologia , Cardiopatias/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Adulto Jovem
6.
J Interv Card Electrophysiol ; 39(3): 201-9, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24317918

RESUMO

PURPOSE: The success of PVAI in eliminating AF has been proven; however, its impact on the LA remains uncertain. This study aimed to determine the impact of pulmonary vein antrum isolation (PVAI) on left atrial (LA) size and function in patients with atrial fibrillation (AF). METHODS: Consecutive patients with AF were included (n = 206). Magnetic resonance imaging (MRI) was performed before and after PVAI in all patients. A subgroup (n = 52) underwent delayed enhancement MRI. Maximal LA volume (LAVmax) and minimal LA volume (LAVmin) were assessed by Simpson's rule. LA function was determined by calculating LA ejection fraction (LA EF). LA fibrosis was manually encircled and summed in the region of interest. RESULTS: Single procedure success rate was 64 %. LAVmax decreased post-ablation in all patients (125.1 to 111.9 ml, p < 0.001). LAVmin only decreased in patients with a successful outcome post-ablation (65.6 to 58.8 ml, p < 0.001). As a result, LA EF only showed a marked reduction in patients with AF recurrences (42.7 % to 37.9 %, p < 0.001). Post-ablation LA fibrosis could be visualized in 77 % of patients who underwent delayed enhancement MRI (mean amount 1.4 cm(3)). LA fibrosis showed no correlation with the decrease in LAVmax or LA EF. CONCLUSIONS: PVAI resulted in a reduction of LAVmax in all patients, indicating an effect of ablation induced fibrosis. LAVmin only decreased in patients with a successful outcome, indicating an effect of reverse atrial remodeling. As a result, LA function post-ablation was preserved in patients with a successful outcome and decreased in patients with AF recurrence.


Assuntos
Fibrilação Atrial/cirurgia , Função do Átrio Esquerdo , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Comorbidade , Meios de Contraste , Feminino , Fibrose/diagnóstico , Fibrose/cirurgia , Humanos , Imagem Cinética por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Compostos Organometálicos , Ondas de Rádio , Resultado do Tratamento
7.
Europace ; 13(3): 371-5, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21186231

RESUMO

AIMS: Pulmonary vein antrum isolation (PVAI) is an effective treatment for atrial fibrillation (AF); however, its impact on left atrial (LA) size is unknown. This study evaluates the impact of PVAI on LA size, and whether LA size differs between patients with a successful outcome and patients with AF recurrences. METHODS AND RESULTS: Seventy-nine patients (76% male, mean age 56 ± 8 years) with symptomatic, drug refractory AF (70% paroxysmal, 30% persistent/permanent) underwent radiofrequency PVAI. Ablation lesions were created encircling right and left pulmonary venous ostia in pairs. The endpoint was complete isolation of all pulmonary veins. Magnetic resonance imaging was performed before and 4 months after PVAI and LA volume was measured by manually tracing the LA area. Clinical follow-up was at 1, 3, 6, 12, and 24 months. Rhythm status was determined by history, electrocardiogram, and 48 h Holter monitoring. After a mean follow-up of 12 ± 5 months, 62 patients (78%) were free of AF (72% without antiarrhythmic drugs). In the total group, LA volume decreased from 104 ± 27 mL to 91 ± 25 mL, P < 0.001. Patients with a successful outcome showed a decrease in LA volume of 103 ± 27 mL to 89 ± 24 mL, P < 0.001. Among patients with AF recurrences, LA volume decreased from 105 ± 29 mL to 95 ± 27 mL, P = 0.012. No significant difference was seen between the change in LA volume in both subgroups, P = 0.27. CONCLUSION: Pulmonary vein antrum isolation in patients with AF resulted in a significant decrease of LA size. There was no relation between the decrease in LA size and the recurrence of AF after PVAI.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Átrios do Coração/patologia , Átrios do Coração/cirurgia , Veias Pulmonares/cirurgia , Feminino , Seguimentos , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Recidiva , Estudos Retrospectivos , Resultado do Tratamento
8.
J Cardiovasc Electrophysiol ; 22(3): 302-9, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20653809

RESUMO

INTRODUCTION: There is an obvious need for a better energy source for pulmonary vein (PV) antrum isolation. OBJECTIVE: We investigated the feasibility and safety of electroporation for the creation of PV ostial lesions. METHODS: After transseptal puncture, a custom 7F decapolar 20 mm circular ablation catheter was placed in the PV ostia of 10 pigs. Ablation was performed with a nonarcing, 200 J application delivered between the catheter and an indifferent patch electrode on the lower back. A single pulse was applied for each catheter position, with a maximum of 4 per ostium. Local PV electrogram amplitude and stimulation threshold were measured at multiple locations in both ostia before and directly after ablation, and after 3 weeks survival, using a regular 4 mm mapping catheter. All PV ostia were sectioned, stained, and histologically investigated. RESULTS: The 3-week survival period was uneventful. PV ostial electrogram amplitude decreased and stimulation threshold increased significantly in most ostia. PV angiograms did not show any stenosis during this short follow-up. Histologically, up to 3.5-mm-deep lesions were found. CONCLUSION: Data suggest that electroporation can safely be used to create lesions in a sensitive environment like PV ostia.


Assuntos
Ablação por Cateter/métodos , Eletroporação , Veias Pulmonares/cirurgia , Análise de Variância , Animais , Ablação por Cateter/efeitos adversos , Ablação por Cateter/instrumentação , Catéteres , Técnicas Eletrofisiológicas Cardíacas , Eletroporação/instrumentação , Desenho de Equipamento , Estudos de Viabilidade , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/patologia , Veias Pulmonares/fisiopatologia , Radiografia , Suínos , Fatores de Tempo
10.
J Cardiovasc Electrophysiol ; 21(11): 1247-50, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20487121

RESUMO

UNLABELLED: Left Atrial Volume and Function Assessment. INTRODUCTION: In patients with atrial fibrillation undergoing catheter ablation, magnetic resonance imaging (MRI) can determine left atrial (LA) volume and function before and after ablation. The most accurate, but time consuming, method to determine LA volume is the multiple slice method (MSM), which involves manual tracing of LA area on each slice. The area length method (ALM) offers a simplified, but unvalidated, alternative for LA volume assessment by MRI. The aim of this study was to compare LA volume and function assessment by ALM with MSM. METHODS AND RESULTS: MRI was performed before and after catheter ablation in 40 patients with atrial fibrillation (30 male, mean age 57 years). All patients had sinus rhythm during imaging. In total, 72 MRI scans were available. LA end-diastolic and end-systolic volumes (EDV, respectively ESV) were measured by both methods. LA function was determined by calculating LA ejection fraction (EF = (EDV-ESV)/EDV). Measured by ALM, mean LA EDV and ESV were significantly lower than using MSM (102 mL and 49 mL vs 111 mL and 65 mL, respectively, P < 0.001) with a larger difference in mean ESV than EDV (16 mL vs 9 mL). This resulted in an overestimation of LA EF by ALM with a mean of 11% (54% by ALM and 42% by MSM, P < 0.001). ALM correlated well with MSM for LA EDV and ESV (r = 0.77, respectively 0.85), and showed no significant difference in intraobserver and interobserver variability. CONCLUSION: ALM significantly underestimates LA volumes and overestimates LA function, but correlates well with the more accurate MSM.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Átrios do Coração/fisiopatologia , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Feminino , Átrios do Coração/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
11.
J Cardiovasc Electrophysiol ; 20(9): 1005-10, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19493152

RESUMO

INTRODUCTION: Preprocedural factors may be helpful in selecting patients with atrial fibrillation (AF) for treatment with catheter ablation and in making an assumption regarding their prognosis. The aims of this study were to investigate whether left atrial (LA) volume and pulmonary venous (PV) anatomy, evaluated by computed tomography (CT) prior to ablation, will predict AF recurrence following catheter ablation. METHODS AND RESULTS: We included 146 patients (mean age 57 +/- 11 years, 83% male) with symptomatic AF (55% paroxysmal, 18% persistent, 27% long-standing persistent). All patients underwent CT scanning prior to catheter ablation to evaluate LA volume and PV anatomy. Circumferential PV isolation was performed guided by Cartomerge electroanatomical mapping. The outcome was defined as complete success, improvement, or failure. After a mean follow-up of 19 +/-7 months, complete success was achieved in 59 patients (40%), and 38 patients (26%) demonstrated improvement. LA volume was found to be an independent predictor of AF recurrence with an adjusted OR of 1.14 for every 10-mL increase in volume (95% CI 1.00-1.29, P = 0.047). PV variations were equally distributed among the different outcomes of the ablation procedure, and therefore univariate analysis did not identify PV anatomy as a predictor of outcome. CONCLUSION: LA volume is an independent predictor of AF recurrence after catheter ablation. Additionally, PV anatomy did not have any effect on the outcome. These findings suggest that an assessment of LA volume may be incorporated into the preprocedural evaluation of patients being considered for AF ablation.


Assuntos
Aortografia/métodos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Flebografia/métodos , Veias Pulmonares/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Feminino , Átrios do Coração , Humanos , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde/métodos , Prognóstico , Reprodutibilidade dos Testes , Medição de Risco/métodos , Fatores de Risco , Sensibilidade e Especificidade , Resultado do Tratamento
12.
J Cardiovasc Electrophysiol ; 20(2): 159-63, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19220573

RESUMO

INTRODUCTION: For patients undergoing catheter ablation of atrial fibrillation (AF), left atrial size is a predictor of recurrence of AF during follow-up. For this reason, major clinical trials have used a left atrial diameter (LAD) of more than 5.0 or 5.5 cm, assessed by echocardiography, as an exclusion criterion for patients deemed candidates for ablation of AF. However, whether LAD accurately reflects true left atrial size has not been systematically investigated. Therefore, the purpose of this study was to test the hypothesis that LAD, measured by echocardiography, accurately correlates to left atrial volume measured by computed tomography (CT). METHODS AND RESULTS: We included 50 patients (mean age 56 +/- 12 years, five female) with symptomatic AF (40% paroxysmal, 60% persistent), referred for catheter ablation. In each patient, transthoracic echocardiography was performed. Additionally, all patients underwent CT using a 64-slice CT scanner. Left atrial volume was calculated by manually tracing left atrial area on each CT cross-sectional image. Patients had a mean LAD measured by echocardiography of 4.5 +/- 0.7 cm, ranging from 2.9 to 5.7 cm. Left atrial volume measured by CT ranged from 67 mL to 270 mL with a mean value of 146 +/- 49 mL. A poor correlation was noted between LAD and left atrial volume, r = 0.49 (P < 0.001). CONCLUSION: LAD measured by echocardiography correlates poorly with left atrial volume measured by CT in patients with AF. As a result, selecting patients with AF for treatment with catheter ablation should not be based on an echocardiographic-derived LAD alone.


Assuntos
Ecocardiografia , Coração/anatomia & histologia , Coração/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Idoso , Feminino , Átrios do Coração/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade
13.
Am J Cardiol ; 102(11): 1567-70, 2008 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-19026316

RESUMO

The success of catheter ablation of atrial fibrillation (AF) is highly dependent on a preprocedural assessment of the size and shape of the left atrium. The most precise method to determine left atrial (LA) volume using computed tomography requires manually tracing the LA area of each cross-sectional image. This is a labor-intensive and time-consuming technique. The purpose of this study was to compare LA volume derived using the "gold-standard" multiple-slice technique with LA volume estimated using 3 orthogonal LA dimensions in patients with AF. The patient population was composed of 100 patients referred for catheter ablation of AF (87 men, mean age 57 +/- 12 years). AF was paroxysmal in 49 patients and persistent in 51. Each patient underwent computed tomography before catheter ablation, and LA volume was measured using the 2 methods. The mean LA volume measured using the multiple-slice technique was 136 +/- 46 ml. According to the simpler estimation approach, the mean LA volume was 112 +/- 41 ml. A close correlation was noted between atrial volumes determined using the 2 methods (r = 0.91, p <0.001). There was a mean underestimation of LA volume by the estimation technique of 17 +/- 13%. In conclusion, the results of this study reveal that LA volume determined using an estimation approach correlates closely with true LA volume as determined using the gold-standard multiple-slice approach. This estimation approach underestimates true LA volume by approximately 20%.


Assuntos
Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/patologia , Função do Átrio Esquerdo , Átrios do Coração/patologia , Tomografia Computadorizada por Raios X , Fibrilação Atrial/fisiopatologia , Ablação por Cateter , Feminino , Átrios do Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Estatística como Assunto , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA