Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Bacteriol ; 198(7): 1149-59, 2016 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-26833409

RESUMO

UNLABELLED: The dimorphic alphaproteobacterium Prosthecomicrobium hirschii has both short-stalked and long-stalked morphotypes. Notably, these morphologies do not arise from transitions in a cell cycle. Instead, the maternal cell morphology is typically reproduced in daughter cells, which results in microcolonies of a single cell type. In this work, we further characterized the short-stalked cells and found that these cells have a Caulobacter-like life cycle in which cell division leads to the generation of two morphologically distinct daughter cells. Using a microfluidic device and total internal reflection fluorescence (TIRF) microscopy, we observed that motile short-stalked cells attach to a surface by means of a polar adhesin. Cells attached at their poles elongate and ultimately release motile daughter cells. Robust biofilm growth occurs in the microfluidic device, enabling the collection of synchronous motile cells and downstream analysis of cell growth and attachment. Analysis of a draft P. hirschii genome sequence indicates the presence of CtrA-dependent cell cycle regulation. This characterization of P. hirschii will enable future studies on the mechanisms underlying complex morphologies and polymorphic cell cycles. IMPORTANCE: Bacterial cell shape plays a critical role in regulating important behaviors, such as attachment to surfaces, motility, predation, and cellular differentiation; however, most studies on these behaviors focus on bacteria with relatively simple morphologies, such as rods and spheres. Notably, complex morphologies abound throughout the bacteria, with striking examples, such as P. hirschii, found within the stalked Alphaproteobacteria. P. hirschii is an outstanding candidate for studies of complex morphology generation and polymorphic cell cycles. Here, the cell cycle and genome of P. hirschii are characterized. This work sets the stage for future studies of the impact of complex cell shapes on bacterial behaviors.


Assuntos
Alphaproteobacteria/citologia , Alphaproteobacteria/fisiologia , Ciclo Celular/fisiologia , Técnicas Bacteriológicas , Biofilmes/crescimento & desenvolvimento
2.
Anal Chem ; 87(24): 12032-9, 2015 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-26496389

RESUMO

In the environment, most bacteria form surface-attached cell communities called biofilms. The attachment of single cells to surfaces involves an initial reversible stage typically mediated by surface structures such as flagella and pili, followed by a permanent adhesion stage usually mediated by polysaccharide adhesives. Here, we determine the absolute and relative timescales and frequencies of reversible and irreversible adhesion of single cells of the bacterium Caulobacter crescentus to a glass surface in a microfluidic device. We used fluorescence microscopy of C. crescentus expressing green fluorescent protein to track the swimming behavior of individual cells prior to adhesion, monitor the cell at the surface, and determine whether the cell reversibly or irreversibly adhered to the surface. A fluorescently labeled lectin that binds specifically to polar polysaccharides, termed holdfast, discriminated irreversible adhesion events from reversible adhesion events where no holdfast formed. In wild-type cells, the holdfast production time for irreversible adhesion events initiated by surface contact (23 s) was 30-times faster than the holdfast production time that occurs through developmental regulation (13 min). Irreversible adhesion events in wild-type cells (3.3 events/min) are 15-times more frequent than in pilus-minus mutant cells (0.2 events/min), indicating the pili are critical structures in the transition from reversible to irreversible surface-stimulated adhesion. In reversible adhesion events, the dwell time of cells at the surface before departing was the same for wild-type cells (12 s) and pilus-minus mutant cells (13 s), suggesting the pili do not play a significant role in reversible adhesion. Moreover, reversible adhesion events in wild-type cells (6.8 events/min) occur twice as frequently as irreversible adhesion events (3.3 events/min), demonstrating that most cells contact the surface multiple times before transitioning from reversible to irreversible adhesion.


Assuntos
Aderência Bacteriana , Caulobacter crescentus/metabolismo , Técnicas Analíticas Microfluídicas , Biofilmes , Caulobacter crescentus/química , Vidro , Proteínas de Fluorescência Verde/metabolismo , Microscopia de Fluorescência
3.
Anal Chem ; 84(20): 8571-8, 2012 Oct 16.
Artigo em Inglês | MEDLINE | ID: mdl-23030473

RESUMO

We report the development of an automated microfluidic "baby machine" to synchronize the bacterium Caulobacter crescentus on-chip and to move the synchronized populations downstream for analysis. The microfluidic device is fabricated from three layers of poly(dimethylsiloxane) and has integrated pumps and valves to control the movement of cells and media. This synchronization method decreases incubation time and media consumption and improves synchrony quality compared to the conventional plate-release technique. Synchronized populations are collected from the device at intervals as short as 10 min and at any time over four days. Flow cytometry and fluorescence cell tracking are used to determine synchrony quality, and cell populations synchronized in minimal growth medium with 0.2% glucose (M2G) and peptone yeast extract (PYE) medium contain >70% and >80% swarmer cells, respectively. Our on-chip method overcomes limitations with conventional physical separation methods that consume large volumes of media, require manual manipulations, have lengthy incubation times, are limited to one collection, and lack precise temporal control of collection times.


Assuntos
Caulobacter crescentus/crescimento & desenvolvimento , Dispositivos Lab-On-A-Chip , Técnicas Analíticas Microfluídicas/instrumentação , Biofilmes/crescimento & desenvolvimento , Caulobacter crescentus/fisiologia , Meios de Cultura/metabolismo , Desenho de Equipamento , Microscopia de Fluorescência
4.
Opt Express ; 16(19): 15206-11, 2008 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-18795059

RESUMO

Using water-assisted femtosecond laser machining, we fabricated electrospray nozzles on glass coverslips and on assembled microfluidic devices. Machining the nozzles after device assembly facilitated alignment of the nozzles over the microchannels. The basic nozzle design is a through-hole in the coverslip to pass liquids and a trough machined around the through-hole to confine the electrospray and prevent liquid from wicking across the glass surface. Electrospray from the nozzles was stable with and without pressure-driven flow applied and was evaluated using mass spectra of the peptide bradykinin.


Assuntos
Análise de Injeção de Fluxo/instrumentação , Vidro/química , Vidro/efeitos da radiação , Lasers , Técnicas Analíticas Microfluídicas/instrumentação , Água , Desenho de Equipamento , Análise de Falha de Equipamento , Eletricidade Estática
5.
Lab Chip ; 8(2): 316-22, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18231672

RESUMO

We report enhanced sample confinement on microfluidic devices using a combination of electrokinetic flow from adjacent control channels and electric field shaping with an array of channels perpendicular to the sample stream. The basic device design consisted of a single first dimension (1D) channel, intersecting an array of 32 or 96 parallel second dimension (2D) channels. To minimize sample dispersion and leakage into the parallel channels as the sample traversed the sample transfer region, control channels were placed to the left and right of the 1D and waste channels. The electrokinetic flow from the control channels confined the sample stream and acted as a buffer between the sample stream and the 2D channels. To further enhance sample confinement, the electric field was shaped parallel to the sample stream by placing the channel array in close proximity to the sample transfer region. Using COMSOL Multiphysics, initial work focused on simulating the electric fields and fluid flows in various device geometries, and the results guided device design. Following the design phase, we fabricated devices with 40, 80, and 120 microm wide control channels and evaluated the sample stream width as a function of the electric field strength ratio in the control and 1D channels (E(C)/E(1D)). For the 32 channel design, the 40 and 80 microm wide control channels produced the most effective sample confinement with stream widths as narrow as 75 microm, and for the 96 channel design, all three control channel widths generated comparable sample stream widths. Comparison of the 32 and 96 channel designs showed sample confinement scaled easily with the length of the sample transfer region.


Assuntos
Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos , Dimetilpolisiloxanos/química , Desenho de Equipamento/instrumentação , Desenho de Equipamento/métodos , Sensibilidade e Especificidade , Eletricidade Estática
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...